Search NASA⌕ Search

SEARCH · Search NASA

Results for “PNEUMATIC CIRCUIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The M68HC11 gripper controller electronics

This document describes the instrumentation, operational theory, circuit implementation, calibration procedures, and general notes for the CIRSSE general purpose pneumatic hand. The mechanical design and the control software are discussed. The circuit design, PCB layout, hand instrumentation, and controller construction described in detail in this document are the result of a senior project.

Kelley, Robert B.↗

Design and performance of heart assist or artificial heart control systems

The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.

Webb, J. A., Jr.↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.

Pantalos, George M.↗

Embedded Fluidic Sensing and Control with Soft Open‐Cell Foams

Abstract The synthesis of soft matter intelligence with circuit‐driven logic has enabled a new class of robots that perform complex tasks or conform to specialized form factors in unique ways that cannot be realized through conventional designs. Translating this hybrid approach to fluidic systems, the present work addresses the need for sheet‐based circuit materials by leveraging the innate porosity of foam—a soft material—to develop pneumatic components that support digital logic, mixed‐signal control, and analog force sensing in wearables and soft robots. Analytical tools and experimental techniques developed in this work serve to elucidate compressible gas flow through porous sheets, and to inform the design of centimeter‐sized foam resistors with fluidic resistances on the order of 10 9 Pa s m −3 . When embedded inside soft robots and wearables, these resistors facilitate diverse functionalities spanning both sensing and control domains, including digital logic using textile logic gates, digital‐to‐analog signal conversion using ladder networks, and analog sensing of forces up to 40 N via compression‐induced changes in resistance. By combining features of both circuit‐based and materials‐based approaches, foam‐enabled fluidic circuits serve as a useful paradigm for future hybrid robotic architectures that fully embody the sensing and computing capabilities of soft fluidic materials.

Rajappan, Anoop↗

Flueric-controller pneumatic stepping motor system

Nutating stepping motor consists of an output rotating gear and a nutating gear. A flueric logic circuit controls the nutating motor. The complete system constitutes a reliable, open loop actuator system with inherently high output stiffness, reasonable slewing speeds and small step size.

Dustin, M. O.↗

Automatic control of liquid cooling garment by cutaneous and external auditory meatus temperatures

An automatic control apparatus for a liquid cooling garment is described that is responsive to actual physiological needs during work and rest periods of a man clothed in the liquid cooling garment. Four skin temperature readings and a reading taken at the external portion of the auditory meatus are added and used in the control signal for a temperature control valve regulating inlet water temperature for the liquid cooling garment. The control apparatus comprises electronic circuits to which the temperatures are applied as control signals and an electro-pneumatic transducer attached to the control valve.

Fulcher, C. W. G.↗

Liquid Hydrogen Regulated Low Pressure High Flow Pneumatic Panel AFT Arrow Analysis

Project Definition: Design a high flow pneumatic regulation panel to be used with helium and hydrogen. The panel will have two circuits, one for gaseous helium (GHe) supplied from the GHe Movable Storage Units (MSUs) and one for gaseous hydrogen (GH2) supplied from an existing GH2 Fill Panel. The helium will supply three legs; to existing panels and on the higher pressure leg and Simulated Flight Tanks (SFTs) for the lower pressure legs. The hydrogen line will pressurize a 33,000 gallon vacuum jacketed vessel.

Jones, Kelley, M.↗

Pneumatic oscillator Patent

Development and characteristics of fluid oscillator analog to digital converter with variable frequency controlled by signal passing through conditioning circuit

Dustin, M. O.↗

Soft Coiled Pneumatic Actuator with Integrated Length-Sensing Function for Feedback Control

SPIRA Coil actuators are formed from thin sheets of PET plastic laminated into a coil shape that unfurls like a “party horn” when inflated, while many soft actuators require large pressures to create only modest strains, SPIRA Coils can easily be designed and fabricated to extend over dramatic distances with relatively low working pressures. Internal metalized PET strips separate in the extended portion of the actuator, creating an electrical circuit with a resistance that corresponds to the actuator length. This paper presents and experimentally validates easy-to-use design models for the actuators’ self-retracting spring stiffness, its pneumatic extension force, and its internal length-sensing electrical resistance. Testing of the self-sensing capabilities demonstrates that the embedded sensor can be used to determine the actuator length with virtually no hysteresis. Feedback control with the resistance-based sensing resulted in length-control errors within 5% of the extended actuator length (i.e., 3 cm of 60 cm).

Greenwood, Jacob R. (ORCID:0000000310897854)↗

Fabrication and test of eight sets of STRAP 3 flight hardware

The development and characteristics of the Stellar Tracking Rocket Attitude Positioning (STRAP) system are discussed. The objective of the program was to produce eight sets of reliable flight hardware at a cost that was compatible with the typical sounding rocket mission. The flight system consists of: (1) the attitude control system, (2) the pneumatics systems components, and a fine guidance error sensors star tracker. The performance of the system and the areas where improvements are needed are examined. Line drawings and circuit diagrams are presented to amplify the accomplishments of the project.

Greeb, M. E.↗

Fail-safe bidirectional valve driver

Cross-coupled diodes are added to commonly used bidirectional valve driver circuit to protect circuit and power supply. Circuit may be used in systems requiring fail-safe bidirectional valve operation, particularly in chemical- and petroleum-processing control systems and computer-controlled hydraulic or pneumatic systems.

