Search NASA⌕ Search

SEARCH · Search NASA

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Exploring inflammation‐related protein expression and its relationship with TSPO PET in Alzheimer's disease

Abstract INTRODUCTION To understand the role of neuroinflammation in Alzheimer's disease (AD), we characterized immune‐related proteins in central and peripheral biofluids. METHODS Selection of participants from the Translational Biomarker of Aging and Dementia (TRIAD) cohort with available translocator protein (TSPO) positron emission tomography (PET), cerebrospinal fluid (CSF) (n = 97), and plasma (n = 165). Biofluid samples analyzed with Olink technology (368 inflammation proteins). RESULTS Elevated proteins levels in CSF of TSPO‐positive individuals were identified. Functional enrichment analysis of CSF proteins revealed processes implicated in AD (MAPK, ERK cascades, cytokine, and leukocyte signaling). Selected candidates (CXCL1 and TNFRSF11B) showed high correlation with each other in CSF and with TSPO PET signal, but weaker associations with amyloid and tau PET. No significantly changed proteins in plasma between TSPO groups were found. DISCUSSION This explorative study identified two potential targets in CSF showing correlations with TSPO, amyloid and tau PET, suggesting a direct link between neuroinflammation, expression of these proteins and their potential implication in AD. Highlights Several proteins are elevated in CSF of TSPO PET‐positive individuals, linking them to neuroinflammation. Elevated CSF proteins were enriched in pathways such as MAPK, ERK, and cytokine signaling, linking them to the AD pathophysiology. Candidate proteins (CXCL1 and TNFRSF11B) correlated strongly with TSPO PET, particularly in brain regions known to be affected in AD. Although none of the plasma proteins remained significant after multiple comparisons correction when comparing their expression between TSPO groups, as done for CSF, candidate CSF proteins were found to correlate with plasmatic proteins, highlighting the complexity of the immune system.

Neurosciences & Neurology↗

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Multilevel Analysis of Electrochemically Mediated Methanolysis of Poly(ethylene terephthalate) (PET)

Here, this study presents a multilevel analysis of electrochemically mediated methanolysis as a promising method for reducing the environmental impacts of plastic recycling, with a focus on depolymerizing poly(ethylene terephthalate) (PET) into dimethyl terephthalate (DMT). Instead of conventional chemical PET depolymerization, this electrochemical approach provides distinct technical advantages in process control and efficiency. At the process level, key operational parameters, including applied current and reaction time, were systematically investigated to optimize PET conversion and DMT selectivity. The electrochemical approach was directly compared to equivalent chemical methanolysis systems and demonstrated superior performance in terms of PET conversion and DMT selectivity. Building on these findings, a technoeconomic assessment identified the current economic bottlenecks and revealed that improvements in process design, DMT selectivity, PET conversion, and energy efficiency are key to reducing the overall process cost and enabling future implementation. While further optimization is required for market competitiveness, these results establish a performance baseline for the electrochemically mediated PET methanolysis process and underscore the importance of combining process-level innovation with systems-level evaluation in the development of sustainable recycling technologies.

chemical recycling↗

Waste PET Chemical Processing to Terephthalic Amides and Their Effect on Asphalt Performance

The large amount of waste generated from polyethylene terephthalate (PET) packaging materials that have reached the end of life is creating a waste management issue that cannot be handled by mechanical recycling alone. Thus, it is imperative that alternate routes to recover and reuse these materials be pursued. A chemical recycling approach of mixed PET was demonstrated here that provides a mechanism by which PET waste can be efficiently recovered and repurposed to value-added products. The approach utilizes aminolysis of PET with a variety of amine nucleophiles, generating a small library of phthalimides with unique structures. In order to probe the high value of these products, the phthalimides were added to road-grade asphalt binder at 5 wt% and the resulting composite was evaluated. Specifically, rutting and fatigue characteristics as well as thermomechanical and creep performance were characterized and found to be improved by the inclusion of these additives by as much as 18%. In this work, additives made from deconstructed PET wastes were shown to improve the performance properties of asphalt at a variety of environmental conditions. These improvements would reduce the cost of road maintenance and provide a high-value market for waste PET. It is important to note that the asphalt binder utilized in this work was a commercial product already optimized for road conditions, not the raw bitumen; perhaps higher performance metrics could be obtained with virgin bitumen.

