Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical sorting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Detection of Objects Hidden in Highly Scattering Media Using Time-Gated Imaging Methods

Non-intrusive and non-invasive optical imaging techniques has generated great interest among researchers for their potential applications to biological study, device characterization, surface defect detection, and jet fuel dynamics. Non-linear optical parametric amplification gate (NLOPG) has been used to detect back-scattered images of objects hidden in diluted Intralipid solutions. To directly detect objects hidden in highly scattering media, the diffusive component of light needs to be sorted out from early arrived ballistic and snake photons. In an optical imaging system, images are collected in transmission or back-scattered geometry. The early arrival photons in the transmission approach, always carry the direct information of the hidden object embedded in the turbid medium. In the back-scattered approach, the result is not so forth coming. In the presence of a scattering host, the first arrival photons in back-scattered approach will be directly photons from the host material. In the presentation, NLOPG was applied to acquire time resolved back-scattered images under the phase matching condition. A time-gated amplified signal was obtained through this NLOPG process. The system's gain was approximately 100 times. The time-gate was achieved through phase matching condition where only coherent photons retain their phase. As a result, the diffusive photons, which were the primary contributor to the background, were removed. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

Galland, Pierre A.↗

Evaluation of an electro-optic remote displacement measuring system

An instrumentation system to provide a noncontact method for measurement of target positions was evaluated. The system employs two electro-optic camera units which give stereo information for use in determining three dimensional target locations. Specially developed, infrared sensitive photodetectors are used in the cameras to sense radiation from light emitting diode targets. Up to 30 of these targets can be monitored with a sampling rate of 312 Hz per target. An important part of the system is a minicomputer which is used to collect the camera data, sort it, make corrections for distortions in the electro-optic system, and perform the necesssary coordinate transformations. If target motions are restricted to locations in a plane which is perpendicular to a camera's optical axis, the system can be used with just one camera. Calibrations performed in this mode characterize accuracies in single camera operation. This information is also useful in determination of single camera contributions to total system errors. For this reason the system was tested in both the single camera and two camera (stereo) modes of operation.

Monteith, J. H.↗

Inventions Utilizing Microfluidics and Colloidal Particles

Several related inventions pertain to families of devices that utilize microfluidics and/or colloidal particles to obtain useful physical effects. The families of devices can be summarized as follows: (1) Microfluidic pumps and/or valves wherein colloidal-size particles driven by electrical, magnetic, or optical fields serve as the principal moving parts that propel and/or direct the affected flows. (2) Devices that are similar to the aforementioned pumps and/or valves except that they are used to manipulate light instead of fluids. The colloidal particles in these devices are substantially constrained to move in a plane and are driven to spatially order them into arrays that function, variously, as waveguides, filters, or switches for optical signals. (3) Devices wherein the ultra-laminar nature of microfluidic flows is exploited to effect separation, sorting, or filtering of colloidal particles or biological cells in suspension. (4) Devices wherein a combination of confinement and applied electrical and/or optical fields forces the colloidal particles to become arranged into three-dimensional crystal lattices. Control of the colloidal crystalline structures could be exploited to control diffraction of light. (5) Microfluidic devices, incorporating fluid waveguides, wherein switching of flows among different paths would be accompanied by switching of optical signals.

Marr, David W.↗

Diffraction Effects in a Grating Spectrometer

This paper describes a numerical study of diffraction effects in the AIRES optical system using GLAD by Applied Optics Research. AIRES (or Airborne Infrared Echelle Spectrometer) employs two gratings in series. The small, first-order (i.e., predisperser) grating sorts orders for the large, high-order echelle grating, thus providing moderately high spectral resolution over 3.6 octaves in wavelength. The AIRES' optical design includes three field stops (i.e., a circular aperture and two long, narrow slits) and four pupil stops. A detailed diffraction analysis is required to evaluate critical trade-offs between spectral resolution, optical throughput, detector background, scattered light, and system size and weight. Such an analysis must consider diffraction effects at the pupil stops (edge diffraction), at the field stops (spatial filtering), and at intermediate positions where other optical elements are located. The effects of slit width, slit length, oversizing of the second slit relative to the first, baffling at the Lyot stop and subsequent pupil stops, and the necessity for oversizing other optical elements are presented and discussed. It is found that for narrow slits, the downstream energy distribution is significantly broadened relative to that for large slits, where telescope diffraction dominates, leading to significantly more light loss than anticipated, unless other key optical elements are oversized. The importance of performing a proper diffraction analysis is emphasized and the suitability of GLAD for this task is discussed.

