Search NASASearch

SEARCH · Search NASA

Results for “PIV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PIV Measurements of Shock-Wave/Boundary-Layer Interactions at Mach 2.5 in a Circular Test Section

The particle image velocimetry (PIV) measurement technique has been applied to make detailed measurements in an impinging shock-wave/boundary-layer interaction (SWBLI) flowfield in a test section of circular cross-section. By virtue of this test section geometry, the flowfields studied are free from effects of the complex coupling of sidewall and corner interaction into the primary impinging shock interaction typical of a rectangular test section. The cone-cylinder shock generator hardware was arranged in both coaxial alignment with the test section to generate axisymmetric SWBLIs and in offset positions to generate swept SWBLIs. The angle of the conical section was also varied to alter the strength of the impinging shock wave. The application of the PIV technique in this test section required meticulous design to provide adequate optical access without disturbing the SWBLI flow. Details of the stereoscopic PIV apparatus and the velocity measurements obtained for a Mach 2.5 freestream are presented. Key features of the mean velocity and turbulent stress fields are highlighted. This data set should enable validation of computational fluid dynamics results for these flowfields.

Shockwave Boundary Layer Interaction

PIV Measurements of Shock-Wave/Boundary-Layer Interactions at Mach 2.5 in a Circular Test Section

The particle image velocimetry (PIV) measurement technique has been applied to make detailed measurements in an impinging shock-wave/boundary-layer interaction (SWBLI) flowfield in a test section of circular cross-section. By virtue of this test section geometry, the flowfields studied are free from effects of the complex coupling of sidewall and corner interaction into the primary impinging shock interaction typical of a rectangular test section. The cone-cylinder shock generator hardware was arranged in both coaxial alignment with the test section to generate axisymmetric SWBLIs and in offset positions to generate swept SWBLIs. The angle of the conical section was also varied to alter the strength of the impinging shock wave. The application of the PIV technique in this test section required meticulous design to provide adequate optical access without disturbing the SWBLI flow. Details of the stereoscopic PIV apparatus and the velocity measurements obtained for a Mach 2.5 freestream are presented. Key features of the mean velocity and turbulent stress fields are highlighted. This data set should enable validation of computational fluid dynamics results for these flowfields.

Shockwave Boundary Layer Interaction

Analysis of Particle Image Velocimetry (PIV) Data for Acoustic Velocity Measurements

Acoustic velocity measurements were taken using Particle Image Velocimetry (PIV) in a Normal Incidence Tube configuration at various frequency, phase, and amplitude levels. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Estimates of lower measurement sensitivity levels were determined based on PIV image quality, correlation, and noise level parameters used in the test. Comparison of measurements with linear acoustic theory are presented. The onset of nonlinear, harmonic frequency acoustic levels were also studied for various decibel and frequency levels ranging from 90 to 132 dB and 500 to 3000 Hz, respectively.

Blackshire, James L.

Analysis of Particle Image Velocimetry (PIV) Data for Application to Subsonic Jet Noise Studies

Global velocimetry measurements were taken using Particle Image Velocimetry (PIV) in the subsonic flow exiting a 1 inch circular nozzle in an attempt to better understand the turbulence characteristics of its shear layer region. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Custom data analysis and data validation algorithms were developed and applied to a data ensemble consisting of over 750 PIV 70 mm photographs taken in the 0.85 mach flow facility. Results are presented detailing spatial characteristics of the flow including ensemble mean and standard deviation, turbulence intensities and Reynold's stress levels, and 2-point spatial correlations.

Blackshire, James L.

MSTB 2 x 6-Inch Low Speed Tunnel Turbulence Generator Grid/Honeycomb PIV Measurements and Analysis

An assessment of the turbulence levels present in the Measurement Science and Technology (MSTB) branch's 2 x 6-inch low speed wind tunnel was made using Particle Image Velocimetry (PIV), and a turbulence generator consisting of a grid/honeycomb structure. Approximately 3000 digital PIV images were captured and analyzed covering an approximate 2 x 6-inch area along the centerline of the tunnel just beyond the turbulence generator system. Custom software for analysis and acquisition was developed for semi-automated digital PIV image acquisition and analysis. Comparisons between previously obtained LTA and LV turbulence measurements taken in the tunnel are presented.

Blackshire, James L.