Recycling, Asphalt↗

Solubilization of PET in binary mixtures of HFIP and DCM

The dissolution of polyethylene terephthalate (PET) is a critical step for a solvent-based process, yet it typically requires highly corrosive or toxic solvents. Here, we investigate the solubilization and conformational behavior of PET in binary mixtures of hexafluoro-2-propanol (HFIP) and dichloromethane (DCM) as a strategy to reduce HFIP usage while maintaining effective dissolution. Small-angle neutron scattering (SANS) measurements reveal that PET remains molecularly dissolved in HFIP/DCM mixtures up to 50 vol% DCM. Analysis of PET chain conformations shows a transition from Gaussian behavior at low HFIP fractions to more swollen chains at intermediate compositions, accompanied by a counter-intuitive minimum in the radius of gyration at 50% HFIP. Complementary SANS measurements of the binary solvents demonstrate that compositional heterogeneity is maximized at this same solvent composition, suggesting a direct coupling between solvent microstructure and polymer dimensions. Molecular dynamics simulations corroborate the experimental findings, revealing solvent domain formation, preferential solvation of PET by HFIP, and a “caging” effect arising from solvent heterogeneity that leads to polymer coil compaction. Together, these results provide molecular-level insight into polymer behavior in mixed solvent systems and establish HFIP/DCM mixtures as a promising, more sustainable solvent platform for the PET post-process.

Arifuzzaman, Arif [ORNL]↗

Small animal PET: a review of what we have done and where we are going

Abstract Small animal research is an essential tool in studying both pharmaceutical biodistribution and disease progression over time. Furthermore, through the rapid development of in vivo imaging technology over the last few decades, small animal imaging (also referred to as preclinical imaging) has become a mainstay for all fields of biologic research and a center point for most preclinical cancer research. Preclinical imaging modalities include optical, MRI and MRS, microCT, small animal PET, ultrasound, and photoacoustic, each with their individual strengths. The strong points of small animal PET are its translatability to the clinic; its quantitative imaging capabilities; its whole-body imaging ability to dynamically trace functional/biochemical processes; its ability to provide useful images with only nano- to pico- molar concentrations of administered compounds; and its ability to study animals serially over time. This review paper gives an overview of the development and evolution of small animal PET imaging. It provides an overview of detector designs; system configurations; multimodality PET imaging systems; image reconstruction and analysis tools; and an overview of research and commercially available small animal PET systems. It concludes with a look toward developing technologies/methodologies that will further enhance the impact of small animal PET imaging on medical research in the future.

Engineering↗

Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent testing of meteorite and Apollo samples on micro-XRF instruments has shown that they can easily detect small zircons and phosphates (approx. 10 m), distinguish different clast lithologies within breccias, and identify different lithologies within small rock fragments (2-4 mm soil Apollo soil fragments).

Zeigler, R. A.↗

Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

Zeigler, Ryan A.↗

The Bacteroidetes Aequorivita sp. and Kaistella jeonii Produce Promiscuous Esterases With PET-Hydrolyzing Activity

Certain members of the Actinobacteria and Proteobacteria are known to degrade polyethylene terephthalate (PET). Here, we describe the first functional PET-active enzymes from the Bacteroidetes phylum. Using a PETase-specific Hidden-Markov-Model- (HMM-) based search algorithm, we identified several PETase candidates from Flavobacteriaceae and Porphyromonadaceae. Among them, two promiscuous and cold-active esterases derived from Aequorivita sp. (PET27) and Kaistella jeonii (PET30) showed depolymerizing activity on polycaprolactone (PCL), amorphous PET foil and on the polyester polyurethane Impranil ® DLN. PET27 is a 37.8 kDa enzyme that released an average of 174.4 nmol terephthalic acid (TPA) after 120 h at 30°C from a 7 mg PET foil platelet in a 200 μl reaction volume, 38-times more than PET30 (37.4 kDa) released under the same conditions. The crystal structure of PET30 without its C-terminal Por-domain (PET30ΔPorC) was solved at 2.1 Å and displays high structural similarity to the Is PETase. PET30 shows a Phe-Met-Tyr substrate binding motif, which seems to be a unique feature, as Is PETase, LCC and PET2 all contain Tyr-Met-Trp binding residues, while PET27 possesses a Phe-Met-Trp motif that is identical to Cut190. Microscopic analyses showed that K. jeonii cells are indeed able to bind on and colonize PET surfaces after a few days of incubation. Homologs of PET27 and PET30 were detected in metagenomes, predominantly aquatic habitats, encompassing a wide range of different global climate zones and suggesting a hitherto unknown influence of this bacterial phylum on man-made polymer degradation.

