Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERIPHERAL MODELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Model of human dynamic orientation

The dynamics associated with the perception of orientation were modelled for near-threshold and suprathreshold vestibular stimuli. A model of the information available at the peripheral sensors which was consistent with available neurophysiologic data was developed and served as the basis for the models of the perceptual responses. The central processor was assumed to utilize the information from the peripheral sensors in an optimal (minimum mean square error) manner to produce the perceptual estimates of dynamic orientation. This assumption, coupled with the models of sensory information, determined the form of the model for the central processor. The problem of integrating information from the semi-circular canals and the otoliths to predict the perceptual response to motions which stimulated both organs was studied. A model was developed which was shown to be useful in predicting the perceptual response to multi-sensory stimuli.

Ormsby, C. C.↗

Development of an in-vitro circulatory system with known resistance and capacitance

An in-vitro (hydrodynamic) model of the circulatory system was developed. The model consisted of a pump, compliant tubing, and valves for resistance. The model is used to simulate aortic pressure and flow. These parameters were measured using a Konigsburg Pressure transducer and a Triton ART2 flow probe. In addition, venous pressure and flow were measured on the downstream side of the resistance. The system has a known compliance and resistance. Steady and pulsatile flow tests were conducted to determine the resistance of the model. A static compliance test was used to determine the compliance of the system. The aortic pressure and flow obtained from the hydrodynamic model will be used to test the accuracy of parameter estimation models such as the 2-element and 4-element Windkessel models and the 3-element Westkessel model. Verifying analytical models used in determining total peripheral resistance (TPR) and systemic arterial compliance (SAC) is important because it provides insight into hemodynamic parameters that indicate baroreceptor responsiveness to situations such as changes in gravitational acceleration.

NASA Discipline Cardiopulmonary↗

Investigation of anti-motion sickness drugs in the squirrel monkey

Early attempts to develop an animal model for anti-motion sickness drugs, using dogs and cats; were unsuccessful. Dogs did not show a beneficial effect of scopolamine (probably the best single anti-motion sickness drug for humans thus far) and the findings in cats were not definitive. The authors have developed an animal model using the squirrel monkey (Saimiri sciureus) of the Bolivian phenotype. Unrestrained monkeys in a small lucite cage were tested in an apparatus that induces motion sickness by combining vertical oscillation and horizontal rotation in a visually unrestricted laboratory environment. Signs of motion sickness were scored using a rating scale. Ten susceptible monkeys (weighing 800-1000 g) were given a total of five tests each, to establish the baseline susceptibility level. Based on the anticholinergic activity of scopolamine, the sensitivity of squirrel monkey to scopolamine was investigated, and the appropriate dose of scopolamine for this species was determined. Then various anti-motion sickness preparations were administered in subsequent tests: 100 ug scopolamine per monkey; 140 ug dexedrine; 50 ug scopolamine plus 70 ug dexedrine; 100 ug scopolamine plus 140 ug dexedrine; 3 mg promethazine; 3 mg promethazine plus 3 mg ephedrine. All these preparations were significantly effective in preventing motion sickness in the monkeys. Ephedrine, by itself, which is marginally effective in humans, was ineffective in the monkeys at the doses tried (0.3-6.0 mg). The squirrel monkey appears to be a good animal model for antimotion sickness drugs. Peripherally acting antihistamines such as astemizole and terfenadine were found to be ineffective, whereas flunarizine, and an arginine vasopressin V1 antagonist, showed significant activity in preventing motion sickness.

NASA Discipline Neuroscience↗

Study of the ablative effects on tektites: Atmosphere entry of a swarm of tektites

The large variety of ablation markings observed on recovered tektites lead to the previously proposed swarm wake model which states that the lead peripheral tektites bore the blunt of aerodynamic heating upon entry, and that the bulk of tektites in the wake enjoyed partial shielding at the expense of the leaders. Further considerations are presented in support of this model. Quantitative assessments indicate that wake shielding might indeed have provided for substantially less heating than would have been experienced by a tektite entering an undisturbed atmosphere along a similar trajectory. For the case of strong wake shielding it is even possible that the surface temperature of a falling tektite had barely reached its melting point. In the distribution of tektites, there is a size band (near R = 0.5 cm) which is least susceptible to melting.

