Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROMPT GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

THE PHOTOSPHERIC RADIATION MODEL FOR THE PROMPT EMISSION OF GAMMA-RAY BURSTS: INTERPRETING FOUR OBSERVED CORRELATIONS

We show that the empirical E{sub p}-L, {Gamma}-L, E{sub p}-{Gamma}, and {eta}-bar{sub {gamma}}-E{sub p} correlations (where L is the time-averaged luminosity of the prompt emission, E{sub p} is the spectral peak energy, {Gamma} is the bulk Lorentz factor, and {eta}-bar{sub {gamma}} is the emission efficiency of gamma-ray bursts, GRBs) are well consistent with the relations between the analogous parameters predicted in the photospheric radiation model of the prompt emission of GRBs. The time-resolved thermal radiation of GRB 090902B does follow the E{sub p}-L and {Gamma}-L correlations. A reliable interpretation of the four correlations in alternative models is still lacking. These may point toward a photospheric origin of prompt emission of some GRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

The prompt GRB high energy emission from internal shocks: synchrotron vs inverse Compton component

We performed a detailed calculation of gamma-ray burst (GRB) prompt emission in the framework of the internal shock scenario, focusing on the high energy (GeV) bands. In order to follow the evolution of the ultrarelativistic inhomogeneous wind, we combined a model for the dynamics of internal shocks with a detailed calculation of the radiative processes occurring in the shocked medium. We present the resulting synthetic GRB light curves and spectra. We show the spectral evolution that can be expected for different sets of microphysics parameters and parameters of the dynamical evolution, and how the relative importance of synchrotron and inverse Compton components is varying during a burst.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of Insulation Compaction in the Cryogenic Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Th ere is evidence that some of the perlite has compacted over time, com promising the thermal performance and possibly also structural integr ity of the tanks. Therefore an Non-destructive Testing (NDT) method for measuring the perlite density or void fraction is urgently needed. Methods based on neutrons are good candidates because they can readil y penetrate through the 1.75 cm outer steel shell and through the ent ire 120 cm thickness of the perlite zone. Neutrons interact with the nuclei of materials to produce characteristic gamma rays which are the n detected. The gamma ray signal strength is proportional to the atom ic number density. Consequently, if the perlite is compacted then the count rates in the individual peaks in the gamma ray spectrum will i ncrease. Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. With commercially available portable neutron generators it is possible to produce simul taneously fluxes of neutrons in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scatt ering which is sensitive to Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA) and this is sensitive to Si, AI, Na, Kand H. Thus the two energy ranges produce complementary information. The R&D program has three phases: numerical simulations of neutron and gamma ray transport with MCNP s oftware, evaluation of the system in the laboratory on test articles and finally mapping of the perlite density in the cryogenic tanks at KSC. The preliminary MCNP calculations have shown that the fast/therma l neutron NDT method is capable of distinguishing between expanded an d compacted perlite with excellent statistics.

Livingston, R. A.↗

The cyclotron laboratory and the RFQ accelerator in Bern

Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target

Purpose: In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on-line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here. Methods: We present the measurements of the secondary radiation generated by He, C and O beams impinging on a beam stopping PMMA target. The data has been collected at the Heidelberg Ionbeam Therapy center (HIT), where several millions of collisions were recorded at different energies, relevant for therapeutical applications. Results: The experimental setup, as well as the analysis strategies will be reviewed. The detected particle fluxes as a function of the primary beam energy and the emission angle with respect to the beam direction will be presented and compared to the results of other available measurements. In addition, the energy spectra and emission shapes of charged secondary particles will be shown and discussed in the context of the primary beam range monitoring technique that is being developed by the ARPG collaboration, within the INSIDE project funded by the Italian research ministry. The implications for dose monitoring applications will be discussed, in the context of the current (or planned) state-of- the-art detector solutions. Conclusion: The characterization of the radiation produced by 12C, 4He and 16O beams fully supports the feasibility of on-line range monitoring in the clinical practice of CPT by means of secondary particles detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calorimeter Upgrade to the PHENIX Forward Spectrometers

The forward calorimeter upgrade to the PHENIX forward spectrometers aims to add capabilities at high rapidity (0.9<eta<3.0) in order to significantly extend the kinematic reach of PHENIX's DELTAG measurement for the prompt photon and photon-jet channels, study transverse spin physics through forward hadron asymmetries, study nucleon structure in nuclei at high parton densities in p+A collisions through the measurement of photons and neutral pions in the forward region, and enhance our quark and anti-quark spin measurements via W-production by providing an isolation cut and possibly providing an electron measurement at forward rapidities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

What is the radiative process of the prompt phase of Gamma Ray Bursts?

