Low-Cost Scroll Organic Rankine Cycle (Final Report)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.
An organic Rankine-cycle (ORC) power module was developed for use in a multimodule solar power plant to be built and operated in a small community. Many successful components and subsystems, including the reciever, power conversion subsystem, energy transport subsystem, and control subsystem, were tested. Tests were performed on a complete power module using a test bed concentrator in place of the proposed concentrator. All major single-module program functional objectives were met and the multimodule operation presented no apparent problems. The hermetically sealed, self-contained, ORC power conversion unit subsequently successfully completed a 300-hour endurance run with no evidence of wear or operating problems.
The organic Rankine-cycle (ORC) power conversion assembly was tested. Qualification testing of the electrical transport subsystem was also completed. Test objectives were to verify compatibility of all system elements with emphasis on control of the power conversion assembly, to evaluate the performance and efficiency of the components, and to validate operating procedures. After 34 hours of power generation under a wide range of conditions, the net module efficiency exceeded 18% after accounting for all parasitic losses.
A system analysis and preliminary design were conducted for an organic Rankine-cycle system to bottom the high-temperature waste heat of an adiabatic diesel engine. The bottoming cycle is a compact package that includes a cylindrical air cooled condenser regenerator module and other unique features. The bottoming cycle output is 56 horsepower at design point conditions when compounding the reference 317 horsepower turbocharged diesel engine with a resulting brake specific fuel consumption of 0.268 lb/hp-hr for the compound engine. The bottoming cycle when applied to a turbocompound diesel delivers a compound engine brake specific fuel consumption of 0.258 lb/hp-hr. This system for heavy duty transport applications uses the organic working fluid RC-1, which is a mixture of 60 mole percent pentafluorobenzene and 40 mole percent hexafluorobenzene. The thermal stability of the RC-1 organic fluid was tested in a dynamic fluid test loop that simulates the operation of Rankine-cycle. More than 1600 hours of operation were completed with results showing that the RC-1 is thermally stable up to 900 F.
Multigeneration systems represent an appealing concept, due to their multiple benefits compared to standalone systems, which has motivated researchers to develop different types of multigeneration systems for several applications. Considering their significance, in this study, a novel multigeneration is proposed that uses the waste heat of a thermodynamically efficient triple power cycle with a 100 MWe capacity. The proposed system, which can generate power, freshwater, cooling, and domestic hot water concurrently, is evaluated using detailed thermodynamic and economic analyses. The triple cycle includes a simple Brayton cycle coupled with a supercritical carbon dioxide recompression cycle and a high-temperature organic Rankine cycle. The waste energy of the recompression and organic Rankine cycles is recovered by a half effect absorption chiller, a multi-effect distillation unit, and two heat exchangers. The results show that for an optimized triple cycle, up to 1,804 kW cooling and 8,472 m 3 /day of hot water can be generated from the hot supercritical carbon dioxide stream with a levelized cost of cooling and hot water of 0.0362/ton-hr and $0.6823/MWth, respectively. The integration of a multi-effect distillation unit with 7 effects can generate 4,167 m 3 /day freshwater with a levelized cost of water of $1.142/m 3 . Finally, the proposed multigeneration system offers a very promising application and a number of benefits such as a generating multiple useful products with no adverse effect on the thermodynamic efficiency of the triple power cycle.
The bearing development program is summarized for a 25-kWe power conversion subsystem (PCS) consisting of an organic Rankine-cycle engine, and permanent magnetic alternator (PMA) and rectifier to be used in a 100-kWe point-focusing distributed receiver solar power plant. The engine and alternator were hermetically sealed and used toluene as the working fluid. The turbine, alternator, and feed pump (TAP) were mounted on a single shaft operating at speeds up to 60,000 rev/min. Net thermal-to-electric efficiencies in the range of 21 to 23% were demonstrated at the maximum working fluid temperature of 400 C (750 F). A chronological summary of the bearing development program is presented. The primary causes of bearing wear problems were traced to a combination of rotordynamic instability and electrodynamic discharge across the bearing surfaces caused by recirculating currents from the PMA. These problems were resolved by implementing an externally supplied, flooded-bearing lubrication system and by electrically insulating all bearings from the TAP housing. This program resulted in the successful development of a stable, high-speed, toluene-lubricated five-pad tilting-pad journal bearing and Rayleigh step thrust bearing system capable of operating at all inclinations between horizontal and vertical.
The results of design integration studies of uranium-zirconium hydride (UZr-Hx) reactor power systems for the NASA space base study program are presented. The power conversion systems investigated include the Brayton cycle, the organic Rankine cycle, the SNAP-8 mercury Rankine cycle, and thermoelectric (PbTe). The proposed space base has a 10-year life and requires 100 kWe of power. Two 50-kWe power systems with a nominal replacement life of 5 years are utilized. Parametric design data such as life, weight, radiator area, reactor outlet-temperature, reactor thermal power, and power conversion system efficiency are presented and used for the design and integration of the system with the space base.