Sepri, P.↗

Evaluation of Flow Biosensor Technology in a Chronically-Instrumented Non-Human Primate Model

The Physiology Research Branch of Brooks AFB conducts both human and non-human primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to indentify the particular mechanisms that invoke these responses. Primary investigative research efforts in a non-human primate model require the calculation of total peripheral resistance (TPR), systemic arterial compliance (SAC), and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. We have evaluated commercially available electromagnetic (EMF) and transit-time flow measurement techniques. In vivo and in vitro experiments demonstrated that the average error of these techniques is less than 25 percent for EMF and less than 10 percent for transit-time.

SC Koenig↗

Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

Non-NASA Center↗

Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model

The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.

Non-NASA Center↗

Corona structures on Venus - Models of origin

The present study assesses the mantle diapir models of corona origin using the basic characteristics of coronas: relatively raised topography, annuli of compressional ridges, volcanism, and peripheral trough. Both rising and and sinking diapirs are modeled quantitatively. Rising mantle diapirs are caused by heating at depth, while sinking mantle diapirs may result from cooling or a phase change causing increased density and negative buoyancy at the base of the lithosphere. The hotspot model is most consistent with the major characteristics of coronas, with gravitational relaxation occurring as a modificational process. The sinking mantle diapir produces dominant central compression that is not observed at coronas. Higher-resolution image and altimetry data from Magellan can be used to distinguish more fully between the two models. Coronas in various states of formation and degradation can be identified in the Venera 15/16 data, suggesting that the process may be continuing today.

Stofan, Ellen R.↗

Cooperative Effects of Corticosteroids and Catecholamines upon Immune Deviation of the Type-1/Type-2 Cytokine Balance in Favor of Type-2 Expression in Human Peripheral Blood Mononuclear Cells

A growing number of studies show strong associations between stress and altered immune function. In vivo studies of chronic and acute stress have demonstrated that cognitive stressors are strongly correlated with high levels of catecholamines (CT) and corticosteroids (CS). Although both CS and CT individually can inhibit the production of T-helper 1 (TH1, type-1 like) cytokines and simultaneously promote the production of T-helper 2 (TH2, type-2 like) cytokines in antigen-specific and mitogen stimulated human leukocyte cultures in vitro, little attention has been focused on the effects of combination CT and CS in immune responses that may be more physiologically relevant. We therefore investigated the combined effects of in vitro CT and CS upon the type-1/type-2 cytokine balance of human peripheral blood mononuclear cells (PBMC) as a model to study the immunomodulatory effects of superimposed acute and chronic stress. Results demonstrated a significant decrease in type-1 cytokine production (IFN-gamma) and a significant increase in type-2 cytokine production (IL-4, IL-10) in our CS+CT incubated cultures when compared to either CT or CS agents alone. Furthermore, variable enhancement of type-1/type-2 immune deviation occurred depending upon when the CT was added. The data suggest that CS can increase the sensitivity of PBMC to the immunomodulatory effects of CT and establishes an in vitro model to study the combined effects of in vivo type-1/type-2 cytokine alterations observed in acute and chronic stress.

Salicru, A. N.↗

Theoretical shell-model signatures in heavy-ion, coherent pion production

A comprehensive summary of a many-body, microscopic, particle-hole formalism is presented that describes coherent, subthreshold, pion production in peripheral, heavy-ion collisions. The formalism uses a new separable model transition interaction that produces Delta-hole states in either the projectile or target nucleus. Shell-model states described by harmonic oscillator functions are used in the calculation of Delta formation and decay and Lorentz-contraction effects of the nucleus not at rest are included. An analytical expression to lowest multipole order for the differential cross section is examined. The sensitivity of the theoretical results to the shell-model states is determined with preliminary shape results compared with data. The effects of higher multipoles are examined with attention paid to the second-order multipole value.

Maung, Khin M.↗

Manual control of yaw motion with combined visual and vestibular cues

Measurements are made of manual control performance in the closed-loop task of nulling perceived self-rotation velocity about an earth-vertical axis. Self-velocity estimation was modelled as a function of the simultaneous presentation of vestibular and peripheral visual field motion cues. Based on measured low-frequency operator behavior in three visual field environments, a parallel channel linear model is proposed which has separate visual and vestibular pathways summing in a complementary manner. A correction to the frequency responses is provided by a separate measurement of manual control performance in an analogous visual pursuit nulling task. The resulting dual-input describing function for motion perception dependence on combined cue presentation supports the complementary model, in which vestibular cues dominate sensation at frequencies above 0.05 Hz. The describing function model is extended by the proposal of a non-linear cue conflict model, in which cue weighting depends on the level of agreement between visual and vestibular cues.