59 BASIC BIOLOGICAL SCIENCES↗

Systems Analysis and Optimization of Circular PET Packaging Supply Chains in the United States: Environmental and Socioeconomic Impacts

Many actions are underway at global, national, and local levels to address the plastic waste problem and transition toward a circular economy of plastics. Studies evaluating environmental and socioeconomic impacts of such a transition are lacking. Here, the purpose of this study is to conduct a national systems analysis of polyethylene terephthalate (PET) packaging supply chains in the United States. Material flow data was combined with environmental and socioeconomic indicators to evaluate and compare the sustainability of the linear PET packaging supply chain, current (2019) supply chain, and possible future circular supply chain options in the United States. Environmentally optimal circular US PET packaging material flows showed 31% and 38% savings of GHG emissions and energy demand, respectively, with a circularity of 77% when compared with a linear supply chain. Additionally, the environmentally optimal system showed higher employment (29%) and wages (31%) than a linear system, but with a 5% decrease in revenue generation. A socioeconomically optimal circular PET supply chain showed increased employment (by 52%), wages (by 67%), and revenues (by 1%), with a circularity of 59% when compared with the linear system. However, it showed 14% higher GHG emissions than a linear system, indicating a trade-off between environmentally and socioeconomically optimal circular PET packaging systems. Overall, linear-to-circular material flow transition may not necessarily lead to increased revenues and decreased environmental impacts of the entire system, but it does benefit society due to increased employment and wages. Future systems analysis work should focus on improving data quality for environmental and socioeconomic dimensions.

PET↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks↗

False positive PSMA PET for tumor remnants in the irradiated prostate and other interpretation pitfalls in a prospective multi-center trial

Readers need to be informed about potential pitfalls of [ 68 Ga]Ga-PSMA-11 PET interpretation. Here we report [ 68 Ga]Ga-PSMA-11 PET findings discordant with the histopathology/composite reference standard in a recently published prospective trial on 635 patients with biochemically recurrent prostate cancer. Consensus reads were false positive in 20 regions of 17/217 (8%) patients with lesion validation. Majority of the false positive interpretations (13 of 20, 65%) occurred in the context of suspected prostate (bed) relapse (T) after radiotherapy ( n = 11); other false positive findings were noted for prostate bed post prostatectomy (T, n = 2), pelvic nodes (N, n = 2), or extra pelvic lesions (M, n = 5). Major sources of false positive findings were PSMA-expressing residual adenocarcinoma with marked post-radiotherapy treatment effect. False negative interpretation occurred in 8 regions of 6/79 (8%) patients with histopathology validation, including prostate (bed) ( n = 5), pelvic nodes ( n = 1), and extra pelvic lesions ( n = 2). Lesions were missed mostly due to small metastases or adjacent bladder/urine uptake.[ 68 Ga]Ga-PSMA-11 PET at biochemical recurrence resulted in less than 10% false positive interpretations. Post-radiotherapy prostate uptake was a major source of [ 68 Ga]Ga-PSMA-11 PET false positivity. In few cases, PET correctly detects residual PSMA expression post-radiotherapy, originating however from treated, benign tissue or potentially indolent tumor remnants.

Radiology, Nuclear Medicine & Medical Imaging↗

Controlling PET oligomers vs monomers via microwave-induced heating and swelling

The production of polyethylene terephthalate (PET) bottles and fibers, and their subsequent mismanagement, have created an urgent need to develop strategies to handle the resulting waste. Here, in this work, glycolysis of PET using manganese oxide catalysts under microwave-assisted heating is demonstrated to form oligomers and the monomer bis(2-hydroxyethyl) terephthalate (BHET) at moderate conditions. Higher surface area catalysts achieve faster overall rates of depolymerization to the monomer. Oligomers form homogeneously and depolymerize to monomers over manganese oxide. The polymer-to-solvent ratio and reaction temperature affect the overall oligomer yield. The swelling of PET, caused by the diffusion of ethylene glycol into the polymer matrix, causes the dissolution of the PET to form oligomers. Oligomers are characterized and show similar physical properties to the starting PET despite having 1/20th of the molecular weight.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tau PET positivity in individuals with and without cognitive impairment varies with age, amyloid-β status, APOE genotype and sex

Abstract Tau positron emission tomography (PET) imaging allows in vivo detection of tau proteinopathy in Alzheimer’s disease, which is associated with neurodegeneration and cognitive decline. Understanding how demographic, clinical and genetic factors relate to tau PET positivity will facilitate its use for clinical practice and research. Here we conducted an analysis of 42 cohorts worldwide (N = 12,048), including 7,394 cognitively unimpaired (CU) participants, 2,177 participants with mild cognitive impairment (MCI) and 2,477 participants with dementia. We found that from age 60 years to 80 years, tau PET positivity in a temporal composite region increased from 1.1% to 4.4% among CU amyloid-β (Aβ)-negative participants and from 17.4% to 22.2% among CU Aβ-positive participants. Across the same age span, tau PET positivity decreased from 68.0% to 52.9% in participants with MCI and from 91.5% to 74.6% in participants with dementia. Age, Aβ status,APOEε4 carriership and female sex were all associated with a higher prevalence of tau PET positivity across groups.APOEε4 carriership in CU individuals lowered the age at onset of both Aβ positivity and tau positivity by decades. Finally, we replicated these associations in an independent autopsy dataset (N = 5,072 from 3 cohorts).

