Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOELECTRIC APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Effusive molecular beam-sampled Knudsen flow reactor coupled to vacuum ultraviolet single photon ionization mass spectrometry using an external free radical source

A new apparatus using vacuum ultraviolet single photon ionization mass spectrometry (VUV SPIMS) of an effusive molecular beam emanating from a Knudsen flow reactor is described. It was designed to study free radical-molecule kinetics over a significant temperature range (300–630 K). Its salient features are: (1) external free radical source, (2) counterpropagating molecular beam and diffuse VUV photon beam meeting in a crossed-beam ion source of a quadrupole mass spectrometer with perpendicular ion extraction, (3) analog detection of the photocurrent of the free radical molecular cation, and (4) possibility of detecting both free radicals and closed shell species in the same apparatus and under identical reaction conditions owing to the presence of photoelectrons generated by the photoelectric effect of the used VUV-photons. The measured thermal molecular beam-to-background ratio was 6.35 ± 0.39 for Ar and 10.86 ± 1.59 for i-C{sub 4}H{sub 10} at 300 K, a factor of 2.52 and 1.50 smaller, respectively, than predicted from basic gas-dynamic considerations. Operating parameters as well as the performance of key elements of the instrument are presented and discussed. Coupled to an external free radical source a steady-state specific exit flow of 1.6 × 10{sup 11} and 5.0 × 10{sup 11} molecule s{sup −1} cm{sup −3} of C{sub 2}H{sub 5}{sup •} (ethyl) and t-C{sub 4}H{sub 9}{sup •} (t-butyl) free radicals have been detected using VUV SPIMS at their molecular ion m/z 29 and 57, respectively, at 300 K.

2-METHYLPROPANE↗

Monitoring Surface Condition of Plasma Grid of a Negative Hydrogen Ion Source

Surface condition of a plasma grid in a negative hydrogen ion source is controlled so as to maximize the beam current under a discharge operation with introducing Cs into the ion source. Photoelectric current induced by laser beams incident on the plasma grid can produce a signal to monitor the surface condition, but the signal detection can be easily hindered by plasma noise. Reduction in size of a detection electrode embedded in the plasma grid can improve signal-to-noise ratio of the photoelectric current from the electrode. To evaluate the feasibility of monitoring surface condition of a plasma gird by utilizing photoelectric effect, a small experimental setup capable of determining quantum yields of a surface in a cesiated plasma environment is being assembled. Some preliminary test results of the apparatus utilizing oxide cathodes are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous quantum measurement of a light-matter system

Continuous measurements on correlated quantum systems, in addition to providing information on the state vector of the system in question, induce evolution in the unmeasured degrees of freedom conditioned on the measurement outcome. However, experimentally accessing these nontrivial regimes requires high-efficiency measurements over time scales much longer than the temporal resolution of the measurement apparatus. We report the observation of such a continuous conditioned evolution in the state of a light-collective atomic excitation system undergoing photoelectric measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent developments in density, temperature and momentum fluctuation measurement

Attention is drawn to recent advancements in the fluctuating line-reversal temperature measurement, the development of the two-dimensional drag-sensing probe into a three-dimensional drag-sensing probe, and the fluctuating density gradient cross beam Schlieren technique. An experimental apparatus is explained whereby the temperature fluctuation in a pulsating air-fuel ratio Bunsen burner is measured by means of sodium D-line reversal methods with a new photoelectric circuit to obtain both fluctuating and mean temperature data. The three-D drag probe is made possible by a newly invented differential and total magnetic sensing system that separates signals due to three orthogonal movements so that the vectorial momentum fluctuation can be measured. In the case of the Schlieren technique, the effect of anisotropic density gradients with respect to the angle between the polarization plane and the knife edge of a laser Schlieren system is studied.

Battle, T. M.↗

Ultraviolet sensing apparatus with mirror amplification

Systems, methods, and devices of the various embodiments may enable the detection and localization of power line corona discharges and/or electrical arcs by an unmanned aerial vehicle (UAV) including an ultraviolet (UV) sensor and a reflective parabolic dish. In various embodiments, the UV sensor may use the photoelectric effect to sense narrow-band UV photons in a Geiger-Mueller tube and circuit configuration. In various embodiments, the reflective parabolic dish may be fixed relative to the UV sensor and include a reflective concave surface. The reflective concave surface may be configured to reflect narrow-band UV photons toward the UV sensor.

Moore, Andrew J.↗

Precision limits of the twin-beam multiband URSULA

URSULA is a multiband astronomical photoelectric photometer which minimizes errors introduced by the presence of the atmosphere. It operates with two identical channels, one for the star to be measured and the other for a reference star. After a technical description of the present version of the apparatus, some measurements of stellar sources of different brightness, and in different atmospheric conditions are presented. These measurements, based on observations made with the 91 cm Cassegrain telescope of the Catania Astrophysical Observatory, are used to check the photometer accuracy and compare its performance with that of standard photometers.

Debiase, G. A.↗

Laboratory Measurements of Optical Properties of Micron Size Individual Dust Grains

A laboratory program is being developed at NASA Marshall Space Flight Center for experimental determination of the optical and physical properties individual dust grains in simulated astrophysical environments. The experimental setup is based on an electrodynamic balance that permits levitation of single 0.1 - 10 micron radii dust grains in a cavity evacuated to pressures of approx. 10(exp -6) torr. The experimental apparatus is equipped with observational ports for measurements in the UV, visible, and infrared spectral regions. A cryogenic facility for cooling the particles to temperature of approx. 10-50K is being installed. The current and the planned measurements include: dust charging processes, photoelectric emissions and yields with UV irradiation, radiation pressure measurements, infrared absorption and scattering properties, and condensation processes, involving the analogs of cosmic dust grains. Selected results based on photoemissions, radiation pressure, and other laboratory measurements will be presented.

Abbas, M. M.↗