Search NASA⌕ Search

SEARCH · Search NASA

Results for “Overall Cooling Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

Counter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. Here, the hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.

17 WIND ENERGY↗

Experimental and Computational Investigation of Integrated Internal and Film Cooling Designs Incorporating a Thermal Barrier Coating

Abstract Few studies in the open literature have studied the effect of thermal barrier coatings (TBC) when used in combination with shaped hole film cooling and enhanced internal cooling techniques. The current study presents Reynolds-averaged Navier–Stokes (RANS) conjugate heat transfer simulations that identify trends in cooling design performance as well as experimental measurements of overall effectiveness using a flat-plate matched-Biot number model with a simulated TBC layer of 0.42D thickness, where D is the film cooling hole diameter. Coolant is fed to the film cooling holes in a co-flow configuration, and the results of both the smooth and rib-turbulated channels are compared. At a constant coolant flow rate, enhanced internal cooling was found to provide a 44% increase in spatially-averaged overall effectiveness, $\bar{\bar{\phi}}$, without a TBC. The results show that the addition of a TBC can raise $\bar{\bar{\phi}}$ on a film-cooled component surface by 47%. The optimum velocity ratio was found to decrease with the addition of enhanced cooling techniques and a TBC as the film provided minimal benefit at the expense of reduced internal cooling. While the computational results closely identified trends in overall system performance without a TBC, the model over-predicted effectiveness on the metal–TBC interface. The results of this study will inform turbine component design as material science advances increase the reliability of the TBC.

Engineering↗

Printability and Overall Cooling Performance of Additively Manufactured Holes With Inlet and Exit Rounding

Abstract To improve cooling effectiveness of gas turbine hardware, various film cooling hole shapes have previously been researched. Unique design modifications have recently been made possible through the design freedom allotted by additive manufacturing (AM). As one example, creating a rounded inlet for a film-cooling hole can mitigate separation at the inlet. This study explores various geometric features by exploiting the uses of additive manufacturing for shaped film cooling holes at engine scale. Both printability and cooling performance were evaluated. Resulting from this study, additively manufactured holes with hole inlet and exit rounding were printed with some variations from the design intent (DI). The largest deviations from the design intent occurred from dross roughness features located on the leeward side of the hole inlet. The measured overall effectiveness indicated that an as-built inlet fillet decreased in-hole convection as well as decreased jet mixing compared to the as-built sharp inlet. Including an exit fillet, which prevented an overbuilt diffuser exit, was also found to decrease jet mixing. A particular insight gained from this study is the importance of the convective cooling within the hole to the overall cooling performance. In-hole roughness, which is a result of additive manufacturing, increased convective cooling within the holes but also increased jet mixing as the coolant exited the hole. The increased jet mixing caused low overall effectiveness downstream of injection.

Engineering↗

Plasma-induced collective effects in muon ionization cooling

Muon ionization cooling is a critical process that determines the achievable beam brightness and overall performance of a muon collider. In this study, we investigate collective effects induced by high-intensity muon beams inside the absorber, effects that have not been included in previous ionization cooling simulations. We show that beam-induced plasma can neutralize the beam space-charge field, while the self-generated azimuthal magnetic field can introduce additional beam focusing through a z-pinch-like mechanism. We also demonstrate that sufficiently high plasma densities may modify the stopping-power rate. The implications of these plasma-induced phenomena for ionization cooling performance are discussed.

Yonehara, Katsuya [Fermilab] (ORCID:00000002544041↗

Modeling Molten Salt Spreading and Heat Transfer using MELTSPREAD – An Uncertainty Analysis

This report summarizes spreading and heat transfer results for molten salt pouring onto a flat stainless steel substrate that were calculated using MELTSPREAD to gain insight into bulk salt behavior during a molten salt spill accident. MELTSPREAD was developed at Argonne to model the one-dimensional flow and freezing behavior of molten corium and is being applied to model molten salts for the first time as part of this work. An uncertainty analysis of thermophysical properties and spill conditions was performed using MELTSPREAD to determine which properties and conditions have the greatest impact on model outcome. The model was run with and without the inclusion of decay heat. Eutectic FLiNaK was used as the salt composition because it is well-characterized and appropriate for model development. Small salt volumes were used for the initial model runs described in this report so that the model results can be compared to the results from ongoing experiments on molten salt spreading and heat transfer currently being conducted at Argonne at a benchtop scale. The spreading of a small volume of FLiNaK (50 mL) was found to be limited by the balance between the molten salt surface tension and gravity and not by freezing for the pour conditions and assumed mechanisms of heat transfer in the model. Heat transfer from the salt was highly inefficient to due to its low thermal conductivity, high heat capacity, and high heat of fusion and varying these properties had no effect on the spreading behavior. Changing the viscosity and density of the salt slightly affected the spreading behavior. Setting the salt surface tension to approximately zero to simulate the salt wetting the substrate had the greatest effect on the spreading behavior and this increased both the spreading velocity and overall spreading area. Including decay heat in the model had a significant effect on the long-term cooling behavior of the salt but had no effect on the overall spreading behavior. Future effort should involve modeling a larger volume of molten salt to represent a reactor case spill scenario because the spreading behavior of large volumes of salt may differ from the small volumes that were the focus of this document.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revolutionizing Turbine Cooling with Micro-Architectures Enabled by Direct Metal Laser Sintering

