Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERSONAL COMPUTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Implementation of data acquisition interface using on-board field-programmable gate array (FPGA) universal serial bus (USB) link

Typically a system consists of hardware as the controller and software which is installed in the personal computer (PC). In the effective nuclear detection, the hardware involves the detection setup and the electronics used, with the software consisting of analysis tools and graphical display on PC. A data acquisition interface is necessary to enable the communication between the controller hardware and PC. Nowadays, Universal Serial Bus (USB) has become a standard connection method for computer peripherals and has replaced many varieties of serial and parallel ports. However the implementation of USB is complex. This paper describes the implementation of data acquisition interface between a field-programmable gate array (FPGA) board and a PC by exploiting the USB link of the FPGA board. The USB link is based on an FTDI chip which allows direct access of input and output to the Joint Test Action Group (JTAG) signals from a USB host and a complex programmable logic device (CPLD) with a 24 MHz clock input to the USB link. The implementation and results of using the USB link of FPGA board as the data interfacing are discussed.

42 ENGINEERING↗

Real-time geo-registration of imagery using COTS graphics processors

A method of performing real-time geo-registration of high-resolution digital imagery using existing graphics processing units (GPUs) already found in current personal computers, rather than the main central processing unit (CPU). Digital image data captured by a camera (along with inertial navigation system (INS) data associated with the image data) is transferred to and processed by the GPU to perform the calculations involved in transforming the captured image into a geo-rectified, nadir-looking image. By using the GPU, the order-of-magnitude increase in throughput over conventional software techniques makes real-time geo-registration possible without the significant cost of custom hardware solutions.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Computer-Aided Design of Organic Host Architectures for Selective Chemosensors

Selective organic hosts provide the foundation for the development of many types of sensors. The deliberate design of host molecules with predetermined selectivity, however, remains a challenge in supramolecular chemistry. To address this issue we have developed a de novo structure-based design approach for the unbiased construction of complementary host architectures. This chapter summarizes recent progress including improvements on a computer software program, HostDesigner, specifically tailored to discover host architectures for small guest molecules. HostDesigner is capable of generating and evaluating millions of candidate structures in minutes on a desktop personal computer, allowing a user to rapidly identify three-dimensional architectures that are structurally organized for binding a targeted guest species. The efficacy of this computational methodology is illustrated with a search for cation hosts containing aliphatic ether oxygen groups and anion hosts containing urea groups.

99 GENERAL AND MISCELLANEOUS↗

ASSESSMENT OF RADIONUCLIDES DATABASES IN CAP88 MAINFRAME VERSION 1.0 AND WINDOWS-BASED VERSION 3.0

In this study the radionuclide databases for two versions of the Clean Air Act Assessment Package-1988 (CAP88) computer model were assessed in detail. CAP88 estimates radiation dose and the risk of health effects to human populations from radionuclide emissions to air. This program is used by several Department of Energy (DOE) facilities to comply with National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations. CAP88 Mainframe, referred to as Version 1.0 on the Environmental Protection Agency (EPA) website (http://www.epa.gov/radiation/assessment/CAP88/), was the very first CAP88 version released in 1988. Some DOE facilities including the Savannah River Site still employ this version (1.0) while others use the more user-friendly personal computer Windows-based Version 3.0 released in December 2007. Version 1.0 uses the program RADRISK based on International Commission on Radiological Protection (ICRP) Publication 30 as its radionuclide database. Version 3.0 uses half-life, dose and risk factor values based on Federal Guidance Report 13. Differences in these values could cause different results for the same input exposure data (same scenario), depending on which version of CAP88 is used. Consequently, the differences between the two versions are being assessed in detail at Savannah River National Laboratory. The version 1.0 and 3.0 database files contain 496 and 838 radionuclides, respectively, and though one would expect the newer version to include all the 496 radionuclides, thirty-five radionuclides are listed in version 1.0 that are not included in version 3.0. The majority of these has either extremely short or long half-lives or is no longer in production; however, some of the short-lived radionuclides might produce progeny of great interest at DOE sites. In addition, one hundred and twenty-two radionuclides were found to have different half-lives in the two versions, with 21 over 3 percent different and 12 over 10 percent different.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High resolution gamma ray tomography scanner for flow measurement and non-destructive testing applications

