Search NASA⌕ Search

SEARCH · Search NASA

Results for “PDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Keck/OSIRIS Paβ High-contrast Imaging and Updated Constraints on PDS 70b

We present a high-contrast imaging search for Paβ line emission from protoplanets in the PDS 70 system with Keck/OSIRIS integral field spectroscopy. We applied the high-resolution spectral differential imaging technique to the OSIRIS J-band data but did not detect the Paβ line at the level predicted using the parameters of Hashimoto et al. (2020). This lack of Paβ emission suggests the MUSE-based study may have overestimated the line width of Hα. We compared our Paβ detection limits with the previous Hα flux and Hβ limits and estimated AV to be ∼0.9 and 2.0 for PDS 70 b and c, respectively. In particular, PDS 70 b’s AV is much smaller than implied by high-contrast near-infrared studies, which suggests the infrared-continuum photosphere and the hydrogen-emitting regions exist at different heights above the forming planet.

Taichi Uyama↗

Photographic stellar photometry with the PDS microdensitometer

A technique for photographic stellar photometry with the PDS microdensitometer is described. It employs a least-squares fit to a model density profile to derive an instrumental magnitude index, an image-abnormality index, and the local value of the background density for each image. The instrumental magnitude index is calibrated in terms of true magnitude by the same methods as for iris photometry. A preliminary test of the method using plates of the open cluster NGC 188 indicates that a precision comparable to or slightly better than that of conventional iris photometry or other methods of PDS reduction may easily be attained. Possibilities for the future elaboration of the technique are mentioned.

Stetson, P. B.↗

Experiences with a PDS 2020 GM

Various perturbations which occurred during the operation of a PDS 2020 GM microdensitometer are reviewed. The effects of elevated temperature, vibration, transient electrical noise, and photometric perturbations are briefly discussed. Sample astronomical results from the PDS 2020 GM unit are presented.

Teuber, D.↗

PDS concepts and astronomical applications: An overview

The basic concepts of PDS scanning microdensitometers; including their major electronic, optical, and mechanical variations; are reviewed herein. An overview of the alterations made to the basic PDS design to improve the collection of astronomical data is presented.

Lasker, B. M.↗

The PDS for space telescope guide star selection system: Status and improvements

Pointing the ST (Space Telescope) requires that the onboard guidance system be provided with the coordinates and magnitudes of at least two guide stars for each observation region. The accuracy and limitations of the model 2020G PDS microdensitometer are assessed in view of the guide star requirements of the space telescope. Modifications of the PDS to correct for measuring errors are reviewed.

Kinsey, J. H.↗

An improved logarithmic amplifier circuit for PDS microdensitometers

A high speed logarithmic amplifier circuit for the Perkin-Elmer PDS microdensitometer is discussed. The circuit is designed around an Analog Devices 757p log-amp module. The amplifier produces undistorted profiles of rapidly changing, dense ( 4) images over the available range of scanning speeds. The circuit board was designed to replace directly the manufacturer supplied unit; neither electrical nor mechanical modifications of the basic PDS are required. The performance of the circuit is illustrated through its effects on the overall modulation transfer function of the instrument and by scans of a well exposed stellar image. Circuit diagrams and parts lists a mechanism for obtaining either circuit board layout art work or finished circuit boards are presented.

Anderson, C. M.↗

The PDS-VAX intelligent plate scanning system of Trieste Astronomical Observatory

An intelligent subsystem for interfacing a PDS1010A digital microdensitometer to a DEC DR11W DMA 16 bit UNIBUS port in DEC VAX VMS environment was tested. The subsystem employs two MOTOROLA M68000 microprocessors with 128 KB data memory. The PDS primitives and the user defined high level scanning functions and preprocessing modules are loaded from the host computer into two 8 KB RAM memories in the microprocessors using a dedicated PDS control language. The subsystem is planned to employ a nonstandard photomultiplier electronics. Two design schemes were tested: (1) based on three amplifiers of gain 10 cascaded and multiplexed to a 12 bit AD converter, and (2) based on a single amplifier of gain 100 and two 14 bit AD converters.