Digital PIV (DPIV) Software Analysis System

A software package was developed to provide a Digital PIV (DPIV) capability for NASA LaRC. The system provides an automated image capture, test correlation, and autocorrelation analysis capability for the Kodak Megaplus 1.4 digital camera system for PIV measurements. The package includes three separate programs that, when used together with the PIV data validation algorithm, constitutes a complete DPIV analysis capability. The programs are run on an IBM PC/AT host computer running either Microsoft Windows 3.1 or Windows 95 using a 'quickwin' format that allows simple user interface and output capabilities to the windows environment.

Blackshire, James L.

Velocity Fields of Axisymmetric Hydrogen-Air Counterflow Diffusion Flames from LDV, PIV, and Numerical Computation

Laminar fuel-air counterflow diffusion flames (CFDFs) were studied using axisymmetric convergent-nozzle and straight-tube opposed jet burners (OJBs). The subject diagnostics were used to probe a systematic set of H2/N2-air CFDFs over wide ranges of fuel input (22 to 100% Ha), and input axial strain rate (130 to 1700 Us) just upstream of the airside edge, for both plug-flow and parabolic input velocity profiles. Laser Doppler Velocimetry (LDV) was applied along the centerline of seeded air flows from a convergent nozzle OJB (7.2 mm i.d.), and Particle Imaging Velocimetry (PIV) was applied on the entire airside of both nozzle and tube OJBs (7 and 5 mm i.d.) to characterize global velocity structure. Data are compared to numerical results from a one-dimensional (1-D) CFDF code based on a stream function solution for a potential flow input boundary condition. Axial strain rate inputs at the airside edge of nozzle-OJB flows, using LDV and PIV, were consistent with 1-D impingement theory, and supported earlier diagnostic studies. The LDV results also characterized a heat-release hump. Radial strain rates in the flame substantially exceeded 1-D numerical predictions. Whereas the 1-D model closely predicted the max I min axial velocity ratio in the hot layer, it overpredicted its thickness. The results also support previously measured effects of plug-flow and parabolic input strain rates on CFDF extinction limits. Finally, the submillimeter-scale LDV and PIV diagnostics were tested under severe conditions, which reinforced their use with subcentimeter OJB tools to assess effects of aerodynamic strain, and fueVair composition, on laminar CFDF properties, including extinction.

Pellett, Gerald L.

Application of Stereo PIV on a Supersonic Parachute Model

The Mars Science Laboratory (MSL) is the next step in NASA's Mars Exploration Program, currently scheduled for 2011. The spacecraft's descent into the Martian atmosphere will be slowed from Mach 2 to subsonic speeds via a large parachute system with final landing under propulsive control. A Disk-Band-Gap (DBG) parachute will be used on MSL similar to the designs that have been used on previous missions, however; the DBG parachute used by MSL will be larger (21.5 m) than in any of the previous missions due to the weight of the payload and landing site requirements. The MSL parachute will also deploy at higher Mach number (M 2) than previous parachutes, which can lead to instabilities in canopy performance. Both the increased size of the DBG above previous demonstrated configurations and deployment at higher Mach numbers add uncertainty to the deployment, structural integrity and performance of the parachute. In order to verify the performance of the DBG on MSL, experimental testing, including acquisition of Stereo Particle Imaging Velocimetry (PIV) measurements were required for validating CFD predictions of the parachute performance. A rigid model of the DBG parachute was tested in the 10x10 foot wind tunnel at GRC. Prior to the MSL tests, a PIV system had never been used in the 10x10 wind tunnel. In this paper we discuss some of the technical challenges overcome in implementing a Stereo PIV system with a 750x400 mm field-of-view in the 10x10 wind tunnel facility and results from the MSL hardshell canopy tests.

Wernet, Mark P.

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48 cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Raman Scattering

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Wernet, Mark P.

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Turbulence Modeling

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

IR camera Measurments

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part 1

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

Raman Scattering

Validation and Uncertainty Analysis of Stereo Time-Resolved PIV Measurements for Boundary-Layer Transition Research

An uncertainty analysis was performed on the stereo time-resolved particle image velocimetry measurements that were obtained in the boundary-layer of a swept wing model. Several different approaches were undertaken to estimate the uncertainty of the PIV measurements and to understand how that uncertainty propagates through to the results of interest. It was found that the stereo registration error, which is often neglected in stereo- PIV uncertainty analysis, can cause significant errors in the measured amplitude of the stationary cross ow instability due to the large spanwise velocity gradients that occur in the ow. The self-calibrations do not always adequately correct for the stereo-registration error. A simple approach is demonstrated for estimating the error due to a misalignment of the calibration target and laser plane. This approach was found to be very successful at predicting the error in stationary cross ow amplitude caused by the misalignment. The time-resolved PIV results are also compared to previously-acquired hotwire data. The TRPIV technique is successful at measuring the same types of unsteady instabilities as the hotwire, and thus does not appear to have any adverse e ect on the transition process due to the introduction of particles into the ow. It was also found that a larger interrogation window size is beneficial for reducing the noise of the TRPIV results.

