Search NASA⌕ Search

SEARCH · Search NASA

Results for “PMT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Superlinearity, saturation, and the PMT—Tailoring and calibration methodology for prompt radiation detectors

This work illustrates predominant measureable nonlinearities in photomultiplier tubes (PMTs) and introduces a controllable one called “Superlinearity,” signifying both a positive nonlinear response and the ability to extend linear operation by counteracting gain saturation mechanisms — charge depletion, space-charge field limitation, and secondary emission surface effects. Recognizing superlinearity and its effect on the temporal step response leads to a true definition of linearity, free of a small-signal linear assumption. Furthermore, given the prevalent use of glass microchannel-plate (MCP) PMTs in favor of a faster impulse response in spite of a small charge limit, we are motivated to examine their nonlinear amplitude response and deploy tailored gain bias string methods to fully harness the maximum linear gain as is usually done for transmissive metal mesh and reflective metal dynode PMTs. Our characterization methodology applies standard NIST-traceable calibrated laboratory equipment with absolute input-referenced techniques, examining step responses over many orders of magnitude in controlled illumination. By doing so, we quantitatively reveal the superlinearity strength independent of charge depletion, yielding true linear responsivity and effectively doubling the small-signal linear limit; this is very relevant to PMT modeling and charge deconvolution efforts. In conclusion, with further development, the tailoring strategies we introduce could be applied to MCP detectors, extracting all useful capillary charge with a significant improvement in large linear signal quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

PMT F7 Silver Standard Material Properties Characterization

PMT F7 epoxy resin was characterized to capture the material's thermochemical and thermo-mechanical properties. DSC testing was performed and the data was used to develop a cure kinetics model which predicts the material cure response and specific heat capacity. TMA and DMA testing were performed and the data was used to develop thermo-mechanical models which predict the material CTE, cure shrinkage, and modulus evolution with cure. Convergent Manufacturing Technologies US determined test parameters, analyzed data, and performed model fitting. NASA completed tests and provided data to Convergent Manufacturing Technologies US.

Epoxy↗

Hamamatsu PMT R7056 Study for the Extinction Monitoring System of the Mu2e Experiment at Fermilab

The Mu2e experiment at Fermilab proposes to search for the coherent neutrino-less conversion of muons to electrons in the presence of a nucleus. The experimental signature for an aluminum target is an isolated 105 MeV electron exiting the stopping target no earlier than ~700 ns after the pulse of proton beam hits the production target. Any protons that hit the production target in between the pulses can lead to fake conversion electrons during the measurement period. We define the beam extinction as the ratio of the number of protons striking the production target between pulses to the number striking the target during the pulses. It has been established that an extinction of about 10-10 is required to reduce the backgrounds to an acceptable level. It would be desirable to measure the extinction of the beam coming out of the accelerator in a minute or less. Studies for the fast extinction monitor based on Hamamatsu PMT R7056 is the subject of this publication.

43 PARTICLE ACCELERATORS↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

PMT v4.0 Capabilities

Explore the source record for details and available documents.

Project Management Tool↗

Development of a New Fast Shower Maximum Detector Based on Microchannel Plates Photomultipliers (MCP-PMT) as an Active Element

One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photodetectors based on microchannel plates (MCPs) as the secondary emitter. We performed the measurements at the Fermilab Test Beam Facility with 120GeV proton beam and 12GeV and 32GeV secondary beams. The goal of the measurement with 120GeV protons was to determine time resolution for minimum ionizing particles (MIPs). The SM time resolution we obtained for this new type of detector is at the level of 20-30ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP. This work can be considered as the first step in building a new type of calorimeter based on this principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the miniPlanacon XPM85112-S-R2D2 MCP-PMT with custom modified backend electronics

We report the results of the measurements of three pieces of the new Photonis miniPLANACON microchannel-plate photomultipliers (MCP-PMTs) intended for use in the demanding environment of the Large Hadron Collider (LHC) beamline as a part of the AFP Time-of-Flight detector. These photomultipliers were modified in cooperation with the manufacturer by using a custom backend and were subjected to numerous tests, with the focus on the rate capability and crosstalk behaviour. We determined that the two of them with a lower MCP resistance are able to operate without significant saturation at an anode current density of 1 μA/cm 2 . These two are, therefore, suitable for the intended use and are currently installed as part of the AFP detector packages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCP-PMT studies at the High-B test facility at Jefferson Lab