Pucillo, M.↗

The VAX/VMS device driver and user operation program for the Midwestern Astronomical Data Reduction and Analysis Facility PDS microdensitometer

The Midwestern astronomical data reduction and analysis facility (MADRAF) PDS microdensitometer which was the first astronomical PDS which was provided with a Motorola 6800 microprocessor control/interface and will be interfaced to a 32-bit instruction computer operating in a multiuser environment is outlined. Command and response handshaking are handled on an RS 232 serial line while data transfer occurs on a dedicated Direct Memory Access line. This set of conditions necessitated the creation of a specialized device for the system. The general outline of this software is discussed. The availability of an extraordinarily powerful computer opened the possibility of a user operating program of great versatility with diverse data destinations and formats, automatic documentation, and an extensive set of utilities which facilitate operations.

Anderson, C. M.↗

Why use a microdensitometer other than a PDS?

The motivations for constructing a special purpose built microdensitometer are explored. The salient points of some of the microdensitometers are described and the advantages and disadvantages of the system in comparison to a PDS machine are outlined. The principal gain is in speed though at the expense of loss in dynamic range. The effects on the astronomical results are demonstrated. The astronomical results already obtained with these machines and from ongoing projects are described. It is shown that there is a large class of important astronomical problems which can be tackled by these machines but which are not feasibile on the PDS because of the speed of the machine.

Stobie, R. S.↗

An improved logarithmic amplifier circuit for PDS microdensitometers

A high-speed logarithmic-amplifier circuit for a PDS microdensitometer is discussed. The circuit is designed around a 757P log-amp module which replaces the FMI 531 'Negative Log/Anti-log' device of the original. The new amplifier is capable of producing undistorted profiles of rapidly changing, dense images over the available range of scanning speeds. The circuit board has been designed to directly replace the manufacturer supplied unit; neither electrical nor mechanical modifications of the basic PDS are required. The performance of the circuit is illustrated through its effects on the overall Modulation Transfer Function of the instrument and by scans of a well-exposed stellar image. Circuit diagrams and parts lists are presented.

Anderson, C. M.↗

Non-Thermal Hard X-Ray Emission in Galaxy Clusters Observed with the BeppoSAX PDS

We study the X-ray emission in a Sample of galaxy clusters using the BeppoSAX PDS instrument in the 20 - 80 keV energy band. We estimate the non-thermal hard X-ray cluster emission (HXR) by modeling the thermal contribution from the cluster gas and the non-thermal contamination from the unobscured AGN in the clusters. We also evaluate the systematic uncertainties due to the background fluctuations. Assuming negligible contamination from the obscured AGN, the resulting non-thermal component is detected at a 2 sigma level in approx. 50% of the non-significantly AGN-contaminated clusters: A2142, A2199, A2256, A3376, Coma, Ophiuchus and Virgo. The data are consistent with a scenario whereby relaxed clusters have no hard X-ray component of non-thermal origin, whereas merger clusters do. The co-added spectrum of the above clusters indicates a power-law spectrum for the HXR with a photon index of 2.8+0.3-0.4 in the 12 - 115 keV band, and we find indication that it has extended distribution. These indications argue against significant contamination from obscured AGN, which have harder spectra and centrally concentrated distribution. These results are supportive of the assumption of the merger shock acceleration of electrons in clusters, which has been proposed as a possible origin of the non-thermal hard X-ray emission models. Assuming that the Cosmic Microwave Background photons experience Inverse Compton scattering from the merger-accelerated relativistic electrons, and thus produce the observed HXR, the measured hard X-ray slope corresponds to a differential momentum spectra of the relativistic electrons with a slope of mu = 3.8 - 5.0. In presence of cluster magnetic fields this relativistic electron population produces synchrotron emission with a spectral index of 1.4 - 2.1, consistent with radio halo observations of merger clusters. Thus both hard X-ray and radio observations of merger clusters are consistent with the Inverse Compton model. The observed slope of HXR is also consistent with that predicted by the non-thermal bremsstrahlung, which chus cannot be ruled by the fit to the current data, even though this model requires an extreme, untenable cluster energetics. Assuming centrally concentrated distribution of HXR, the data requires a harder slope for the HXR spectrum, which is consistent with secondary electron models, but this model yields a worse fit to the PDS data and thus seems to be disfavored over the primary electron Inverse Compton model.

Nevalainen, J.↗

Restoration and PDS Archive of Apollo Lunar Rock Sample Data

In 2008, scientists at the Johnson Space Center (JSC) Lunar Sample Laboratory and Image Science & Analysis Laboratory (under the auspices of the Astromaterials Research and Exploration Science Directorate or ARES) began work on a 4-year project to digitize the original film negatives of Apollo Lunar Rock Sample photographs. These rock samples together with lunar regolith and core samples were collected as part of the lander missions for Apollos 11, 12, 14, 15, 16 and 17. The original film negatives are stored at JSC under cryogenic conditions. This effort is data restoration in the truest sense. The images represent the only record available to scientists which allows them to view the rock samples when making a sample request. As the negatives are being scanned, they are also being formatted and documented for permanent archive in the NASA Planetary Data System (PDS) archive. The ARES group is working collaboratively with the Imaging Node of the PDS on the archiving.

