Search NASA⌕ Search

SEARCH · Search NASA

Results for “PI control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Control systems of the large millimeter telescope

The paper presents the analysis results (in terms of settling time, bandwidth, and servo error in wind disturbances) of four control systems designed for the Large Millimeter Telescope (LMT). The first system, called PI’, consists of the proportional and integral (PI) controllers in the rate and position loops, and is widely used in the antenna and radiotelescope industry. The analysis shows that the PP control system performance is remarkably good when compared to similar control systems applied to typical antennas. This performance is achieved because the LMT structure is exceptionally rigid, however, it does not meet the stringent LMT pointing requirements. The second system, called PL, consists of the PI controller in the rate loop, and the Linear-Quadratic-Gaussian (LQG) controller in the position loop. This type of controller is implemented in the NASA Deep Space Network antennas, where pointing accuracy is twice that of PP control system. The third system, called LP, consists of the LQG controller in the rate loop, and the propositional-integral-derivative (PID) controller in the position loop. This type of loop has not been yet implemented at known antennas or radiotelescopes, but the analysis shows that its pointing accuracy is the ten times better than PP control system. The fourth system, called LL, consists of the LQG controller in both the rate loop, and the position loop. It is the best of the four, with accuracy 250 better than the PP system, thus is worth further investigations, to identify implementation challenges for the telescopes of high pointing requirements.

Souccar, Kainal↗

GammaCore: The Compton Observatory research environment

The Compton Observatory Science Support Center (COSSC) is developing a coherent analysis environment for the analysis of Compton and other gamma-ray astronomy data. This environment, GammaCore, allows the astronomer to access the data analysis systems developed at the Principal Investigator (PI) sites for the four Compton Observatory instruments. In addition users have access to standard astronomical tools such as IRAF, IDL, and XANADU. The user interface of GammaCore is the AGCL (AnswerGarden Command Language), developed at the AXAF Science Center. The parameter interface supported by the AGCL allows GammaCore to access all PI software systems in a uniform fashion. These systems are quite different, having been developed independently on heterogeneous systems without much concern for general portability. The data kibitzer concept, where a window running in a specific PI environment is controlled by the AGCL, has been used extensively. Users can choose to view what is going on in the native environment, to use the window to control PI software directly, or to ignore the PI systems entirely and to work only through the homogeneous AGCL interface. Software developed at the COSSC is also integrated within GammaCore. Extensive facilities for conversions of PI data formats to and from FITS have been developed. Access to the Compton data archive and catalogs will also be completely integrated with the GammaCore. Users can retrieve any publicly available Compton data. This paper examines the issues that have arisen in attempting to meld these widely diverse systems. The advantages and limitations of the parameter interface and the kibitzer are discussed along with issues of data portability, documentation, and the feasibility of multi-instrument analysis. Limited capabilities are now available within GammaCore with significant enhancements planned over the coming year. An implementation including all PI systems will be available within that time. Instructions on how to access GammaCore and how to get more information are given.

Mcglynn, T. A.↗

Model Predictive Control Study for an Electrified Turbofan Engine

A control sensitivity study is conducted for electrified aircraft propulsion concepts using a publicly available turbofan engine simulation. A Proportional-Integral (PI) controller serves as a baseline for comparison against an advanced Model Predictive Control (MPC) approach. MPC is used in the control scheme to allow for subsystem coordination of engine and electric power loads. The electrified turbofan engine includes electric machines to augment the amount of torque being applied to the spools of the engine during transient phases of operation. Power augmentation allows for energy to be stored or exhausted in a manner that increases the fuel efficiency of the engine, reducing aircraft emissions and noise. The study compares the fan speed, high pressure compressor stall margin, and low pressure compressor stall margin against the baseline PI control system, an MPC system without electric machines, and an MPC system with electric machines. The MPC system with electric machines is optimized using the sample time, control horizon and prediction horizon. The MPC design provided a stable damped response as desired and allowed operability margins to be maintained

Electrified Aircraft Propulsion↗

Model Predictive Control Strategies for Turbine Electrified Energy Management

The increasing electrification of aircraft propulsion systems is leading to new control architectures being developed to address integration between electric machines and gas-based turbine engines. For hybrid-electric propulsion systems, current conceptual architectures often couple electric machines with the shafts of gas turbine engines and introduce energy storage. Leveraging the electrical power system of hybridized engines, Turbine Electrified Energy Management (TEEM) is a recent control approach that improves transient operability in an effort to enable more efficient and lighter weight turbomachinery. This study seeks to expand TEEM’s application beyond traditional proportional integral (PI) control by presenting linear model predictive control (MPC) schemes to execute the TEEM concept. Through constraint selection and cost function design, transient operability goals for TEEM are considered with no external logic or saturation. Unique to the designs are the use of a washout filter, which simplifies transient detection and motor activation logic. The proposed architectures are implemented with both centralized MPC and distributed MPC approaches, and comparisons are drawn to a benchmark PI controller simulated on a nonlinear turbofan engine model at one ground condition and one cruise condition. Performance is evaluated using compressor maps, stall margin performance, and two novel metrics: transient stack usage and transient excursion integral. Results reveal the linear MPC scheme performs comparably to the baseline controller and can be implemented in at least two distinct configurations with potential for further modifications, thus establishing the groundwork for future investigations.

