High temperature thermoelectric properties of SrTiO3 under controlled pO2.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
A number of investigators have used chemical profiles of paleosols to reconstruct the evolution of atmospheric oxygen levels during the course of Earth history (Holland, 1984, 1994; Kirkham and Roscoe, 1993; Ohmoto, 1996). Over the past decade Holland and his co-workers have examined reported paleosols from six localities that formed between 2.75 and 0.45 Ga. They have found that the chemical profiles of these paleosols are consistent with a dramatic change in atmospheric PO2 between 2.2 and 2.0 Ga from < or = 0.002 to > or = 0.03 atm (Holland, 1994). Ohmoto (1996) examined chemical data from twelve reported paleosols ranging in age from 2.9 to 1.8 Ga. He concluded that these chemical profiles indicate that atmospheric PO2 has not changed significantly during the past 3.0 Ga. We seek to resolve the conflict between these reconstructions through a broader examination of the paleosol literature, both to determine which reported paleosols can be definitively identified as such and to determine what these definite paleosols tell us about atmospheric evolution. We here review reports describing over 50 proposed paleosols, all but two are older than 1.7 Ga. Our review indicates that 15 of these reported paleosols can be definitively identified as ancient soils. The behavior of iron uring the formation of these 15 paleosols provides both qualitative and semiquantitative information about the evolution of the redox state of the atmosphere. Every definitely identified pre-2.44 Ga paleosol suffered significant Fe loss during weathering. This loss indicates that atmospheric PO2 was always less than about 5 x l0(-4) atm prior to 2.44 Ga. Analysis of the Hokkalampi paleosol (2.44-2.2 Ga) (Marmo, 1992) and the Ville Marie paleosol (2.38-2.215 Ga) (Rainbird, Nesbitt, and Donaldson, 1990) yield ambiguous results regarding atmospheric PO2. Loss of Fe during the weathering of the 2.245 to 2.203 Ga Hekpoort paleosol (Button, 1979) indicates that atmospheric PO2 was less than 8 x 10(-4) atm shortly before 2.2 Ga. The presence of red beds immediately overlying the Hokkalampi, Ville Marie, and Hekpoort paleosols suggests that by about 2.2 Ga there was an unquantified but substantial amount of oxygen in the atmosphere. Iron loss was negligible during formation of the 2.2 to 2.0 Ga Wolhaarkop (Holland and Beukes, 1990) and Drakenstein (Wiggering and Beukes, 1990) paleosols and during formation of all the later paleosols we previewed. Thus, atmospheric PO2 probably has been > or = 0.03 atm since sometime between 2.2 and 2.0 Ga.
In normal subjects, exercise widens the alveolar-arterial PO2 difference (P[A-a]O2) despite a more uniform topographic distribution of ventilation-perfusion (VA/Q) ratios. While part of the increase in P(A-a)O2 (especially during heavy exercise) is due to diffusion limitation, a considerable amount is caused by an increase in VA/Q mismatch as detected by the multiple inert gas elimination technique. Why this occurs is unknown, but circumstantial evidence suggests it may be related to interstitial pulmonary edema rather than to factors dependent on ventilation, airway gas mixing, airway muscle tone, or pulmonary vascular tone. In patients with lung disease, the gas exchange consequences of exercise are variable. Thus, arterial PO2 may increase, remain the same, or fall. In general, patients with advanced chronic obstructive pulmonary disease (COPD) or interstitial fibrosis who exercise show a fall in PO2. This is usually not due to worsening VA/Q relationships but mostly to the well-known fall in mixed venous PO2, which itself results from a relatively smaller increase in cardiac output than VO2. However, in interstitial fibrosis (but not COPD), there is good evidence that a part of the fall in PO2 on exercise is caused by alveolar-capillary diffusion limitation of O2 transport; in COPD (but not interstitial fibrosis), a frequent additional contributing factor to the hypoxemia of exercise is an inadequate ventilatory response, such that minute ventilation does not rise as much as does CO2 production or O2 uptake, causing arterial PCO2 to increase and PO2 to fall.