An organic Rankine cycle engine is used as part of a solar thermal power conversion assembly (PCA). The PCA, including a direct-heated cavity receiver and a shaft-mounted alternator, is mounted at the focal point of a parabolic dish concentrator. The engine controls are required to maintain approximately constant values of turbine inlet temperature and shaft speed, despite variation in the concentrated solar power input to the receiver. The controls design approach, system models, and initial stability and performance analysis results are presented herein.
A study was conducted to define the best radiator for heat rejection of the Space Station Solar Dynamic Power System. Included in the study were radiators for both the Organic Rankine Cycle and Closed Brayton Cycle heat engines. A number of potential approaches were considered for the Organic Rankine Cycle and a constructable radiator was chosen. Detailed optimizations of this concept were conducted resulting in a baseline for inclusion into the ORC Preliminary Design. A number of approaches were also considered for the CBC radiator. For this application a deployed pumped liquid radiator was selected which was also refined resulting in a baseline for the CBC preliminary design. This paper reports the results and methodology of these studies and describes the preliminary designs of the Space Station Solar Dynamic Power System radiators for both of the candidate heat engine cycles.
Low temperature geothermal resources, including those associated with oil and gas production, are an underutilized source of low carbon energy. The present work investigates coupling of low-temperature geothermal resources with concentrating solar and/or natural gas energy sources to increase the number of locations at which power generation from low temperature geothermal resources would be technically and economically viable. Stand-alone and hybrid geothermal power cycles are simulated using SimTech IPSEpro process modeling software. Design point strategies for a hybrid power cycle that may operate with either a single heat source or two simultaneous heat input sources are considered. Additionally, off-design power plant operation is investigated to consider the impacts of the heat source availability and ambient temperature variations. The off-design analysis utilizes a modeling tool that predicts power plant performance at each time step as a function of topping cycle heat input (from gas or solar), bottoming cycle heat input (from geothermal), and ambient temperature. Addition of a steam topping cycle to an organic Rankine cycle geothermal power plant provides opportunities to increase the efficiency and power output relative to a stand-alone geothermal power plant. Additionally, use of the waste heat from gas turbine power generation in a geothermal bottoming cycle provides opportunities to increase the amount of power generation associated with each unit of carbon dioxide emitted. This paper will describe the hybrid plant configuration evaluated, discuss the predicted power cycle performance, and compare with stand-alone natural gas and geothermal power generation cases. The power cycle investigated is expected to be applicable for use with conventional hydrothermal resources as well as with geologic thermal energy storage applications and/or enhanced geothermal systems. The steam topping cycle could use a concentrated solar heat source for fully renewable hybrid plant configuration. A plant initially constructed with a natural gas topping cycle heat source could be converted to a solar heat source part way though the power cycle operational life to achieve life cycle carbon emission reductions.
In the past, NASA has employed solar photovoltaic devices for long-duration missions. Thus, the Skylab system has operated with a silicon photovoltaic array and a nickel-cadmium electrochemical system energy storage system. Difficulties regarding the employment of such a system for the larger power requirements of the Space Station are related to a low orbit system efficiency and the large weight of the battery. For this reason the employment of a solar dynamic power system (SDPS) has been considered. The primary components of an SDPS include a concentrating mirror, a heat receiver, a thermal energy storage (TES) system, a thermodynamic heat engine, an alternator, and a heat rejection system. The heat-engine types under consideration are a Brayton cycle engine, an organic Rankine cycle engine, and a free-piston/linear-alternator Stirling cycle engine. Attention is given to a system description, TES integration concepts, and a TES technology assessment.
The solar powered system located near Willard, New Mexico, generates mechanical or electrical power at a capacity of 19 kW (25 HP). The solar collection system incorporates east/west tracking parabolic trough collectors with a total aperture area of 1275 sq m (13,720 sq ft). The hot oil type thermal energy storage is sufficient for approximately 20 hours of power system operation. The system utilizes a reaction type turbine in conjunction with an organic Rankine cycle engine. Total collector field efficiency reaches a maximum of 20 percent near the winter solstice and about 50 percent during the summer. During the month of July, 1979, the system pumped 60 percent of the 35,300 cu m (28.6 acre-feet) of water delivered. Operating efficiencies for the turbine component, organic Rankine cycle engine and the complete power system are respectively 65 to 75 percent, 12 to 15 percent and 5 to 6 percent. Significant maintenance time was expended on both the collector and power systems throughout the operational period.