Haas, Michael R.↗

Spectral evidence of size dependent space weathering processes on asteroid surfaces

Most compositional characterizations of the minor planets are derived from analysis of visible and near-infrared reflectance spectra. However, such spectra are derived from light which has only interacted with a very thin surface layer. Although regolith processes are assumed to mix all near-surface lithologic units into this layer, it has been proposed that space weathering processes can alter this surface layer to obscure the spectral signature of the bedrock lithology. It has been proposed that these spectral alteration processes are much less pronounced on asteroid surfaces than on the lunar surface, but the possibility of major spectral alteration of asteroidal optical surfaces has been invoked to reconcile S-asteroids with ordinary chondrites. The reflectance spectra of a large subset of the S-asteroid population have been analyzed in a systematic investigation of the mineralogical diversity within the S-class. In this sample, absorption band depth is a strong function of asteroid diameter. The S-asteroid band depths are relatively constant for objects larger than 100 km and increase linearly by factor of two toward smaller sizes (approximately 40 km). Although the S-asteroid surface materials includes a diverse variety of silicate assemblages, ranging from dunites to basalts, all compositional subtypes of the S-asteroids conform to this trend. The A-, R-, and V-type asteroids which are primarily silicate assemblages (as opposed to the metal-silicate mixtures of most S-asteroids) follow a parallel but displaced trend. Some sort of textural or regolith equilibrium appears to have been attained in the optical surfaces of asteroids larger than about 100 km diameter but not on bodies below this size. The relationships between absorption band depth, spectral slope, surface albedo and body size provide an intriguing insight into the nature of the optical surfaces of the S-asteroids and space weathering on these objects.

Gaffey, M. J.↗

Advanced Video Guidance Sensor (AVGS) Development Testing

NASA's Marshall Space Flight Center was the driving force behind the development of the Advanced Video Guidance Sensor, an active sensor system that provides near-range sensor data as part of an automatic rendezvous and docking system. The sensor determines the relative positions and attitudes between the active sensor and the passive target at ranges up to 300 meters. The AVGS uses laser diodes to illuminate retro-reflectors in the target, a solid-state camera to detect the return from the target, and image capture electronics and a digital signal processor to convert the video information into the relative positions and attitudes. The AVGS will fly as part of the Demonstration of Autonomous Rendezvous Technologies (DART) in October, 2004. This development effort has required a great deal of testing of various sorts at every phase of development. Some of the test efforts included optical characterization of performance with the intended target, thermal vacuum testing, performance tests in long range vacuum facilities, EMI/EMC tests, and performance testing in dynamic situations. The sensor has been shown to track a target at ranges of up to 300 meters, both in vacuum and ambient conditions, to survive and operate during the thermal vacuum cycling specific to the DART mission, to handle EM1 well, and to perform well in dynamic situations.

Howard, Richard T.↗

A Comparison of High Spectral Resolution Infrared Cloud-Top Pressure Altitude Algorithms Using S-HIS Measurements

This paper presents a comparison of cloud-top altitude retrieval methods applied to S-HIS (Scanning High Resolution Interferometer Sounder) measurements. Included in this comparison is an improvement to the traditional CO2 Slicing method. The new method, CO2 Sorting, determines optimal channel pairs to apply the CO2 Slicing. Measurements from collocated samples of the Cloud Physics Lidar (CPL) and Modis Airborne Simulator (MAS) instruments assist in the comparison. For optically thick clouds good correlation between the S-HIS and lidar cloud-top retrievals are found. For tenuous ice clouds there can be large differences between lidar (CPL) and S-HIS retrieved cloud-tops. It is found that CO2 Sorting significantly reduces the cloud height biases for the optically thin cloud (total optical depths less then 1.0). For geometrically thick but optically thin cirrus clouds large differences between the S-HIS infrared cloud top retrievals and the CPL detected cloud top where found. For these cases the cloud height retrieved by the S-HIS cloud retrievals correlated closely with the level the CPL integrated cloud optical depth was approximately 1.0.

