Photodiode Preamplifier for Laser Ranging With Weak Signals

An improved preamplifier circuit has been designed for processing the output of an avalanche photodiode (APD) that is used in a high-resolution laser ranging system to detect laser pulses returning from a target. The improved circuit stands in contrast to prior such circuits in which the APD output current pulses are made to pass, variously, through wide-band or narrow-band load networks before preamplification. A major disadvantage of the prior wide-band load networks is that they are highly susceptible to noise, which degrades timing resolution. A major disadvantage of the prior narrow-band load networks is that they make it difficult to sample the amplitudes of the narrow laser pulses ordinarily used in ranging. In the improved circuit, a load resistor is connected to the APD output and its value is chosen so that the time constant defined by this resistance and the APD capacitance is large, relative to the duration of a laser pulse. The APD capacitance becomes initially charged by the pulse of current generated by a return laser pulse, so that the rise time of the load-network output is comparable to the duration of the return pulse. Thus, the load-network output is characterized by a fast-rising leading edge, which is necessary for accurate pulse timing. On the other hand, the resistance-capacitance combination constitutes a lowpass filter, which helps to suppress noise. The long time constant causes the load network output pulse to have a long shallow-sloping trailing edge, which makes it easy to sample the amplitude of the return pulse. The output of the load network is fed to a low-noise, wide-band amplifier. The amplifier must be a wide-band one in order to preserve the sharp pulse rise for timing. The suppression of noise and the use of a low-noise amplifier enable the ranging system to detect relatively weak return pulses.

Abramovici, Alexander

Electrometer preamplifier has drift correction feedback

Negative feedback circuit corrects output drift in an electrometer. The negative feedback is used in the no signal state to maintain the output level at zero reference. Drift voltage storage in the signal on state is also used to provide a drift-free readout.

Labarthe, L. C.

The 1.06 micrometer avalanche photodiode detectors with integrated circuit preamplifiers

The development of a complete solid state 1.06 micron optical receiver which can be used in optical communications at data rates approaching 1.5 Gb/s, or in other applications requiring sensitive, short-pulse detection, is reported. This work entailed both the development of a new type of heterojunction 3-5 semiconductor alloy avalanche photodiode and an extremely charge-sensitive wideband low-noise preamp design making use of GaAs Schottky barrier-gate field effect transistors.

Eden, R. C.

Sensitive method for characterizing liquid helium cooled preamplifier feedback resistors

It is pointed out that the simple and traditional method of measuring resistance using an electrometer is ineffective since it is limited to a narrow and nonrepresentative range of terminal voltages. The present investigation is concerned with a resistor measurement technique which was developed to select and calibrate the Transimpedance Mode Amplifier (TIA) load resistors on the Infrared Astronomical Satellite (IRAS) for the wide variety of time and voltage varying signals which will be processed during the flight. The developed method has great versatility and power, and makes it possible to measure the varied and complex responses of nonideal feedback resistors to IR photo-detector currents. When employed with a stable input coupling capacitor, and a narrow band RMS voltmeter, the five input waveforms thouroughly test and calibrate all the features of interest in a load resistor and its associated TIA circuitry.

Smeins, L. G.

X-band preamplifier filter

A low-loss bandstop filter designed and developed for the Deep Space Network's 34-meter high-efficiency antennas is described. The filter is used for protection of the X-band traveling wave masers from the 20-kW transmitter signal. A combination of empirical and theoretical techniques was employed as well as computer simulation to verify the design before fabrication.

Manshadi, F.

Matching Network For Microwave Preamplifier

Stable operation and broadband, optimum noise performance achieved. Amplifier designed by new method of matching input impedance for optimum noise figure and stability. Output more nearly constant over wider frequency range.

Sifri, Jack D.

Infrared and visible detector electronics for the Infrared Astronomical Satellite (IRAS)

The paper describes the detectors, preamplifiers, and processing electronics; the system characterization test methods and results; and the performance of the detectors and electronics during the first month of on-orbit operation of the IRAS telescope. The Focal Plane Array (FPA) consists of 62 IR channels and 8 visible channels operating at 2.5 K. The IR detectors are grouped in eight 7 or 8 channel staggered linear subarrays with shared bias voltage; the visible detectors are grouped in two 4 channel skewed arrays, also with shared bias. Each channel detector is dc coupled to a TIA preamplifier through a very low power thermally isolated JFET source follower operating at about 65 K within the FPA housing. The visible channel detectors are ac coupled to TIA preamplifiers and signal chain electronics using MOSFET source followers operating at about 2.5 K within the FPA housing. The detectors, preamplifiers, analog electronics, and grounding are discussed as they evolved and were implemented during FPA retrofit, telescope integration, and preparation for launch.

Langford, D. L.

