At least 37 records · Page 2

Effect of insulator sleeve material on the x-ray emission from a plasma focus device

The effect of insulator sleeve material on x-ray emission from a 2.3 kJ Mather type plasma focus device operated in argon-hydrogen mixture is investigated. The time and space resolved x-ray emission characteristics are studied by using a three channel p-i-n diode x-ray spectrometer and a multipinhole camera. The x-ray emission depends on the volumetric ratio of argon-hydrogen mixture as well as the filling pressure and the highest x-ray emission is observed for a volumetric ratio 40% Ar to 60%H{sub 2} at 2.5 mbar filling pressure. The fused silica insulator sleeve produces the highest x-ray emission whereas nonceramic insulator sleeves such as nylon, Perspex, or Teflon does not produce focus or x-rays. The pinhole images of the x-ray emitting zones reveal that the contribution of the Cu K{alpha} line is weak and plasma x-rays are intense. The highest plasma electron temperature is estimated to be 3.3 and 3.6 keV for Pyrex glass and fused silica insulator sleeves, respectively. It is speculated that the higher surface resistivity of fused silica is responsible for enhanced x-ray emission and plasma electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and Simulations of Neutron Emission Versus Deuterium Filling Pressure in Plasma Focus Device PF-24

A series of experiments were carried out using the middle energy (dense) plasma focus device PF-24 with deuterium as a working gas under pressure in a range between 2 and 5 mbar for 17 kV of charging voltage. The relationship between these operating deuterium pressures in reference to the total neutron yield (Y{sub n}) was estimated. The 5-phase Lee code was used to simulate the measured discharge current and neutron yield (Y{sub n}) using a phenomenological beam-target neutron generating mechanism, which was incorporated in the model. Comparison of the Y{sub n} versus pressure using fitted model parameters was made at each point of pressure. The good agreement between measured and computed Y{sub n} values was achieved for discharges with lower neutron emission. The measured Y{sub n} (below 2.6 × 10{sup 9} n/discharge—the median value) has been reproducible by the model for 73% of simulated discharges, while above the median value its prediction were incorrect. The kinetic plasma parameters which were measured and computed using the Lee code for different pressures are: the time to a current sheath collapse (t{sub c}), the average axial current sheath velocity (v{sub z}) and the so called velocity factor (RF). Good agreement was found in the whole range of deuterium pressures between the computed and measured results for these kinematic quantities. Presented findings in this work suggest that the character of neutron emission is more complex than it would seem from classical interpretation of neutron production based on a beam-target model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation of current drop, filling gas pressure, and ion beam emission in a low energy Mather-type plasma focus device

The behavior of current drop and its correlation with ion beam emission during the radial phase of a high inductance low energy Mather type plasma focus device have been studied. The study includes two ranges of filling gas pressure, namely the low range of 0.2-0.8 mbar and the high range of 0.8-1.5 mbar. Two different current simulation processes were performed to aid the interpretation of the experimental results. Within the low range of operating pressure, an acceptable match between the computed and experimental current signals was achieved when the effects of anomalous resistances were contemplated. While in the high range of pressure, the computed and experimental current traces were in line even without considering the effects of anomalous resistances. The analysis shows that by decreasing the filling gas pressure the effects of instabilities are intensified. The computed and experimental current traces, along with ion beam signals gathered from a faraday cup, show that there is a strong correlation between the intensity of ion beam and its duration with the current drop during the radial phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of bismuth nanospheres deposited by plasma focus device

A new method for producing thin layer of bismuth nanospheres based on the use of low energy plasma focus device is demonstrated. Various techniques such as scanning electron microscopy, Rutherford backscattering spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy have been used to characterize the morphology and the composition of the nanospheres. Experimental parameters may be adjusted to favour the formation of bismuth nanospheres instead of microspheres. Therefore, the formation of large surface of homogeneous layer of bismuth nanospheres with sizes of below 100 nm can be obtained. The natural snowball phenomenon is observed to be reproduced in nanoscale where spheres roll over the small nanospheres and grow up to bigger sizes that can reach micro dimensions. The comet-like structure, a reverse phenomenon to snowball is also observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Pyrex and quartz insulators contamination effect on the X-ray intensity in a 4-kJ plasma focus device

The variation of the X-ray intensity has been investigated with the Pyrex and quartz insulators surface contamination in a 4-kJ plasma focus device with argon gas at 11.5-kV charging voltage. Elemental analysis (EDAX) showed that the Cu evaporated from the electrode material and was deposited on the sleeve surface improves the breakdown conditions. A small level of sleeve contamination by copper is found to be essential for good focusing action and high HXR intensity. The SEM imaging showed the grain-type structure of Cu formed on the surface and it changed the surface property. Resistance measurements of original and coated Pyrex surface proved that the copper deposition on the sleeve surface will reduce its resistance as compared to the almost infinitely large resistance of the uncontaminated sleeve. As the contamination is surpassed to some critical level, the HXR intensity from the device is deteriorated.

