Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical diffusers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Phase identification and structure investigation of novel quaternary rare-earth substituted titanates

Novel quaternary lanthanide-substituted oxides of stoichiometry LnxY2-xTi2O7 (where Ln is lanthanum, neodymium, samarium, gadolinium, or ytterbium) were prepared by traditional high-temperature, solid-state techniques and characterized by X-ray powder diffraction. Samples with nominal values of x up to 1.0 were attempted. The well-studied ternary cubic pyrochlore compound yttrium titanium oxide (Y2Ti2O7, space group Fd-3m, Z = 8), served as a parent structural framework in which Ln3+ cations were substituted on the Y3+ site. Laboratory-grade X-ray powder diffraction data revealed pure quaternary pyrochlore phases for LnxY2-xTi2O7 with x ≤ 0.2. Pyrochlore phase purity was verified by Rietveld analysis using high-resolution synchrotron X-ray powder diffraction data when x ≤ 0.2, however, for La3+ substitution specifically, pure quaternary pyrochlore formed at x<0.1. Band gap energies on selected samples were determined using optical diffuse reflectance spectroscopy and showed that these materials can be classified as electrical insulators with indirect band gap energies around 3.7 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

WE-FG-BRA-03: Oxygen Interplay in Hypofractionated Radiotherapy: A Hidden Opportunity

Purpose: Local oxygen during a radiotherapy fraction has been shown to change over a full range of the oxygen enhancement ratio (OER) during the same time scale as the treatment fraction. Interplay with local oxygen is then likely a concern, especially for hypofractionation. Our experiments that show a strong role for metabolic dynamics suggesting one could manipulate this interplay for more efficacious treatments. Methods: Two published experiments are presented with the same human head and neck cancer cell line (UM-SCC-22B). One is a cell-specific in vitro prompt response to a 10 Gy dose of orthovotage radiation using fluorescence lifetime imaging (FLIM), benchmarked with a Seahorse assay. The other in vivo study uses autocorrelation analysis with blood oxygen level dependent magnetic resonance imaging (MRI-BOLD) on xenografts. In vivo results are verified with diffuse optics using spectra fitting and photoacoustic measurements. All these measurements are at high time resolution: sampling is one per minute. Results: Interplay happens when the radiosensitivity modulates at the same time scale as the radiation. These results show dynamics at these time scales. 1. The dominant time scale of the acute hypoxia in cell line xenografts is shown to be on the order of minutes to tens of minutes: similar to a metabolic oscillation known as the ‘glycolytic oscillator.’ 2. The radiation dose itself alters metabolism within minutes to tens of minutes also. Conclusion: These results vary with cell type. There is a possibility that special timing and dose levels could be used for radiation. Gating could be used for maximal oxygen during treatment. There is an analogy to the interplay discussions with tumor motion, except that an oxygen interplay could more likely be patient-specific at a more fundamental level.

60 APPLIED LIFE SCIENCES↗

Deep learning-based temporal deconvolution for photon time-of-flight distribution retrieval

The acquisition of the time of flight (ToF) of photons has found numerous applications in the biomedical field. Over the last decades, a few strategies have been proposed to deconvolve the temporal instrument response function (IRF) that distorts the experimental time-resolved data. However, these methods require burdensome computational strategies and regularization terms to mitigate noise contributions. Herein, we propose a deep learning model specifically to perform the deconvolution task in fluorescence lifetime imaging (FLI). The model is trained and validated with representative simulated FLI data with the goal of retrieving the true photon ToF distribution. Its performance and robustness are validated with well-controlled in vitro experiments using three time-resolved imaging modalities with markedly different temporal IRFs. The model aptitude is further established with in vivo preclinical investigation. Overall, these in vitro and in vivo validations demonstrate the flexibility and accuracy of deep learning model-based deconvolution in time-resolved FLI and diffuse optical imaging.

Pandey, Vikas (ORCID:0000000154771095)↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

A multi-probe thermophoretic soot sampling system for high-pressure diffusion flames