We report on the development of a high resolution gamma ray tomography scanner that is operated with a Cs-137 isotopic source at 662 keV gamma photon energy and achieves a spatial image resolution of 0.2 line pairs/mm at 10% modulation transfer function for noncollimated detectors. It is primarily intended for the scientific study of flow regimes and phase fraction distributions in fuel element assemblies, chemical reactors, pipelines, and hydrodynamic machines. Furthermore, it is applicable to nondestructive testing of larger radiologically dense objects. The radiation detector is based on advanced avalanche photodiode technology in conjunction with lutetium yttrium orthosilicate scintillation crystals. The detector arc comprises 320 single detector elements which are operated in pulse counting mode. For measurements at fixed vessels or plant components, we built a computed tomography scanner gantry that comprises rotational and translational stages, power supply via slip rings, and data communication to the measurement personal computer via wireless local area network.

36 MATERIALS SCIENCE↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of and control measures for, e-waste in Hong Kong

While accurately estimating electrical and electronic waste (e-waste) generation is important for building appropriate infrastructure for its collection and recycling, making reliable estimates of this kind is difficult in Hong Kong owing to the fact that neither accurate trade statistics nor sales data of relevant products are available. In view of this, data of e-products consumption at household level was collected by a tailor-made questionnaire survey from the public for obtaining a reasonable e-waste generation estimate. It was estimated that on average no more than 80,443 tonnes (11.5 kg/capita) of waste is generated from non-plasma and non-liquid crystal display televisions, refrigerators, washing machines, air-conditioners and personal computers each year by Hong Kong households. However, not more than 17% of this is disposed as waste despite a producer responsibility scheme (PRS) not being in place because of the existence of a vibrant e-waste trading sector. The form of PRS control that can possibly win most public support is one that would involve the current e-waste traders as a major party in providing the reverse logistics with a visible recycling charge levied at the point of importation. This reverse logistic service should be convenient, reliable and highly accessible to the consumers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A computer test bench for checking and adjusting the automatic regulators of generator excitation systems

A computer test bench for testing and debugging natural samples of the automatic excitation regulation systems of generators, the protection units and the power part of the excitation system is described. The bench includes a personal computer with specialized input-output circuit boards for analog and digital signals, and enables the time and cost involved in developing and checking control systems to be reduced considerably. The program employed operates in real time and enables the automatic excitation regulators of synchronous generators and generators with longitudinal-transverse excitation in a specific power system to be adjusted.

42 ENGINEERING↗

Evaluation of Effective Dose During Abdominal Three-Dimensional Imaging for Three Flat-Panel-Detector Angiography Systems

The purpose of this study was to evaluate the effective dose during abdominal three-dimensional (3D) imaging on phantoms and estimate the dose-area product (DAP) for effective dose conversion factors for three types of angiographic units. Three-dimensional imaging was performed for three sizes (small, medium, large) of human-shaped phantoms using three types of angiographic units (Allura Xper FD20/10, INNOVA 4100, AXIOM Artis dTA). We calculated 25 organ doses and effective doses using Monte Carlo technique for the three phantoms with a program for a personal computer. As benchmark studies to back up the results by Monte Carlo technique, we measured the organ doses directly on the small phantom using radiophotoluminescent glass dosimeters. The DAP value increased as the phantom size increased. The organ doses and the effective doses during the 3D imaging increased as the phantom size increased. The effective doses for the small phantom by Monte Carlo technique were 1.9, 2.2, and 2.1 mSv for the Allura Xper FD20/10, INNOVA 4100, and AXIOM Artis dTA, respectively, while those by direct measurement were 1.6, 2.0, and 2.6 mSv. The effective doses to DAP ratios by Monte Carlo technique were 0.37-0.45, 0.26-0.32, and 0.13-0.15 (mSv Gy{sup -1}cm{sup -2}) for the Allura Xper FD20/10, INNOVA 4100, and AXIOM Artis dTA, respectively. In conclusion, the effective doses during 3D imaging and the dose-to-DAP ratios differ among angiographic units, and the effective dose can be estimated using a proper conversion factor for each angiographic unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Control system for the Spallation Neutron Source H{sup -} source test facility Allison scanner