The state-of-the-art of commercially available organic Rankine cycle (ORC) hardware from a literature search and industry survey is assessed. Engineering criteria for applying ORC technology are established, and a set of nomograms to enable the rapid sizing of the equipment is presented. A comparison of an ORC system with conventional heat recovery techniques can be made with a nomogram developed for a recuperative heat exchanger. A graphical technique for evaluating the economic aspects of an ORC system and conventional heat recovery method is discussed: also included is a description of anticipated future trends in organic Rankine cycle R&D.
In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.
Geothermal electricity co-production is a viable option for oil reservoirs producing large water cuts with elevated wellhead-observed temperatures. Repurposing existing oil wells significantly reduces initial investment costs historically associated with geothermal resource utilization. The National Renewable Energy Laboratory (NREL), partnering with Gradient Geothermal, Inc. (formerly known as Transitional Energy) and Grant Canyon Oil and Gas, has been tasked to evaluate the feasibility of geothermal electricity co-production at the Blackburn Oil Field with Organic Rankine Cycle (ORC) generators. The Devonian steady-state reservoir has historically been producing high water cuts of 240 degrees F (115.6 degrees C) observed at the wellhead without documented pressure drawdown or thermal breakthrough. An estimated initial reservoir temperature of approx. 260degreesF (126.7 degrees C) has been observed in the field and history-matched in a wellbore production analysis and reservoir simulation. Our objective was to develop a conceptual geological model of the subsurface, simulate a natural-state reservoir, model production scenarios, and complete a technical feasibility analysis to accomplish this task. Through extensive modeling and the use of available proprietary and public data, it was possible simulate three scenarios that indicated minimal thermal decline over the duration of a simulated ten-year production and re-injection scheme.
Geothermal electricity co-production is a viable option for oil reservoirs producing large water cuts with elevated wellhead temperatures. Repurposing existing oil wells significantly reduces initial investment costs historically associated with geothermal resource utilization. The National Renewable Energy Laboratory (NREL), partnering with Gradient Geothermal, Inc. (formerly known as Transitional Energy) and Grant Canyon Oil and Gas, has been tasked to evaluate the feasibility of geothermal electricity co-production at the Blackburn Oil Field with Organic Rankine Cycle (ORC) generators. The Devonian steady-state reservoir has historically been producing high water cuts of 240 degrees F (115.6 degrees C) observed at the wellhead without documented pressure drawdown or thermal breakthrough. An estimated initial reservoir temperature of approx. 260 degrees F (126.7 degrees C) has been observed in the field and history-matched in a wellbore production analysis and reservoir simulation. Our objective was to develop a conceptual geological model of the subsurface, simulate a natural-state reservoir, model production scenarios, and complete a technical feasibility analysis to accomplish this task. Through extensive modeling and the use of available proprietary and public data, it was possible simulate three scenarios that indicated minimal thermal decline over the duration of a simulated ten-year production and re-injection scheme.
The U.S. Department of Energy estimates that an annual average of 25 billion barrels of hot water are produced from oil and gas wells within the United States. The thermal energy available in the co-produced water stream is usually discarded, as the produced waters are considered an inconvenience by the operators and are disposed of using injection wells. However, utilizing organic Rankine cycle (ORC) generators, a vast amount of thermal energy can be captured and converted into electricity (albeit at relatively low efficiency due to the low temperatures). The National Renewable Energy Laboratory (NREL), in collaboration with Transitional Energy and Grant Canyon Oil & Gas, evaluated the feasibility of geothermal co-production of electricity by utilizing existing oil wells in Blackburn oil field in Nevada. The once prolific Blackburn oil field is located in Pine Valley, approximately 45 miles east-southeast of Elko, Nevada. Currently, the wells targeting the highly fractured Devonian Nevada dolomite reservoir are operating at a water cut ratio of more than 99%, with individual fluid (oil and water) production rates reaching 7.4 L/s (4,021 BBL/day). Analysis of publicly available data showed that the combination of the suitable wells' maximum historical production rates reached 22.90 L/s. The production from these wells occurs naturally and the wells are choked (and even shut down) by the operator to mitigate excessive water production, indicating a strong reservoir recharge and future opportunity to increase the water production for geothermal electricity generation. The main goal of this study was to evaluate the productivity of the existing wells, the performance of the reservoir, the surface network, and the operational constraints in order to achieve 1 MWe of electricity production from the field's water production. Utilizing the GEOPHIRES tool, we have determined that a twofold to threefold increase in the total fluid production, compared to the historical production under artificial restraint (choke), is required to reach a 1-MWe net target output for a low-temperature ORC system with air-cooled condensers. Lower flow rates would be required when utilizing water-based condensers instead of air-cooled condensers. However, that would require a constant supply of cold water, which may be challenging given the arid environment of the project site.