The objective of this research effort was to explore innovative cooling architectures enabled by additive manufacturing techniques for improved turbine cooling performance. The ability to create complex internal geometries was leveraged to better distribute coolant as well as to integrate inherently unstable flow devices to enhance internal and external heat transfer. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. This final report documents progress during the total 4.25 year effort that was extended (at no additional cost) from the original 3-year cooperative agreement. Prior to starting the project, significant effort was invested in investigating innovative cooling designs from the open literature. When the project started, we quickly down-selected to 4 configurations: impingement jet fluidic oscillators (for internal leading edge cooling), reverse film cooling (for pressure surface), sweeping film cooling jets (for suction surface), and trailing edge slot cooling with microchannels. During the 2nd year, the reverse film cooling design was shown to be sub-optimal and work on that topic was halted. The three remaining technologies were integrated into a large scale nozzle guide vane and installed into a low-speed linear cascade facility for further interrogation. Initial results showed the sweeping film cooling jets (on the suction surface) to be the most promising technology compared to a baseline diffusion shaped film hole (777 design). The benefit was particularly evident at high blowing ratios (>1.5) when the 777 coolant film separated from the downstream surface. Benefits were also evident at elevated freestream turbulence levels. The leading edge cooling with unsteady jets was less effective in terms of peak or average cooling – however it was superior to round hole impingement cooling in terms of spatial uniformity. Finally, the trailing edge cooling design with micro-channels was scrapped in favor of a pinned arrangement with centerbody. During the 3rd year, the same three technologies were integrated into a transonic linear cascade for an assessment of compressibility effects. Again, the sweeping film cooling jets proved superior at high blowing ratios while the unsteady leading edge impingement and trailing edge pin-fins with centerbody designs yielded mixed results. Finally, during the 4th and final year, these 3 technologies were integrated into a direct metal laser sintered (DMLS) nozzle guide vane for testing in a high temperature, transonic annular vane cascade. The facility matches the flow temperature, Mach number, and coolant pressure ratios of an actual gas turbine. Before doing this, an additional series of tests were completed to validate a redesigned trailing edge cooling architecture. This final design included a centerbody with triangular pins between the centerbody and the vane external skin. The majority of these triangular pins are fabricated with a 30% gap to the centerbody – reducing their pressure drop considerably while still providing excellent heat transfer augmentation. This additional test campaign required an additional 3-month extension request to complete testing in the high temperature NGV test facility (Turbine Reacting Flow Rig – TuRFR). Testing of the DMLS vane in TuRFR pitted the 3 innovative cooling technologies against more traditional technologies (shaped 777 film hole, round impingement jet, and full pin arrangement in the trailing edge. The sweeping film cooling jets (on the suction surface) showed approximately 15% improvement in overall effectiveness compared to the 777 film hole while the trailing edge showed up to 20% improvement. The leading edge impingement was disappointing with a substantially lower effectiveness than traditional direct impingement. In summary, the study was successful in demonstrating that DMLS-enabled cooling technologies can yield significant gains in cooling performance.