INTRODUCTION. Some manufacturers of reduced oxygen (O2) breathing devices claim a comparable hypobaric hypoxia (HH) training experience by providing F(sub I) O2 < 0.209 at or near sea level pressure to match the ambient O2 partial pressure (iso-pO2) of the target altitude. METHODS. Literature from investigators and manufacturers indicate that these devices may not properly account for the 47 mmHg of water vapor partial pressure that reduces the inspired partial pressure of O2 (P(sub I) O2). Nor do they account for the complex reality of alveolar gas composition as defined by the Alveolar Gas Equation. In essence, by providing iso-pO2 conditions for normobaric hypoxia (NH) as for HH exposures the devices ignore P(sub A)O2 and P(sub A)CO2 as more direct agents to induce signs and symptoms of hypoxia during acute training exposures. RESULTS. There is not a sufficient integrated physiological understanding of the determinants of P(sub A)O2 and P(sub A)CO2 under acute NH and HH given the same hypoxic pO2 to claim a device that provides isohypoxia. Isohypoxia is defined as the same distribution of hypoxia signs and symptoms under any circumstances of equivalent hypoxic dose, and hypoxic pO2 is an incomplete hypoxic dose. Some devices that claim an equivalent HH experience under NH conditions significantly overestimate the HH condition, especially when simulating altitudes above 10,000 feet (3,048 m). CONCLUSIONS. At best, the claim should be that the devices provide an approximate HH experience since they only duplicate the ambient pO2 at sea level as at altitude (iso-pO2 machines). An approach to reduce the overestimation is to at least provide machines that create the same P(sub I)O2 (iso-P(sub I)O2 machines) conditions at sea level as at the target altitude, a simple software upgrade.
Purpose: Cherenkov radiation is created during external beam radiation therapy that can excite phosphorescence in tissue from oxygen-sensitive, bio-compatible probes. Utilizing the known spatial information of the treatment plan with directed multiple beam angles, Cherenkov Excited Phosphorescence Oxygen (CEPhOx) imaging was realized from the reconstructions of Cherenkov excited phosphorescence lifetime. Methods: Platinum(II)-G4 (PtG4) was used as the oxygen-sensitive phosphorescent probe and added to a oxygenated cylindrical liquid phantom with a oxygenated/deoxygenated cylindrical anomaly. Cherenkov excited phosphorescence was imaged using a time-gated ICCD camera temporallysynchronized to the LINAC pulse output. Lifetime reconstruction was carried out in NIRFAST software. Multiple angles of the incident radiation beam was combined with the location of the prescribed treatment volume (PTV) to improve the tomographic recovery as a function of location. The tissue partial pressure of oxygen (pO2) in the background and PTV was calculated based on the recovered lifetime distribution and Stern-Volmer equation. Additionally a simulation study was performed to examine the accuracy of this technique in the setting of a human brain tumor. Results: Region-based pO2 values in the oxygenated background and oxygenated/deoxygenated PTV were correctly recovered, with the deoxygenated anomaly (15.4 mmHg) easily distinguished from the oxygenated background (143 mmHg). The data acquisition time could be achieved within the normal irradiation time for a human fractionated plan. The simulations indicated that CEPhOx would be a sufficient to sample tumor pO2 sensing from tumors which are larger than 2cm in diameter or within 23mm depth from the surface. Conclusion: CEPhOx could be a novel imaging tool for pO2 assessment during external radiation beam therapy. It is minimally invasive and should work within the established treatment plan of radiation therapy with multiple beams in situations where tumor pO2 measurement is a pertinent radiotherapy efficiency and dosimetric need.
