TRACER-BC2-SP2 Field Campaign Report

The focus of this project was to assess black carbon and brown carbon aerosol in Houston, Texas during the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility Tracking Aerosol Convection Interactions Experiment (TRACER) through the co-located deployment of a single-particle soot photometer (SP2) with the University of Houston/Baylor aerosol optical instrumentation in the Texas (BC)2 network in and around Houston. The deployment of the SP2 enables us to expand the spatial assessment of black carbon (BC) in Houston during TRACER by permitting a more thorough characterization of BC, including sources, transport, and potential processing. BC is well known to undergo physical and chemical changes during local and long-range transport that will impact its optical properties. By deploying multiple SP2s in the Houston area, the impacts of local and long-range transport can be assessed. The TRACER-BC2-SP2 campaign will expand spatial and temporal characterization of BC in the Houston area during TRACER and link the TRACER-carbon analysis to ongoing black and brown carbon monitoring (Texas [BC]2 network) in Houston.

54 ENVIRONMENTAL SCIENCES↗

Multiwavelength Observations of the Blazar VER J0521+211 during an Elevated TeV Gamma-Ray State

We report on a long-lasting, elevated gamma-ray flux state from VER J0521+211 observed by VERITAS, MAGIC, and Fermi-LAT in 2013 and 2014. The peak integral flux above 200 GeV measured with the nightly binned light curve is (8.8 ± 0.4) × 10 –7 photons m –2 s –1 , or ~37% of the Crab Nebula flux. Multiwavelength observations from X-ray, UV, and optical instruments are also presented. A moderate correlation between the X-ray and TeV gamma-ray fluxes was observed, and the X-ray spectrum appeared harder when the flux was higher. Using the gamma-ray spectrum and four models of the extragalactic background light (EBL), a conservative 95% confidence upper limit on the redshift of the source was found to be z ≤ 0.31. Unlike the gamma-ray and X-ray bands, the optical flux did not increase significantly during the studied period compared to the archival low-state flux. The spectral variability from optical to X-ray bands suggests that the synchrotron peak of the spectral energy distribution (SED) may become broader during flaring states, which can be adequately described with a one-zone synchrotron self-Compton model varying the high-energy end of the underlying particle spectrum. The synchrotron peak frequency of the SED and the radio morphology of the jet from the MOJAVE program are consistent with the source being an intermediate-frequency-peaked BL Lac object.

79 ASTRONOMY AND ASTROPHYSICS↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging

Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging in real time, thus falling short in dynamic temperature mapping. Here, we report video-rate upconversion temperature sensing in wide field using single-shot photoluminescence lifetime imaging thermometry (SPLIT). Developed from a compressed-sensing ultrahigh-speed imaging paradigm, SPLIT first records wide-field luminescence intensity decay compressively in two views in a single exposure. Then, an algorithm, built upon the plug-and-play alternating direction method of multipliers, is used to reconstruct the video, from which the extracted lifetime distribution is converted to a temperature map. Using the core/shell NaGdF 4 :Er 3+ ,Yb 3+ /NaGdF 4 upconverting nanoparticles as the lifetime-based temperature indicators, we apply SPLIT in longitudinal wide-field temperature monitoring beneath a thin scattering medium. SPLIT also enables video-rate temperature mapping of a moving biological sample at single-cell resolution.

47 OTHER INSTRUMENTATION↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences↗

Smoothing tool design and performance during subaperture glass polishing

During subaperture tool grinding and polishing, overlaps of the tool influence function can result in undesirable mid-spatial frequency (MSF) errors in the form of surface ripples, which are often corrected using a smoothing polishing step. Here, in this study, flat multi-layer smoothing polishing tools are designed and tested to simultaneously (1) reduce or remove MSF errors, (2) minimize surface figure degradation, and (3) maximize the material removal rate. A time-dependent convergence model in which spatial material removal varies with a workpiece-tool height mismatch, combined with a finite element mechanical analysis to determine the interface contact pressure distribution, was developed to evaluate various smoothing tool designs as a function of tool material properties, thicknesses, pad textures, and displacements. An improvement in smoothing tool performance is achieved when the gap pressure constant, $\overline{h}$ (which describes the inverse rate at which the pressure drops with a workpiece-tool height mismatch), is minimized for smaller spatial scale length surface features (namely, MSF errors) and maximized for large spatial scale length features (i.e., surface figure). Five specific smoothing tool designs were experimentally evaluated. A two-layer smoothing tool using a thin, grooved IC1000 polyurethane pad (with a high elastic modulus, E pad =360 MPa ), thicker blue foam (with an intermediate modulus, E foam =5.3 MPa ) underlayer, and an optimized displacement (d t =1 mm ) provided the best overall performance (namely, high MSF error convergence, minimal surface figure degradation, and high material removal rate).