Despite the dramatic improvement of our knowledge of the phenomenology of Gamma Ray Bursts, we still do not know several fundamental aspects of their physics. One of the puzzles concerns the nature of the radiative process originating the prompt phase radiation. Although the synchrotron process qualifies itself as a natural candidate, it faces severe problems, and many efforts have been done looking for alternatives. These, however, suffer from other problems, and there is no general consensus yet on a specific radiation mechanism.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Prompt Gamma Neutron Activation Analysis Facility at ICN-Pitesti

PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performance of INAA method. A facility has been developed at Institute for Nuclear Research-Pitesti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA-facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system.Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: {phi}{sub scd} = 1.10{sup 6} n/cm{sup 2}/s with a cadmium ratio of:80.The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90 deg. with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Cargo Inspection System for Special Nuclear Material (SNM) Based on Associated Particle Neutron Generators and Liquid-Kr Detectors

A feasibility analysis is presented of a cargo inspection system based on neutron-induced fission followed by the coincident detection of multiple prompt fission gamma rays as a signature of Special Nuclear Material (SNM). The system does not require gamma ray spectroscopy and would be capable of distinguishing U-238 from U-235 using the ratio of signals from two modes of detection: thermal neutron capture induced fission and fast neutron-induced fission. The system utilizes two deuterium-tritium (DT) associated particle neutron generators, each capable of 10{sup 9} neutrons/s at 14.1 MeV, with sub-nanosecond timing resolution ZnO:Ga alpha detectors. The expected {approx}1 MeV prompt gamma rays are detected using liquid krypton (LKr) detectors with sub-nanosecond timing resolution ({approx}600 ps) and high detection efficiency. The expected SNM signal and randomly correlated background rates are discussed using Monte Carlo N-Particle (MCNP) code.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Comparison of Neutron-Based Non-Destructive Assessment Methods for Chemical Warfare Material and High Explosives

Prompt Gamma Neutron Activation Analysis (PGNAA) systems employ neutrons as a probe to interrogate items, e.g. chemical warfare materiel-filled munitions. The choice of a neutron source in field-portable systems is determined by its ability to excite nuclei of interest, operational concerns such as radiological safety and ease-of-use, and cost. Idaho National Laboratory's PINS Chemical Assay System has traditionally used a {sup 252}Cf isotopic neutron source, but recently a deuterium-tritium (DT) electronic neutron generator (ENG) has been tested as an alternate neutron source. This paper presents the results of using both of these neutron sources to interrogate chemical warfare materiel (CWM) and high explosive (HE) filled munitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New probes of GRB prompt emission properties using wide-band spectroscopy by Suzaku Wide-band All-sky Monitor

Although the afterglow observations in HETE-2 and Swift era have revealed a lot of afterglow properties of gamma-ray bursts (GRBs), we still have poor understanding of the prompt gamma-ray emission, such as the emission mechanism of the prompt emission and differences between short and long duration GRBs. We have observed many prompt emission of GRBs by Suzaku Wide-band All-sky Monitor in wide energy range of 50-5000 keV, with very large effective area of 400 cm{sup 2} even at 1 MeV. Furthermore, a combination of the Suzaku/WAM and Swift data provides us not only wider energy range of 15-5000 keV but also redshift information even for some short GRBs. Thanks to these information, we can firstly investigate an intrinsic correlation for short GRBs like E{sub peak}-L{sub iso} relation, and we can derive the same type of relation for time-resolved spectra of long GRBs in finer time-scale with higher statistics than ever before. These results could be used to discuss the differences between short and long GRBs, and our time-resolved E{sub peak}-L{sub iso} relation also could be used as both more appropriate redshift indicator and new probe of the fireball dynamics.

79 ASTRONOMY AND ASTROPHYSICS↗

Is the Rapid Decay Phase from High Latitude Emission?

There is good observationnal evidence that the Steep Decay Phase (SDP) that is observed in most Swift GRBs is the tail of the prompt emission. The most popular model to explain the SDP is Hight Latitude Emission (HLE). Many models for the prompt emission give rise to HLE, like the popular internal shocks (IS) model, but some models do not, such as sporadic magnetic reconnection events. Knowing if the SDP is consistent with HLE would thus help distinguish between different prompt emission models. In order to test this, we model the prompt emission (and its tail) as the sum of independent pulses (and their tails). A single pulse is modeled as emission arising from an ultra-relativistic thin spherical expanding shell. We obtain analytic expressions for the flux in the IS model with a Band function spectrum. We find that in this framework the observed spectrum is also a Band function, and naturally softens with time. The decay of the SDP is initially dominated by the tail of the last pulse, but other pulses can dominate later. Modeling several overlapping pulses as a single broader pulse would overestimates the SDP flux. One should thus be careful when testing the HLE.