Holz, Robert E.↗

Imaging Spectrometers Using Concave Holographic Gratings

Imaging spectroscopy combines the spatial attributes of imaging with the compositionally diagnostic attributes of spectroscopy. For spacebased remote sensing applications, mass, size, power, data rate, and application constrain the scanning approach. For the first three approaches, substantial savings in mass and size of the spectrometer can be achieved in some cases with a concave holographic grating and careful placement of an order-sorting filter. A hologram etched on the single concave surface contains the equivalent of the collimating, dispersing, and camera optics of a conventional grating spectrometer and provides substantial wavelength dependent corrections for spherical aberrations and a flat focal field. These gratings can be blazed to improve efficiency when used over a small wavelength range or left unblazed for broadband uniform efficiency when used over a wavelength range of up to 2 orders. More than 1 order can be imaged along the dispersion axis by placing an appropriately designed step order-sorting filter in front of the one- or two-dimensional detector. This filter can be shaped for additional aberration corrections. The VIRIS imaging spectrometer based on the broadband design provides simultaneous imaging of the entrance slit from lambda = 0.9 to 2.6 microns (1.5 orders) onto a 128 x 128 HgCdTe detector (at 77 K). The VIRIS spectrometer was used for lunar mapping with the UH 24.in telescope at Mauna Kea Observatory. The design is adaptable for small, low mass, space based imaging spectrometers.

Gradie, J.↗

Are Medications Involved in Vision and Intracrancial Pressure Changes Seen in Spaceflight?

The Food and Drug Association Adverse Event Reports (FDA AER) from 2009-2011 were used to create a database from millions of known and suspected medication-related adverse events among the general public. Vision changes, sometimes associated with intracranial pressure changes (VIIP), have been noted in some long duration crewmembers. Changes in vision and blood pressure (which can subsequently affect intracranial pressure) are fairly common side effects of medications. The purpose of this study was to explore the possibility of medication involvement in crew VIIP symptoms. Reports of suspected medication-related adverse events may be filed with the Food and Drug Administration (FDA) by medical professionals or consumers. Quarterly compilations of these reports are available for public download. Adverse Event Reporting System (AERS) reports from 1/1/2009- 6/30/2012 were downloaded and compiled into a searchable database for this study. Reports involving individuals under the age of 18 and older than 65 were excluded from this analysis. Case reports involving chronic diseases such as cancer, diabetes, multiple sclerosis and other serious conditions were also excluded. A scan of the medical literature for medication-related VIIP-like adverse events was used to create a list of suspect medications. These medications, as well as certain medications used frequently by ISS crew, were used to query the database. Queries for use of suspected medications were run, and the nature of the symptoms reported in those cases were tabulated. Symptoms searched in the FDA AERS were chosen to include the typical symptoms noted in crewmembers with VIIP. Vision symptoms searched were: visual acuity reduced, visual impairment, and vitreous floaters. Pressure changes included: abnormal sensation in eye, intracranial pressure increased, intraocular pressure increased, optic neuritis, optic neuropathy, and papilloedema. Limited demographic information is included with the FDA AERS; relevant data were also sorted by age and sex from each report. RESULTS Steroid-containing oral contraceptives had the highest number of reports associated with vision (n=166) and pressure symptoms (n=54). Corticosteroid-containing medications were also high; prednisone, for example, had 137 reports of vision issues and 79 of pressure issues. Pain relievers were also a medication class with vision and pressure-related adverse events reported. Common over-the-counter medications such as acetaminophen, aspirin and ibuprofen each had multiple reports for both vision and pressure symptoms. Antimicrobial medications ciprofloxacin and diflucan were also associated with a number of vision and pressure-related AERS. Unexpectedly, pseudoephedrine and promethazine were mentioned in fewer than 20 reports each over the 3.5 years of data examined. The FDA AERS represents a wealth of data, but there are several limitations to its use. The data are entered by the public or medical professionals, but are not checked for accuracy or completeness and may even be entered multiple times. The causal relationship between a particular adverse event and a particular medication is not tested. The cases represent a broad spectrum of demographics, occupations, and health histories, and thus do not model the astronaut population well. There is no information on the frequency of use of a medication for comparison purposes; it is not possible to assign a rate for any particular adverse event. Nonetheless, there are compelling trends. Use of corticosteroid-containing medications, pain relievers (even over-the-counter), and oral contraceptives were associated with higher numbers of vision- or intracranial pressure-related adverse events. In general, there were more vision problems than pressure problems reported. Certain medications that were once suspected of playing a role in the crew VIIP syndrome, namely pseudoephedrine and promethazine, were found to have extremely low numbers of VIIP-like AERS in the FDA data. However, crew use of corticosteroid-containing medications and pain relievers may warrant additional investigation

Faust, K. M.↗

Design and fabrication of engineering model fiber-optics detector

The design and fabrication of an annular ring detector consisting of optical fibers terminated with photodetectors is described. The maximum width of each concentric ring has to be small enough to permit the resolution of a Ronchi ruling transform with a dot spacing of 150 microns. A minimum of 100 concentric rings covering a circular area of 2.54 cm diameter also is necessary. A fiber-optic array consisting of approximately 89,000 fibers of 76 microns diameter was fabricated to meet the above requirements. The fibers within a circular area of 2.5 cm diameter were sorted into 168 adjacent rings concentric with the center fiber. The response characteristics of several photodetectors were measured, and the data used to compare their linearity of response and dynamic range. Also, coupling loss measurements were made for three different methods of terminating the optical fibers with a photodetector.