47 OTHER INSTRUMENTATION↗

New method for the determination of photoabsorption from transmittance measurements in the extreme ultraviolet

We have developed a new method for the determination of photoabsorption at extreme ultraviolet wavelengths longer than 20 nm, where reliable refractive index values are sparse or non-existent. Our method overcomes the obstacle of multiple reflections that occur inside thin films in this spectral range, which up until now has prevented the accurate determination of photoabsorption from transmittance measurements. We have derived a mathematical expression that is independent of internal reflection amplitudes, while taking advantage of the transmittance oscillations stemming from such reflections. The method is validated on measurements of aluminum thin films. This advance will enable accurate refractive index values for many important materials for optical instrumentation, thus facilitating high-priority research on topics including coherent light sources, planetary and solar physics, and semiconductor manufacturing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Computer Vision Techniques Used to Monitor the Alignment of Cavities and Solenoids in the PIP-II Prototype SSR1 Cryomodule

The alignment of the SRF PIP-II string components is studied as the acceptable beam deflection, offset and defocusing, which may otherwise cause beam loss. Simulations and measurements established that the maximum deviation of the beam pipe from the reference orbit should not exceed a small fraction of the beam aperture. To observe the translations and rotations of each single component within the cryomodule, optical instruments (H-BCAM) surveying highly reflective targets, installed in the internal assembly of the module were used. The alignment monitoring concept for the PIP II SSR1 prototype cryomodule, along with relevant measurements of the components’ position monitoring during coldmass cooldown is presented in this contribution. This development paves the way to new computer vision applications in the field of cryomodule assemblies in cleanroom environment, in which robotically-assisted operations have the potential to dramatically reduce the risk of chemical and particulate contamination.

43 PARTICLE ACCELERATORS↗

Expanded Capabilities and Opportunities for Virtual Beamline Code

In the 25 years since LLNL broke ground on the National Ignition Facility (NIF) - a cornerstone of the National Nuclear Security Administration’s Stockpile Stewardship Program - the NIF and Photon Science (NIF&PS) Directorate has steadily pushed the boundaries of laser physics, nonlinear optics, and photonics in service of inertial confinement fusion experiments, and advanced photon sources development. Beyond the 192 beamlines of the primary laser facility with its world-record energy and fusion yields, NIF&PS capabilities have expanded to include chirped-pulse amplification, kilojoule petawatt-class short-pulse systems to generate hard x-ray radiographic probes, high-average power lasers as secondary sources for generation or wake field particle acceleration along directed energy applications, and other scientific pursuits. The Computing Directorate partners with NIF&PS on numerous projects and technologies from diagnostic measurements and high performance control systems to data analysis, information technology infrastructure, and scientific simulation code development. “This strong collaboration enables cutting-edge science, particularly with regard to physics-based modeling and simulation,” says physicist Jean-Michel Di Nicola. One crucial capability for NIF&PS is the Virtual Beamline (VBL) laser simulation code. It can model all the major laser physics and technology involved in the design optimization, commissioning, and operations of advanced laser architectures from tabletop to NIF-scale. VBL provides researchers with high-fidelity models and high-resolution calculations of laser performance predictions—including for the entire NIF laser system, the Advanced Radiographic Capability, parts of the High Repetition-Rate Advanced Petawatt Laser System laser delivered to the Czech Republic, and the Optical Science Laser. After more than two decades of experimentally verified physics and computing enhancements, this unique workhorse code is wrapping up another major milestone: migration from Java to C++ with a flurry of user interface and optimization features, as well as laser physics and high-resolution enhancements thanks to parallel execution on Livermore Computing platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of the thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery efficiency, and the acid dew point is a key parameter for this optimization. In this work, we analyze and discuss the theory of the sulfuric acid condensation process and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface, and the surface temperature of the window is slowly decreased until condensation is first observed, yielding an accurate measurement of the dew point. The basis of the instrument is that a collimated beam from a diode laser generates scattered light when encountering surface condensate, and a sophisticated array detector is used to sensitively monitor the light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, we propose a calibration system based on a liquid bubbler, which can generate a stable gas flow with known sulfuric acid dew point, to test the dew point meter. Test results show that the dew point meter can accurately measure the acid dew point over a wide range.