79 ASTRONOMY AND ASTROPHYSICS↗

Fusion product diagnostics planned for Large Helical Device deuterium experiment

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt {gamma}-ray diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamical Dipole Mode in Heavy-Ion Fusion-Evaporation and Fission Reactions in the {sup 192}Pb Mass Region

The prompt {gamma}-ray emission related with the dynamical dipole mode decay was investigated in the {sup 192}Pb mass region by means of the {sup 40}Ca+{sup 152}Sm and {sup 48}Ca+{sup 144}Sm fusion-evaporation and fission reactions at E{sub lab} = 11 and 10.1 MeV/nucleon, respectively. The two reactions populate, through entrance channel having different charge asymmetries, the {sup 192}Pb compound nucleus at an excitation energy of 236 MeV with identical spin distribution. Preliminary results of this experiment show that the dynamical dipole mode survives in collisions involving heavier mass reaction partners than those studied previously. As a fast cooling mechanism on the fusion path, the prompt dipole {gamma} radiation could be of interest for the synthesis of super-heavy elements through ''hot'' fusion reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beams (LAMFI-USP) by the {sup 10}B(p,αγ({sup 7}Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 10{sup 16} at/cm{sup 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MAGNETIC STRUCTURES IN GAMMA-RAY BURST JETS PROBED BY GAMMA-RAY POLARIZATION

We report polarization measurements in two prompt emissions of gamma-ray bursts, GRB 110301A and GRB 110721A, observed with the gamma-ray burst polarimeter (GAP) on borad the IKAROS solar sail mission. We detected linear polarization signals from each burst with polarization degree of {Pi} = 70 {+-} 22% with statistical significance of 3.7{sigma} for GRB 110301A, and {Pi} = 84{sup +16}{sub -28}% with 3.3{sigma} confidence level for GRB 110721A. We did not detect any significant change of polarization angle. These two events had shorter durations and dimmer brightness compared with GRB 100826A, which showed a significant change of polarization angle, as reported in Yonetoku et al. Synchrotron emission model can be consistent with the data of the three GRBs, while the photospheric quasi-thermal emission model is not favored. We suggest that magnetic field structures in the emission region are globally ordered fields advected from the central engine.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid Enrichment Verification Array: Module Characterization Studies

The work presented in this report is focused on the characterization and refinement of the Hybrid Enrichment Verification Array (HEVA) approach, which combines the traditional 186-keV 235 U signature with high-energy prompt gamma rays from neutron capture in the detector and surrounding collimator material, to determine the relative enrichment and 235 U mass of the cylinder. The design of the HEVA modules (hardware and software) deployed in the current field trial builds on over seven years of study and evolution by PNNL, and consists of a ø3''×3'' NaI(Tl) scintillator coupled to an Osprey digital multi-channel analyzer tube base from Canberra. The core of the HEVA methodology, the high-energy prompt gamma-ray signature, serves as an indirect method for the measurement of total neutron emission from the cylinder. A method for measuring the intrinsic efficiency of this “non-traditional” neutron signature and the results from a benchmark experiment are presented. Also discussed are potential perturbing effects on the non-traditional signature, including short-lived activation of materials in the HEVA module. Modeling and empirical results are presented to demonstrate that such effects are expected to be negligible for the envisioned implementation scenario. In comparison to previous versions, the new design boosts the high-energy prompt gamma-ray signature, provides more flexible and effective collimation, and improves count-rate management via commercially available pulse-processing electronics with a special modification prompted by PNNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive study of the X-ray flares from gamma-ray bursts observed by Swift

X-ray flares are generally supposed to be produced by later activities of the central engine, and may share a similar physical origin with the prompt emission of gamma-ray bursts (GRBs). In this paper, we have analyzed all significant X-ray flares from the GRBs observed by Swift from 2005 April to 2015 March. The catalog contains 468 bright X-ray flares, including 200 flares with redshifts. We obtain the fitting results of X-ray flares, such as start time, peak time, duration, peak flux, fluence, peak luminosity, and mean luminosity. The peak luminosity decreases with peak time, following a power-law behavior L{sub p}∝T{sub peak,z}{sup −1.27}. The flare duration increases with peak time. The 0.3–10 keV isotropic energy of the distribution of X-ray flares is a log-normal peaked at 10{sup 51.2} erg. We also study the frequency distributions of flare parameters, including energies, durations, peak fluxes, rise times, decay times, and waiting times. Power-law distributions of energies, durations, peak fluxes, and waiting times are found in GRB X-ray flares and solar flares. These distributions could be well explained by a fractal-diffusive, self-organized criticality model. Some theoretical models based on magnetic reconnection have been proposed to explain X-ray flares. Our result shows that the relativistic jets of GRBs may be dominated by Poynting flux.

79 ASTRONOMY AND ASTROPHYSICS↗