Optical diagnostics and physical probing of the soot processes in high pressure combustion pose challenges that are not faced in atmospheric flames. One of the preferred methods of studying soot in atmospheric flames is in situ thermophoretic sampling followed by transmission electron microscopy imaging and analysis for soot sizing and morphology. The application of this method of sampling to high pressures has been held back by various operational and mechanical problems. In this work, we describe a rotating disk multi-probe thermophoretic soot sampling system, driven by a microstepping stepper motor, fitted into a high-pressure chamber capable of producing sooting laminar diffusion flames up to 100 atm. Innovative aspects of the sampling system design include an easy and precise control of the sampling time down to 2.6 ms, avoidance of the drawbacks of the pneumatic drivers used in conventional thermophoretic sampling systems, and the capability to collect ten consecutive samples in a single experimental run. Proof of principle experiments were performed using this system in a laminar diffusion flame of methane, and primary soot diameter distributions at various pressures up to 10 atm were determined. High-speed images of the flame during thermophoretic sampling were recorded to assess the influence of probe intrusion on the flow field of the flame.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical information transfer through random unknown diffusers using electronic encoding and diffractive decoding

Free-space optical information transfer through diffusive media is critical in many applications, such as biomedical devices and optical communication, but remains challenging due to random, unknown perturbations in the optical path. We demonstrate an optical diffractive decoder with electronic encoding to accurately transfer the optical information of interest, corresponding to, e.g., any arbitrary input object or message, through unknown random phase diffusers along the optical path. This hybrid electronic-optical model, trained using supervised learning, comprises a convolutional neural network-based electronic encoder and successive passive diffractive layers that are jointly optimized. After their joint training using deep learning, our hybrid model can transfer optical information through unknown phase diffusers, demonstrating generalization to new random diffusers never seen before. The resulting electronic-encoder and optical-decoder model was experimentally validated using a 3D-printed diffractive network that axially spans <70λ, where λ = 0.75 mm is the illumination wavelength in the terahertz spectrum, carrying the desired optical information through random unknown diffusers. The presented framework can be physically scaled to operate at different parts of the electromagnetic spectrum, without retraining its components, and would offer low-power and compact solutions for optical information transfer in free space through unknown random diffusive media.

36 MATERIALS SCIENCE↗

An Optical Spectrum of the Diffuse Galactic Light from BOSS and IRIS

We present a spectrum of the diffuse Galactic light (DGL) between 3700 and 10,000 Å, obtained by correlating optical sky intensity with far-infrared dust emission. We use nearly 250,000 blank-sky spectra from BOSS/SDSS-III together with IRIS-reprocessed maps from the IRAS satellite. The larger sample size compared to SDSS-II results in a factor-of-2 increase in signal to noise. We combine these data sets with a model for the optical/far-infrared correlation that accounts for self-absorption by dust. The spectral features of the DGL agree remarkably well with the features present in stellar spectra. There is evidence for a difference in the DGL continuum between the regions covered by BOSS in the northern and southern Galactic hemispheres. We interpret the difference at red wavelengths as the result of a difference in stellar populations, with mainly old stars in both regions, but a higher fraction of young stars in the south. There is also a broad excess in the southern DGL spectrum over the prediction of a simple radiative transfer model, without a clear counterpart in the north. We interpret this excess, centered at ~6500 Å, as evidence for luminescence in the form of extended red emission. The observed strength of the 4000 Å break indicates that at most ~7% of the dust-correlated light at 4000 Å can be due to blue luminescence. Our DGL spectrum provides constraints on dust scattering and luminescence, independent of measurements of extinction.

79 ASTRONOMY AND ASTROPHYSICS↗

Indistinguishable telecom band photons from a single Er ion in the solid state

Atomic defects in the solid state are a key component of quantum repeater networks for long-distance quantum communication1. Recently, there has been significant interest in rare earth ions, in particular Er 3+ for its telecom band optical transition that allows long-distance transmission in optical fibres. However, the development of repeater nodes based on rare earth ions has been hampered by optical spectral diffusion, precluding indistinguishable single-photon generation. Here, we implant Er 3+ into CaWO 4 , a material that combines a non-polar site symmetry, low decoherence from nuclear spins and is free of background rare earth ions, to realize significantly reduced optical spectral diffusion. For shallow implanted ions coupled to nanophotonic cavities with large Purcell factor, we observe single-scan optical linewidths of 150 kHz and long-term spectral diffusion of 63 kHz, both close to the Purcell-enhanced radiative linewidth of 21 kHz. This enables the observation of Hong–Ou–Mandel interference between successively emitted photons with a visibility of V = 80(4)%, measured after a 36 km delay line. We also observe spin relaxation times T 1,s = 3.7 s and T 2,s > 200 μs, with the latter limited by paramagnetic impurities in the crystal instead of nuclear spins. Furthermore, this represents a notable step towards the construction of telecom band quantum repeater networks with single Er 3+ ions.

