Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Com”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

25 records · Page 2

Evidence for CNO processed material in the accretion disk of GP Comae

NIR spectroscopic observations of GP Com are reported. Data obtained using the 2.5-m Isaac Newton Telescope and the 4.2-m William Herschel Telescope at La Palma during April and June 1988 and with the 5-m Hale reflector at Palomar Observatory during January 1983 are presented in tables and sample spectra and discussed in detail. Number ratios H/He less than 0.00001, N/O = about 50, and N/C greater than 100 are calculated under the assumption of a uniform optically thin slab of gas in LTE. From the N overabundance it is inferred that the material observed is being extracted by Roche-lobe overflow from the secondary's H-exhausted core, at a time after most C and O have been converted to N in the CNO cycle.

Marsh, T. R.↗

Evaluation of VIIRS, GOCI, and MODIS Collection 6 AOD Retrievals Against Ground Sunphotometer Observations Over East Asia

Persistent high aerosol loadings together with extremely high population densities have raised serious air quality and public health concerns in many urban centers in East Asia. However, ground-based air quality monitoring is relatively limited in this area. Recently, satellite-retrieved Aerosol Optical Depth (AOD) at high resolution has become a powerful tool to characterize aerosol patterns in space and time. Using ground AOD observations from the Aerosol Robotic Network (AERONET) and the Distributed Regional Aerosol Gridded Observation Networks (DRAGON)-Asia Campaign, as well as from handheld sunphotometers, we evaluated emerging aerosol products from the Visible Infrared Imaging Radiometer Suite (VIIRS) aboard the Suomi National Polar-orbiting Partnership (S-NPP), the Geostationary Ocean Color Imager (GOCI) aboard the Communication, Ocean, and Meteorology Satellite (COMS), and Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) (Collection 6) in East Asia in 2012 and 2013. In the case study in Beijing, when compared with AOD observations from handheld sunphotometers, 51% of VIIRS Environmental Data Record (EDR) AOD, 37% of GOCI AOD, 33% of VIIRS Intermediate Product (IP) AOD, 26% of Terra MODIS C6 3km AOD, and 16% of Aqua MODIS C6 3km AOD fell within the reference expected error (EE) envelope (+/-0.05/+/- 0.15 AOD). Comparing against AERONET AOD over the JapanSouth Korea region, 64% of EDR, 37% of IP, 61% of GOCI, 39% of Terra MODIS, and 56% of Aqua MODIS C6 3km AOD fell within the EE. In general, satellite aerosol products performed better in tracking the day-to-day variability than tracking the spatial variability at high resolutions. The VIIRS EDR and GOCI products provided the most accurate AOD retrievals, while VIIRS IP and MODIS C6 3km products had positive biases.

Xiao, Q.↗

Long-term stability of a Fabry-Perot interferometer used for measurement of stellar Doppler shift

The use of a fiber-optic-link CCD-detector Fabry-Perot interferometer (McMillan et al., 1985, 1986, and 1988) to obtain high-accuracy measurements of stellar Doppler shifts at KPNO is described in detail and illustrated with sample data. Particular attention is given to accuracy requirements and techniques for reducing errors, resolution (orders of 50 mA at wavelength 4300 A are separated by 640 mA), CCD sensitivity, observing and data-processing operations, and the control of environmental conditions. Standard-deviation data and statistics on seven solar-type stars are presented in tables, and the time evolution of the radial velocity of Beta Com is shown in a graph.

Mcmillan, R. S.↗

CHANDRA Detection of the AM CVn Binary ES Cet (KUV 01584-0939)

We report on Chandra ACE observations of the ultracompact AM CVn binary ES Cet. This object has a 10.3 minute binary period and is the most compact of the confirmed AM CVn systems. We have, for the first time, unambiguously detected the X-ray counterpart to ES Cet. In a 20 ksec ACIS-S image a point-like X-ray source is found within 1 sec. of the catalogued optical position. The mean countrate in ACIS-S is 0.013/s, and there is no strong evidence for variability. We folded the X-ray data using the optical ephemeris of Warner & Woudt, but did not detect any significant modulation. If an approx. = 100% modulation similar to those seen in the ultracompact candidates V407 Vu1 and Rx J0806.3+1527 were present then we would have detected it. The upper limit (3(sigma)) to any modulation at the putative orbital period is approx. 40% (rms). We extract the first X-ray spectrum from ES Cet, and find that it is not well described by simple continuum models. We find suggestive evidence for discrete spectral components at approx. 470 and 890 eV, that can be modelled as gaussian emission lines. In comparison with recent X-ray detections of nitrogen and neon in another AM CVn system (GP Com), it appears possible that these features may represent emission lines from these same elements; however, deeper spectroscopy will be required to confirm this. Our best spectral model includes a black body continuum with kT = 0.8 keV along with the gaussian lines. The 0.2 - 5 keV X-ray flux was approx. 7 x 10(exp -14) ergs/sq cm s. The luminosity implied by this flux for any reasonable distance is much smaller than that expected for a mass accretion rate as high as m = 10(exp -8) solar mass/yr, suggesting that the bulk of the accretion luminosity is below 100 eV and not seen with Chandra. We discuss the implications of our results for the nature of ES Cet.