36 MATERIALS SCIENCE↗

Statistical characterization of the reproducibility of neutron emission of small plasma focus devices

The purpose of this work is to discuss the techniques related to the detection of fast pulsed neutrons produced in plasma focus (PF) devices, the statistical analysis of the corresponding data, and the methodologies for evaluation of the device performance in low emission neutron sources. A general mathematical framework is presented for the assessment of the reproducibility of the neutron emission of small PF devices given the shot-to-shot distribution and detector efficiency. The effect on the reproducibility in case of using two independent detectors is also discussed. The analysis is applied to the neutron emission of the plasma focus device PF-50J operating in repetitive mode (0.1-0.5 Hz and 65 J bank energy).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super-strong magnetic field-dominated ion beam dynamics in focusing plasma devices

High energy density physics is the field of physics dedicated to the study of matter and plasmas in extreme conditions of temperature, densities and pressures. It encompasses multiple disciplines such as material science, planetary science, laboratory and astrophysical plasma science. For the latter, high energy density states can be accompanied by extreme radiation environments and super-strong magnetic fields. The creation of high energy density states in the laboratory consists in concentrating/depositing large amounts of energy in a reduced mass, typically solid material sample or dense plasma, over a time shorter than the typical timescales of heat conduction and hydrodynamic expansion. Laser-generated, high current–density ion beams constitute an important tool for the creation of high energy density states in the laboratory. Focusing plasma devices, such as cone-targets are necessary in order to focus and direct these intense beams towards the heating sample or dense plasma, while protecting the proton generation foil from the harsh environments typical of an integrated high-power laser experiment. A full understanding of the ion beam dynamics in focusing devices is therefore necessary in order to properly design and interpret the numerous experiments in the field. In this work, we report a detailed investigation of large-scale, kilojoule-class laser-generated ion beam dynamics in focusing devices and we demonstrate that high-brilliance ion beams compress magnetic fields to amplitudes exceeding tens of kilo-Tesla, which in turn play a dominant role in the focusing process, resulting either in a worsening or enhancement of focusing capabilities depending on the target geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modelling of the internal dynamics and density in a tens of joules plasma focus device

Using MHD theory, coupled differential equations were generated using a lumped parameter model to describe the internal behaviour of the pinch compression phase in plasma focus discharges. In order to provide these equations with appropriate initial conditions, the modelling of previous phases was included by describing the plasma sheath as planar shockwaves. The equations were solved numerically, and the results were contrasted against experimental measurements performed on the device PF-50J. The model is able to predict satisfactorily the timing and the radial electron density profile at the maximum compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of anode shape on correlation of neutron emission with pinch energy for a 2.7 kJ Mather-type plasma focus device

Correlation of neutron emission with pinch energy for a Mather-type plasma focus energized by a single capacitor 12.5 muF, 21 kV (2.7 kJ) is investigated by employing time resolved and time integrated detectors for two different anode shapes. The maximum average neutron yield of about 1.3x10{sup 8} per shot is recorded with cylindrical anode, that increases to 1.6x10{sup 8} per shot for tapered anode. At optimum pressure the input energy converted to pinch energy is about 24% for cylindrical anode as compared to 36% for tapered anode. It is found that the tapered anode enhances neutron flux about 25+-5% both in axial and radial directions and also broadens the pressure range for neutron emission as well as pinch energy. The neutron yield and optimum gas filling pressures are found strongly dependent on the anode shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative study of neutron emission from a plasma focus device using two different anode shapes

The neutron emission from a low energy (2.2 kJ) plasma focus (PF) device operated with two different shapes (cylindrical and converging) of anodes has been investigated by employing photomultiplier tube and bubble dosimeter. The neutron emission with each anode is analyzed and the results are compared. It is found that the anode shapes strongly influenced the emission of neutron. The X-ray emission is found to be higher in case of converging anode, while neutron emission is found to be higher in case of cylindrical anode. The neutron yield and energy are found to be highly anisotropic in nature which indicates that the beam target mechanism plays a major role in the neutron emission in a PF device. The speed factor as well as the specific heat ratio of pinch column shows a good agreement with the experimentally observed results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nitrogen soft and hard X-ray emissions using different shapes of anodes in a 4-kJ plasma focus device

