Search NASA⌕ Search

SEARCH · Search NASA

Results for “PSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Implementation of an Unsteady PSP System in the NASA TDT

An unsteady pressure-sensitive paint (uPSP) system has been developed to provide time-resolved pressure measurements in the NASA Langley Transonic Dynamics Tunnel (TDT). Obtaining these measurements necessitated the development of environmental enclosures to protect the high-speed camera and ultraviolet lights required for uPSP from the harsh environment present during tunnel operation. Since the facility main drive was non-functioning during the testing window, performance of the uPSP system was demonstrated using an impinging jet with a passive oscillator attachment to provide unsteady flow with a known frequency independent of amplitude. Measurements were obtained for tunnel pressures ranging from 565 to 2116 psf, and model angles of attack between -4 degrees and 4 degrees. Results indicate that the system is capable of measuring surface pressure differentials on the order of 0.01 psi at full scale with a camera frame rate of at least 10 kHz. Spectral analysis shows that the fundamental frequency of the oscillating jet is captured by the uPSP system, as are the second and third harmonics. Dynamic mode decomposition highlights the dominant coherent spatial structures of the surface pressure, along with the associated frequency and growth rate of each mode, allowing for a de-noised reconstruction of the uPSP measurements. The experimental campaign outlined within this report also confirmed compatibility of the uPSP system with the TDT facility data acquisition system, and verified the successful integration with existing processing capabilities within the NASA advanced supercomputing environment. Note: this presentation is an MP4 video with sound, color with a run time of 10 minutes 37 seconds.

unsteady pressure-sensitive paint↗

Application of PSP on the SWiFT Model in the National Transonic Facility

This report details the results from a Pressure Sensitive Paint test on a blended/hybrid wing body model conducted at the National Transonic Facility. This test investigated potential instabilities that can occur at high Reynolds number and low Mach number testing conditions. The upper surface of the model was coated with pressure sensitive paint, and data was collected at various Mach numbers and angles of attack. For this test, typical pitch-pause testing was completed as well as a novel continuous sweep functionality that provided much greater angle of attack resolution. Results from this test will be presented, including indications of potential instability points in the testing envelope.

NTF↗

Unsteady PSP in the NASA Transonic Dynamics Tunnel

For the first time, unsteady pressure sensitive paint (uPSP) has been applied in the NASA Langley Transonic Dynamics Tunnel. Obtaining global surface pressure measurements using the uPSP technique required the development of a new paint formulation for use in the low oxygen heavy gas atmosphere, as well as environmental enclosures to protect sensitive electro-optical components from the high temperature, low pressure environment present during tunnel operation. A high-speed datalink connecting the wind tunnel to Langley’s local high performance compute resource was also established for this test to enable near real time processing of the large datasets that were obtained throughout the campaign. A high-speed lifetime measurement technique was also utilized to yield steady state surface pressures at each condition using the same equipment that was used to provide unsteady measurements. Important metrics such as pressure time histories and power spectral density are compared against traditional unsteady pressure point measurements, and more advanced data products such as dynamic mode decomposition are also explored to provide insight into the underlying flow phenomena.

Daniel T. Reese↗

Nanorod-Based Fast-Response Pressure-Sensitive Paints

A proposed program of research and development would be devoted to exploitation of nanomaterials in pressuresensitive paints (PSPs), which are used on wind-tunnel models for mapping surface pressures associated with flow fields. Heretofore, some success has been achieved in measuring steady-state pressures by use of PSPs, but success in measuring temporally varying pressures has been elusive because of the inherent slowness of the optical responses of these materials. A PSP contains a dye that luminesces in a suitable wavelength range in response to photoexcitation in a shorter wavelength range. The luminescence is quenched by oxygen at a rate proportional to the partial pressure of oxygen and thus proportional to the pressure of air. As a result, the intensity of luminescence varies inversely with the pressure of air. The major problem in developing a PSP that could be easily applied to a wind-tunnel model and could be useful for measuring rapidly varying pressure is to provide very high gas diffusivity for rapid, easy transport of oxygen to and from active dye molecules. Most PSPs include polymer-base binders, which limit the penetration of oxygen to dye molecules, thereby reducing responses to pressure fluctuations. The proposed incorporation of nanomaterials (somewhat more specifically, nanorods) would result in paints having nanostructured surfaces that, relative to conventional PSP surfaces, would afford easier and more nearly complete access of oxygen molecules to dye molecules. One measure of greater access is effective surface area: For a typical PSP as proposed applied to a given solid surface, the nanometer-scale structural features would result in an exposed surface area more than 100 times that of a conventional PSP, and the mass of proposed PSP needed to cover the surface would be less than tenth of the mass of the conventional PSP. One aspect of the proposed development would be to synthesize nanorods of Si/SiO2, in both tangle-mat and regular- array forms, by use of chemical vapor deposition (CVD) and wet chemical processes, respectively. The rods would be coated with a PSP dye, and the resulting PSP signals would be compared with those obtained from PSP dye coats on conventional support materials. Another aspect of the proposed development would be to seek to exploit the quantum properties of nanorods of a suitable semiconductor (possibly GaN), which would be synthesized by CVD. These quantum properties of semiconductor nanorods include narrow-wavelength-band optical absorption and emission characteristics that vary with temperature. The temperature sensitivity might enable simultaneous measurement of fluctuating temperature and pressure and to provide a temperature correction for the PSP response.