42 ENGINEERING↗

Formation and fractionation of CO (carbon monoxide) in diffuse clouds observed at optical and radio wavelengths

We modeled H{sub 2} and CO formation incorporating the fractionation and selective photodissociation affecting CO when A{sub V} ≲ 2 mag. UV absorption measurements typically have N({sup 12}CO)/N({sup 13}CO) ≈ 65 that are reproduced with the standard UV radiation and little density dependence at n(H) ≈ 32–1024 cm{sup −3}: densities n(H) ≲ 256 cm{sup −3} avoid overproducing CO. Sightlines observed in millimeter wave absorption and a few in UV show enhanced {sup 13}CO by factors of two to four and are explained by higher n(H) ≳ 256 cm{sup −3} and/or weaker radiation. The most difficult observations to understand are UV absorptions having N({sup 12}CO)/N({sup 13}CO) > 100 and N(CO) ≳ 10{sup 15} cm{sup −2}. Plots of W{sub CO} versus N(CO) show that W{sub CO} remains linearly proportional to N(CO) even at high opacity owing to sub-thermal excitation. {sup 12}CO and {sup 13}CO have nearly the same curve of growth so their ratios of column density/integrated intensity are comparable even when different from the isotopic abundance ratio. For n(H) ≳ 128 cm{sup −3}, plots of W{sub CO} versus N(CO) are insensitive to n(H), and W{sub CO}/N(CO) ≈ 1 K km s{sup −1}/(10{sup 15} CO cm{sup −2}); this compensates for small CO/H{sub 2} to make W{sub CO} more readily detectable. Rapid increases of N(CO) with n(H), N(H), and N(H{sub 2}) often render the CO bright, i.e., a small CO-H{sub 2} conversion factor. For n(H) ≲ 64 cm{sup −3}, CO enters the regime of truly weak excitation, where W{sub CO} ∝ n(H)N(CO). W{sub CO} is a strong function of the average H{sub 2} fraction and models with W{sub CO} = 1 K km s{sup −1} fall in the narrow range of 〈f{sub H{sub 2}}〉 0.65–0.8 or 〈f{sub H{sub 2}}〉 0.4–0.5 at W{sub CO} 0.1 K km s{sup −1}. The insensitivity of easily detected CO emission to gas with small 〈f{sub H{sub 2}}〉 implies that even deep CO surveys using broad beams may not discover substantially more emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical properties change in Te diffused As{sub 50}Se{sub 50} chalcogenide thin film

In the present report, we present the effect of Te diffusion into As{sub 50}Se{sub 50} thin film which changes the optical properties. The Te/As{sub 50}Se{sub 50} film was irradiated by a laser beam of 532 nm to study the diffusion mechanism due to photo induced effect. The As{sub 50}Se{sub 50}, Te/As{sub 50}Se{sub 50} films show a completely amorphous nature from X-ray diffraction study. A non direct transition was found for these films on the basis of optical transmission data carried out by Fourier Transform infrared Spectroscopy. The optical bandgap is found to be decreased with Te deposition and photo darkening phenomena is observed for the diffused film. The change in the optical constants are well supported by the corresponding change in different types of bonds which are being studied by X-ray photoelectron spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New theory of diffusive and coherent nature of optical wave via a quantum walk

We propose a new theory on a relation between diffusive and coherent nature in one dimensional wave mechanics based on a quantum walk. It is known that the quantum walk in homogeneous matrices provides the coherent property of wave mechanics. Using the recent result of a localization phenomenon in a one-dimensional quantum walk (Konno, 2010), we numerically show that the randomized localized matrices suppress the coherence and give diffusive nature. - Highlights: • A relation between diffusive and coherent nature of wave is obtained. • A rigorous decoherent process is observed in quantum walk. • Quantum walk for a point-process is numerically considered. • Transfer matrix theory with S-matrix in optics is connected with quantum walk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Optical Absorption Studies of Point Defect Kinetics and Thermodynamics in Oxide Thin Films

The authors discuss the use of in situ optical absorption to probe point defect equilibria and kinetics in oxides, with particular attention to thin films and high-temperature measurements evaluating changes in oxygen content. The introduction notes the effect of point defects on oxide behavior, including differences in thin films versus bulk materials, and describes methods to evaluate point defect equilibria and kinetics; advantages of optical absorption among these methods are highlighted. Section 2 provides an overview of how optical absorption and point defect concentrations are related, including various possible structural and electronic origins of defect-mediated absorption changes corresponding to oxygen content changes. Section 3 traces the development of historical understanding of optical absorption in nonstoichiometric oxides and emergence of thin film applications and measurement approaches that resulted. Section 4 details the procedure for determining surface exchange coefficients from optical transmission relaxation measurements and provides specific examples of how this approach uniquely has enabled new insights into thin film surface exchange behavior with and without current collectors. Section 5 provides examples of optically derived diffusivity measurements and comparisons of bulk and thin film defect equilibria. Section 7 outlines potential opportunities and future developments in this area, and Section 7 concludes the manuscript.