Neurosciences & Neurology↗

Catalytic co-pyrolysis of LDPE and PET with HZSM-5, H-beta, and HY: experiments and kinetic modelling

In this study, the catalytic pyrolysis of low-density polyethylene (LDPE), polyethylene terephthalate (PET) and their mixture (1 : 1 wt/wt) with three zeolite catalysts (HZSM-5, H-beta, HY) was investigated using a thermogravimetric analyzer (TGA) and a Pyroprobe® micro-reactor coupled to a gas chromatograph mass spectrometer (Py-GC/MS). The TGA results demonstrated that during pyrolysis at 10 °C min –1 , on average, zeolite catalysts decreased the maximum decomposition temperature by 149 °C for LDPE while only decreasing by 8 °C for PET. The derivative thermogravimetric (DTG) curve evidenced interactions when the two polymers were catalytically co-pyrolyzed for all the three catalysts. A lumped nth order reaction scheme was able to accurately model both non-catalytic and catalytic pyrolysis and co-pyrolysis by using the least squares fitting approach for determining the kinetic parameters. The kinetic model was able to model well the interaction effects observed during catalytic co-pyrolysis of LDPE and PET with HZSM-5, H-beta, and HY (Fit% Wt% > 96%, Fit% DTG > 94%). Py-GC/MS experiments for the catalytic fast pyrolysis of LDPE revealed that HZSM-5 resulted in the highest selectivity to aromatic hydrocarbons (31.6%) and HY resulted in the highest selectivity to gasoline range C 5 –C 10 paraffins and olefins (40.9%). Catalytic fast pyrolysis of PET showed high selectivity to benzene for all the catalysts (>43%) and that HZSM-5 resulted in the highest selectivity to polyaromatic hydrocarbons (24.7%). Finally, the catalytic fast co-pyrolysis of LDPE and PET revealed interaction effects for all the three catalysts evidenced by a positive synergy% for alkylated benzenes (3–142%) and polyaromatics (105–187%) with a concomitant negative synergy% for benzene (24–36%) and C 5 –C 10 paraffins and olefins (27–53%).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PET - A proton/electron telescope for studies of magnetospheric, solar, and galactic particles

The Proton/Electron Telescope (PET) on SAMPEX is designed to provide measurements of energetic electrons and light nuclei from solar, galactic, and magnetospheric sources. PET is an all solid-state system that will measure the differential energy spectra of electrons from about 1 to about 30 MeV and H and He nuclei from about 20 to about 300 MeV/nuc, with isotope resolution of H and He extending from about 20 to about 80 MeV/nuc. As SAMPEX scans all local times and geomagnetic cutoffs over the course of its near-polar orbit, PET will characterize precipitating relativistic electron events during periods of declining solar activity, and it will examine whether the production rate of odd nitrogen and hydrogen molecules in the middle atmosphere by precipitating electrons is sufficient to affect O3 depletion. In addition, PET will complement studies of the elemental and isotopic composition of energetic heavy (Z greater than 2) nuclei on SAMPEX by providing measurements of H, He, and electrons. Finally, PET has limited capability to identify energetic positrons from potential natural and man-made sources.

Cook, Walter R.↗

Production and radiochemistry of the in vivo PET generator 140 Nd/ 140 Pr as an imaging surrogate for F-block therapeutic radionuclides

Theranostics, a combined approach of diagnostics and therapeutics, often employs F-block therapeutic radionuclides including 225 Ac, 177 Lu, and 161 Tb. While there is a lack of F-block PET imaging radionuclides, the in vivo PET generator pair 140 Nd/ 140 Pr can act as a theranostic imaging counterpart to the F-block therapeutic radionuclides. In this study, we explored the production and separation of high purity 140 Nd via the 141 Pr(p,2n) 140 Nd reaction route. Monoisotopic 141 Pr targets irradiated with 20 MeV protons for 10 min with 10 µA beam current yielded 21.45 ± 0.82 MBq (580 ± 22 µCi) of 140 Nd. A two-step separation method was developed for the purification of 140 Nd from the 141 Pr target material. Recoveries of 27.4 ± 2.1% 140Nd were obtained upon separation with < 20 ppb of 141 Pr target material in the final product. Radiolabeling of Macropa and DOTA chelators with 140 Nd resulted in [ 140 Nd]Nd-Macropa with a molar activity of 74.0 MBq/µmol (2.0 mCi/µmol) and [ 140 Nd]Nd-DOTA with a molar activity of 70.3 MBq/µmol (1.9 mCi/µmol). An imaging study with a phantom indicated the PET spatial resolution of 140 Nd/ 140 Pr was distinguishable down to 2.4 mm. This study sets the stage for the 140 Nd/ 140 Pr in vivo PET generator to be explored in radiopharmaceutical applications.

F-block↗