Bencic, Timothy↗

Determination of the Thermal Offset of the Eppley Precision Spectral Pyranometer

Eppley's precision spectral pyranometer (PSP) is used in networks around the world to measure downwelling diffuse and global solar irradiance at the surface of the Earth. In recent years several studies have shown significant discrepancy between irradiances measured by pyranometers and those computed by atmospheric radiative transfer models. Pyranometer measurements have been questioned because observed diffuse irradiances sometimes are below theoretical minimum values for a pure molecular atmosphere, and at night the instruments often produce nonzero signals ranging between + 5 and - 10 W/sq m. We install thermistor sondes in the body of a PSP as well as on its inner dome to monitor the temperature gradients within the instrument, and we operate a pyrgeometer (PIR) instrument side by side with the PSP. We derive a relationship between the PSP output and thermal radiative exchange by the dome and the detector and a relationship between the PSP output and the PIR thermopile output (net-IR). We determine the true PSP offset by quickly capping the instrument at set time intervals. For a ventilated and shaded PSP, the thermal offset can reach - 15 W/sq m under clear skies, whereas it remains close to zero for low overcast clouds. We estimate the PSP thermal offset by two methods: (1) using the PSP temperatures and (2) using the PIR net-IR signal. The offset computed from the PSP temperatures yields a reliable estimate of the true offset (+/- 1 W/sq m). The offset computed from net-IR is consistent with the true offset at night and under overcast skies but predicts only part of the true range under clear skies.

Haeffelin, Martial↗

Forced and Moment Measurements with Pressure-Sensitive Paint

The potential of pressure-sensitive paint (PSP) to provide aerodynamic loads measurements has been a driving force behind the development of this measurement technique. To demonstrate the suitability of PSP for this purpose, it is necessary to show that PSP-derived pressures can be accurately integrated over the model surface. This cannot be done simply by demonstrating the accuracy of PSP as compared to pressure taps. PSP errors due to misregistration or temperature sensitivity may be high near model edges, where they will have a strong effect on moment measurements, but where pressure taps are rarely installed. A more suitable technique is to compare integrated PSP data over the entire model surface with balance and/or CFD results. This paper presents results from three experiments in which integrated PSP data is compared with balance and/or CFD data. This allows the usefulness of PSP for force and moment measurements, and by implication for loads measurements, to be assessed.

Bell, James H.↗

Application of Pressure Sensitive Paint to Confined Flow at Mach Number 2.5

Pressure sensitive paint (PSP) is a novel technology that is being used frequently in external aerodynamics. For internal flows in narrow channels, and applications at elevated nonuniform temperatures, however, there are still unresolved problems that complicate the procedures for calibrating PSP signals. To address some of these problems, investigations were carried out in a narrow channel with supersonic flows of Mach 2.5. The first set of tests focused on the distribution of the wall pressure in the diverging section of the test channel downstream of the nozzle throat. The second set dealt with the distribution of wall static pressure due to the shock/wall interaction caused by a 25 deg. wedge in the constant Mach number part of the test section. In addition, the total temperature of the flow was varied to assess the effects of temperature on the PSP signal. Finally, contamination of the pressure field data, caused by internal reflection of the PSP signal in a narrow channel, was demonstrated. The local wall pressures were measured with static taps, and the wall pressure distributions were acquired by using PSP. The PSP results gave excellent qualitative impressions of the pressure field investigated. However, the quantitative results, specifically the accuracy of the PSP data in narrow channels, show that improvements need to be made in the calibration procedures, particularly for heated flows. In the cases investigated, the experimental error had a standard deviation of +/- 8.0% for the unheated flow, and +/- 16.0% for the heated flow, at an average pressure of 11 kpa.