Spallation Neutron Source is currently in progress of a multiyear plan to ramp ion beam power to the initial design power of 1.4 MW. Key to reaching this goal is understanding and improving the operation of the H{sup -} ion source. An Allison scanner was installed on the ion source in the test facility to support this improvement. This paper will discuss the hardware and the software control system of the installed Allison scanner. The hardware for the system consists of several parts. The heart of the system is the scanner head, complete with associated bias plates, slits, and signal detector. There are two analog controlled high voltage power supplies to bias the plates in the head, and a motor with associated controller to position the head in the beam. A multifunction data acquisition card reads the signals from the signal detector, as well as supplies the analog voltage control for the power supplies. To synchronize data acquisition with the source, the same timing signal that is used to trigger the source itself is used to trigger data acquisition. Finally, there is an industrial personal computer to control the rest of the hardware. Control software was developed using National Instruments LABVIEW, and consists of two parts: a data acquisition program to control the hardware and a stand alone application for offline user data analysis.

43 PARTICLE ACCELERATORS↗

EVALUATING THE SENSITIVITY OF RADIONUCLIDE DETECTORS FOR CONDUCTING A MARITIME ON-BOARD SEARCH USING MONTE CARLO SIMULATION IMPLEMENTED IN AVERT

The sensitivity of two specific types of radionuclide detectors for conducting an on-board search in the maritime environment was evaluated using Monte Carlo simulation implemented in AVERT{reg_sign}. AVERT{reg_sign}, short for the Automated Vulnerability Evaluation for Risk of Terrorism, is personal computer based vulnerability assessment software developed by the ARES Corporation. The sensitivity of two specific types of radionuclide detectors for conducting an on-board search in the maritime environment was evaluated using Monte Carlo simulation. The detectors, a RadPack and also a Personal Radiation Detector (PRD), were chosen from the class of Human Portable Radiation Detection Systems (HPRDS). Human Portable Radiation Detection Systems (HPRDS) serve multiple purposes. In the maritime environment, there is a need to detect, localize, characterize, and identify radiological/nuclear (RN) material or weapons. The RadPack is a commercially available broad-area search device used for gamma and also for neutron detection. The PRD is chiefly used as a personal radiation protection device. It is also used to detect contraband radionuclides and to localize radionuclide sources. Neither device has the capacity to characterize or identify radionuclides. The principal aim of this study was to investigate the sensitivity of both the RadPack and the PRD while being used under controlled conditions in a simulated maritime environment for detecting hidden RN contraband. The detection distance varies by the source strength and the shielding present. The characterization parameters of the source are not indicated in this report so the results summarized are relative. The Monte Carlo simulation results indicate the probability of detection of the RN source at certain distances from the detector which is a function of transverse speed and instrument sensitivity for the specified RN source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design and development of a portable gamma radiation monitor

A portable gamma radiation monitor has been designed and developed. The monitor can be used effectively in the dose range from 0.07 to 500 mGy/h due to gamma rays of energy greater than 65 keV. The monitor overestimated radiation doses and the uncertainty in the measured dose rate has been found to be {<=}30%. The response of the monitor can be considered isotropic within an acceptable error of {+-}30%. Provision has also been added to use the monitor as an installed radiation monitor. In installed mode, it can be operated from a remote location up to 1 km and the timing history can be stored on a personal computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Framework for Analysis and Visualization of Simulation Data (VizAly)

As supercomputing resources increase, cosmological scientists are able to run more detailed and larger simulations generating massive amounts of data. Analyzing these simulations with an available open-source toolkit is important for collaborative Department of Energy scientific discovery across labs, universities, and other partners. Developed software as a part of this collection include: comparing data with other existing simulations, verifying and validating results with observation databases, new halo finder algorithms, and using analytical tools to get insights into the physics of the cosmological universe. The goal of this software project is to provide a set of open-source libraries, tools, and packages for large-scale cosmology that allows scientists to visualize, analyze, and compare large-scale simulation and observational data sets. Developed software will provide a variety of methods for processing, visualization, and analysis of astronomical observation and cosmological simulation data. These tools are intended for deployment on multiple scientific computing platforms, including but not limited to personal computers, cloud computing, experimental sites (telescopes) and high performance supercomputers.

