Search NASA⌕ Search

SEARCH · Search NASA

Results for “PMD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Process for Producing Highly Wettable Aluminum 6061 Surfaces Compatible with Hydrazine

NASA's Global Precipitation Measurement (GPM) mission is an ongoing Goddard Space Flight Center (GSFC) project whose basic objective is to improve global precipitation measurements. The space-based portion of the mission architecture consists of a primary or core spacecraft and a constellation of NASA and contributed spacecrafts. The efforts described in this paper refer to the core spacecraft (hereafter referred to as simply GPM) which is to be fabricated at GSFC. It has been decided that the GPM spacecraft is to be a "design-for-demise-spacecraft." This requirement resulted in the need for a propellant tank that would also demise or ablate to an appropriate degree upon re-entry. Composite overwrapped aluminum lined propellant tanks with aluminum propellant management devices (PMD) were shown by analyses to demise and thus became the baseline configuration for GPM. As part of the GPM tank development effort, long term compatibility and wettability testing with hydrazine was performed on Al6061 and 2219 coupons fabricated and cleaned by conventional processes. Long term compatibility was confirmed. However, the wettability of the aluminum as measured by contact angle produced higher than desired angles (greater than 30 deg.) with excessive scatter. The availability of PMD materials exhibiting consistently low contact angles aids in the design of simple PMDs. Two efforts performed by Angeles Crest Engineering and funded by GSFC were undertaken to reduce the risk of using aluminum for the GPM PMD. The goal of the first effort was to develop a cleaning or treatment process to produce consistently low contact angles. The goal of the second effort was to prove via testing that the processed aluminum would retain compatibility with hydrazine and retain low contact angle after long term exposure to hydrazine. Both goals were achieved. This paper describes both efforts and the results achieved.

Moore, N. R.↗

Phaeton Mast Dynamics: On-Orbit Characterization of Deployable Masts

This presentation discusses the Phaeton Mast Dynamics (PMD) instrument architecture and design, including design constraints, design solutions, and instrument results. Since the design and build phases were completed with PMD as a NuSTAR payload, the presentation discusses NuSTAR's constraints and initial accommodations. The instrument results presented here are independent of the host mission, but the effects of a host mission's data handling design on PMD capabilities is discussed in 2011 IEEEAC Paper 1305.

Nuclear Spectroscopic Telescope Array (NuSTAR)↗

Inverted Outflow Ground Testing of Cryogenic Propellant Liquid Acquisition Devices

NASA is currently developing propulsion system concepts for human exploration. These propulsion concepts will require the vapor free acquisition and delivery of the cryogenic propellants stored in the propulsion tanks during periods of microgravity to the exploration vehicles engines. Propellant management devices (PMDs), such as screen channel capillary liquid acquisition devices (LADs), vanes and sponges have been used for earth storable propellants in the Space Shuttle Orbiter and other spacecraft propulsion systems, but only very limited propellant management capability currently exists for cryogenic propellants. NASA is developing PMD technology as a part of their cryogenic fluid management (CFM) project. System concept studies have looked at the key factors that dictate the size and shape of PMD devices and established screen channel LADs as an important component of PMD design. Modeling validated by normal gravity experiments is examining the behavior of the flow in the LAD channel assemblies (as opposed to only prior testing of screen samples) at the flow rates representative of actual engine service (similar in size to current launch vehicle upper stage engines). Recently testing of rectangular LAD channels has included inverted outflow in liquid oxygen and liquid hydrogen. This paper will report the results of liquid oxygen testing compare and contrast them with the recently published hydrogen results; and identify the sensitivity these results to flow rate and tank internal pressure.

Liquid Oxygen↗

Phaeton Mast Dynamics: On-Orbit Characterization of Deployable Masts

The PMD instrument is a set of three custom-designed triaxial accelerometer systems designed specifically to detect and characterize the modal dynamics of deployable masts in orbit. The instrument was designed and built as a payload for the NuSTAR spacecraft, but it is now sponsored by the Air Force Research Laboratory's DSX project. It can detect acceleration levels from 1 micro gram to 0.12g over a frequency range of 0.1Hz to 30Hz, the results of which can support future modeling and designing of deployable mast structures for space. This paper details the hardware architecture and design, calibration test and results, and current status of the PMD instrument.