The effect of different anode tip geometries on the intensity of soft and hard X-rays emitted from a 4-kJ plasma focus device is investigated using five different anode tips. The shapes of the uppermost region of these anodes (tips) have been cylindrical-flat, cylindrical-hollow, spherical-convex, cone-flat, and cone-hollow. For time-resolved measurement of the emitted X-rays, several BPX-65 pin diodes covered by different filters and a fast plastic scintillator are used. Experimental results have shown that, the highest intensity of the both soft and hard X-ray is recorded in cone-flat, spherical-convex, and cone-hollow tips, respectively. The use of cone-flat anode tip has augmented the emitted X-ray three times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: A portable pulsed neutron source based on the smallest sealed-type plasma focus device

Development and operation of a portable and compact pulsed neutron source based on sealed-type plasma focus (PF) device are reported. The unit is the smallest sealed-type neutron producing PF device. The effective volume of the PF unit is 33 cm{sup 3} only. A compact size single capacitor (4 {mu}F) is used as the energy driver. A battery based power supply unit is used for charging the capacitor and triggering the spark gap. The PF unit is operated at 10 kV (200 J) and at a deuterium gas filling pressure of 8 mb. The device is operated over a time span of 200 days and the neutron emissions have been observed for 200 shots without changing the gas in between the shots. The maximum yield of this device is 7.8 x 10{sup 4} neutrons/pulse. Beyond 200 shots the yield is below the threshold (1050 neutrons/pulse) of our {sup 3}He detector. The neutron energy is evaluated using time of flight technique and the value is (2.49 {+-} 0.27) MeV. The measured neutron pulse width is (24 {+-} 5) ns. Multishot and long duration operations envisage the potentiality of such portable device for repetitive mode of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Common features of particle beams and x-rays generated in a low energy dense plasma focus device

Features of energetic charged particle beams and x-ray emission in a low energy (1–2 kJ) plasma focus (DPF) device are described and the possible mechanism are explained based on circuit analyses and energy balance in the DPF system. In particular, the resistance and the voltage across the plasma column are estimated to explain the mechanisms of the generation of particle beams and hard x-ray. The analysis shows that the total inductance of a DPF might have played a role for enhancement of the particle beams and x-ray emissions during the phase of anomalous resistance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and construction of pulsed neutron diagnostic system for plasma focus device (SBUPF1)

In this paper, two designs of pulsed neutron counter structure are introduced. To increase the activation counter efficiency, BC-400 plastic scintillator plates along with silver foils are utilized. Rectangular cubic and cylindrical geometries for activation counter cell are modeled using MCNP4C code. Eventually, an optimum length of 14 cm is calculated for the detector cell and optimum numbers of 20 silver foils for rectangular cubic geometry and ten foils for cylindrical geometry have been acquired. Due to the high cost of cutting, polishing of plastics, and etc., the rectangular cubic design is found to be more economical than the other design. In order to examine the functionality and ensure the detector output and corresponding designing, neutron yield of a 2.48 kJ plasma focus device (SBUPF1) in 8 mbar pressure with removal source method for calibration was measured (3.71{+-}0.32)x10{sup 7} neutrons per shot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous resistivity effect on multiple ion beam emission and hard x-ray generation in a Mather type plasma focus device

Multi ion beam and hard x-ray emissions were detected in a high inductance (more than 100 nH) Mather type plasma focus (PF) device at different filling gas pressures and charging voltages. The signal analysis was performed through the current trace, as it is the fundamental signal from which all of the phenomena in a PF device can be extracted. Two different fitting processes were carried out according to Lee's computational (snow-plow) model. In the first process, only plasma dynamics and classical (Spitzer) resistances were considered as energy consumer parameters for plasma. This led to an unsuccessful fitting and did not answer the energy transfer mechanism into plasma. A second fitting process was considered through the addition of anomalous resistance, which provided the best fit. Anomalous resistance was the source of long decrease in current trace, and multi dips and multi peaks of high voltage probe. Multi-peak features were interpreted considering the second fitting process along with the mechanisms for ion beam production and hard x-ray emission. To show the important role of the anomalous resistance, the duration of the current drop was discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of measured and computed radial trajectories of plasma focus devices UMDPF1 and UMDPF0

In published literature, there has been scant data on radial trajectory of the plasma focus and no comparison of computed with measured radial trajectory. This paper provides the first such comparative study. We compute the trajectories of the inward-moving radial shock and magnetic piston of UMDPF1 plasma focus and compare these with measured data taken from a streak photograph. The comparison shows agreement with the measured radial trajectory in terms of average speeds and general shape of trajectory. This paper also presents the measured trajectory of the radially compressing piston in another machine, the UMDPF0 plasma focus, confirming that the computed radial trajectory also shows similar general agreement. Features of divergence between the computed and measured trajectories, towards the end of the radial compression, are discussed. From the measured radial trajectories, an inference is made that the neutron yield mechanism could not be thermonuclear. A second inference is made regarding the speeds of axial post-pinch shocks, which are recently considered as a useful tool for damage testing of fusion-related wall materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