Search NASA⌕ Search

SEARCH · Search NASA

Results for “Oxygen bubbles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Oxidation of SiC/BN/SiC Composites in Reduced Oxygen Partial Pressures

SiC fiber-reinforced SiC composites with a BN interphase are proposed for use as leading edge structures of hypersonic vehicles. The durability of these materials under hypersonic flight conditions is therefore of interest. Thermogravimetric analysis was used to characterize the oxidation kinetics of both the constituent fibers and composite coupons at four temperatures: 816, 1149, 1343, and 1538 C (1500, 2100, 2450, and 2800 F) and in oxygen partial pressures between 5% and 0.1% (balance argon) at 1 atm total pressure. One edge of the coupons was ground off so the effects of oxygen ingress into the composite could be monitored by post-test SEM and EDS. Additional characterization of the oxidation products was conducted by XPS and TOF-SIMS. Under most conditions, the BN oxidized rapidly, leading to the formation of borosilicate glass. Rapid initial oxidation followed by volatilization of boria lead to protective oxide formation and further oxidation was slow. At 1538C in 5% oxygen, both the fibers and coupons exhibited borosilicate glass formation and bubbling. At 1538C in 0.1% oxygen, active oxidation of both the fibers and the composites was observed leading to rapid SiC degradation. BN oxidation at 1538C in 0.1% oxygen was not significant.

Opila, Elizabeth J.↗

Electrolysis Bubbles Make Waterflow Visible

Technique for visualization of three-dimensional flow uses tiny tracer bubbles of hydrogen and oxygen made by electrolysis of water. Strobe-light photography used to capture flow patterns, yielding permanent record that is measured to obtain velocities of particles. Used to measure simulated mixing turbulence in proposed gas-turbine combustor and also used in other water-table flow tests.

Schultz, Donald F.↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

Venous gas embolism - Time course of residual pulmonary intravascular bubbles

A study was carried out to determine the time course of residual pulmonary intravascular bubbles after embolization with known amounts of venous air, using an N2O challenge technique. Attention was also given to the length of time that the venous gas emboli remained as discrete bubbles in the lungs with 100 percent oxygen ventilation. The data indicate that venous gas emboli can remain in the pulmonary vasculature as discrete bubbles for periods lasting up to 43 + or - 10.8 min in dogs ventilated with oxygen and nitrogen. With 100 percent oxygen ventilation, these values are reduced significantly to 19 + or - 2.5 min.

Butler, B. D.↗

GASES IN TEKTITE BUBBLES

Spectroscopic analysis reveals that gases in tektite bubbles are neon, helium and oxygen

TEKTITE↗

Fluidized bed combustor modeling

A general mathematical model for the prediction of performance of a fluidized bed coal combustor (FBC) is developed. The basic elements of the model consist of: (1) hydrodynamics of gas and solids in the combustor; (2) description of gas and solids contacting pattern; (3) kinetics of combustion; and (4) absorption of SO2 by limestone in the bed. The model is capable of calculating the combustion efficiency, axial bed temperature profile, carbon hold-up in the bed, oxygen and SO2 concentrations in the bubble and emulsion phases, sulfur retention efficiency and particulate carry over by elutriation. The effects of bed geometry, excess air, location of heat transfer coils in the bed, calcium to sulfur ratio in the feeds, etc. are examined. The calculated results are compared with experimental data. Agreement between the calculated results and the observed data are satisfactory in most cases. Recommendations to enhance the accuracy of prediction of the model are suggested.

Horio, M.↗

Hyperpolarized (129)Xe T (1) in oxygenated and deoxygenated blood

The viability of the new technique of hyperpolarized (129)Xe MRI (HypX-MRI) for imaging organs other than the lungs depends on whether the spin-lattice relaxation time, T(1), of (129)Xe is sufficiently long in the blood. In previous experiments by the authors, the T(1) was found to be strongly dependent upon the oxygenation of the blood, with T(1) increasing from about 3 s in deoxygenated samples to about 10 s in oxygenated samples. Contrarily, Tseng et al. (J. Magn. Reson. 1997; 126: 79-86) reported extremely long T(1) values deduced from an indirect experiment in which hyperpolarized (129)Xe was used to create a 'blood-foam'. They found that oxygenation decreased T(1). Pivotal to their experiment is the continual and rapid exchange of hyperpolarized (129)Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles); this necessitated a complicated analysis to extract the T(1) of (129)Xe in blood. In the present study, the experimental design minimizes gas exchange after the initial bolus of hyperpolarized (129)Xe has been bubbled through the sample. This study confirms that oxygenation increases the T(1) of (129)Xe in blood, from about 4 s in freshly drawn venous blood, to about 13 s in blood oxygenated to arterial levels, and also shifts the red blood cell resonance to higher frequency. Copyright 2000 John Wiley & Sons, Ltd. Abbreviations used BOLD blood oxygen level dependent NOE nuclear overhouses effect PO(2) oxygen partial pressure RBC red blood cells RF radio frequency SNR signal-to-noise ratio.