Wendelberger, Joanne↗

Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner

Purpose: The aim of this study was to evaluate radiation dose to patients undergoing computed tomography coronary angiography (CTCA) for prospectively gated axial (PGA) technique and retrospectively gated helical (RGH) technique. Methods: Radiation doses were measured for a 320-detector row CT scanner (Toshiba Aquilion ONE) using small sized silicon-photodiode dosimeters, which were implanted at various tissue and organ positions within an anthropomorphic phantom for a standard Japanese adult male. Output signals from photodiode dosimeters were read out on a personal computer, from which organ and effective doses were computed according to guidelines published in the International Commission on Radiological Protection Publication 103. Results: Organs that received high doses were breast, followed by lung, esophagus, and liver. Breast doses obtained with PGA technique and a phase window width of 16% at a simulated heart rate of 60 beats per minute were 13 mGy compared to 53 mGy with RGH technique using electrocardiographically dependent dose modulation at the same phase window width as that in PGA technique. Effective doses obtained in this case were 4.7 and 20 mSv for the PGA and RGH techniques, respectively. Conversion factors of dose length product to the effective dose in PGA and RGH were 0.022 and 0.025 mSv mGy{sup -1} cm{sup -1} with a scan length of 140 mm. Conclusions: CTCA performed with PGA technique provided a substantial effective dose reduction, i.e., 70%-76%, compared to RGH technique using the dose modulation at the same phase windows as those in PGA technique. Though radiation doses in CTCA with RGH technique were the same level as, or some higher than, those in conventional coronary angiography (CCA), the use of PGA technique reduced organ and effective doses to levels less than CCA except for breast dose.

60 APPLIED LIFE SCIENCES↗

Effect of Bladder Distension on Dose Distribution of Intracavitary Brachytherapy for Cervical Cancer: Three-Dimensional Computed Tomography Plan Evaluation

Purpose: To quantify the effect of bladder volume on the dose distribution during intracavitary brachytherapy for cervical cancer. Methods and Patients: The study was performed on 10 women with cervical cancer who underwent brachytherapy treatment. After insertion of the brachytherapy applicator, the patients were transferred to the computed tomography unit. Two sets of computed tomography slices were taken, including the pelvis, one with an empty bladder and one after the bladder was filled with saline. The target and critical organs were delineated by the radiation oncologist and checked by the expert radiologist. The radiotherapy plan was run on the Plato planning system, version 14.1, to determine the dose distributions, dose-volume histograms, and maximal dose points. The doses and organ volumes were compared with the Wilcoxon signed ranks test on a personal computer using the Statistical Package for Social Sciences, version 11.0, statistical program. Results: No significant difference regarding the dose distribution and target volumes between an empty or full bladder was observed. Bladder fullness significantly affected the dose to the small intestine, rectum, and bladder. The median of maximal doses to the small intestine was significantly greater with an empty bladder (493 vs. 284 cGy). Although dosimetry revealed lower doses for larger volumes of bladder, the median maximal dose to the bladder was significantly greater with a full bladder (993 vs. 925 cGy). The rectal doses were also affected by bladder distension. The median maximal dose was significantly lower in the distended bladder (481vs. 628 cGy). Conclusions: Bladder fullness changed the dose distributions to the bladder, rectum, and small intestine. The clinical importance of these changes is not known and an increase in the use of three-dimensional brachytherapy planning will highlight the answer to this question.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pairwise alignment for very long nucleic acid sequences