Zacharias, G. L.↗

Influence of combined visual and vestibular cues on human perception and control of horizontal rotation

Measurements are made of manual control performance in the closed-loop task of nulling perceived self-rotation velocity about an earth-vertical axis. Self-velocity estimation is modeled as a function of the simultaneous presentation of vestibular and peripheral visual field motion cues. Based on measured low-frequency operator behavior in three visual field environments, a parallel channel linear model is proposed which has separate visual and vestibular pathways summing in a complementary manner. A dual-input describing function analysis supports the complementary model; vestibular cues dominate sensation at higher frequencies. The describing function model is extended by the proposal of a nonlinear cue conflict model, in which cue weighting depends on the level of agreement between visual and vestibular cues.

Zacharias, G. L.↗

Evaluation of early recognition of viral infections in man

The potential of Lymphocyte Specific Gravity Distribution (LSGD) as a non-specific procedure for early diagnosis of viral disease in astronauts is considered. Results of experiments and a literature search show that several virus diseases result in distinctive changes in the specific gravity distribution of peripheral blood lymphocytes as a result of disease process and associated immune response. A tentative model is proposed which relates the shape of LSGD to the identity of subpopulations of peripheral lymphocytes in a preclinical viral disease situation.

Kelton, A. A.↗

Human Motion Tracking and Glove-Based User Interfaces for Virtual Environments in ANVIL

The Army/NASA Virtual Innovations Laboratory (ANVIL) at Marshall Space Flight Center (MSFC) provides an environment where engineers and other personnel can investigate novel applications of computer simulation and Virtual Reality (VR) technologies. Among the many hardware and software resources in ANVIL are several high-performance Silicon Graphics computer systems and a number of commercial software packages, such as Division MockUp by Parametric Technology Corporation (PTC) and Jack by Unigraphics Solutions, Inc. These hardware and software platforms are used in conjunction with various VR peripheral I/O (input / output) devices, CAD (computer aided design) models, etc. to support the objectives of the MSFC Engineering Systems Department/Systems Engineering Support Group (ED42) by studying engineering designs, chiefly from the standpoint of human factors and ergonomics. One of the more time-consuming tasks facing ANVIL personnel involves the testing and evaluation of peripheral I/O devices and the integration of new devices with existing hardware and software platforms. Another important challenge is the development of innovative user interfaces to allow efficient, intuitive interaction between simulation users and the virtual environments they are investigating. As part of his Summer Faculty Fellowship, the author was tasked with verifying the operation of some recently acquired peripheral interface devices and developing new, easy-to-use interfaces that could be used with existing VR hardware and software to better support ANVIL projects.

Joseph D. Dumas, II↗

Stress analysis of the space telescope focal plane structure joint

Two major efforts were begun concerning the Space Telescope focal plane structure joint. The 3-D solid finite element modeling of the bipod flexure plate was carried out. Conceptual models were developed for the load transfer through the three major bolts to the flexure plate. The flexure plate drawings were reconstructed using DADAM for the purpose of developing a file from which the coordinates of any point on the flexure plate could be determined and also to locate the attachment points of the various components which connect with the flexure plate. For modeling convenience the CADAM drawing of the flexure plate has been divided into several regions which will be subdivided into finite elements using MSGMESH, which is a finite element mesh generator available with MSC/NASTRAN. In addition to the CADAM work on the flexure plate, an effort was also begun to develop computer aided drawings of the peripheral beam which will be used to assist in modeling the connection between it and the flexure plate.