Garcia, P. A.↗

Resolving the Soft X-Ray Ultrafast Outflow in PDS 456

Past X-ray observations of the nearby luminous quasar PDS 456 (at z = 0.184) have revealed a wide-angle accretion disk wind with an outflow velocity of ∼−0.25c, as observed through observations of its blueshifted iron K-shell absorption line profile. Here we present three new XMM-Newton observations of PDS 456: one in 2018 September where the quasar was bright and featureless and two in 2019 September, 22 days apart, occurring when the quasar was five times fainter and where strong blueshifted lines from the wind were present. During the second 2019 September observation, three broad (σ = 3000 km s(exp -1)) absorption lines were resolved in the high-resolution Reflection Grating Spectrometer spectrum that are identified with blueshifted O VIII Lyα, Ne IX Heα, and Ne X Lyα. The outflow velocity of this soft X-ray absorber was found to be v/c = -0.258 ± 0.003, fully consistent with an iron K absorber with v/c = -0.261 ± 0.007. The ionization parameter and column density of the soft X-ray component (log ξ = 3.4, N(sub H) = 2 × 10(exp 21) cm(exp -2)) outflow was lower by about 2 orders of magnitude when compared to the high-ionization wind at iron K (log ξ = 5, N(sub H) = 7 × 10(exp 23) cm(exp -2). Substantial variability was seen in the soft X-ray absorber between the 2019 observations, declining from N(sub H) = 10(exp 23) to 10(exp 21) cm(exp -2) over 20 days, while the iron K component was remarkably stable. We conclude that the soft X-ray wind may originate from an inhomogeneous wind streamline passing across the line of sight that, due to its lower ionization, is located further from the black hole, on parsec scales, than the innermost disk wind

Active galactic nuclei↗

Operators manual for microdensitometer control program densitometer model PDS-1010G (modified). Program trace version 3B (section 3)

The PDS-1010G microdensitometer is run under the control of a PDP-11 program called TRACE. This program gives the operator vary flexible control over the machine functions. Most commands are passed to the computer through either the Tektronix 4010 terminal or the teletype, as selected by the position of the LOCAL/LINE rocker switch above the 4010 keyboard. (LINE places the 4010 in control; LOCAL transfers control to the teletype. In general, the teletype is used when the operator desires a permanent record of the operator-computer dialogue.) A small number of control functions are requested by setting switches on the computer front panel.

Title, A. M.↗

Diagnosing a PDS microdensitometer

A number of diagnostic tests are developed for the Photometric Data System PDS 2020G microdensitometer to monitor its performance and to isolate various electromechanical problems. A number of tests which help to diagnose problems with the photometer, positional accuracy and data collection are described. The tests include: (1) scanning a razor blade edge to study the response of the photometer and zero point losses in the coordinate system, (2) scanning a long straight line to evaluate the drunkness of the stage motions, (3) scanning photometric step wedge calibrations to study the response of the photometer, and (4) measurement of a series of high signal to noise plates of the same region of the sky to evaluate the overall performance of the microdensitometer. A variety of electronic tests to isolate electromechanical problems are also performed.

Vanaltena, W.↗

Characteristics of the MSFC, PDS microdensitometer

The results of several parametric studies carried out on the Marshall Space Flight Center (MSFC) Photometric Data System PDS-10 microdensitometer are summarized for the purposes of documenting the operation and limitations of the system for inhouse research and to provide a bench mark for comparison with other microdensitometers. The results are grouped into four general areas. These are: (1) system overall stability to drift, (2) photometric linearity and noise, (3) reproducibility, and (4) scanning performance. Test data taken in order to evaluate the interdependency of scan speed, noise and position are included. Shown also are results of tests for system stability, reproducibility, stray light and PMT settling time.

Fountain, W. F.↗

Performance of the ESO PDS

The astrometric and photometric performance of the PDS 1010A microdensitometer are discussed, including the tests used for checking it. The instrument was shown to satisfy operational requirements for photometric measurements of astronomical plates with respect to dynamic range and stability.

Grosboel, P. J.↗