Mcsweeney, A.↗

Are the World's Oceans Optically Different?

Regional differences in the Sea-viewing Wide Field-of-view Sensor chlorophyll algorithm uncertainty were observed in a large global data set containing coincident in situ measurements of chlorophyll a concentration (Chla) and spectral radiometry. The uncertainty was found to be systematic when the data were sorted by ocean: Atlantic, Pacific, Southern, and Indian Oceans. Artifacts associated with different instrumentation and analytical methods had been previously ruled out. Given these oceanic biases in the chlorophyll algorithm, we hypothesized that the oceans may be optically different, and their optical differences may be intrinsically related to regional differences in phytoplankton community structure or biogeochemical processes. The oceanic biases, originally observed using radiometric measurements, were independently verified using total absorption measurements in a subset of the data. Moreover, they were explained through oceanic differences in the absorption of colored detrital matter (CDM) and phytoplankton. Both effects were considered together in explaining the ocean biases through a stepwise linear regression analysis. Significant oceanic differences in the amount of CDM and in phytoplankton cell sizes and pigmentation would give rise to optical differences, but we raise a concern for the spatial coverage of the data. We do not suggest the application of ocean-based algorithms but rather emphasize the importance of consolidating regional data sets before reaching this conclusion.

Szeto, M.↗

Shuttle communication and tracking systems signal design and interface compatibility analysis

Various options for the Dedicated Payload Communication Link (DPCL) were evaluated. Specific subjects addressed include: payload to DPCL power transfer in the proximity of the payload, DPCL antenna pointing considerations, and DPCL transceiver implementations which can be mounted on the deployed antenna boom. Additional analysis of the Space Telescope performance was conducted. The feasibility of using the Global Positioning System (GPS) for attitude determination and control for large spacecraft was examined. The objective of the Shuttle Orbiter Radar Test and Evaluation (SORTE) program was to quantify the Ku-band radar tracking accuracy using White Sands Missile Range (WSMR) radar and optical tracking equipment, with helicopter and balloon targets.

Source record↗

Jet Propulsion Laboratories in Space: The Production of Astrophysical Jets by Magnetic Accretion Disks, and a Super-Eddington Wind Model for the Early Stages of GROJ1455-40

Measurements of the properties of gravitational lenses have the power to tell us what sort of universe we live in. The brightest known radio Einstein ring/gravitational lens PKS 1830-211, whilst obscured by our galaxy at optical wavelengths, has recently provided a lensing galaxy redshift of 0.89 through the detection of a new absorption feature, most likely due to neutral hydrogen in a second redshift system at z=0.19.

PKS 1830-211↗

PKS 1830-211: A Possible Compound Gravitational Lens

Measurements of the properties of gravitational lenses have the power to tell us what sort of universe we live in. The brightest known radio Einstein ring/gravitational lens PKS 1830-211, whilst obscured by our Galaxy at optical wavelengths, has recently provided a lensing galaxy redshift of 0.89 through the detection of molecular absorption in the millimetre waveband.

new absorption feature lensing galaxy redshift sec↗

Proposed Definitions of Some Technical Terms Frequently Used in Microwave Radiometry for Remote Sensing