Phaeton Mast Dynamics (PMD)↗

Definition of display/control requirements for assault transport night/adverse weather capability

A Helicopter Night Vision System was developed to improve low-altitude night and/or adverse weather assult transport capabilities. Man-in-the-loop simulation experiments were performed to define the minimum display and control requirements for the assult transport mission and investigate forward looking infrared sensor requirements, along with alternative displays such as panel mounted displays (PMD) helmet mounted displays (HMD), and integrated control display units. Also explored were navigation requirements, pilot/copilot interaction, and overall cockpit arrangement. Pilot use of an HMD and copilot use of a PMD appear as both the preferred and most effective night navigation combination.

Milelli, R. J.↗

Petrology and classification of the Garraf, Spain chondrite

Microscopic and electron microprobe studies indicate that the Garraf meteorite is a highly-recrystallized chondrite of petrologic type 6. Olivine (Fa24.7; PMD 1.1) and low-Ca pyroxene (Fs20.9; PMD 1.1) compositions indicate that it belongs to the L-group. Based on contents of noble gases, pervasive fracturing of silicates, common undulose extinction of olivine and plagioclase, and the lack of melt pockets and maskelynite, Garraf is placed into shock facies b. It is concluded that Garraf is a highly recrystallized L6b chondrite that, after recrystallization, was cataclased and comminuted by shock.

Keil, K.↗

Accuracy analysis of the space shuttle solid rocket motor profile measuring device

The Profile Measuring Device (PMD) was developed at the George C. Marshall Space Flight Center following the loss of the Space Shuttle Challenger. It is a rotating gauge used to measure the absolute diameters of mating features of redesigned Solid Rocket Motor field joints. Diameter tolerance of these features are typically + or - 0.005 inches and it is required that the PMD absolute measurement uncertainty be within this tolerance. In this analysis, the absolute accuracy of these measurements were found to be + or - 0.00375 inches, worst case, with a potential accuracy of + or - 0.0021 inches achievable by improved temperature control.

Estler, W. Tyler↗

Pulse-Modulation Scheme For Voice And Telemetry

Pulse-modulation scheme provides for transmission of 1 channel of voice information along with 16 channels of serially multiplexed analog iotelemetric information, all on single radio-frequency carrier signal. Encoder/multiplexer combination effects PMD scheme, in which biotelemetry encoded in time-division multiplex PIM, while voice encoded in PWM. Combination of PIM and PWM encoding called "pulse modulated data" or PMD. Principal advantage of scheme simplicity: comodulation of voice along with biotelemetry involves minimal additional circuitry in transmitter. In receiver, biotelemetric data extracted by ordinary PIM-encoding circuitry, not affected by voice PWM; and simple PWM decoder added to receiver to recover voice.

Mills, William J.↗

Liquid Acquisition Device Testing with Sub-Cooled Liquid Oxygen

When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. Previous experimental test programs conducted at NASA have collected LAD data for a number of cryogenic fluids, including: liquid nitrogen (LN2), liquid oxygen (LOX), liquid hydrogen (LH2), and liquid methane (LCH4). The present work reports on additional testing with sub-cooled LOX as part of NASA s continuing cryogenic LAD development program. Test results extend the range of LOX fluid conditions examined, and provide insight into factors affecting predicting LAD bubble point pressures.

Jurns, John M.↗

Cryogenic Propellant Management Device: Conceptual Design Study

Concepts of Propellant Management Devices (PMDs) were designed for lunar descent stage reaction control system (RCS) and lunar ascent stage (main and RCS propulsion) missions using liquid oxygen (LO2) and liquid methane (LCH4). Study ground rules set a maximum of 19 days from launch to lunar touchdown, and an additional 210 days on the lunar surface before liftoff. Two PMDs were conceptually designed for each of the descent stage RCS propellant tanks, and two designs for each of the ascent stage main propellant tanks. One of the two PMD types is a traditional partial four-screen channel device. The other type is a novel, expanding volume device which uses a stretched, flexing screen. It was found that several unique design features simplified the PMD designs. These features are (1) high propellant tank operating pressures, (2) aluminum tanks for propellant storage, and (3) stringent insulation requirements. Consequently, it was possible to treat LO2 and LCH4 as if they were equivalent to Earth-storable propellants because they would remain substantially subcooled during the lunar mission. In fact, prelaunch procedures are simplified with cryogens, because any trapped vapor will condense once the propellant tanks are pressurized in space.