NASA Discipline Life Support Systems↗

Production of Gas Bubbles in Reduced Gravity Environments

In a wide variety of applications such as waste water treatment, biological reactors, gas-liquid reactors, blood oxygenation, purification of liquids, etc., it is necessary to produce small bubbles in liquids. Since gravity plays an essential role in currently available techniques, the adaptation of these applications to space requires the development of new tools. Under normal gravity, bubbles are typically generated by forcing gas through an orifice in a liquid. When a growing bubble becomes large enough, the buoyancy dominates the surface tension force causing it to detach from the orifice. In space, the process is quite different and the bubble may remain attached to the orifice indefinitely. The most practical approach to simulating gravity seems to be imposing an ambient flow to force bubbles out of the orifice. In this paper, we are interested in the effect of an imposed flow in 0 and 1 g. Specifically, we investigate the process of bubble formation subject to a parallel and a cross flow. In the case of parallel flow, we have a hypodermic needle in a tube from which bubbles can be produced. On the other hand, the cross flow condition is established by forcing bubbles through an orifice on a wall in a shear flow. The first series of experiments have been performed under normal gravity conditions and the working fluid was water. A high quality microgravity facility has been used for the second type and silicone oil is used as the host liquid.

Oguz, Hasan N.↗

Probabilistic Assessment of Hypobaric Decompression Sickness Treatment Success

The Hypobaric Decompression Sickness (DCS) Treatment Model links a decrease in computed bubble volume from increased pressure (DeltaP), increased oxygen (O2) partial pressure, and passage of time during treatment to the probability of symptom resolution [P(symptom resolution)]. The decrease in offending volume is realized in 2 stages: a) during compression via Boyle's Law and b) during subsequent dissolution of the gas phase via the O2 window. We established an empirical model for the P(symptom resolution) while accounting for multiple symptoms within subjects. The data consisted of 154 cases of hypobaric DCS symptoms along with ancillary information from tests on 56 men and 18 women. Our best estimated model is P(symptom resolution) = 1 / (1+exp(-(ln(Delta P) - 1.510 + 0.795×AMB - 0.00308×Ts) / 0.478)), where (DeltaP) is pressure difference (psid), AMB = 1 if ambulation took place during part of the altitude exposure, otherwise AMB = 0; and where Ts is the elapsed time in mins from start of the altitude exposure to recognition of a DCS symptom. To apply this model in future scenarios, values of DeltaP as inputs to the model would be calculated from the Tissue Bubble Dynamics Model based on the effective treatment pressure: (DeltaP) = P2 - P1 | = P1×V1/V2 - P1, where V1 is the computed volume of a spherical bubble in a unit volume of tissue at low pressure P1 and V2 is computed volume after a change to a higher pressure P2. If 100% ground level O2 (GLO) was breathed in place of air, then V2 continues to decrease through time at P2 at a faster rate. This calculated value of (DeltaP then represents the effective treatment pressure at any point in time. Simulation of a "pain-only" symptom at 203 min into an ambulatory extravehicular activity (EVA) at 4.3 psia on Mars resulted in a P(symptom resolution) of 0.49 (0.36 to 0.62 95% confidence intervals) on immediate return to 8.2 psia in the Multi-Mission Space Exploration Vehicle. The P(symptom resolution) increased to near certainty (0.99) after 2 hrs of GLO at 8.2 psia or with less certainty on immediate pressurization to 14.7 psia [0.90 (0.83 - 0.95)]. Given the low probability of DCS during EVA and the prompt treatment of a symptom with guidance from the model, it is likely that the symptom and gas phase will resolve with minimum resources and minimal impact on astronaut health, safety, and productivity.

Conkin, Johnny↗

Spiral vane bioreactor

A spiral vane bioreactor of a perfusion type is described in which a vertical chamber, intended for use in a microgravity condition, has a central rotating filter assembly and has flexible membranes disposed to rotate annularly about the filter assembly. The flexible members have end portions disposed angularly with respect to one another. A fluid replenishment medium is input from a closed loop liquid system to a completely liquid filled chamber containing microcarrier beads, cells and a fluid medium. Output of spent medium is to the closed loop. In the closed loop, the output and input parameters are sensed by sensors. A manifold permits recharging of the nutrients and pH adjustment. Oxygen is supplied and carbon dioxide and bubbles are removed and the system is monitored and controlled by a microprocessor.