Strohmayer, Tod E.↗

Detection of Nitrogen and Neon in the X-ray Spectrum of GP Com with XMM/Newton

We report on X-ray spectroscopic observations with XMM/Newton of the ultra-compact, double white dwarf binary, GP Com. With the Reflection Grating Spectrometers (RGS) we detect the L(alpha) and L(beta) lines of hydrogen-like nitrogen (N VII) and neon (Ne X), as well as the helium-like triplets (N VI and Ne IX) of these same elements. All the emission lines are unresolved. These are the first detections of X-ray emission lines from a double-degenerate, AM CVn system. We detect the resonance (r) and intercombination (i) lines of the N VI triplet, but not the forbidden (f) line. The implied line ratios for N VI, R = f/i less than 0.3, and G = (f + i ) / r approx. = 1, combined with the strong resonance line are consistent with a dense, collision-dominated plasma. Both the RGS and EPIC/MOS spectra are well fit by emission horn an optically thin thermal plasma with an emission measure (EM) is a member of (kT/6.5 keV)(sup 0.8) (model cevmkl in XSPEC). Helium, nitrogen, oxygen and neon are required to adequately model the spectrum, however, the inclusion of sulphur and iron further improves the fit, suggesting these elements may also be present at low abundance. We confirm in the X-rays the under- abundance of both carbon and oxygen relative to nitrogen, first deduced from optical spectroscopy by Marsh et al. The average X-ray luminosity of approx. = 3 x 10(exp 30) ergs/s implies a mass accretion rate dot-m approx. = 9 x 10(exp -13) solar mass/yr. The implied temperature and density of the emitting plasma, combined with the presence of narrow emission lines and the low dot-m value, are consistent with production of the X-ray emission in an optically thin boundary layer just above the surface of the white dwarf.

Strohmayer, Tod E.↗

Evaluation of the Paratrend Multi-Analyte Sensor for Potential Utilization in Long-Duration Automated Cell Culture Monitoring

BACKGROUND: Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments. While several single-analyte sensors exist to measure culture health, a multi-analyte sensor would simplify the cell culture system. One such multi-analyte sensor, the Paratrend 7 manufactured by Diametrics Medical, consists of three optical fibers for measuring pH, dissolved carbon dioxide (pCO(2)), dissolved oxygen (pO(2)), and a thermocouple to measure temperature. The sensor bundle was designed for intra-vascular measurements in clinical settings, and can be used in bioreactors operated both on the ground and in NASA's Space Shuttle and International Space Station (ISS) experiments. METHODS: A Paratrend 7 sensor was placed at the outlet of a bioreactor inoculated with BHK-21 (baby hamster kidney) cells. The pH, pCO(2), pO(2), and temperature data were transferred continuously to an external computer. Cell culture medium, manually extracted from the bioreactor through a sampling port, was also assayed using a bench top blood gas analyzer (BGA). RESULTS: Two Paratrend 7 sensors were used over a single cell culture experiment (64 days). When compared to the manually obtained BGA samples, the sensor had good agreement for pH, pCO(2), and pO(2) with bias (and precision) 0.005(0.024), 8.0 mmHg (4.4 mmHg), and 11 mmHg (17 mmHg), respectively for the first two sensors. A third Paratrend sensor (operated for 141 days) had similar agreement (0.02+/-0.15 for pH, -4+/-8 mm Hg for pCO(2), and 24+/-18 mmHg for pO(2)). CONCLUSION: The resulting biases and precisions are com- parable to Paratrend sensor clinical results. Although the pO(2) differences may be acceptable for clinically relevant measurement ranges, the O(2) sensor in this bundle may not be reliable enough for the ranges of pO(2) in these cell culture studies without periodic calibration.

Validation Studies↗

High Data Rate Architecture (HiDRA)

One of the greatest challenges in developing new space technology is in navigating the transition from ground based laboratory demonstration at Technology Readiness Level 6 (TRL-6) to conducting a prototype demonstration in space (TRL-7). This challenge is com- pounded by the relatively low availability of new spacecraft missions when compared with aeronautical craft to bridge this gap, leading to the general adoption of a low-risk stance by mission management to accept new, unproven technologies into the system. Also in consideration of risk, the limited selection and availability of proven space-grade components imparts a severe limitation on achieving high performance systems by current terrestrial technology standards. Finally from a space communications point of view the long duration characteristic of most missions imparts a major constraint on the entire space and ground network architecture, since any new technologies introduced into the system would have to be compliant with the duration of the currently deployed operational technologies, and in some cases may be limited by surrounding legacy capabilities. Beyond ensuring that the new technology is verified to function correctly and validated to meet the needs of the end users the formidable challenge then grows to additionally include: carefully timing the maturity path of the new technology to coincide with a feasible and accepting future mission so it flies before its relevancy has passed, utilizing a limited catalog of available components to their maximum potential to create meaningful and unprecedented new capabilities, designing and ensuring interoperability with aging space and ground infrastructures while simultaneously providing a growth path to the future. The International Space Station (ISS) is approaching 20 years of age. To keep the ISS relevant, technology upgrades are continuously taking place. Regarding communications, the state-of-the-art communication system upgrades underway include high-rate laser terminals. These must interface with the existing, aging data infrastructure. The High Data Rate Architecture (HiDRA) project is designed to provide networked store, carry, and forward capability to optimize data flow through both the existing radio frequency (RF) and new laser communications terminal. The networking capability is realized through the Delay Tolerant Networking (DTN) protocol, and is used for scheduling data movement as well as optimizing the performance of existing RF channels. HiDRA is realized as a distributed FPGA memory and interface controller that is itself controlled by a local computer running DTN software. Thus HiDRA is applicable to other arenas seeking to employ next-generation communications technologies, e.g. deep space. In this paper, we describe HiDRA and its far-reaching research implications.

DTN↗