03 NATURAL GAS↗

Real-time optimization of multi-cell industrial evaporative cooling towers using machine learning and particle swarm optimization

Existing electrical generating stations must operate with greater flexibility due to increasing renewable energy penetration on the electrical grid, and many coal-fired power stations have transitioned away from baseload operation to load-following operation to aid in grid stability. In cases where multiple independently controlled cooling tower cells are used in parallel for the cooling purposes of such stations, there is an opportunity to increase plant efficiency through data-driven optimization across their full load ranges. This work presents a novel application of real-time optimization using machine learning and particle swarm optimization on a multi-cell induced-draft cooling tower servicing a coal-fired power station under variable load. This is the first work to demonstrate simultaneous optimization of a multi-cell cooling tower, in addition to using machine learning for closed-loop control on a cooling tower. A novel control configuration is presented that ensures original control logic is not adversely affected and that the overall plant process is not disrupted using only existing hardware and operational data. To verify this methodology, the 12 independent cooling tower cells are simulated in parallel using historic operating data to demonstrate the effectiveness of real-time optimization compared to current practice. An artificial neural network is trained to predict overall cooling tower power consumption using only operational data and ambient conditions with an R2 value of greater than 0.96. The real-time optimization using particle swarm yields 6.7% annual energy usage savings compared to current practices, although the extent of the real-time savings varies greatly with both plant load and environmental conditions. This is particularly significant for a variable load situation because frequent ramping typically results in reduced overall efficiency. Furthermore, this proposed AI-based solution presents an opportunity to improve the overall heat rate of a load-following coal-fired power plant without the need to perform extensive first-principles modeling or add additional hardware to the cooling tower, resulting in more resources conserved and less overall emissions per unit of electricity generated.

42 ENGINEERING↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daytime cooling efficiencies of urban trees derived from land surface temperature are much higher than those for air temperature

Accurately capturing the impact of urban trees on temperature can help optimize urban heat mitigation strategies. Recently, there has been widespread use of remotely sensed land surface temperature (T s ) to quantify the cooling efficiency (CE) of urban trees. However, remotely sensed T s reflects emitted radiation from the surface of an object seen from the point of view of the thermal sensor, which is not a good proxy for the air temperature (T a ) perceived by humans. The extent to which the CEs derived from T s reflect the true experiences of urban residents is debatable. Therefore, this study systematically compared the T s -based CE (CE T s ) with the T a -based CE (CE T a ) in 392 European urban clusters. CE T s and CE T a were defined as the reductions in T s and T a , respectively, for every 1% increase in fractional tree cover (FTC). The results show that the increase in FTC has a substantial impact on reducing T s and T a in most cities during daytime. However, at night, the response of T s and T a to increased FTC appears to be much weaker and ambiguous. On average, for European cities, daytime CE T s reaches 0.075 °C % -1 , which is significantly higher (by an order of magnitude) than the corresponding CE T a of 0.006 °C % -1 . In contrast, the average nighttime CE T s and CE T a for European cities are similar, both approximating zero. Overall, urban trees can lower daytime temperatures, but the magnitude of their cooling effect is notably amplified when using remotely sensed T s estimates compared to in situ T a measurements, which is important to consider for accurately constraining public health benefits. Our findings provide critical insights into the realistic efficiencies of alleviating urban heat through tree planting.

54 ENVIRONMENTAL SCIENCES↗

Climate cooling benefits of cellulosic bioenergy crops from elevated albedo

Abstract Changes in land surface albedo can alter ecosystem energy balance and potentially influence climate. We examined the albedo of six bioenergy cropping systems in southwest Michigan USA: monocultures of energy sorghum ( Sorghum bicolor ), switchgrass ( Panicum virgatum L.), and giant miscanthus ( Miscanthus × giganteus) , and polycultures of native grasses, early successional vegetation, and restored prairie. Direct field measurements of surface albedo ( α s ) from May 2018 through December 2020 at half‐hourly intervals in each system quantified the magnitudes and seasonal differences in albedo (∆ α ) and albedo‐induced radiative forcing (RF ∆ α ). We used a nearby forest as a historical native cover type to estimate reference albedo and RF ∆ α change upon original land use conversion, and a continuous no‐till maize ( Zea mays L .) system as a contemporary reference to estimate change upon conversion from annual row crops. Annually, α s differed significantly ( p < 0.05) among crops in the order: early successional (0.288 ± 0.012SE) >> miscanthus (0.271 ± 0.009) ≈ energy sorghum (0.270 ± 0.010) ≥ switchgrass (0.265 ± 0.009) ≈ restored prairie (0.264 ± 0.012) > native grasses (0.259 ± 0.010) > maize (0.247 ± 0.010). Reference forest had the lowest annual α s (0.134 ± 0.003). Albedo differences among crops during the growing season were also statistically significant, with growing season α s in perennial crops and energy sorghum on average ~20% higher (0.206 ± 0.003) than in no‐till maize (0.184 ± 0.002). Average non‐growing season (NGS) α s (0.370 ± 0.020) was much higher than growing season α s (0.203 ± 0.003) but these NGS differences were not significant. Overall, the original conversion of reference forest and maize landscapes to perennials provided a cooling effect on the local climate (RF αMAIZE : −3.83 ± 1.00 W m −2 ; RF αFOREST : −16.75 ± 3.01 W m −2 ). Significant differences among cropping systems suggest an additional management intervention for maximizing the positive climate benefit of bioenergy crops, with cellulosic crops on average ~9.1% more reflective than no‐till maize, which itself was about twice as reflective as the reference forest.

