A Fast Load Control System Based on Mobile Distribution-Level Phasor Measurement Unit

The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of our work is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel Mobile Distribution-level Phasor Measurement Unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the Rate Of Change Of Frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also examined. Finally, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secure and Cost-Effective Micro Phasor Measurement Unit (PMU)-Like Metering for Behind-the-Meter (BTM) Solar Systems Using Blockchain-Assisted Smart Inverters: Preprint

Recently, there is increasing interest in using behind-the-meter (BTM) solar systems for grid services. However, providing visibility and operational situational awareness of BTM solar systems mainly operated by small-scale solar inverters is challenging due to the requirement of relatively expansive networked observation tools (e.g., micro phasor measurement units (uPMUs)) and consequent cybersecurity threats through networks. This paper presents a secure, cost-effective, uPMUs-like metering method using a blockchain-assisted smart (BAS) inverters for a BTM solar system. The proposed BAS inverter consisting of an internet-of-things device as a node of a local blockchain network enables the secure provision of inverter measurement data for grid services. The BAS inverter sends the encrypted local measurement data with a timestamp to a local blockchain miner. Once the blockchain miner generates a tamper-resistant metering ledger including the measurements, it is used to assess the situational awareness of the BTM solar system. The concept of the proposed metering using the BAS inverters is validated by experimental studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Offline Power Systems Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

This report provides a brief overview of several offline (non-real-time) applications facilitated by high-resolution time-synchronized measurements recorded by phasor measurement units (PMUs). The high reporting rate and time-synchronization of PMU records provide a detailed view of power system dynamics, enabling electric utilities to obtain a better understanding of their systems. In this report, the following applications have been reviewed: Power plant model validation, System model validation, Ringdown oscillation analysis, Frequency response analysis, Postmortem analysis of disturbance events Along with a brief technical background of the applications above, applicable North American Electric Reliability Corporation (NERC) standards have been discussed, and examples of implementation in North American organizations have been provided. Implementing several of the discussed applications may need a preliminary stage of data gathering from multiple entities, and several frameworks and process flows have been formulated by organizations around the world for this purpose. However, the data-gathering stage has not been considered in the scope of the present report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR↗

Calibration of Reduced Dynamic Models of Power Systems using Phasor Measurement Unit (PMU) Data

Accuracy of a power system dynamic model is essential to the secure and efficient operation of the system. Lower confidence on model accuracy usually leads to conservative operation and lowers asset usage. To improve model accuracy, identification algorithms have been developed to calibrate parameters of individual components using measurement data from staged tests. To facilitate online dynamic studies for large power system interconnections, this paper proposes a model reduction and calibration approach using phasor measurement unit (PMU) data. First, a model reduction method is used to reduce the number of dynamic components. Then, a calibration algorithm is developed to estimate parameters of the reduced model. This approach will help to maintain an accurate dynamic model suitable for online dynamic studies. The performance of the proposed method is verified through simulation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Resolution Fault Localization Using Phasor Measurement Units with Community Detection

A significant portion of the literature on fault localization assumes (more or less explicitly) that there are sufficient reliable measurements to guarantee that the system is observable. While several heuristics exist to break the observability barrier, they mostly rely on recognizing spatio-temporal patterns, without giving insights on how the performance are tied with the system features and the sensor deployment. In this paper, we try to fill this gap and investigate the limitations and performance limits of fault localization using Phasor Measurement Units (PMUs), in the low measurements regime, i.e., when the system is unobservable with the measurements available. Our main contribution is to show how one can leverage the scarce measurements to localize different type of distribution line faults (three-phase, single-phase to ground,..) at the level of sub-graph, rather than with the resolution of a line. Here, we show that the resolution we obtain is strongly tied with the graph clustering notion in network science.

Community Detection↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mobile electric field sensor based phasor measurement unit for monitoring an electric power grid

A system may include an electric field sensor, an analog to digital converter, and an estimator. The electric field sensor may measure electric fields of electric power grid. The analog to digital converter may generate digital output based upon measurements from the electric field sensor. The estimator may estimate phasor data of the electric power grid based upon the digital output.

Liu, Yilu↗

A Bayesian Approach to Real-Time Dynamic Parameter Estimation Using Phasor Measurement Unit Measurement

Here, we develop a polynomial-chaos-expansion (PCE)-based approach for decentralized dynamic parameter estimation through Bayesian inference. Using this approach, the non-Gaussian distribution of the inverted parameters is obtained. More specifically, we first represent the decentralized generator model with the PCE-based surrogate. This surrogate allows us to efficiently evaluate the time-consuming dynamic solver at parameter values through Metropolis-Hastings (M-H)-based Markov chain Monte Carlo (MCMC). Then, we propose a two-stage hybrid Markov chain Monte Carlo (MCMC) to recover a posteriori distribution of the decentralized generator model parameters. In the first stage, we use the gradient-enhanced Langevin MCMC algorithm to characterize an intermediate posterior parameter distribution. This algorithm is computationally scalable to the high-dimensional parameter space. Based on the intermediate posterior distribution, during the second stage, we use the adaptive MCMC algorithm to fine-tune the strong correlations between the parameters. Finally, the fully recovered a posterior distribution is obtained in the end. The simulation results show that the proposed PCE-based hybrid MCMC algorithm can accurately and efficiently estimate the high-dimensional generator dynamic model parameters with full probabilistic distribution provided.