A systematic study of the chemical interaction of Ba{sub 2}YCu{sub 3}O{sub 6+y} and Gd{sub 3}NbO{sub 7} was conducted under two processing conditions: purified air (21% p{sub o{sub 2}}), and 100 Pa p{sub o{sub 2}} (0.1% p{sub o{sub 2}}). Phases present along the pseudo-binary join Ba{sub 2}YCu{sub 3}O{sub 6z} and Gd{sub 3}NbO{sub 7} were found to be in two five-phase volumes within the BaO-1/2 Y{sub 2}O{sub 3}-1/2 Gd{sub 2}O{sub 3}-Nb{sub 2}O{sub 5}-CuO{sub y} system. Three common phases that are present in all samples are (Y,Gd){sub 2}Cu{sub 2}O{sub 5}, Ba(Y,Gd){sub 2}CuO{sub 5} and Cu{sub 2}O or CuO (depending on the processing conditions). The assemblies of phases can be categorized in three regions, with Ba{sub 2}YCu{sub 3}O{sub 6+y}: Gd{sub 3}NbO{sub 7} ratios of (I)<5.5:4.5; (II)=5.5:4.5; and (III)>5.5:4.5. The lowest melting temperature of the system was determined to be {approx}938 deg. C in air, and 850 deg. C at 100 Pa p{sub o{sub 2}}. Structure determinations of two selected phases, Ba{sub 2}(Gd{sub x}Y{sub 1-x})NbO{sub 6} (Fm3-barm, No. 225), and (Gd{sub x}Y{sub 3-x})NbO{sub 7} (C222{sub 1}, No. 20 and Ccmm, No. 63), were completed using the X-ray Rietveld refinement technique. Reference X-ray powder diffraction patterns for selected phases of Ba{sub 2}(Gd{sub x}Y{sub 1-x})NbO{sub 6} (x=0.2, 0.4, 0.6, and 0.8) and (Gd{sub x}Y{sub 3-x})NbO{sub 7} (x=0.6, 1.2, 1.8, 2.4 and 3) have been prepared for inclusion in the Powder Diffraction File (PDF). - Graphical abstract: Crystal structure for (Gd{sub x}Y{sub 3-x})NbO{sub 7} showing the partial layered feature. The alternate stacking of distorted NbO{sub 6} octahedra and (Gd,Y)O{sub 7} polyhedra are illustrated. The (Gd,Y)O{sub 8} polyhedra are omitted for clarity.
The chemical stability of lanthanide nickelates Ln{sub 2}NiO{sub 4+δ} (Ln=La, Pr or Nd) has been studied in the temperature range 25–1300 °C, either in air or at low pO{sub 2} (down to 10{sup −4} atm). Thermal gravimetry analysis (TGA) measurements coupled with X-ray diffraction (XRD) characterization have shown that all compounds retain their K{sub 2}NiF{sub 4}-type structure in these conditions, while remaining over-stoichiometric in oxygen up to 1000 °C. Only Nd{sub 2}NiO{sub 4+δ} starts to decompose into Nd{sub 2}O{sub 3} and NiO above 1000 °C, at pO{sub 2}=10{sup −4} atm. In addition, a careful analysis of the lanthanide nickelates structural features has been performed by in situ XRD, as a function of temperature and pO{sub 2}. For all compounds, a structural transition has been always observed in the temperature range 200–400 °C, in air or at pO{sub 2}=10{sup −4} atm. In addition, their cell volume did not vary upon the variation of the oxygen partial pressure. Therefore, these materials do not exhibit a chemical expansion in these conditions, which is beneficial for a fuel cell application as cathode layers. Additional dilatometry measurements have revealed that a temperature as high as 950 °C for Pr{sub 2}NiO{sub 4+δ} or 1100 °C for La{sub 2}NiO{sub 4+δ} and Nd{sub 2}NiO{sub 4+δ} has to be reached in order to begin the sintering of the material particles, which is of primary importance to obtain an efficient electronic/ionic conduction in the corresponding designed cathode layers. Besides, excellent matching was found between the thermal expansion coefficients of lanthanide nickelates and SOFC electrolytes such as 8wt% yttria stabilized zirconia (8YSZ) or Ce{sub 0.8}Gd{sub 0.2}O{sub 2−δ} (GDC), at least from 400 °C up to 1400 °C in air or up to 1200 °C at pO{sub 2}=10{sup −4} atm. - Graphical abstract: This study reports the good chemical stability of oxygen overstoichiometric Ln2NiO4+δ(Ln = La, Pr or Nd) at high temperatures (up to 1300 °C), eitherin air or at pO2down to 10-4 atm. In addition, these MSC cathode materials show a small chemical expansion as well as a good TEC compatibility with electrolyte materials (GDC or YSZ). - Highlights: • The structure of Ln2NiO4+δ compounds are studied vs. temperature and pO2 • Structural transitions are evidenced in air as well as in low pO2 atmosphere • The structural transitions do not significantly affect their TECs values • Up to 1200 °C, they show good chemical stability and no chemical expansion vs. pO2 • TECs of nickelates, 8YSZ and GDC are compared in air and in low pO2 atmosphere.