Lei, Cheyenne↗

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Effective properties of semitransparent radiative cooling materials with spectrally variable properties

Radiative cooling is a promising solid-state, non-vapor-compression technology for passive refrigeration and air conditioning. Although this phenomenon occurs naturally, achieving a significant amount of cooling to make it a technically and economically viable technology requires highly engineered, spectrally selective radiative surfaces. These characteristics make radiative cooling difficult to estimate, particularly when it is integrated with other systems such as photovoltaic panels or building envelopes. The complexity further increases when the substrate also participates in the radiative cooling (along with the radiative coating). Energy estimation is becoming increasingly critical because of the recent focus on the semitransparent radiative coatings that transmit a variety of colors to enhance the aesthetic appeal of the system. In this work, we propose an iterative method to calculate the effective radiative properties, which provides the same net radiative cooling that would be observed using the spectral properties at both the coating and substrate surfaces. Compared to traditional methods that rely on either computationally expensive full spectral analysis or methods for averaging each radiative surface parameter locally, our proposed method focuses on calculating effective properties that provide the same the net cooling effect as a full spectral analysis by accounting the emissivity, absorptivity, and transmissivity collectively, thereby providing an overall estimation error of less than 0.2%. We believe that this study will be beneficial to the engineering communities that employ complex simulation codes and require lumped solar and thermal radiation related parameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

Environmental Co‐Benefits of Maintaining Native Vegetation With Solar Photovoltaic Infrastructure

Abstract Co‐locating solar photovoltaics with vegetation could provide a sustainable solution to meeting growing food and energy demands. However, studies quantifying multiple co‐benefits resulting from maintaining vegetation at utility‐scale solar power plants are limited. We monitored the microclimate, soil moisture, panel temperature, electricity generation and soil properties at a utility‐scale solar facility in a continental climate with different site management practices. The compounding effect of photovoltaic arrays and vegetation may homogenize soil moisture distribution and provide greater soil temperature buffer against extreme temperatures. The vegetated solar areas had significantly higher soil moisture, carbon, and other nutrients compared to bare solar areas. Agrivoltaics in agricultural areas with carbon debt can be an effective climate mitigation strategy along with revitalizing agricultural soils, generating income streams from fallow land, and providing pollinator habitats. However, the benefits of vegetation cooling effects on electricity generation are rather site‐specific and depend on the background climate and soil properties. Overall, our findings provide foundational data for site preservation along with targeting site‐specific co‐benefits, and for developing climate resilient and resource conserving agrivoltaic systems.

14 SOLAR ENERGY↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Management for a Novel Non-Heavy Rare-Earth Interior Permanent Magnet Machine

The work presents a thermal management solution for a novel non-heavy rare-earth permanent magnet machine being developed at Oak Ridge National Laboratory. The motor has been designed to minimize losses while maximizing performance for a range of speeds and power ratings. The novel motor design reduces rare-earth magnet usage, thereby avoiding supply chain issues. The motor component heat losses are established for operating windows and desired performance. These heat losses, along with windage losses, are being used to develop cooling solutions for different components of this machine. A novel thermal management solution for stators and rotors has been developed, and progress is presented in this paper. The stator cooling is achieved with the help of water-ethylene glycol flowing over the finned aluminum stator jacket, and rotor cooling with automatic transmission fluid passing through novel channels designed in the rotor laminations. The attempt is to establish effective cooling of the stator winding, laminations, and rotor magnets. A 3D conjugate heat transfer model has been developed for overall thermal analysis to establish a down- selected thermal management solution for the machine. The model, in addition to estimated component heat losses, includes windage losses and its impact on rotor and stator cooling. Overall, the work presents a workable thermal solution for the interior permanent magnet machine with potential for further improvements. Future work will involve establishing end winding and refinement of other end parts of the machine with the aim of establishing a robust thermal management solution. The work will also focus on different shapes (e.g., round, non-round, presence of wedges) of rotor-stator gaps and investigate windage losses and their impact on thermal management for higher rotational speeds for the machine.

30 DIRECT ENERGY CONVERSION↗