Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Channel simulation for direct-detection optical communication systems

A technique is described for simulating the random modulation imposed by atmospheric scintillation and transmitter pointing jitter on a direct-detection optical communication system. The system is capable of providing signal fading statistics which obey log-normal, beta, Rayleigh, Ricean, or chi-square density functions. Experimental tests of the performance of the channel simulator are presented.

Tycz, M.↗

Receiver processing for direct-detection optical communication systems.

A model that is sufficiently general to describe the predominant statistical characteristics of the output of many real optical detectors is formulated. This model is used to study the optimum receiver processing for direct-detection optical communication systems. In particular, the structures of detectors and estimators for filtered doubly stochastic Poisson processes (DSPP) observed in additive white Gaussian noise are considered. Representations for the posterior statistics of a vector Markov process that modulates the intensity of the DSPP are obtained.

Hoversten, E. V.↗

Enhancing the Optically Detected Magnetic Resonance Signal of Organic Molecular Qubits

In quantum information science and sensing, electron spins are often purified into a specific polarization through an optical-spin interface, a process known as optically detected magnetic resonance (ODMR). Diamond-NV centers and transition metals are both excellent platforms for these so-called color centers, while metal-free molecular analogues are also gaining popularity for their extended polarization lifetimes, milder environmental impacts, and reduced costs. In our earlier attempt at designing such organic high-spin π-diradicals, we proposed to spin-polarize by shelving triplet M S = ±1 populations as singlets. This was recently verified by experiments albeit with low ODMR contrasts of <1% at temperatures above 5 K. In this work, we propose to improve the ODMR signal by moving singlet populations back into the triplet M S = 0 sublevel, designing a true carbon-based molecular analogue to the NV center. Our proposal is based upon transition-orbital and group-theoretical analyses of beyond-nearest-neighbor spin–orbit couplings, which are further confirmed by ab initio calculations of a realistic trityl-based radical dimer. Microkinetic analyses point toward high ODMR contrasts of around 30% under experimentally feasible conditions, a stark improvement from previous works. Finally, in our quest toward ground-state optically addressable molecular spin qubits, we exemplify how our symmetry-based design avoids Zeeman-induced singlet–triplet mixings, setting the scene for realizing electron spin qubit gates.

Group theory↗

Capacity, cutoff rate, and coding for a direct-detection optical channel

It is shown that Pierce's pulse position modulation scheme with 2 to the L pulse positions used on a self-noise-limited direct detection optical communication channel results in a 2 to the L-ary erasure channel that is equivalent to the parallel combination of L completely correlated binary erasure channels. The capacity of the full channel is the sum of the capacities of the component channels, but the cutoff rate of the full channel is shown to be much smaller than the sum of the cutoff rates. An interpretation of the cutoff rate is given that suggests a complexity advantage in coding separately on the component channels. It is shown that if short-constraint-length convolutional codes with Viterbi decoders are used on the component channels, then the performance and complexity compare favorably with the Reed-Solomon coding system proposed by McEliece for the full channel. The reasons for this unexpectedly fine performance by the convolutional code system are explored in detail, as are various facets of the channel structure.

Massey, J. L.↗

Direct detection optical intersatellite link at 220 Mbps using AlGaAs laser diode and silicon APD with 4-ary PPM signaling

A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the insufficient electronic bandwidth of the APD preamplifier and the poor linearity of the preamplifier high frequency response.

Sun, Xiaoli↗

Method of vibration analysis using holographic interferometry and heterodyne optical detection

A method of studying thin plate vibrations with the aid of a laser beam is discussed. Through a suitable combination of time-average holographic interferometry, real-time holographic interferometry, and heterodyne optical detection, it is possible to obtain complete information on the vibration parameters of modes, amplitudes, frequencies, and phases. The method has the advantage of three dimensional global observation, noncontact, and high precision measurements.

Vlad, V. I.↗

Capacity, cutoff rate, and coding for a direct-detection optical channel

It is shown that when Pierce's pulse-position modulation scheme with 2 to the L power positions (where L is some positive integer) is used on a self-noise-limited direct-detection optical communication channel, there results a (2 to the L power)-ary erasure channel that is equivalent to the parallel combination of L completely correlated binary erasure channels. The capacity of the full channel is the sum of the capacities of the component channels, but the cutoff rate of the full channel is shown to be much smaller than the sum of the cutoff rates. An interpretation of the cutoff rate is given that suggests a complexity advantage in coding separately on the component channels. It is shown that if short-constraint length convolutional codes with Viterbi decoders are used on the component channels, then the performance and complexity compare favorably with the Reed-Solomon coding system proposed by McEliece (1979) for the full channel. The reasons for this unexpectedly fine performance by the convolutional code system are explored in detail, as are various facets of the channel structure.