Highlights: • The PAAVLS algorithm can be employed for alignment of very long sequences. • The PAAVLS algorithm largely reduces memory demand as the Smith–Waterman algorithm. • The running times of the PAAVLS and Smith–Waterman algorithms are comparable. Sequence alignment is one of the fundamental problems in computational biology and has numerous applications. The Smith–Waterman algorithm generates optimal local alignment for pairwise alignment task and has become a standard algorithm in its field. However, the current version of the Smith–Waterman algorithm demands a significant amount of memory and is not suitable for alignment of very long sequences. On the hand, the recent DNA sequencing technologies have produced vast amounts of biological sequences. Some nucleic acid sequences are very long and cannot employ the Smith–Waterman algorithm. To this end, this study proposes the PAAVLS algorithm that follows the dynamic programming technique employed by the Smith–Waterman algorithm and largely reduces the demand of memory. The proposed PAAVLS algorithm can be employed for alignment of very long sequences, i.e., sequences contain more than 100,000,000 nucleotides, on a personal computer. Additionally, the running time of the proposed PAAVLS algorithm is comparable with the running time of the standard Smith–Waterman algorithm.

60 APPLIED LIFE SCIENCES↗

Developments of fast emittance monitors for ion sources at RCNP

Recently, several developments of low energy beam transport line and its beam diagnostic systems have been performed to improve the injection efficiency of ion beam to azimuthally varying field cyclotron at Research Center for Nuclear Physics, Osaka University. One of those is the fast emittance monitor which can measure within several seconds for the efficient beam development and a Pepper-Pot Emittance Monitor (PPEM) has been developed. The PPEM consists of pepper-pot mask, multichannel plate, fluorescent screen, mirror, and CCD camera. The CCD image is taken via IEEE1394b to a personal computer and analyzed immediately and frequently, and then real time measurement with about 2 Hz has been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical Industry Corrosion Management: A Comprehensive Information System (ASSET 2). Final Report

The research sponsored by this project has greatly expanded the ASSET corrosion prediction software system to produce a world-class technology to assess and predict engineering corrosion of metals and alloys corroding by exposure to hot gases. The effort included corrosion data compilation from numerous industrial sources and data generation at Shell Oak Ridge National Laboratory and several other companies for selected conditions. These data were organized into groupings representing various combinations of commercially available alloys and corrosion by various mechanisms after acceptance via a critical screening process to ensure the data were for alloys and conditions, which were adequately well defined, and of sufficient repeatability. ASSET is the largest and most capable, publicly-available technology in the field of corrosion assessment and prediction for alloys corroding by high temperature processes in chemical plants, hydrogen production, energy conversion processes, petroleum refining, power generation, fuels production and pulp/paper processes. The problems addressed by ASSET are: determination of the likely dominant corrosion mechanism based upon information available to the chemical engineers designing and/or operating various processes and prediction of engineering metal losses and lifetimes of commercial alloys used to build structural components. These assessments consider exposure conditions (metal temperatures, gas compositions and pressures), alloy compositions and exposure times. Results of the assessments are determination of the likely dominant corrosion mechanism and prediction of the loss of metal/alloy thickness as a function of time, temperature, gas composition and gas pressure. The uses of these corrosion mechanism assessments and metal loss predictions are that the degradation of processing equipment can be managed for the first time in a way which supports efforts to reduce energy consumption, ensure structural integrity of equipment with the goals to avoid premature failure, to quantitatively manage corrosion over the entire life of high temperature process equipment, to select alloys for equipment and to assist in equipment maintenance programs. ASSET software operates on typical Windows-based (Trademark of Microsoft Corporation) personal computers using operating systems such as Windows 2000, Windows NT and Vista. The software is user friendly and contains the background information needed to make productive use of the software in various help-screens in the ASSET software. A graduate from a university-level curriculum producing a B.S. in mechanical/chemical/materials science/engineering, chemistry or physics typically possesses the background required to make appropriate use of ASSET technology. A training/orientation workshop, which requires about 3 hours of class time was developed and has been provided multiple times to various user groups of ASSET technology. Approximately 100 persons have been trained in use of the technology. ASSET technology is available to about 65 companies representing industries in petroleum/gas production and processing, metals/alloys production, power generation, and equipment design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