Fujimoto, H.↗

Pulse width-pulse rate modulator

Attitude control system designed for rockets regulates duty cycle of pneumatic valves so less fuel is required. Operation time of each valve is directly proportional to error signal and the dead band about a null is controlled by independently adjustable threshold circuits.

Cooke, W. A.↗

An investigation to determine the producibility of a 3-D braider and bias direction weaving loom

The development of prototype machines for the production of generalized braid patterns is described. Mechanical operating principles and control strategies are presented for two prototype machines which were fabricated and evaluated. Both machines represent advances over current techniques for forming composite material preforms by enabling near ideal control of fiber orientation. Furthermore, they overcome both the lack of general control of produced fiber architectures and the complexity of other weaving processes that were produced for the same purpose. One prototype, the modified Farley braider, consists of an array of turntables which can be rotated 90 degrees and returned; hence, they can form tracks in the x and y axis. Yarn ends are transported about the surface formed by the turntables using motorized tractors. These tractors are controlled using an optical link with a control circuit and host computer. The tractors are powered through electrical contact with the turntables. The necessary relative motions are produced by a series of linear tractor moves combined with a sequence of turntable rotations. The movement of the tractors about the surface causes the yarns to produce the desired braiding pattern. The second device, the shuttle plate braider, consists of a braiding surface formed by an array of square elements, each separated from its neighbor by a gap. Beneath this surface lies a shuttle plate, which reciprocates first in one axis and then in the other. As this movement takes place, yarn carrying shuttles engage and disengage the plate by means of solenoid activated pins. By selective engagement and disengagement, the shuttles can move the yarn ends in any desired pattern, forming the desired braid. Control power, and control signals, are transmitted from the electronic interface circuit and host computer, via the braiding surface through electrical contact with the shuttles. Motive power is proved to the shuttles by motion of the shuttle plate, which is passively driven using pneumatic rams. Each shuttle is a simple device that uses only a solenoid to engage the plate and is a simple device that uses only a solenoid to engage the plate and is independently controllable. When compared with each other, the modified Farley braider has the advantage of speed, and the shuttle plate braider the advantage of mechanical control and simplicity.

Huey, Cecil O., Jr.↗

NASA Tech Briefs, June 2009

Topics covered include: Device for Measuring Low Flow Speed in a Duct, Measuring Thermal Conductivity of a Small Insulation Sample, Alignment Jig for the Precise Measurement of THz Radiation, Autoignition Chamber for Remote Testing of Pyrotechnic Devices, Microwave Power Combiners for Signals of Arbitrary Amplitude, Synthetic Foveal Imaging Technology, Airborne Antenna System for Minimum-Cycle-Slip GPS Reception, Improved Starting Materials for Back-Illuminated Imagers, Multi-Modulator for Bandwidth-Efficient Communication, Some Improvements in Utilization of Flash Memory Devices, GPS/MEMS IMU/Microprocessor Board for Navigation, T/R Multi-Chip MMIC Modules for 150 GHz, Pneumatic Haptic Interfaces, Device Acquires and Retains Rock or Ice Samples, Cryogenic Feedthrough Test Rig, Improved Assembly for Gas Shielding During Welding or Brazing, Two-Step Plasma Process for Cleaning Indium Bonding Bumps, Tool for Crimping Flexible Circuit Leads, Yb14MnSb11 as a High-Efficiency Thermoelectric Material, Polyimide-Foam/Aerogel Composites for Thermal Insulation, Converting CSV Files to RKSML Files, Service Management Database for DSN Equipment, Chemochromic Hydrogen Leak Detectors, Compatibility of Segments of Thermoelectric Generators, Complementary Barrier Infrared Detector, JPL Greenland Moulin Exploration Probe, Ultra-Lightweight Self-Deployable Nanocomposite Structure for Habitat Applications, and Room-Temperature Ionic Liquids for Electrochemical Capacitors.

Source record↗

Real-Time Seismic System for Monitoring, Imaging, and Characterization (RT-SEISMIC)

The goal of this Laboratory Directed Research and Development (LDRD) project was to develop a borehole seismic source and sensor array to enable real-time seismic imaging at scales and conditions relevant to the energy industry including both fossil-energy and geothermal. In FY21 and FY22, we designed, built, and tested both a prototype impulse source module for generating seismic energy and a sensing module for recording ground motions generated by the source module array. A pneumatically driven vibratory source was also designed. The source modules were fabricated with all high temperature components and the team has worked to incorporate the current RT-SEISMIC electronics design into a commercially available, high temperature silicon-on-insulator chip integrated circuit. Several issues were identified during fabrication and lab testing that led to redesign of several system components and subsequent retesting. The final round of testing showed that while metal/graphite-based seals worked quite well for static seals, they were unable to provide an adequate gas seal for dynamic, reciprocating part movements which necessitated a final redesign using Kalrez. This change will result in a continuous temperature rating of approximately 275 degrees C for the system. While a field test of the RT-SEISMIC system was targeted in FY22, due to the extended lab testing and redesign efforts, field testing was not achieved. As a result of this LDRD investment, several sponsors have expressed interest in RT-SEISMIC and we expect to continue towards a field demonstration of the full system in the future.

58 GEOSCIENCES↗