Model Predictive Control↗

Model Predictive Control Strategies for Turbine Electrified Energy Management

The increasing electrification of aircraft propulsion systems is leading to new control architectures being developed to address integration between electric machines and gas-based turbine engines. For hybrid-electric propulsion systems, current conceptual architectures often couple electric machines with the shafts of gas turbine engines and introduce energy storage. Leveraging the electrical power system of hybridized engines, Turbine Electrified Energy Management (TEEM) is a recent control approach that improves transient operability in an effort to enable more efficient and lighter weight turbomachinery. This study seeks to expand TEEM’s application beyond traditional proportional-integral (PI) control by presenting linear model predictive control (MPC) schemes to execute the TEEM concept. Through constraint selection and cost function design, transient operability goals for TEEM are considered with no external logic or saturation. Unique to the designs are the use of a washout filter, which simplifies transient detection and motor activation logic. The proposed architectures are implemented with both centralized MPC and distributed MPC approaches, and comparisons are drawn to a benchmark PI controller simulated on a nonlinear turbofan engine model at one ground condition and one cruise condition. Performance is evaluated using compressor maps, stall margin performance, and two novel metrics: transient stack usage and transient excursion integral. Results reveal the linear MPC scheme performs comparably to the baseline controller and can be implemented in at least two distinct configurations with potential for further modifications, thus establishing the groundwork for future investigations.

Model Predictive Control↗

Model Predictive Control Strategies for Turbine Electrified Energy Management

The increasing electrification of aircraft propulsion systems is leading to new control architectures being developed to address integration between electric machines and gas-based turbine engines. For hybrid-electric propulsion systems, current conceptual architectures often couple electric machines with the shafts of gas turbine engines and introduce energy storage. Leveraging the electrical power system of hybridized engines, Turbine Electrified Energy Management (TEEM) is a recent control approach that improves transient operability in an effort to enable more efficient and lighter weight turbomachinery. This study seeks to expand TEEM’s application beyond traditional proportional-integral (PI) control by presenting linear model predictive control (MPC) schemes to execute the TEEM concept. Through constraint selection and cost function design, transient operability goals for TEEM are considered with no external logic or saturation. Unique to the designs are the use of a washout filter, which simplifies transient detection and motor activation logic. The proposed architectures are implemented with both centralized MPC and distributed MPC approaches, and comparisons are drawn to a benchmark PI controller simulated on a nonlinear turbofan engine model at one ground condition and one cruise condition. Performance is evaluated using compressor maps, stall margin performance, and two novel metrics: transient stack usage and transient excursion integral. Results reveal the linear MPC scheme performs comparably to the baseline controller and can be implemented in at least two distinct configurations with potential for further modifications, thus establishing the groundwork for future investigations.

Model Predictive Control↗

Size-resolved Eddy-Covariance Particle Flux Measurement during the TRACER Campaign (Final Report)

The main goal of the TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign was to study aerosol–cloud interactions during deep convection over the Houston area. This project deployed a suite of instrumentation with the aim to (1) quantify turbulent vertical particle fluxes during at DOE-ARM sites, including TRACER, (2) assess hygroscopic growth factors and hygroscopicity parameters of the material driving modal aerosol growth during new particle formation and growth events, (3) derive turbulent aerosol mass fluxes using co-located Doppler LIDAR measurements, and (4) create quality-controlled PI data products to support future research utilizing data collected during the TRACER campaign. This report summarized the main findings from the deployments at two DOE-ARM sites. Briefly, we found that new particle formation may occur aloft, in a residual layer, near the top of the boundary layer. Small grown particles appear later due to downward mixing with daytime turbulence. The species that are responsible for aerosol modal growth had hygroscopicity parameters varying between 0.05 and 0.34. These values systematically depended on the wind sector, suggesting that the chemical composition of the precursors differed. This work demonstrated that lidar retrievals of the elastic backscatter and Doppler velocity can be used to obtain surface number emissions of particles with a diameter greater than 0.53 µm. During TRACER, emission particle number fluxes peaked near ∼ 100 cm−2 s−1. Multiple quality-controlled PI data products that will support future TRACER related science were generated and made publically available.