Wollen, Mark↗

Liquid Oxygen Liquid Acquisition Device Bubble Point Tests with High Pressure LOX at Elevated Temperatures

When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122K) as part of NASA s continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

Jurns, John M.↗

A Computational Investigation for Determining the Natural Frequencies and Damping Effects of Diaphragm-Implemented Spacecraft Propellant Tanks

Spin-stabilization maneuvers are typically performed by spacecraft entering low-earth orbit to maintain attitude stability. These maneuvers induce periodic fluid movement inside the spacecraft's propellant tank known as fuel slosh, which is responsible for creating forces and moments on the sidewalls of the propellant tank. These forces and moments adversely affect spin-stabilization and risk jeopardizing the mission of the spacecraft. Therefore, propellant tanks are designed with propellant management devices (PMD's) such as barnes or diaphragms which work to counteract the forces and moments associated with fuel slosh. However, despite the presence of PMD's, the threat of spin-stabilization interference still exists should the propellant tank be excited at its natural frequency. When the fluid is excited at its natural frequency, the forces and moments acting on the propellant tank are amplified and may result in destabilizing the spacecraft. Thus, a computational analysis is conducted concerning diaphragm-implemented propellant tanks excited at their natural frequencies. Using multi-disciplinary computational fluid dynamics (CFD) software, computational models are developed to reflect potential scenarios that spacecraft propellant tanks could experience. By simulating the propellant tank under a wide array of parameters and variables including fill-level, gravity and diaphragm material and shape, a better understanding is gained as to how these parameters individually and collectively affect liquid propellant tanks and ultimately, spacecraft attitude dynamics.

Lenahen, Brian↗

An Update on the Effectiveness of Postmission Disposal in LEO

Orbital debris mitigation measures have been developed to reduce the growth of the future debris population by the international space community over the past two decades. A major component in the overall mitigation strategy is postmission disposal (PMD). A key PMD element for the low Earth orbit (LEO, the region below 2000 km altitude) satellites is the 25-year decay rule. It is intended to limit the long-term presence of massive intact objects - rocket bodies (R/Bs) and spacecraft (S/C) in the environment. The effectiveness of the 25-year rule was well demonstrated and documented during the development of the mitigation measures. The orbital debris population in LEO, unfortunately, has significantly increased since that time. The objectives of this paper are to provide an updated assessment based on the 2012 LEO environment and to highlight the importance of the global compliance of the 25-year decay rule.

Liou, J.-C↗

Mind the Gap: Exploring the Underground of the NASA Space Cancer Risk Model

The REID quantifies the lifetime risk of death from radiation-induced cancer in an exposed astronaut. The NASA Space Cancer Risk (NSCR) 2012 mode incorporates elements from physics, biology, epidemiology, and statistics to generate the REID distribution. The current model quantifies the space radiation environment, radiation quality, and dose-rate effects to estimate a NASA-weighted dose. This weighted dose is mapped to the excess risk of radiation-induced cancer mortality from acute exposures to gamma rays and then transferred to an astronaut population. Finally, the REID is determined by integrating this risk over the individual's lifetime. The calculated upper 95% confidence limit of the REID is used to restrict an astronaut's permissible mission duration (PMD) for a proposed mission. As a statistical quantity characterized by broad, subjective uncertainties, REID estimates for space missions result in wide distributions. Currently, the upper 95% confidence level is over 350% larger than the mean REID value, which can severely limit an astronaut's PMD. The model incorporates inputs from multiple scientific disciplines in the risk estimation process. Physics and particle transport models calculate how radiation moves through space, penetrates spacecraft, and makes its way to the human beings onboard. Epidemiological studies of exposures from atomic bombings, medical treatments, and power plants are used to quantify health risks from acute and chronic low linear energy transfer (LET) ionizing radiation. Biological studies in cellular and animal models using radiation at various LETs and energies inform quality metrics for ions present in space radiation. Statistical methodologies unite these elements, controlling for mathematical and scientific uncertainty and variability. Despite current progress, these research platforms contain knowledge gaps contributing to the large uncertainties still present in the model. The NASA Space Radiation Program Element (SRPE) defines the knowledge gaps that impact our understanding of the cancer risks. These gaps are outlined in NASA's Human Research Roadmap [4], which identifies the research questions and actions recommended for reducing the uncertainty in the current NSCR model and for formulation of future models. The greatest contributors to uncertainty in the current model include radiation quality, dose rate effects, and the transfer of exposure-based risk from other populations to an astronaut population. Future formulations of the risk model may benefit from including other potential sources of uncertainty such as space dosimetry, errors in human epidemiology data, and the impact of microgravity and other spaceflight stressors. Here, we discuss the current capabilities of the NSCR-2012 model and several immediate research needs, highlighting areas expected to have an operational impact on the current model schema. The following subway-style route map outlines the NSCR-2012 model (Green Line), emphasizing the research gaps in the Human Research Roadmap for risk of radiation-induced carcinogenesis (Stops on Dashed Lines). The map diagrams how these research gaps feed specific portions of the model.

Chappell, L. J.↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