Lepicovsky, J.↗

Pressure-Sensitive Paint Measurements on Surfaces with Non-Uniform Temperature

Pressure-sensitive paint (PSP) has become a useful tool to augment conventional pressure taps in measuring the surface pressure distribution of aerodynamic components in wind tunnel testing. While the PSP offers the advantage of a non-intrusive global mapping of the surface pressure, one prominent drawback to the accuracy of this technique is the inherent temperature sensitivity of the coating's luminescent intensity. A typical aerodynamic surface PSP test has relied on the coated surface to be both spatially and temporally isothermal, along with conventional instrumentation for an in situ calibration to generate the highest accuracy pressure mappings. In some tests however, spatial and temporal thermal gradients are generated by the nature of the test as in a blowing jet impinging on a surface. In these cases, the temperature variations on the painted surface must be accounted for in order to yield high accuracy and reliable data. A new temperature correction technique was developed at NASA Lewis to collapse a "family" of PSP calibration curves to a single intensity ratio versus pressure curve. This correction allows a streamlined procedure to be followed whether or not temperature information is used in the data reduction of the PSP. This paper explores the use of conventional instrumentation such as thermocouples and pressure taps along with temperature-sensitive paint (TSP) to correct for the thermal gradients that exist in aeropropulsion PSP tests. Temperature corrected PSP measurements for both a supersonic mixer ejector and jet cavity interaction tests are presented.

Bencic, Timothy J.↗

Source and Propagation of a Streamer Blowout Coronal Mass Ejection Observed by the Parker Solar Probe

In the first orbit of the Parker Solar Probe (PSP), in situ thermal plasma and magnetic field measurements were collected as close as 35RSun from the Sun, an environment that had not been previously explored. During the first orbit of PSP, the spacecraft flew through a streamer blowout coronal mass ejection (SBO-CME) on 2018 November 11 at 23:50 UT as it exited the science encounter. The SBO-CME on November 11 was directed away from the Earth and was not visible by L1 or Earth-based telescopes due to this geometric configuration. However, PSP and the STEREO-A spacecraft were able to make observations of this slow (v ≈ 380 kms−1) SBO-CME. Using the PSP data, STEREO-A images, and Wang–Sheeley–Arge model, the source region of the CME is found to be a helmet streamer formed between the northern polar coronal hole and a mid-latitude coronal hole. Using the YGUAZU-A model, the propagation of the CME is traced from the source at the Sun to PSP. This model predicts the travel time of the flux rope to the PSP spacecraft as 30 hr, which is within 0.33 hr of the actual measured arrival time. The in situ Solar Wind Electrons Alphas and Protons data were examined to determine that no shock was associated with this SBO-CME. Modeling of the SBO-CME shows that no shock was present at PSP; however, at other positions along the SBO-CME front, a shock could have formed. The geometry of the event requires in situ and remote sensing observations to characterize the SBO-CME and further understand its role in space weather.

Kelly Elizabeth Korreck↗

Diffusion Time-Scale of Porous Pressure-Sensitive Paint

Pressure-sensitive paint (PSP) is an optical pressure sensor that utilizes the oxygen quenching of luminescence. PSP measurements in unsteady aerodynamic flows require fast time response of the paint. There are two characteristic time-scales that are related to the time response of PSP. One is the luminescent lifetime representing an intrinsic physical limit for the achievable temporal resolution of PSP. Another is the time-scale of oxygen diffusion across the PSP layer. When the time-scale of oxygen diffusion is much larger than the luminescent lifetime, the time response of PSP is controlled by oxygen diffusion. In a thin homogenous polymer layer where diffusion is Fickian, the oxygen concentration 1021 can be described by the diffusion equation in one-dimension.

Liu, Tianshu↗

Accuracy of Pressure Sensitive Paint

Uncertainty in pressure sensitive paint (PSP) measurement is investigated from a standpoint of system modeling. A functional relation between the imaging system output and luminescent emission from PSP is obtained based on studies of radiative energy transports in PSP and photodetector response to luminescence. This relation provides insights into physical origins of various elemental error sources and allows estimate of the total PSP measurement uncertainty contributed by the elemental errors. The elemental errors and their sensitivity coefficients in the error propagation equation are evaluated. Useful formulas are given for the minimum pressure uncertainty that PSP can possibly achieve and the upper bounds of the elemental errors to meet required pressure accuracy. An instructive example of a Joukowsky airfoil in subsonic flows is given to illustrate uncertainty estimates in PSP measurements.

Liu, Tianshu↗

Water-Based Pressure Sensitive Paint

Preparation and performance of a water-based pressure sensitive paint (PSP) is described. A water emulsion of an oxygen permeable polymer and a platinum porphyrin type luminescent compound were dispersed in a water matrix to produce a PSP that performs well without the use of volatile, toxic solvents. The primary advantages of this PSP are reduced contamination of wind tunnels in which it is used, lower health risk to its users, and easier cleanup and disposal. This also represents a cost reduction by eliminating the need for elaborate ventilation and user protection during application. The water-based PSP described has all the characteristics associated with water-based paints (low toxicity, very low volatile organic chemicals, and easy water cleanup) but also has high performance as a global pressure sensor for PSP measurements in wind tunnels. The use of a water-based PSP virtually eliminates the toxic fumes associated with the application of PSPs to a model in wind tunnels.

Oglesby, Donald M.↗