36 MATERIALS SCIENCE↗

Concentrator photovoltaic module architectures with capabilities for capture and conversion of full global solar radiation

Significance Concentrator photovoltaic (CPV) systems, wherein light focuses onto multijunction solar cells, offer the highest efficiencies in converting sunlight to electricity. The performance is intrinsically limited, however, by an inability to capture diffuse illumination, due to narrow acceptance angles of the concentrator optics. Here we demonstrate concepts where flat-plate solar cells mount onto the backplanes of the most sophisticated CPV modules to yield an additive contribution to the overall output. Outdoor testing results with two different hybrid module designs demonstrate absolute gains in average daily efficiencies of between 1.02% and 8.45% depending on weather conditions. The findings suggest pathways to significant improvements in the efficiencies, with economics that could potentially expand their deployment to a wide range of geographic locations.

14 SOLAR ENERGY↗

Scintillator based fiber optic plate for neutron imaging applications and the like

A chalcopyrite, colquiriite, neutron absorber loaded glass, or plastic scintillator based fiber optic plate for use in a neutron imaging system, including: a plurality of optical fiber segments disposed side-by-side adjacent to one another in a parallel array; and a binder material disposed between and coupling the plurality of optical fiber segments together. A diffuse reflective material is optically coupled to the plurality of first ends of the plurality of optical fiber segments. An optical detector device is optically coupled to the plurality of second ends of the plurality of optical fiber segments opposite the diffuse reflective material. Optionally, the fiber optic plate further includes a diffuse reflective material disposed one or more of on an exterior surface of each of the plurality of optical fiber segments and between the plurality of optical fiber segments.

42 ENGINEERING↗

Laser-Induced Spectral Diffusion of T Centers in Silicon Nanophotonic Devices

Color centers in silicon are emerging as spin-photon interfaces operating at telecommunication wavelengths. The nanophotonic device integration of silicon color centers via ion implantation leads to significant optical-linewidth broadening, which makes indistinguishable photon generation challenging. Here, we study the optical spectral diffusion of T centers in a silicon photonic crystal cavity. We investigate the linewidth-broadening timescales and origins by measuring the temporal correlations of the resonance frequency under different conditions. Spectral hole-burning measurements reveal no spectral broadening at short timescales from 102 ns to 725 ns. We probe broadening at longer timescales using a check pulse to herald the T-center frequency and a probe pulse to measure the frequency after a wait time. The optical resonance frequency is stable up to 3 ms in the dark. Laser pulses below the silicon band gap applied during the wait time lead to linewidth broadening. Our observations establish laser-induced processes as the dominant spectral-diffusion mechanism for T centers in devices and inform materials and feedback strategies for indistinguishable photon generation.

Zhang, Xueyue↗

Dependence of Catalytic Activity of Nanocrystalline Nickel Ferrite on Its Structural, Morphological, Optical, and Magnetic Properties in Aerobic Oxidation of Benzyl Alcohol

Nanocrystalline nickel ferrite spinel, NiFe{sub 2}O{sub 4}, with average crystallite size of 23.98 and 19.76 nm were successfully synthesized under sol–gel method (SGM) and microwave method (MM) conditions without using any surfactant or otherwise structure-directing (oxalic acid as the fuel) agents. Powder x-ray diffraction, high-resolution scanning electron microscopies indicate that single-crystalline nanoparticles are well-dispersed in the nickel ferrite. The elemental investigation of nickel ferrite was attained from energy-dispersive x-ray (EDX) analysis. Their optical properties (diffuse reflectance spectroscopy and photoluminescence) were described in depth in relative with their structural characteristics and the functionalization performance. After the magnetic measurements, samples showed a ferromagnetic behavior and the magnetization (Ms) value of NiFe{sub 2}O{sub 4}-MM is higher, i.e., 59.33 emu/g than NiFe{sub 2}O{sub 4}-SGM (50.12 emu/g). The magnetic properties could be further changed by controlling the shape, size, and crystallinity of the nanocrystals. Determination of concentration NiFe{sub 2}O{sub 4} ions’ average number of atoms per nanoparticle was calculated by the new method as follows. Consequently, the designated procedure improves catalytic activity of nickel ferrite powders in aerobic oxidation of benzyl alcohol and catalytic reactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