Eppink, Jenna L.

Update on the Juncture Flow PIV Results and Future Plans

A novel, embedded, 2D Particle Image Velocimetry system has been developed and implemented to obtain off-body velocity measurements in the junction of an 8% wing-body configuration in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. Although the initial purpose for implementing the system during this test was to evaluate system performance and identify potential risks, a considerable amount of data were obtained in the wing-fuselage junction near the trailing edge at a Reynolds Number of 2.4 Million and angle of attack of 5 degrees. In addition to providing notable efficiencies with regard to image acquisition and test operations, the PIV system captured unique details of the flow separation to complement the extensive suite of measurement techniques applied during the test. Instantaneous PIV vector fields reveal that the flow separation is not stationary but rather highly dynamic. Mean flow statistics calculated from the PIV measurements highlight where reverse flow and Reynolds stresses are concentrated in the separated region and agree well with results from the embedded Laser Doppler Velocimeter system and Computational Fluid Dynamics. The comparisons and ional insight gained during this effort will help guide system improvements for the upcoming entry in 2020.

Jenkins, Luther N.

Plug20 Test Report: Particle Image Velocimetry (PIV) Measurements

This report provides turbulent flow statistics made using particle image velocimetry (PIV) for several internally mixed exhaust systems with external plugs (Plug20 designs). The tests were conducted at the NASA Glenn Research Center’s Aero-Acoustic Propulsion Laboratory (AAPL) in May and June 2022. The corresponding acoustic data for the configurations and flows presented in this report can be found in an earlier Technical Memorandum, NASA/TM-20210010291, “Plug20 Test Report.” The Plug20 nozzle family was designed to represent commercial supersonic vehicles in the 2025 to 2035 timeframe with a bypass ratio around 4, having an internal mixer, with and without an external plug to improve nacelle boattail drag and shock. The flow conditions measured represent engine cycles for commercial supersonic aircraft at takeoff, having pressure ratios of 2.0 and heated fan and core streams, measured both with and without a flight stream surrounding the plume. A few unheated flow conditions were also tested to tie results to other baseline test results. The PIV measurements in both streamwise and cross-stream planes are described, along with brief analysis to visually catalog the contents and confirm their validity. In this analysis, the streamwise PIV is found to match benchmark datasets within its experimental error. However, the cross-stream turbulent quantities measured by two systems do not match each other or the streamwise measurements in amplitude—caution is required when using the cross-stream data. Data acquired and included in this report are (1) velocity statistics of the plumes in both a streamwise and several cross-stream planes, and (2) the hot nozzle geometry. Tabular forms of the data and computer-aided design (CAD) files of the hot geometry are presented as supplemental files described in Appendix A (TM-20230006779SUPPL1.zip) and Appendix B (TM-20230006779SUPPL2.zip).

Turbulence

A histogram-based technique for rapid vector extraction from PIV photographs

A new analysis technique, performed totally in the image plane, is proposed which rapidly extracts all available vectors from individual interrogation regions on PIV photographs. The technique avoids the need for using Fourier transforms with the associated computational burden. The data acquisition and analysis procedure is described, and results of a preliminary simulation study to evaluate the accuracy of the technique are presented. Recently obtained PIV photographs are analyzed.

Humphreys, William M., Jr.

PIV Data Validation Software Package

A PIV data validation and post-processing software package was developed to provide semi-automated data validation and data reduction capabilities for Particle Image Velocimetry data sets. The software provides three primary capabilities including (1) removal of spurious vector data, (2) filtering, smoothing, and interpolating of PIV data, and (3) calculations of out-of-plane vorticity, ensemble statistics, and turbulence statistics information. The software runs on an IBM PC/AT host computer working either under Microsoft Windows 3.1 or Windows 95 operating systems.

Blackshire, James L.