Purpose: Understanding the transient dynamics of tumor oxygenation is important when evaluating tumor-vasculature response to anti-angiogenic therapies. An imaging-based tumor-vasculature model was used to elucidate factors that affect these dynamics. Methods: Tumor growth depends on its doubling time (Td). Hypoxia increases pro-angiogenic factor (VEGF) concentration which is modeled to reduce vessel perfusion, attributing to its effect of increasing vascular permeability. Perfused vessel recruitment depends on the existing perfused vasculature, VEGF concentration and maximum VEGF concentration (VEGFmax) for vessel dysfunction. A convolution-based algorithm couples the tumor to the normal tissue vessel density (VD-nt). The parameters are benchmarked to published pre-clinical data and a sensitivity study evaluating the changes in the peak and time to peak tumor oxygenation characterizes them. The model is used to simulate changes in hypoxia and proliferation PET imaging data obtained using [Cu- 61]Cu-ATSM and [F-18]FLT respectively. Results: Td and VD-nt were found to be the most influential on peak tumor pO2 while VEGFmax was marginally influential. A +20 % change in Td, VD-nt and VEGFmax resulted in +50%, +25% and +5% increase in peak pO2. In contrast, Td was the most influential on the time to peak oxygenation with VD-nt and VEGFmax playing marginal roles. A +20% change in Td, VD-nt and VEGFmax increased the time to peak pO2 by +50%, +5% and +0%. A −20% change in the above parameters resulted in comparable decreases in the peak and time to peak pO2. Model application to the PET data was able to demonstrate the voxel-specific changes in hypoxia of the imaged tumor. Conclusion: Tumor-specific doubling time and vessel density are important parameters to be considered when evaluating hypoxia transients. While the current model simulates the oxygen dynamics of an untreated tumor, incorporation of therapeutic effects can make the model a potent tool for analyzing anti-angiogenic therapies.
Microgravity conditions have advantages of measurement of surface tension and viscosity of metallic liquids by the oscillating drop method with an electromagnetic levitation (EML) device. Thus, we are preparing the experiments of thermophysical properties measurements using the Materials-Science Laboratories ElectroMagnetic-Levitator (MSL-EML) facilities in the international Space station (ISS). Recently, it has been identified that dependence of surface tension on oxygen partial pressure (Po2) must be considered for industrial application of surface tension values. Effect of Po2 on surface tension would apparently change viscosity from the damping oscillation model. Therefore, surface tension and viscosity must be measured simultaneously in the same atmospheric conditions. Moreover, effect of the electromagnetic force (EMF) on the surface oscillations must be clarified to obtain the ideal surface oscillation because the EMF works as the external force on the oscillating liquid droplets, so extensive EMF makes apparently the viscosity values large. In our group, using the parabolic flight levitation experimental facilities (PFLEX) the effect of Po2 and external EMF on surface oscillation of levitated liquid droplets was systematically investigated for the precise measurements of surface tension and viscosity of high temperature liquids for future ISS experiments. We performed the observation of surface oscillations of levitated liquid alloys using PFLEX on board flight experiments by Gulfstream II (G-II) airplane operated by DAS. These observations were performed under the controlled Po2 and also under the suitable EMF conditions. In these experiments, we obtained the density, the viscosity and the surface tension values of liquid Cu. From these results, we discuss about as same as reported data, and also obtained the difference of surface oscillations with the change of the EMF conditions.