Foster, W. A., Jr.↗

Coronae on Venus observations and models of origin

The Venera 15/16 spacecraft revealed a number of features of unknown origin including coronae, elongate to circular structures with a complex interior surrounded by an annulus of concentric ridges. Eighteen coronae were identified in Venera 15/16 data of Venus; an additional thirteen possible coronae are found in Pioneer Venus and Arecibo data. Coronae, with maximum widths of 160 to over 650 km, are found primarily in two clusters in the Northern Hemisphere located to the east and west of Ishtar Terra. Another possible cluster is located in Themis Regio in the Southern Hemisphere. The majority of coronae are at least partially raised less than 1.5 km above the surrounding region, and over half are partially surrounded by a peripheral trough. A sequence of events for coronae has been determined through mapping. Prior to corona formation, regional compression or extension creates bands of lineaments along which coronae tend to later form. During the early stages of corona formation, relatively raised topography is produced by uplift and volcanic construction. The evolution of coronae and their general characteristics have been compared to two models of corona origin: hotspots and sinking mantle diapirs. In the hotspot or rising mantle diapir model, heating and melting at depth create uplift at the surface. Uplift is accompanied by central extension, facilitating volcanism. Gravitational relaxation of the uplifted region follows producing the compressional features within the annulus and the peripheral trough. Both models can predict the major characteristics and evolutionary sequence of coronae. The sinking diapir model does predict an early-time low and central compression as well as broadening and shallowing of the peripheral trough with time, all of which are not observed at current data resolution. In addition, the sinking mantle diapir mode predicts more simultaneous formation of the high topography, annulus and trough unlike the hotspot or rising mantle diapir mode. High resolution Magellan data will be used to distinguish between the two models of corona origin.

Stofan, E. R.↗

Modeling of the HiPco process for carbon nanotube production. II. Reactor-scale analysis

The high-pressure carbon monoxide (HiPco) process, developed at Rice University, has been reported to produce single-walled carbon nanotubes from gas-phase reactions of iron carbonyl in carbon monoxide at high pressures (10-100 atm). Computational modeling is used here to develop an understanding of the HiPco process. A detailed kinetic model of the HiPco process that includes of the precursor, decomposition metal cluster formation and growth, and carbon nanotube growth was developed in the previous article (Part I). Decomposition of precursor molecules is necessary to initiate metal cluster formation. The metal clusters serve as catalysts for carbon nanotube growth. The diameter of metal clusters and number of atoms in these clusters are some of the essential information for predicting carbon nanotube formation and growth, which is then modeled by the Boudouard reaction with metal catalysts. Based on the detailed model simulations, a reduced kinetic model was also developed in Part I for use in reactor-scale flowfield calculations. Here this reduced kinetic model is integrated with a two-dimensional axisymmetric reactor flow model to predict reactor performance. Carbon nanotube growth is examined with respect to several process variables (peripheral jet temperature, reactor pressure, and Fe(CO)5 concentration) with the use of the axisymmetric model, and the computed results are compared with existing experimental data. The model yields most of the qualitative trends observed in the experiments and helps to understanding the fundamental processes in HiPco carbon nanotube production.

Validation Studies↗

Effects of hindlimb unweighting on the mechanical and structure properties of the rat abdominal aorta

Previous studies have shown that hindlimb unweighting of rats, a model of microgravity, reduces evoked contractile tension of peripheral conduit arteries. It has been hypothesized that this diminished contractile tension is the result of alterations in the mechanical properties of these arteries (e.g., active and passive mechanics). Therefore, the purpose of this study was to determine whether the reduced contractile force of the abdominal aorta from 2-wk hindlimb-unweighted (HU) rats results from a mechanical function deficit resulting from structural vascular alterations or material property changes. Aortas were isolated from control (C) and HU rats, and vasoconstrictor responses to norepinephrine (10(-9)-10(-4) M) and AVP (10(-9)-10(-5) M) were tested in vitro. In a second series of tests, the active and passive Cauchy stress-stretch relations were determined by incrementally increasing the uniaxial displacement of the aortic rings. Maximal Cauchy stress in response to norepinephrine and AVP were less in aortic rings from HU rats. The active Cauchy stress-stretch response indicated that, although maximum stress was lower in aortas from HU rats (C, 8.1 +/- 0.2 kPa; HU, 7.0 +/- 0.4 kPa), it was achieved at a similar hoop stretch. There were also no differences in the passive Cauchy stress-stretch response or the gross vascular morphology (e.g., medial cross-sectional area: C, 0.30 +/- 0.02 mm(2); HU, 0.32 +/- 0.01 mm(2)) between groups and no differences in resting or basal vascular tone at the displacement that elicits peak developed tension between groups (resting tension: C, 1.71 +/- 0.06 g; HU, 1.78 +/- 0.14 g). These results indicate that HU does not alter the functional mechanical properties of conduit arteries. However, the significantly lower active Cauchy stress of aortas from HU rats demonstrates a true contractile deficit in these arteries.

Non-NASA Center↗