Binary selectable detector holdoff circuit: Design, testing, and application

A very high speed switching circuit, part of a laser radar data acquisition system, has been designed and tested. The primary function of this circuit was to provide computer controlled switching of photodiode detector preamplifier power supply voltages, typically less than plus or minus 20 volts, in approximately 10 nanoseconds. Thus, in actual use, detector and/or detector preamplifier damage can be avoided as a result of sudden extremely large values of backscattered radiation being detected, such as might be due to short range, very thin atmospheric dust layers. Switching of the power supply voltages was chosen over direct switching the photodiode detector input to the preamplifier, based on system noise considerations. Also, the circuit provides a synchronized trigger pulse output for triggering devices such as the Biomation Model 8100 100 MHz analog to digital converter.

Kadrmas, K. A.

Low-noise extended-frequency response with cooled silicon photodiodes

It is shown that a substantial reduction in internal noise generated by the photodiode and the preamplifier can be produced by a modest cooling of the components and by optimization of preamplifier design. With this reduction the silicon detectors can, in the SNR range of 5 or greater, produce better performance than photon-noise-limited photomultipliers. The circuit noise and frequency response model suggested by Goranson and Skipper (1974) is expanded to include the effects of frequency dependent FET voltage noise and FET load resistance noise. The modeling of the photodiode and preamplifier is described and the noise characteristics of a 0.01 Hz to 100 kHz bandwidth detector/amplifier channel are evaluated.

Neiswander, R. S.

Brief characterization of germanium junction field effect transistors (FETs) at 77, 4, and 1.8 K

In the case of modern infrared focal planes, one of the major problems is related to the noise contribution of the cooled, impedance-matching device used as the preamplifier stage in the detector electronics system. An ideal preamp device should have the low-noise advantages of a buried-channel device and operate isothermally with the low-temperature detector array. The Ge JFET might provide this ideal device. A testing program with Ge JFETs is discussed. It is concluded that germanium JFETs offer an attractive alternative for cryogenic preamplifier designs. They operate well with high transconductance and low noise at LHe temperatures. It is believed that these devices point the way for the development of large, integrated-array, long wavelength, infrared focal planes which incorporate germanium detectors, germanium load resistors, and germanium preamplifiers within the same monolithic structure.

Arentz, R. F.

Performance measurement results for a 220 Mbps QPPM optical communication receiver with an EG/G Slik APD

The performance of a 220 Mbps quaternary pulse position modulation (QPPM) optical communication receiver with a 'Slik' silicon avalanche photodiode (APD) and a wideband transimpedance preamplifier in a small hybrid circuit module was measured. The receiver performance had been poor due to the lack of a wideband and low noise transimpedance preamplifier. With the new APB preamplifier module, the receiver achieved a bit error rate (BER) of 10 exp -6 at an average received input optical signal power of 4.2 nW, which corresponds to an average of 80 received (incident) signal photons per information bit.

Davidson, Frederic M.

Low-Cutoff, High-Pass Digital Filtering of Neural Signals

The figure depicts the major functional blocks of a system, now undergoing development, for conditioning neural signals acquired by electrodes implanted in a brain. The overall functions to be performed by this system can be summarized as preamplification, multiplexing, digitization, and high-pass filtering. Other systems under development for recording neural signals typically contain resistor-capacitor analog low-pass filters characterized by cutoff frequencies in the vicinity of 100 Hz. In the application for which this system is being developed, there is a requirement for a cutoff frequency of 5 Hz. Because the resistors needed to obtain such a low cutoff frequency would be impractically large, it was decided to perform low-pass filtering by use of digital rather than analog circuitry. In addition, it was decided to timemultiplex the digitized signals from the multiple input channels into a single stream of data in a single output channel. The signal in each input channel is first processed by a preamplifier having a voltage gain of approximately 50. Embedded in each preamplifier is a low-pass anti-aliasing filter having a cutoff frequency of approximately 10 kHz. The anti-aliasing filters make it possible to couple the outputs of the preamplifiers to the input ports of a multiplexer. The output of the multiplexer is a single stream of time-multiplexed samples of analog signals. This stream is processed by a main differential amplifier, the output of which is sent to an analog-to-digital converter (ADC). The output of the ADC is sent to a digital signal processor (DSP).

Mojarradi,Mohammad

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)

Log amplifier instrument measures physiological biopotentials over wide dynamic range

To record biopotentials with extreme dynamic ranges, biopotential inputs are capacitatively coupled to a miniature, low power, solid-state signal conditioner consisting of a two-stage differential preamplifier that has a low noise figure. The ouput of the preamplifier uses diodes to provide an overall gain which is nearly logarithmic.

Kado, R. T.

Design and development of solid state detector for SCADS

Solid state detector technology was applied to the fabrication and testing of cadmium sulfide and silicon narrow slit detector/preamplifier subassemblies. Fabrication of the silicon detector and the cadmium sulfide detectors was accomplished by utilizing cadmium sulfide cells and silicon cells. Fabrication of the preamplifiers for both silicon and cadmium sulfide slit type detectors was also carried out. The design of these preamplifiers was adjusted to ascertain that the limiting noise source of the detector/preamplifier subassembly is the detector and the input cable.