Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES, FLAT - STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Production of Fatty Acids and Protein by Nannochloropsis in Flat-Plate Photobioreactors

Nannochloropsis is an industrially-promising microalga that may be cultivated for alternative sources of nutrition due to its high productivity, protein content and lipid composition. We studied the growth and biochemical profile of Nannochloropsis 211/78 (CCAP) in optimized flat-plate photobioreactors. Eighteen cultivations were performed at two nutrient concentrations. The fatty acid, protein content and calorific values were analyzed after 8, 12 and 16 days. Neutral lipids were separated and the changes in fatty acids in triglycerides (TAGs) during nutrient depletion were recorded. The maximum cell density reached 4.7 g L -1 and the maximum productivity was 0.51 g L -1 d -1 . During nutrient-replete conditions, eicosapentaneoic acid (EPA) and total protein concentrations measured 4.2–4.9% and 50–55% of the dry mass, respectively. Nutrient starvation induced the accumulation of fatty acids up to 28.3% of the cell dry weight, largely due to the incorporation of C16:0 and C16:1n-7 fatty acyl chains into neutral lipids. During nutrient starvation the total EPA content did not detectibly change, but up to 37% was transferred from polar membrane lipids to the neutral lipid fraction.

59 BASIC BIOLOGICAL SCIENCES↗

System Advisor Model: Flat Plate Photovoltaic Performance Modeling Validation Report

The System Advisor Model (SAM) is a free software tool that performs detailed analysis of both system performance and system financing for a variety of renewable energy technologies. This report provides detailed validation of the SAM flat plate photovoltaic performance model by comparing SAM-modeled PV system generation data to actual measured production data for nine PV systems ranging from 75 kW to greater than 25 MW in size. The results show strong agreement between SAM predictions and field data, with annualized prediction error below 3% for all fixed tilt cases and below 8% for all one axis tracked cases. The analysis concludes that snow cover and system outages are the primary sources of disagreement, and other deviations resulting from seasonal biases in the irradiation models and one axis tracking issues are discussed in detail.

14 SOLAR ENERGY↗

Analysis of impact to optical environment of the land by flat-plate and array of tracking PV panels

The impact to the optical environment result from shading of PV panels becomes concerned. This paper describes how to calculate illumination level on the land around tracking PV (both isolated and arrayed) panel. The land under the flat-plate PV is dark by shading, but the influence from the tracking PV is not very significant, typically half in average. This is because shadow by tracking panel moves. The shading influence is further decreased with the increase of pedestal height. We report with this advantage, tracking PV can be combined with agriculture as a double use of the land.

14 SOLAR ENERGY↗

Dependence of Techno-Economic and Ecological Indicators of Flat-Plate Solar Water Heating Collectors in Hot Water Supply Systems from the Temperature of Heating Water

The main ways of improving the performance efficiency of solar energy (SE) use in hot water supply systems (HWSSs) are discussed. It is established that the environmental characteristics of flat-plate solar water heating collectors (FPSWHCs) for heating water in HWSSs depend on the water heating temperature in these systems.

14 SOLAR ENERGY↗

Calculation of the temperature of the internal surface of the heat-removing channel wall of the ray-absorbing heat-exchange panels of flat-plate solar water-heating collectors

The results of numerical research on the determination of the temperature value of the internal surface of the heat-removing channel (HRC) walls of the light-absorbing heat-exchange panels (LAHPs) with the tubeon- sheet and thin-parallelepiped form of flat-plate solar water-heating collectors (FPSWHCs) are presented. The research method is based on compilation of the system of the balance equations for the light-absorbing plate (LAP) and HRCs of the LAHPs of the studied types and their designs with respect to the desired parameter. A practical example of calculation of the determination of the temperature value of the internal surface of the HRC wall of the tube-on-sheet LAHP, where the results of experimental research on the determination of the specific thermal efficiency of the mean-quality FPSWHC in full-scale terms, as well as laboratory and numerical research on determination of the optical and thermotechnical indicators of the copper tube-on-sheet LAHP.