54 ENVIRONMENTAL SCIENCES↗

DC Link Voltage Balancing of the Active Front-End for the Extreme Fast Charging Stations

One of the most important challenges of the extreme fast charging (XFC) stations is to balance the DC link voltages of the active front-end (AFE). The multilevel cascaded H-bridge (CHB) converter is a great topology for the AFE applications due to the high power density, low total harmonic distortion (THD), and a low number of active and passive components. In this paper, a technique is proposed for balancing DC-link capacitor voltages of a three-phase CHB converter, when a phase shiftPWM modulation technique is used on all cells of the converter. To reach this goal, the redundant states of the CHB converters are used for generating different AC voltage levels by sorting the voltages of the converters. The proposed voltage balancing technique uses the principles that are employed for the DC link voltage balancing of the low-frequency modulation techniques to balance the DC link voltages of the CHB converter. As shown in this paper, the DC link voltages of the CHB converter can accurately be balanced very fast without using PI controllers, which are used in the conventional DC link voltage balancing techniques. A controller also is proposed which will be used to control the dq currents of the CHB converter. To verify the advantages of the proposed technique, the simulation results of the proposed technique will be carried out in a three-phase 7-cell CHB AFE.

Grid-tied converters, cascaded H-bridge, DC link v↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

High-speed spiral imaging technique for an atomic force microscope using a linear quadratic Gaussian controller

This paper demonstrates a high-speed spiral imaging technique for an atomic force microscope (AFM). As an alternative to traditional raster scanning, an approach of gradient pulsing using a spiral line is implemented and spirals are generated by applying single-frequency cosine and sine waves of slowly varying amplitudes to the X and Y-axes of the AFM’s piezoelectric tube scanner (PTS). Due to these single-frequency sinusoidal input signals, the scanning process can be faster than that of conventional raster scanning. A linear quadratic Gaussian controller is designed to track the reference sinusoid and a vibration compensator is combined to damp the resonant mode of the PTS. An internal model of the reference sinusoidal signal is included in the plant model and an integrator for the system error is introduced in the proposed control scheme. As a result, the phase error between the input and output sinusoids from the X and Y-PTSs is reduced. The spirals produced have particularly narrow-band frequency measures which change slowly over time, thereby making it possible for the scanner to achieve improved tracking and continuous high-speed scanning rather than being restricted to the back and forth motion of raster scanning. As part of the post-processing of the experimental data, a fifth-order Butterworth filter is used to filter noises in the signals emanating from the position sensors and a Gaussian image filter is used to filter the images. A comparison of images scanned using the proposed controller (spiral) and the AFM PI controller (raster) shows improvement in the scanning rate using the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance

This paper presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This paper analyzes the multi-objective, multi-degree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulse-width modulation (SVPWM), average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5 kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

14 SOLAR ENERGY↗

Reinforcement learning applied to dilute combustion control for increased fuel efficiency

To reduce the modeling burden for control of spark-ignition engines, reinforcement learning (RL) has been applied to solve the dilute combustion limit problem. Q-learning was used to identify an optimal control policy to adjust the fuel injection quantity in each combustion cycle. A physics-based model was used to determine the relevant states of the system used for training the control policy in a data-efficient manner. The cost function was chosen such that high cycle-to-cycle variability (CCV) at the dilute limit was minimized while maintaining stoichiometric combustion as much as possible. Experimental results demonstrated a reduction of CCV after the training period with slightly lean combustion, contributing to a net increase in fuel conversion efficiency of 1.33%. To ensure stoichiometric combustion for three-way catalyst compatibility, a second feedback loop based on an exhaust oxygen sensor was incorporated into the fuel quantity controller using a slow proportional-integral (PI) controller. The closed-loop experiments showed that both feedback loops can cooperate effectively, maintaining stoichiometric combustion while reducing combustion CCV and increasing fuel conversion efficiency by 1.09%. Finally, a modified cost function was proposed to ensure stoichiometric combustion with a single controller. In addition, the learning period was shortened by half to evaluate the RL algorithm performance on limited training time. Experimental results showed that the modified cost function could achieve the desired CCV targets, however, the learning time was reduced by half and the fuel conversion efficiency increased only by 0.30%.

33 ADVANCED PROPULSION SYSTEMS↗

Hardware Evolution of Analog Speed Controllers for a DC Motor

This viewgraph presentation provides information on the design of analog speed controllers for DC motors on aerospace systems. The presentation includes an overview of controller evolution, evolvable controller configuration, an emphasis on proportion integral (PI) controllers, schematic diagrams, and experimental results.

Gwaltney, David A.↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