The effect of nickel substitution on defect chemistry, electrical properties, and dimensional stability of calcium-doped yttrium chromite was studied for use as an interconnect material in high temperature solid oxide fuel cells (SOFCs). The compositions of Y0.8Ca0.2Cr1-xNixO3±δ (x=0-0.15), prepared using the glycine nitrate process, showed single phase orthorhombic perovskite structures over a wide range of oxygen partial pressures (10^-17 atm ≤ pO2 ≤ 0.21 atm). X-ray diffraction (XRD) analysis indicated that most of the nickel ions replacing chromium ions are divalent and act as acceptor dopants, leading to a substantial increase in conductivity. In particular, the conductivity at 900 degree C in air increased from 10 S/cm to 34 S/cm with 15% nickel substitution, and an increase in charge carrier density was confirmed by Seebeck measurements. A point defect model was derived, and the relationship between electrical conductivity and oxygen partial pressure was successfully fitted into the proposed model. The defect modeling results indicated that nickel substitution improves the stability of calcium-doped yttrium chromite toward reduction and suppresses the oxygen vacancy formation, which results in significantly increased electrical conductivity in reducing environment. The electrical conductivity of Y0.8Ca0.2Cr0.85Ni0.15O3±δ at 900 degree C in reducing atmosphere (pO2=10^-17 atm) was 5.8 S/cm, which was more than an order of magnitude higher than that of Y0.8Ca0.2CrO3±δ (0.2 S/cm). Improved stability in reducing atmosphere was further confirmed by dilatometry measurements showing reduced isothermal "chemical" expansion, and the isothermal expansion in reducing atmosphere (pO2=10^-17 atm) at 900 degree C decreased from 0.07% for Y0.8Ca0.2CrO3±δ to 0.03% for Y0.8Ca0.2Cr0.85Ni0.15O3±δ. Based on these results, enhanced electrical performance and mechanical integrity is expected with nickel substitution on calcium-doped yttrium chromite in SOFC operating conditions.
Purpose: As hypoxic cells are more resistant to photon radiation, it is desirable to obtain information about the oxygen distribution in tumors prior to the radiation treatment. Noninvasive techniques are currently not able to provide reliable oxygenation maps with sufficient spatial resolution; therefore mathematical models may help to simulate microvascular architectures and the resulting oxygen distributions in the surrounding tissue. Here, the authors present a new computer model, which uses the vascular fraction of tumor voxels, in principle measurable noninvasively in vivo, as input parameter for simulating realistic PO2 histograms in tumors, assuming certain 3D vascular architectures.Methods: Oxygen distributions were calculated by solving a reaction-diffusion equation in a reference volume using the particle strength exchange method. Different types of vessel architectures as well as different degrees of vascular heterogeneities are considered. Two types of acute hypoxia (ischemic and hypoxemic) occurring additionally to diffusion-limited (chronic) hypoxia were implemented as well.Results: No statistically significant differences were observed when comparing 2D- and 3D-vessel architectures (p > 0.79 in all cases) and highly heterogeneously distributed linear vessels show good agreement, when comparing with published experimental intervessel distance distributions and PO2 histograms. It could be shown that, if information about additional acute hypoxia is available, its contribution to the hypoxic fraction (HF) can be simulated as well. Increases of 128% and 168% in the HF were obtained when representative cases of ischemic and hypoxemic acute hypoxia, respectively, were considered in the simulations.Conclusions: The presented model is able to simulate realistic microscopic oxygen distributions in tumors assuming reasonable vessel architectures and using the vascular fraction as macroscopic input parameter. The model may be used to generate PO2 histograms, which are needed as input in models predicting the radiation response of hypoxic tumors.
