Plasma formation in atmospheric pressure helium discharges under different background air pressures
Atmospheric pressure glow discharges generated between parallel-plate electrodes in helium have been characterized using temporally resolved emission spectra. The variation of typical spectral lines over time has been analyzed. In helium with a low concentration of N{sub 2}, the emission of He at 706.5 nm is dominant and appears 500 ns earlier than N{sub 2}{sup +} first negative bands, indicating low reaction rates of Penning ionization and charge transfer in the initial stage. During the decay, it is the Penning ionization caused by He metastables with a long lifetime rather than the charge transfer reaction that leads to the long decay of N{sub 2}{sup +} emissions. When helium contains a higher concentration of N{sub 2} molecules, the N{sub 2}{sup +} first negative bands become the most intense, and emissions from He, N{sub 2}{sup +}, and O exhibit similar behavior as they increase. The emissions last for a shorter time under such conditions because of rapid consumption of He metastables and He{sub 2}{sup +}.