Massey, J. L.↗

Charge state dynamics and optically detected electron spin resonance contrast of shallow nitrogen-vacancy centers in diamond

Nitrogen-vacancy (NV) centers in diamond can be used for nanoscale sensing with atomic resolution and sensitivity; however, it has been observed that their properties degrade as they approach the diamond surface. Here we report that in addition to degraded spin coherence, NV centers within nanometers of the surface can also exhibit decreased fluorescence contrast for optically detected electron spin resonance (OD-ESR). We demonstrate that this decreased OD-ESR contrast arises from charge state dynamics of the NV center, and that it is strongly surface-dependent, indicating that surface engineering will be critical for nanoscale sensing applications based on color centers in diamond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Field Sensing via Optically Detected Magnetic Resonance and Spin Relaxometry Using Nitrogen Vacancies in Nanodiamonds

Quantum sensing is broadly defined as the use of quantum materials, quantum coherence, and/or quantum entanglement to measure physical quantities and/or to enhance the sensitivity of classical analytical measurements. Certain materials exhibit interesting quantum properties that have the potential to be utilized in quantum sensing applications. One such quantum property is electronic spin, which is utilized in this work. Here, we built a custom apparatus capable of conducting both optically detected magnetic resonance (ODMR) and spin relaxometry. The quantum material investigated was an ensemble of nitrogen vacancies (NV) in nanodiamonds. We have characterized the system and measured ODMR spectra for different strengths of the applied DC magnetic field and clearly observed the expected splitting of the resonances due to Zeeman splitting. We also have measured the spin relaxation times for two different powers of the applied AC magnetic field. The lower power dataset exhibited expected exponential temporal dependence of the relaxation of a modified spin state, whereas the higher power dataset exhibited stretched exponential dependence of the evolution of the modified spin state, indicating the presence of high-power phenomena that emerge that retard the relaxation of the spin state.

Lander, Gary↗

Magnetic Field Sensing via Optically Detected Magnetic Resonance and Spin Relaxometry Using Nitrogen Vacancies in Nanodiamonds

Quantum sensing is broadly defined as the use of quantum materials, quantum coherence, and/or quantum entanglement to measure physical quantities and/or to enhance the sensitivity of classical analytical measurements. Certain materials exhibit interesting quantum properties that have the potential to be utilized in quantum sensing applications. One such quantum property is electronic spin, which is utilized in this work. Here, we built a custom apparatus capable of conducting both optically detected magnetic resonance (ODMR) and spin relaxometry. The quantum material investigated was an ensemble of nitrogen vacancies (NV) in nanodiamonds. We have characterized the system and measured ODMR spectra for different strengths of the applied DC magnetic field and clearly observed the expected splitting of the resonances due to Zeeman splitting. We also have measured the spin relaxation times for two different powers of the applied AC magnetic field. The lower power dataset exhibited expected exponential temporal dependence of the relaxation of a modified spin state, whereas the higher power dataset exhibited stretched exponential dependence of the modified spin state, indicating the presence of high-power phenomena that emerge that retard the relaxation of the spin state.

Lander, Gary↗

Optical Detection of Organic Chemical Biosignatures at Hydrothermal Vents

We have developed a non-contact, optical life detection instrument that can detect organic chemical biosignatures in a number of different environments, including dry land, shallow aqueous, deep marine or in ice. Hence, the instrument is appropriate as a biosignature survey tool both for Mars exploration or in situ experiments in an ice-covered ocean such as one might wish to explore on Europa. Here, we report the results we obtained on an expedition aboard the Russian oceanographic vessel Akademik Mstislav Keldysh to hydrothermal vent sites in the Pacific Ocean using our life detection instrument MCDUVE, a multichannel, deep ultraviolet excitation fluorescence detector. MCDUVE detected organic material distribution on rocks near the vent, as well as direct detection of organisms, both microbial and microscopic. We also were able to detect organic material issuing directly from vent chimneys, measure the organic signature of the water column as we ascended, and passively observe the emission of light directly from some vents.