Morrison, Dennis R.↗

Photographic Study of Liquid-Oxygen Boiling and Gas Injection in the Injector of a Chugging Rocket Engine

High-speed motion pictures were taken of conditions in the injector liquid-oxygen cavity of an RL-10 rocket engine during throttled engine operation. Photographs were taken during operation of the engine in the chugging region as the helium gas was injected to stabilize combustion, during operation at rated thrust, and during transition into chugging conditions as the gas injection was discontinued. Results of the investigation indicate that, during chugging rocket operation of the RL-10 engine, a high population of fairly large bubbles formed and collapsed within the liquid-oxygen cavity at the same frequency as the chamber pressure oscillations. When gaseous helium was injected into the liquid-oxygen cavity, a fog rapidly spread over the entire field of view, and the system immediately became stable. The injection of gaseous helium at rated conditions produced a very slight increase in engine performance but not enough to produce a net gain in a typical mission payload with the extra equipment needed. The inherent low-frequency system instability associated with the fuel system at low thrust levels was reduced by injecting either gaseous helium or hydrogen. Complete stabilization was achieved in some cases, and a reduction in the severity of the oscillations in others. This was apparently due to the ·anchoring of the phase change front to the location of the gas injection.

Conrad, E. William↗

Ambulation Increases Decompression Sickness in Altitude Exposure

INTRODUCTION - Exercise accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of exercise are likely critical to the net effect. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a 4.3 psi exposure in non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity (CEVIS and ISLE). Additional work is required to investigate whether exercise normal to 1 G environments increases the risk of DCS over microgravity simulation. METHODS - The CEVIS protocol was replicated with one exception. Our subjects completed controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining non-ambulatory throughout. Decompression stress was graded with aural Doppler (Spencer 0-IV scale). Two-dimensional echocardiographic imaging was used to look for left heart gas emboli (the presence of which prompted test termination). Venous blood was collected at three points to correlate Doppler measures of decompression stress with microparticle (cell fragment) accumulation. Fisher Exact Tests compared test and control groups. Trial suspension would occur when DCS risk >15% or grade IV venous gas emboli (VGE) risk >20% (at 70% confidence). RESULTS - Eleven person-trials were completed (9 male, 2 female) when DCS prompted suspension. DCS was greater than in CEVIS trials (3/11 [27%] vs. 0/45 [0%], respectively, p=0.03). Statistical significance was not reached for peak grade IV VGE (2/11 [18%] vs. 3/45 [7%], p=0.149) or cumulative grade IV VGE observations per subject-trial (8/128 [6%] vs. 26/630 [4%], p=0.151). Microparticle data were collected for 5/11 trials (3 with DCS outcomes), with widely varying patterns that could not be resolved statistically. CONCLUSION - We did find that that ambulation increases decompression stress. Additional trials would improve the statistical power to assess differences in VGE and to evaluate the relationship between decompression stress and microparticles.

Conkin, Johnny↗

Decompression Sickness During Simulated Low Pressure Exposure is Increased with Mild Ambulation Exercise

Musculoskeletal activity accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation (nucleation) and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity are likely critical to the net effect. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a 4.3 psia exposure in non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity - one employing cycling and non-cycling exercise (CEVIS: 'cycle ergometer vibration isolation system') and one relying on non-cycling exercise only (ISLE: 'in-suit light exercise'). Current efforts investigate whether light exercise normal to 1 G environments increases the risk of DCS over microgravity simulation.