Cheng, Mao↗

TAP Absorption Coefficients

The data set of aerosol light absorption coefficients were collected by two tricolor absorption photometers (TAP; Brechtel Model 2901) in July and August, 2022 during the TRACER field campaign at the AMF1 site in La Porte, Texas. One of the TAPs at the La Porte site was an RGB model measuring aerosol light absorption at 652, 528, 467 nm, and the other was an UV model measuring absorption at the same red and green wavelengths but at an additional UV wavelength at 365 nm. Since TAP is a filter-based optical instrument using 47-mm glass fiber filters, the output absorption coefficients are corrected for filter loading and scattering effects based on a correction scheme developed in "Comment on ‘Calibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols’" by John A. Ogren 2010. This uploaded dataset contains both the Ogren corrected absorption coefficients (column header with “ Ogren”) and the raw absorption coefficients without the correction scheme (column header with “_ Raw”). During the field campaign, the two TAPs operated side by side with a shared inlet at a flow rate of 2 lpm. In July, no inlet impactors/cyclones were installed; however, beginning in August, a PM2.5 cyclone inlet was installed.

54 ENVIRONMENTAL SCIENCES↗

Network of Modified Portable Optical Particle Spectrometers Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s portable optical particle spectrometer (POPS) network (Figure 1) provides an aerosol size distribution spectrum from 150 nm to 5 μm in 16 logarithmically spaced bins. The data emanating from this network of up to four matching POPS in weatherproof enclosures comprises one-minute averages of the aerosol size and number spectrum and the co-located temperature and relative humidity. The total particle concentration and sample flow rate are also provided. The sample stream is not dried before its measurement. Two size spectra are provided: the default size distribution corresponds to the calibration using polystyrene latex spheres (PSL), while the second size distribution corresponds to the calibration using size-selected dry ammonium sulfate aerosol. The principal scientific application of the data provided by the ARM POPS is to determine the aerosol size distribution across a region in three disparate locations – the size distribution is broadly relevant to studies of pollution and of conditions in the boundary layer. A high particle concentration can be an indicator of unhealthy levels of pollution; the dispersion of particles in the atmosphere is a predictor of long-range visibility; and particles serve as collectors of condensing gases including water vapor, and thus are a factor in the formation and properties of fogs and clouds, and in the initiation of precipitation.

54 ENVIRONMENTAL SCIENCES↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

Optical Classification of Lower Amazon Waters Based on In Situ Data and Sentinel-3 Ocean and Land Color Instrument Imagery

Optical water types (OWTs) were identified from an in situ dataset of concomitant biogeochemical and optical parameters acquired in the Amazon River and its tributaries, in the Lower Amazon region, at different hydrological conditions from 2014 to 2017. A seasonal bio-optical characterization was performed. The k-means classification was applied to the in situ normalized reflectance spectra (rn(λ)), allowing the identification of four OWTs. An optical index method was also applied to the rn(λ) defining the thresholds of the OWTs. Next, level-3 Sentinel-3 Ocean and Land Color Instrument images representative of the seasonal discharge conditions were classified using the identified in situ OWTs as reference. The differences between Amazon River and clearwater tributary OWTs were dependent on the hydrological dynamics of the Amazon River, also showing a strong seasonal variability. Each OWT was associated with a specific bio-optical and biogeochemical environment assessed from the corresponding absorption coefficient values of colored dissolved organic matter (aCDOM) and particulate matter (ap), chlorophyll-a and suspended particulate matter (SPM) concentrations, and aCDOM/ap ratio. The rising water season presented a unique OWT with high SPM concentration and high relative contribution of ap to total absorption compared to the other OWTs. This bio-optical characterization of Lower Amazon River waters represents a first step for developing remote sensing inversion models adjusted to the optical complexity of this region.

54 ENVIRONMENTAL SCIENCES↗

Wide-field probing of silica laser-induced damage precursors by photoluminescence photochemical quenching

Here, we describe a wide-field approach to probe transient changes in photoluminescence (PL) of defects on silica surfaces. This technique allows simultaneous capture of spatially resolved PL with spontaneous quenching behavior. We attribute the quenching of PL intensity to photochemical reactions of surface defects and/or subsurface fractures with ambient molecules. Such quenching curves can be accurately reproduced by our theoretical model using two quenchable defect populations with different reaction rates. The fitting parameters of our model are spatially correlated to fractures in silica where point defects and mechanical stresses are known to be present, potentially indicating regions prone to laser-induced damage growth. We believe that our approach allows rapid spatial resolved identification of damage prone morphology, providing a new pathway to fast, non-destructive predictions of laser-induced damage growth.

47 OTHER INSTRUMENTATION↗