MgO6(PO2)2 is Zincblende, Sphalerite structured and crystallizes in the monoclinic Cm space group. The structure is zero-dimensional and consists of two magnesium;dihydroxide;tetrahydrate molecules and two PO2 clusters. In each PO2 cluster, there are two inequivalent P sites. In the first P site, P is bonded in a trigonal planar geometry to three O atoms. There is one shorter (1.46 Å) and two longer (1.53 Å) P–O bond length. In the second P site, P is bonded in a distorted trigonal non-coplanar geometry to three O atoms. There is one shorter (1.47 Å) and two longer (2.04 Å) P–O bond length. There are three inequivalent O sites. In the first O site, O is bonded in a single-bond geometry to one P atom. In the second O site, O is bonded in a single-bond geometry to one P atom. In the third O site, O is bonded in an L-shaped geometry to two P atoms.
Oxygen tracer diffusion coefficients are determined in single-crystal alumina samples with differing dopant levels using the gas-exchange technique. The diffusion direction is parallel to the c-axis and the ambient PO2 is 1 atm (100,000 Pa) for all experiments except a single run with a low PO2, approximately 10 to the -15th atm (10 to the -10th Pa) produced by a CO/CO2 mixture. The diffusion is insensitive to both impurities and ambient PO2. The insensitivities are discussed in terms of point-defect clustering. Prior tracer studies are compared and discussed.
To quantify the relative contributions of convective and peripheral diffusive components of O2 transport to the increase in leg O2 uptake (VO2leg) at maximum O2 uptake (VO2max) after 9 wk of endurance training, 12 sedentary subjects (age 21.8 +/- 3.4 yr, VO2max 36.9 +/- 5.9 ml.min-1.kg-1) were studied. VO2max, leg blood flow (Qleg), and arterial and femoral venous PO2, and thus VO2leg, were measured while the subjects breathed room air, 15% O2, and 12% O2. The sequence of the three inspirates was balanced. After training, VO2max and VO2leg increased at each inspired O2 concentration [FIO2; mean over the 3 FIO2 values 25.2 +/- 17.8 and 36.5 +/- 33% (SD), respectively]. Before training, VO2leg and mean capillary PO2 were linearly related through the origin during hypoxia but not during room air breathing, suggesting that, at 21% O2, VO2max was not limited by O2 supply. After training, VO2leg and mean capillary PO2 at each FIO2 fell along a straight line with zero intercept, just as in athletes (Roca et al. J. Appl. Physiol. 67: 291-299, 1989). Calculated muscle O2 diffusing capacity (DO2) rose 34% while Qleg increased 19%. The relatively greater rise in DO2 increased the DO2/Qleg, which led to 9.9% greater O2 extraction. By numerical analysis, the increase in Qleg alone (constant DO2) would have raised VO2leg by 35 ml/min (mean), but that of DO2 (constant Qleg) would have increased VO2leg by 85 ml/min, more than twice as much. The sum of these individual effects (120 ml/min) was less (P = 0.013) than the observed rise of 164 ml/min (mean). This synergism (explained by the increase in DO2/Qleg) seems to be an important contribution to increases in VO2max with training.
Patterned cathodes of calcium-doped lanthanum manganite (LCM) were fabricated on polycrystalline yttria-stabilized zirconia (YSZ) substrates by RF magnetron sputtering and photolithographic techniques. Samples were generated with a constant electrode/electrolyte contact area but different three phase boundary (TPB) lengths (lTPB's). Electrochemical impedance spectroscopy (EIS) was performed in the oxygen partial pressure (pO2) and temperature range of 10-3 atm to 1.00 atm and 600-800 C respectively. The area specific polarization resistance, Rp, was found to scale linearly with the inverse of lTPB, suggesting that the TPB is the active region for oxygen reduction. The resistivity decreased with increased temperature and pO2 and showed an activation energy of 1.17 +/- 0.03 eV.