The use of microwave radiometry for remote sensing is a relatively young field. As a result, there are no standard definitions of many frequently used technical terms; a lot of which are conventional usages carried-over from optical remote sensing, and a lot more are shared with electrical or microwave engineering. Sometimes the divergent notions and assumptions originating from a different field may cause ambiguity or confusions. It is proposed that we establish a list of frequently used terms, together with their 'standard' definitions and hope that they will gradually gain general acceptance by the remote sensing community. It would be even more useful if the IEEE community can set up a standard committee of sort to develop and maintain the standards. To minimize the effort, the existing terms should be kept or reinterpreted as much as possible. For example, the term 'Instantaneous Field of View' (IFOV), originally coming from the optical remote sensing field, is now appearing in microwave remote sensing literature frequently. The IFOV refers to the 'beam width' or the 'diameter' of the beam's geometrical projection on earth surface. Since the definition of 'beam width' is different for an optical system versus a microwave antenna, the use of IFOV in microwave radiometry needed to be clarified. Also, the meaning of the IFOV will be different depending upon whether the beam is scanning or not, and how the scanning takes place, e.g. 'continuous scanning' vs 'stare-and-step scan.' From this one term alone, it is clear that more subtle meanings must be spell out in detail and a 'standard' definition would help in understanding and comparing systems and data in the literature. A selected list of terms with their suggested definitions will be discussed in this presentation.

Shiue, James C.↗

Investigation of Overlap Correction Techniques for Application in the Micro-Pulse Lidar Network (MPLNET)

The Micro-Pulse Lidar NETwork (MPLNET) is comprised of micro-pulse lidars (MPL) stationed around the globe to provide measurements of aerosol and cloud vertical distribution on a continuous basis. MPLNET sites are co-located with sunphotometers in the AErosol Robotic NETwork (AERONET) to provide joint measurements of aerosol optical depth, size, and other inherent optical properties. The IPCC 2001 report discusses . the importance of obtaining routine measurements of aerosol vertical structure, especially for absorbing aerosols. MPLNET provides exactly this sort of measurement, including calculation of aerosol extinction profiles, in a near real-time basis for all sites in the network. In order to obtain aerosol profiles, near range signal returns (0-6 km) must be accurately measured by the MPL. This measurement is complicated by the instrument s overlap range: Le., the minimum distance at which returning signals are completely in the instrument s field-of-view (FOV). Typical MPL overlap distances are large, between 5 - 6 km, due to the narrow FOV of the MPL receiver. A function describing the MPL overlap must be determined and used to correct signals in this range. Currently, overlap functions for MPLNET are determined using horizontal MPL measurements along a path with 10-1 5 km clear line-of-sight and a homogenous atmosphere. These conditions limit the location and ease in which successful overlaps can be obtained. Furthermore, the current MPLNET process of correcting for overlap increases the uncertainty and bias error for the near range signals and the resulting aerosol extinction profiles. To address these issues, an alternative overlap correction method using a small-diameter, wide FOV receiver is being considered for potential use in MPLNET. The wide FOV receiver has a much shorter overlap distance and will be used to calculate the overlap function of the MPL receiver. This approach has a significant benefit in that overlap corrections could be obtained without the need for horizontal measurements. A review of both overlap methods is presented, including a discussion of the impact on reducing the uncertainty and bias error in MPLNET aerosol profiles.

Berkoff, Timothy A.↗

General Astrophysics with TPF: Not Just Dark Energy

Besides searching for Earth-LIke Planets, TPF can study Jupiters, Neptunes, and all sorts of exotic planets. It can image debris-disks, YSO disks, AGN disks, maybe even AGB disks. And you are probably aware that a large optical space telescope like TPF-C or TPF-O can be a fantastic tool for studying the equation of state of the Dark Energy. I will review some of the future science of TPF-C, TPF-I and TPF-O, focusing on the applications of TPF to the study of objects in our Galaxy: especially circumstellar disks and planets other than exo-Earths.

Kuchner, Marc↗

An optical technique for examining aircraft shock wave structures in flight

The detailed properties of sonic booms have to be better understood before commercial, next generation, supersonic and hypersonic aircraft can be properly developed. Experimental tests and measurements are needed to help sort the physical details of the flows at realistic test conditions. Some of these tests can be made in wind tunnels, but the need for full flight conditions simulation, the problem of tunnel wall interference, and the short distance the shocks can be examined from the aircraft, limit the usefulness of wind tunnel tests. Previous measurement techniques for examining the flow field of aircraft in flight have included pressure measurements on the aircraft, ground based pressure measurements, and flow field measurements made with chase aircraft. Obtaining data with chase planes is a slow and difficult process, and is limited in how close it can be obtained to the test aircraft. A need clearly existed for a better technique to examine the shock structure from the plane to large distances from the plane. A new technique has been recently developed to obtain schlieren photographs of aircraft in flight (SAF). Preliminary results have been obtained, and the technique holds promise as a tool to study the shape and approximate strength of the shock wave structure around the test aircraft, and examine shock wave details all the way from the aircraft to near the ground. The current paper describes this approach, and gives some preliminary test results.

Weinstein, Leonard M.↗