42 ENGINEERING↗

Online Monitoring Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

In this report, an overview of several online applications enabled by PMU measurements is provided. Besides a brief technical background for each application, the report also discusses control room displays and alarming methodologies used by North American organizations, and applicable standards set by the North American Electric Reliability Corporation (NERC). The five applications discussed herein are inertia monitoring, linear state estimation, voltage stability monitoring, small-signal stability monitoring, and forced oscillation monitoring.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local Power-Voltage Sensitivity and Thevenin Impedance Estimation from Phasor Measurements

This paper describes how to use voltage phasor measurements to produce a sensitivity matrix that describes how real and reactive power injections at a node on a distribution network affect the local voltage magnitude and angle. Rather than estimating the sensitivity directly, the voltage phasor measurements and power commands/measurements are used to estimate the unbalanced, three-phase Thevenin impedance. The Thevenin impedance estimation is conducted using recursive least squares on temporal difference measurements. The Thevenin impedance and voltage phasor measurement are then used to build the local power-voltage sensitivity matrix with the closed form expression for the Jacobian of the power flow manifold. Hardware-in-the-loop simulations with phasor measurement units providing real phasor measurements are used to evaluate the recursive temporal difference Thevenin impedance estimation and Thevenin-based power-voltage sensitivity methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SynchroPhasor Measurements: System Architecture and Performance Evaluation in Supporting Wide-Area Applications

The infrastructure of phasor measurements have evolved over the last two decades from isolated measurement units to networked measurement systems with footprints beyond individual utility companies. This is, to a great extent, a bottom-up self-evolving process except some local systems built by design. Given the number of phasor measurement units (PMUs) in the system is small (currently 70 each in western and eastern interconnections), current phasor network architecture works just fine. However, the architecture will become a bottleneck when large number of PMUs are installed (e.g. >1000~10000). The need for phasor architecture design has yet to be addressed. This paper reviews the current phasor networks and investigates future architectures, as related to the efforts undertaken by the North America SynchroPhasor Initiative (NASPI). Then it continues to present staged system tests to evaluate the performance of phasor networks, which is a common practice in the Western Electricity Coordinating Council (WECC) system. This is followed by field measurement evaluation and the implication of phasor quality issues on phasor applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronized Phasor Measurement Unit-based Central Controller for Normal and Contingent Operation of a High-Capacity HVDC Macrogrid for the Continental US

This paper presents a Synchronized Phasor Measurement Unit (PMU) based controller to support the coordination and operation of a high-capacity high-voltage direct current (HVDC) macrogrid transmission for the continental US. The proposed controller allows for optimal scheduling of each segment of the multi-terminal HVDC network under normal and contingent conditions, while considering minimum levels of frequency response requirements. The performance of the proposed controller is tested on a 100,222-bus representation of the US Eastern and Western interconnections. Results show that a centralized PMU-based controller improves the frequency nadir of the HVDC macrogrid under contingency conditions by 25.9%. Furthermore, the primary frequency response (PFR) of the HVDC macrogrid is increased by 33.4%. The performance of each interconnection under the largest credible contingency conditions is also discussed.

Mohan, Nihal↗

System and method for detecting false data injection in electrical substations

Unique systems, methods, techniques and apparatuses of a substation phasor data concentrator (ssPDC) is disclosed herein. One exemplary embodiment is a method for operating an electrical substation including a merging unit (MU), a phasor measurement unit (PMU), and a substation phasor data concentrator (ssPDC). The method includes receiving, with the MU and the PMU, input information corresponding to a set of electrical characteristics of the electrical substation; measuring, with the MU, the input information; measuring, with the PMU, the input information; a and estimating, with the ssPDC, electrical characteristics of the electrical substation using the received false measurement and the one of the MU measurement and the PMU measurement, determining in substantially real time the false measurement does not correspond to the set of electrical characteristics using the estimated electric characteristics, and replacing the false measurement with the received the one of the MU measurement and the PMU measurement.

Hong, Junho↗

Prony Ringdown GUI (CERTS Prony Ringdown, part of the DSI Tool Box)

The PNNL Prony Ringdown graphical user interface is one analysis tool included in the Dynamic System Identification toolbox (DSI Toolbox). The Dynamic System Identification toolbox is a MATLAB-based collection of tools for parsing and analyzing phasor measurement unit data, especially in regards to small signal stability. It includes tools to read the data, preprocess it, and perform small signal analysis. 5. Method of Solution: The Dynamic System Identification Toolbox (DSI Toolbox) is designed to provide a research environment for examining phasor measurement unit data and performing small signal stability analysis. The software uses a series of text-driven menus to help guide users and organize the toolbox features. Methods for reading in populate phasor measurement unit data are provided, with appropriate preprocessing options for small-signal-stability analysis. The toolbox includes the Prony Ringdown GUI and basic algorithms to estimate information on oscillatory modes of the system, such as modal frequency and damping ratio.

Tuffner, Francis↗

PMU Placement for Enhancing Dynamic Observability of a Power Grid

Power grids are operated in an increasingly complicated environment. However, operators lack effective and accurate tools for real-time monitoring and control of power systems. The U.S. Department of Energy, along with several utilities and system operators, is making a major $108 million investment in the Western Interconnection for phasor measurement unit (PMU) installation and phasor application development. This phasor measurement network opens up many opportunities for the estimation and prediction of power system states in real time, which enable operators to evaluate the system dynamic security in advance and allow them more time to respond to disturbances. Kalman filter based dynamic state estimation offers a solution suitable for this purpose. Our work indicates that the performance of Kalman filters in dynamic state estimation would degrade if PMU measurements cannot adequately capture the system dynamics. This paper develops a framework to identify how to place PMUs to improve dynamic observability of the power grid. Simulation results validate the concept, and the guidelines for PMU placement are derived.