Pollock, N. W.↗

Ambulation Increases Decompression Sickness in Spacewalk Simulations

Musculoskeletal activity has the potential to both improve and compromise decompression safety. Exercise enhances inert gas elimination during oxygen breathing prior to decompression (prebreathe), but it may also promote bubble nuclei formation (nucleation), which can lead to gas phase separation and bubble growth and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation may be critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. Data gathered during NASA's Prebreathe Reduction Program (PRP) studies combined oxygen prebreathe and exercise followed by low pressure (4.3 psi; altitude equivalent of 30,300 ft [9,235 m]) microgravity simulation to produce two protocols used by astronauts preparing for extravehicular activity. Both the Phase II/CEVIS (cycle ergometer vibration isolation system) and ISLE (in-suit light exercise) trials eliminated ambulation to more closely simulate the microgravity environment. The CEVIS results (35 male, 10 female) serve as control data for this NASA/Duke study to investigate the influence of ambulation exercise on bubble formation and the subsequent risk of DCS. METHODS Four experiments will replicate the CEVIS exercise-enhanced oxygen prebreathe protocol, each with a different exception. The first of these is currently underway. Experiment 1 - Subjects complete controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining nonambulatory throughout. Experiment 2 - Subjects remain non-ambulatory during the preflight period and ambulatory at 4.3 psi. Experiment 3 - Subjects ambulate during the preflight period and remain non-ambulatory at 4.3 psi. Experiment 4 - The order of heavy and light exercise employed in the CEVIS protocol is reversed, with the light exercise occurring first (subjects remain non-ambulatory throughout). Decompression stress is assessed with non-invasive ultrasound during each of 14 epochs of a 4 hour simulated spacewalk at 4.3 psi; aural Doppler is used to monitor bubbles (Spencer grade 0-IV scale) passing through the pulmonary artery, and two-dimensional echocardiographic imaging is used to look for left ventricular gas emboli (LVGE; the presence of which is a test termination criterion). Venous blood is collected at baseline and twice following repressurization to determine if the decompression stress is correlated with microparticles (cell fragments) accumulation. The plan is to test 25-50 subjects in each experiment. Fisher Exact Tests (one-tailed) are used to compare test and control groups. Trials are suspended when the DCS or grade IV VGE observations reach 70% confidence of DCS risk >15% and grade IV VGE risk >20%. RESULTS Experiment 1 was concluded with 20 complete trials (15 male, 5 female) since the statistical outcome would not change with five additional trials. The observed DCS was significantly greater in Experiment 1 than in CEVIS trials (4/20 [20%] vs. 0/45 [0%], respectively, p=0.007), as was the frequency of peak grade IV VGE (6/21 [29%; including one additional subject that presented grade IV VGE but whose trial was ended before completion when LVGE were observed] vs. 3/45 [7%], respectively, p=0.024). Experiment 3 trials are now underway, with 11 trials completed (10 male, 1 female). Preliminary results indicate no difference in observed DCS between Experiment 3 and CEVIS trials (1/11 [9%] vs. 0/45 [0%], respectively, p=0.196), or between Experiment 3 and Experiment 1 trials (p=0.405). The frequency of peak grade IV VGE in Experiment 3 (2/11 [18%]) did not differ from CEVIS or Experiment 1 trials (p=0.251 and p=0.425, respectively). Microparticle patterns are widely variable and still under analysis. DISCUSSION The results of the Experiment 1 trials support the thesis that decompression stress is increased by ambulation exercise, given the higher incidence of DCS and grade IV VGE when compared to the non-ambulatory PRP CEVIS trials. Experiment 3 trials are incomplete, but suggest that the effect of ambulation during ground level preflight oxygen breathing alone, when subjects are undersaturated with inert gas, may not differ in risk from ambulation at both preflight and spacesuit pressures, the latter when subjects are supersaturated with inert gas. Further trials are needed to confirm the relative effects of ambulation in undersaturated vs. supersaturated states and to determine whether light exercise facilitates the removal of heavy exercise-induced nucleation (Experiment 4).

Pollock, N. W.↗

Development of a Prototype Algal Reactor for Removing CO2 from Cabin Air

Controlling carbon dioxide in spacecraft cabin air may be accomplished using algal photobioreactors (PBRs). The purpose of this project was to evaluate the use of a commercial microcontroller, the Arduino Mega 2560, for measuring key phot~ioreactor variables: dissolved oxygen, pH, temperature, light, and carbon dioxide. The Arduino platform is an opensource physical computing platform composed of a compact microcontroller board and a C++/C computer language (Arduino 1.0.5). The functionality of the Arduino platform can be expanded by the use of numerous add-ons or 'shields'. The Arduino Mega 2560 was equipped with the following shields: datalogger, BNC shield for reading pH sensor, a Mega Moto shield for controlling CO2 addition, as well as multiple sensors. The dissolved oxygen (DO) probe was calibrated using a nitrogen bubbling technique and the pH probe was calibrated via an Omega pH simulator. The PBR was constructed using a 2 L beaker, a 66 L box for addition of CO2, a micro porous membrane, a diaphragm pump, four 25 watt light bulbs, a MasterFiex speed controller, and a fan. The algae (wild type Synechocystis PCC6803) was grown in an aerated flask until the algae was dense enough to used in the main reactor. After the algae was grown, it was transferred to the 2 L beaker where CO2 consumption and O2 production was measured using the microcontroller sensor suite. The data was recorded via the datalogger and transferred to a computer for analysis.

Patel, Vrajen↗

Comparison of Oxygen Liquefaction Gaseous Oxygen Injection via Ullage and Dip Tube

The Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing demonstrated constant and transient oxygen liquefaction in a scaled lander tank integrated with an industrial cryocooler. Early in the test series, two methods for injecting gaseous oxygen into the test tank were ran under similar constant liquefaction conditions for comparison. Gaseous oxygen was either injected directly from the lid into the ullage or bubbled up through the liquid using a dip tube that extends to the bottom of the test tank. The direct comparison of these gaseous oxygen injection methods for constant liquefaction indicated ullage injection provided a greater liquefaction rate than injection via a dip tube. Injection through the ullage was subsequently selected as the nominal injection method for the CryoFILL test series. The comparison of the two injection methods will be highlighted with a discussion of what may cause the variation in liquefaction rate.

Cryogenic Fluid Management↗