Conrad, P. G.↗

Optical Detection Of Fractures In Ceramic Diaphragms

Simple optical technique enables quick, nondestructive inspection of surfaces of ceramic diaphragms and disks for fractures and discontinuities. Involves reflecting beam of light from laser at glancing angle of about 20 degrees to 25 degrees off surface inspected and examining pattern of reflected light on suitable viewing surface as beam swept across surface. When fracture present, reflection pattern separates into two or more speckled spots. Technique applied in inspection of ceramic diaphragms bearing electronic circuits. Also useful in detection of fatigue cracks on aircraft.

Laue, Eric G.↗

Capacity of a direct detection optical communication channel

The capacity of a free space optical channel using a direct detection receiver is derived under both peak and average signal power constraints and without a signal bandwidth constraint. The addition of instantaneous noiseless feedback from the receiver to the transmitter does not increase the channel capacity. In the absence of received background noise, an optimally coded PPM system is shown to achieve capacity in the limit as signal bandwidth approaches infinity. In the case of large peak to average signal power ratios, an interleaved coding scheme with PPM modulation is shown to have a computational cutoff rate far greater than ordinary coding schemes.

Tan, H. H.↗

Semiconductor Reference Oscillator Development for Coherent Detection Optical Remote Sensing Applications

The NASA Earth Science Enterprise Advanced Technology Initiatives Program is supporting a program for the development of semiconductor laser reference oscillators for application to coherent optical remote sensing from Earth orbit. Local oscillators provide the frequency reference required for active spaceborne optical remote sensing concepts that involve heterodyne (coherent) detection. Two recent examples of such schemes are Doppler wind lidar and tropospheric carbon dioxide measurement by laser absorption spectrometry, both of which are being proposed at a wavelength of 2.05 microns. Frequency-agile local oscillator technology is important to such applications because of the need to compensate for large platform-induced Doppler components that would otherwise interfere with data interpretation. Development of frequency-agile local oscillator approaches has heretofore utilized the same laser material as the transmitter laser (Tm,Ho:YLF in the case of the 2.05-micron wavelength mentioned above). However, a semiconductor laser-based frequency-agile local oscillator offers considerable scope for reduced mechanical complexity and improved frequency agility over equivalent crystal laser devices, while their potentially faster tuning capability suggest the potential for greater scanning versatility. The program we report on here is specifically tasked with the development of prototype novel architecture semiconductor lasers with the power, tunability, and spectral characteristics required for coherent Doppler lidar. The baseline approach for this work is the distributed feedback (DFB) laser, in which gratings are etched into the semiconductor waveguide structures along the entire length of the laser cavity. However, typical DFB lasers at the wavelength of interest have linewidths that exhibit unacceptable growth when driven at the high currents and powers that are required for the Doppler lidar application. Suppression of this behavior by means of corrugation pitch-modulation (using a detuned central section to prevent intensity peaking in the center of the cavity) is currently under investigation to achieve the required performance goals.

distributed feedback (DFB) laser↗

Magneto-optic detection system with noise cancellation

In a magneto-optic readout system, a polarized beam of light from a laser is subjected to the magneto-optical effect of a magnetic record medium, and then passed through an analyzer which resolves the beam into two orthogonal vector components so oriented that the two components are of equal amplitude when the angle of rotation due to the magneto-optic effect is zero. Separate photodetectors produce two output signals which are proportional to the amplitudes of the vector components. The two output signals are combined in a differential amplifier through separate logarithmic transfer circuits to produce an output signal proportional to the ratio of the two original detector signals.

Lewicki, G. W.↗

Optical detection of blade flutter

The paper examines the capabilities of photoelectric scanning (PES) and stroboscopic imagery (SI) as optical monitoring tools for detection of the onset of flutter in the fan blades of an aircraft gas turbine engine. Both optical techniques give visual data in real time as well as video-tape records. PES is shown to be an ideal flutter monitor, since a single cathode ray tube displays the behavior of all the blades in a stage simultaneously. Operation of the SI system continuously while searching for a flutter condition imposes severe demands on the flash tube and affects its reliability, thus limiting its use as a flutter monitor. A better method of operation is to search for flutter with the PES and limit the use of SI to those times when the PES indicates interesting blade activity.

Nieberding, W. C.↗