14 SOLAR ENERGY↗

Determination of the Convective Heat-Exchange Coefficient in Inner Channels of Light-Absorbing Heat-Exchange Panels of Flat-Plate Solar Water-Heating Collectors Based on the Results of Their Short-Term Thermal Testing in Full-Scale Conditions

The results of investigations to determine the convective heat-exchange coefficient in the inner heat-exchange channels (HECs) of the light-absorbing heat-exchange panels (LAHPs) of flat-plate solar water-heating collectors (FPSWHCs) are given based on the results of their short-term heat testing in fullscale quasi-stationary conditions. The research method is based on determining the value of the required parameter from the heat-balance equation formed for the inner surfaces of the LAHP HEC walls. The structures of the flow LAHPs with a sheet-piped and thin parallelepiped form are selected as the test objects. The thermal tests of the FPSWHC are carried out during the near-midday hours of the light day to ensure the quasi-stationary mode condition. The reliability of the proposed method and results of the investigations is proved by comparing the values of the thermal-efficiency coefficients of the FPSWHC LAHPs obtained using two independent approaches.

14 SOLAR ENERGY↗

The influence of the spectral emissivity of flat-plate calibrators on the calibration of IR thermometers

Flat Calibrators (FC) are an option for calibration of infrared thermometers (IT) with a fixed large target. FCs are neither blackbodies, nor gray-bodies; their spectral emissivity is lower than one and depends on wavelength. Nevertheless they are used as gray-bodies with a nominal emissivity value. FCs can be calibrated radiometrically using as reference a calibrated IR thermometer (RT). If an FC will be used to calibrate ITs that work in the same spectral range as the RT then its calibration is straightforward: the actual FC spectral emissivity is not required. This result is valid for any given fixed emissivity assessed to the FC. On the other hand, when the RT working spectral range does not match with that of the ITs to be calibrated with the FC then it is required to know the FC spectral emissivity as part of the calibration process. For this purpose, at CENAM, we developed an experimental setup to measure spectral emissivity in the infrared spectral range, based on a Fourier transform infrared spectrometer. Not all laboratories have emissivity measurement capability in the appropriate wavelength and temperature ranges to obtain the spectral emissivity. Thus, we present an estimation of the error introduced when the spectral range of the RT used to calibrate an FC and the spectral ranges of the ITs to be calibrated with the FC do not match. Some examples are developed for the cases when RT and IT spectral ranges are [8,13] μm and [8,14] μm respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Simulations of High Prandtl Number Liquid Jets Impinging on a Flat Plate

In this work, 3D simulations of oil jets impinging on a flat, heated wall are presented. The numerical setup uses the Volume of Fluid (VoF) method to model the two-phase flow. A careful grid definition across the liquid film, along with the use of the Conjugate Heat Transfer (CHT) approach allowed local heat transfer to be solved with fine resolution at the wall. Variations of liquid flow rate, liquid temperature and surface temperature allow to cover a wide range of local Reynolds and Prandtl numbers (226 < Re < 2850, 77 < Pr < 161). Resulting surface-averaged heat transfer compares very well with experimental measurements conducted in a previous study. In-depth analysis of the flow has identified expected features from the literature. In particular, the impact of jet axial velocity profiles on the heat transfer distribution in the stagnation zone was clearly stated. The increase in heat transfer when warming the liquid film was also reproduced and explained by a decrease in oil viscosity and an increase in film velocity. All those effects were taken into account in correlations for stagnation and local values of Nusselt number. A grid sensitivity study was also conducted, showing that if the grid solving the thermal boundary layer in the stagnation zone can be coarsened without impacting local and surface-averaged predictions of heat transfer, a minimum resolution (2 to 3 cells) within the thermal boundary layer is however required for an accurate prediction of heat transfer.

conjugate heat transfer↗

Experimental Validation Data for Computational Fluid Dynamics of Forced Convection on a Vertical Flat Plate

We present computational fluid dynamics (CFD) validation dataset for turbulent forced convection on a vertical plate. The design of the apparatus is based on recent validation literature and provides a means to simultaneously measure boundary conditions (BCs) and system response quantities (SRQs). Important inflow quantities for Reynolds-Averaged Navier-Stokes (RANS). CFD are also measured. Data are acquired at two heating conditions and cover the range 40,000 < Re x < 300,000, 357 < Re δ 2 < 813, and 0.02 < Gr/Re 2 < 0.232.

42 ENGINEERING↗

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

Counter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. Here, the hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.

17 WIND ENERGY↗