Here we present preliminary results for the gain performance of commercially available 3- mum and 6- mum pore-size single-anode microchannel-plate photomultipliers (MCP PMTs) in magnetic fields up to 5 T and for various orientations of the sensor relative to the field direction. The measurements were performed at Thomas Jefferson National Accelerator Facility in Newport News, VA. Our results show that smaller-pore-size PMTs have better gain performance in magnetic fields. At various angles, the shape of the gain dependence on the strength of the magnetic field strongly depends on the type of the sensor. Also, for each sensor, the azimuthal dependence is strongly correlated with the polar angle. Overall, the sensors exhibit a reasonable performance up to 2 T, although that upper limit depends on the sensor, the applied high voltage, and the orientation of the sensor relative to the field. To optimize the operational and design parameters of MCP PMTs for performance in high magnetic fields, further measurements and simulation studies will be pursued. Furthermore, our studies are part of an R&D for development of a Detector of Internally Reflected Cherenkov Light for the central detector of a future U.S. Electron Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗

D-Egg: a dual PMT optical module for IceCube

The D-Egg, an acronym for "Dual optical sensors in an Ellipsoid Glass for Gen2," is one of the optical modules designed for future extensions of the IceCube experiment at the South Pole. The D-Egg has an elongated-sphere shape to maximize the photon-sensitive effective area while maintaining a narrow diameter to reduce the cost and the time needed for drilling of the deployment holes in the glacial ice for the optical modules at depths up to 2700 m. The D-Egg design is utilized for the IceCube Upgrade, the next stage of the IceCube project also known as IceCube-Gen2 Phase 1, where nearly half of the optical sensors to be deployed are D-Eggs. With two 8-inch high-quantum efficiency photomultiplier tubes (PMTs) per module, D-Eggs offer an increased effective area while retaining the successful design of the IceCube digital optical module (DOM). The convolution of the wavelength-dependent effective area and the Cherenkov emission spectrum provides an effective photodetection sensitivity that is 2.8 times larger than that of IceCube DOMs. The signal of each of the two PMTs is digitized using ultra-low-power 14-bit analog-to-digital converters with a sampling frequency of 240 MSPS, enabling a flexible event triggering, as well as seamless and lossless event recording of single-photon signals to multi-photons exceeding 200 photoelectrons within 10 ns. Mass production of D-Eggs has been completed, with 277 out of the 310 D-Eggs produced to be used in the IceCube Upgrade. In this paper, we report the design of the D-Eggs, as well as the sensitivity and the single to multi-photon detection performance of mass-produced D-Eggs measured in a laboratory using the built-in data acquisition system in each D-Egg optical sensor module.

47 OTHER INSTRUMENTATION↗

Study of Viability and Challenges of using SiPMs as an Alternative to PMT’s in Scintillation Detectors for Nuclear Safeguards

The goals of this project are to identify fundamental and practical problems and features with SiPMs as they relate to IAEA detector needs, Identify published results and implementations of scintillation detectors tat use SiPMs that are of interest to IAEA, asses how effectively the fundamental problems were addresses, and perform simulations and experiments as needed to reproduce crucial results and make recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PMT Gain Calibration In MicroBooNE

Liquid argon (LAr) is an ideal scintillating detector medium: it is very bright, releasing O(10, 000) photons per MeV of deposited energy, and is also transparent to its own scintillation. Light data in liquid argon time projection chamber (LArTPC) experiments in general and MicroBooNE in particular has many important uses. In MicroBooNE, light collected over all photosensors is used as a first and second level trigger. At the data acquisition stage ~ 5PE is required for triggering. An additional software trigger of ≈ 20PE helps reject a large portion of cosmic ray background in events with no neutrino interaction occurring during the beam spill. Scintillation can also be used for the determination of absolute drift coordinate of non-beam related events. Additionally, matching reconstructed light to reconstructed TPC charge is a powerful tool for cosmic ray rejection. Finally due to the specific properties of LAr scintillation, light information can be used for particle identification. For many of these tasks good modeling of the light response of the detector is crucial. Applying data-driven corrections to optical detector data and simulation (prediction) allows to obtain a well calibrated energy scale from the PMTs. This reduces discrepancies between data and simulation, and calibrates out non-uniformities of data over the full data taking period. Thus it is expected to factor in improving systematic uncertainties on MicroBooNE’s flagship analyses - the low energy excess (LEE) search and LAr-ν cross-section measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