Optical measurement of the new Saturn gas switch as a timing fiducial.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Poster describing progress in SOFAST 2.0.
Abstract not provided.
Abstract not provided.
Abstract not provided.
A pulse analysis system or method includes a frequency filter that receives an ultrafast pulse under test and disperses the pulse under test over a frequency range. The frequency filter separates the pulse under test into component frequency slices and provides the frequency slices to a detector coupled to a digitizer, which processes the digitized signal and collects a sonogram characteristic of the pulse under test. The frequency slices are arranged to overlap. Ptychography is performed on the sonogram to obtain characteristics of the pulse under test.
A pulse analysis system or method includes a frequency filter that receives an ultrafast pulse under test and disperses the pulse under test over a frequency range. The frequency filter separates the pulse under test into component frequency slices and provides the frequency slices to a detector coupled to a digitizer, which processes the digitized signal and collects a sonogram characteristic of the pulse under test. The frequency slices are arranged to overlap. Ptychography is performed on the sonogram to obtain characteristics of the pulse under test.
Spectroscopic identification of aerosolized chemical threats is challenging due to the complex nature of the photon/particle interaction, as well as the diversity of possible particle sizes, morphologies, and compositions. Constructing a database of laboratory - measured transmittance spectra that covers each permutation is not practical. However, calculation of the spectra using the measured optical constants as a function of wavenumber, n(?) and k(?), for each of the liquids and/or solids composing the aerosol particles provides a viable alternative. These synthetic spectra (vis-à-vis laboratory-measured spectra) can be used to identify chemicals of interest and subtract out background interferents in field measurements. Using a well-established multiple pathlength approach, we measure the optical constants n/k for liquids that may be found as chemical species of interest or common background interferents aerosolized in plumes. These measurements are also used to generate several test case aerosol synthetic spectra.
Abstract Aerosol jet printing is a popular digital additive manufacturing method for flexible and hybrid electronics, but it lacks sophisticated real‐time process control schemes that would enable more widespread adoption in manufacturing environments. Here, an optical measurement system is introduced to track the aerosol density upstream of the printhead. The measured optical extinction, combined with the aerosol flow rate, is directly related to deposition rate and accurately predicts functional materials properties such as the electrical resistance of printed graphene films. This real‐time system offers a compelling solution for process drift and batch‐to‐batch variability, rendering it a valuable tool for both real‐time control of aerosol jet printing and fundamental studies of the underlying process science.
Indium-doped cadmium oxide (In:CdO) thin films exhibit tunable epsilon-near-zero (ENZ) modal frequencies across a wide spectral range, bridging the mid-wave and near-infrared (IR). In:CdO thin films are prepared by reactive cosputtering from metallic Cd and In targets using high-power impulse magnetron sputtering (HiPIMS) and radio frequency sputtering, respectively. Using this approach, CdO thin films with carrier concentrations ranging from 2.3 × 10 19 to 4.0 × 10 20 cm –3 and mobilities ranging from 300 to 400 cm 2 /Vs are readily achieved. UV-VIS absorption spectra are used to measure optical bandgap, revealing a Burstein-Moss shift of 0.58 eV across the doping range investigated. In this work, optical measurements demonstrate the tunability of near-perfect plasmonic ENZ absorption across the mid-wave and into the near-IR spectral ranges by controlling the carrier concentration through doping, while tuning the film thickness for impedance matching. In comparison to other dopants that can be introduced to HiPIMS-deposited CdO, In offers the largest range of carrier concentrations while maintaining high mobility, thus allowing for the widest accessibility of the IR spectrum of a single plasmonic material grown by sputtering.
The drone-based Non-Intrusive Optical (NIO) Technology has been developed at NREL to allow for efficient and automated optical characterization of heliostats in Concentrating Solar Power (CSP) plants. For this project, the technology will be developed into a commercial tool package, including software and user-interface (UI), operations manual, and training and support services. The project team will partner with Tietronix to perform market assessment and stakeholder engagement, develop the tool package and business model, and perform data collection and analysis to demonstrate and refine the capabilities for use at a commercial plant. The team will collaborate with a commercial plant to conduct the data collection operations and provide optical error deliverables. The goal of the project is to advance the commercialization of the technology to a stage where a beta version can be demonstrated at additional commercial plants and developed into a licensable product.
Knowledge of the bulk optical constants n and k of solids or liquids allows researchers to accurately predict the absorption, reflection, and scattering properties of materials for different physical forms. Indeed, chemically complex materials such as minerals can have an almost limitless variety of morphologies, particle sizes, shapes, and compositions, but the optical properties of such species can be predicted if the optical constants are known. For species such as minerals, however, there can be additional challenges due to e.g. hydration or dehydration during the course of the optical constants measurement. Here, we describe the protocols to obtain the bulk optical constants n and k of uranium-bearing minerals and ores such as uraninite or autunite. If quality n and k data are at hand, the (infrared) reflectance spectra can be predicted for different particle sizes and morphologies and the modeling results for various scenarios can be derived.
Reflected computer vision targets are a powerful tool for measurement of mirror surface shape, with several important advantages over traditional fringe deflectometry methods. This method was first presented in 2021 and has undergone significant improvement and demonstration since. We describe a new baseline system using reflected computer vision targets, and present results from a large-scale measurement campaign conducted on both commercial heliostats and test mirrors in the laboratory. Calibration of the measurement system with photogrammetry allows for accurate measurement without careful control of target shape or camera position. Overall, the results show that a baseline setup using this method achieves measurement uncertainties in the slope error root-mean-square less than ±0.11 milliradian due to a series of repeatability conditions, varying sample position, rotation, lighting, camera settings, and system rebuild and recalibration. We present a detailed description of the setup, the results generated by this measurement tool, repeated measurement results, and the strengths and limitations of this metrology system.
Since 2021, NREL has been developing a system to measure heliostats by measuring the deflection of printed computer vision targets, called the Reflected Target Non-intrusive Assessment (ReTNA) [6], [7]. While this system will have lower resolution than a fringe deflectometry system, it has several important advantages that make it a complimentary technology: 2D surface slope measurement can be generated from a single image, it can operate in ambient lighting, target points can be directly located in 3D space with photogrammetry allowing for a non-flat target, and it's well suited to using a smaller target, and multiple images to measure larger optical surfaces. ReTNA has undergone several significant changes and improvements, described below. This talk will summarize new system layouts designed for commercial use, new computer vision algorithms used to automate the analysis process and validation campaigns for the ReTNA software.
Interference between crossed femtosecond lasers can drive spatially varying ionization, producing a high-flux plasma optic. Here, we measure the plasma and optical properties of an ionization grating in air as it redirects a millijoule-scale probe beam.
Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.