Search NASA⌕ Search

SEARCH · Search NASA

Results for “PURITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Strong effect of scandium source purity on chemical and electronic properties of epitaxial Sc x Al 1–x N/GaN heterostructures

Epitaxial multilayer heterostructures of Sc x Al 1–x N/GaN with Sc contents x = 0.11–0.45 are found to exhibit significant differences in structural quality, chemical impurity levels, and electronic properties depending on the starting Sc source impurity levels. A higher purity source leads to a 2–3 orders of magnitude reduction in the carbon, oxygen, and fluorine unintentional doping densities in MBE-grown Sc x Al 1–x N/GaN multilayers. Electrical measurements of Sc x Al 1–x N/n + GaN single heterostructure barriers show a 5–7 orders of magnitude reduction in the electrical leakage for films grown with a higher purity Sc source at most Sc contents. The measured chemical and electrical properties of epitaxial Sc x Al 1–x N highlight the importance of the starting Sc source material purity for epitaxial device applications that need these highly piezoelectric and/or ferroelectric transition-metal nitride alloys.

36 MATERIALS SCIENCE↗

The Influence of Strain Path and Heat Treatment Variations on Recrystallization in Cold-Rolled High-Purity Niobium Polycrystals

With the standard material and cavity production guidelines, the properties and performance of industrially produced high-purity niobium superconducting radiofrequency (SRF) cavities are unpredictably variable. Currently, assembled niobium SRF cavities undergo post-purification vacuum heat treatment at 800 °C for three hours to remove hydrogen and increase performance; however, recent work has shown significant improvements in cavity performance when annealed between 900–1000 °C, causing recrystallization (Rx). Increasing the annealing temperature and/or the heating rate should facilitate the onset of Rx, resulting in a greater reduction in the density of geometrically necessary dislocations (GNDs) that are strongly associated with the degradation of cavity performance via trapped magnetic flux. Improving the SRF community's understanding of the influence of both heat treatment and deformation history on the resulting microstructure and Rx behavior in high-purity niobium is needed. This fundamental metallurgy is critical for identifying improved specifications for the consistent production of high-performing niobium SRF cavities. This research investigates variations in deformation paths, heating rates, and annealing temperatures on Rx of deformed samples of polycrystalline high-purity niobium. To assess the effects of strain path, samples were cold-rolled to ~30% reduction prior to annealing, with half of the sample set rolled parallel to the as-received niobium sheet and the other half in the transverse direction.

36 MATERIALS SCIENCE↗

Enhanced spectral purity of WSe 2 quantum emitters via conformal organic adlayers

Quantum emitters in solid-state materials are typically embedded in the bulk of their hosts, making their electronic transitions inaccessible to surface modification. In contrast, two-dimensional materials, with their all-surface nature, offer a platform for tuning quantum emitters via chemical functionalization. Because of its semiconducting properties that enable electrical addressability, monolayer WSe 2 is a promising candidate for quantum emission, although the complex interplay between point defects and the localized strain needed to activate quantum emission leads to poor spectral purity. Here, we demonstrate that functionalizing monolayer WSe 2 with conformal adlayers of 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA) improves quantum emission spectral purity. Optical spectroscopy reveals that PTCDA functionalization lowers defect activation energies by 10 meV and induces a 30 nm redshift in quantum emission wavelength, while preserving the bright and dark exciton energies of monolayer WSe 2 . First-principles calculations corroborate these findings, thus providing molecular-level insight into the underlying mechanism of enhanced spectral purity.

Ananth, Riddhi [Northwestern Univ., Evanston, IL (↗

Blinking compromises the single-photon purity of individual CsPbBr 3 perovskite nanocrystals

Individual lead halide perovskite nanocrystals (PNCs) are promising single photon emitters but often suffer from photoluminescence blinking. Here, we correlate the photoluminescence blinking behavior of CsPbBr 3 NCs with their second-order correlation functions. We find that even moderate band-edge carrier blinking (BC-blinking) can significantly decrease the PNC’s single photon purity, while the impact from Auger blinking is much smaller. Additionally, the degree of BC-blinking can introduce significant uncertainties in single photon purity compared to PNCs with suppressed blinking. Furthermore, we quantitatively correlate the decrease in single photon purity with BC-blinking severity.

36 MATERIALS SCIENCE↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful sel ection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful selection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector

The Short-Baseline Neutrino (SBN) program at Fermilab will pursue neutrino properties searches, exploiting three Liquid Argon Time Projection Chamber (LArTPC) experiments to investigate neutrino oscillations with neutrinos from the Booster Neutrino Beam (BNB). SBND will be the near detector in the program, measuring the un-oscillated flux. It is anticipated to begin operating in 2023. Thanks to its peculiar proximity to the neutrino source of about 110 meters, SBND will collect extremely high statistics data of the flux in the GeV energy range, providing unprecedented precision measurements. SBND particular setting also allows to take measurements at different distances from BNB’s center maintaining statistics high enough at each range. LArTPC and the cold electronics technologies, as well as the argon-neutrino interaction studies, will play a key role in future neutrino physics. In this prospect, this work was focused on two SBND features: SBND PRISM tool, with the aim of investigating neutrino flux at different distances from the beam axis, and Purity Monitors, which provide a clever measurement of argon purity in the detector, whose value is fundamental in neutrino-argon interaction.

43 PARTICLE ACCELERATORS↗

Effect of solenoidal magnetic field on charge-state purity in laser ion source

A solenoidal magnetic field has been used to enhance the ion flux of a laser ion source. However, the dependence of the increase in ion current on the charge-state has not been clarified. In this study, to control the purity of the charge-state in the laser ion source, we investigated the effect of a solenoidal magnetic field on the charge-state distribution of ions in laser ion sources with a solenoid. The results indicate that the flux of ions with a heavier and/or lower charge-state can be increased using higher magnetic flux densities, and that each charged ion has an optimal solenoidal magnetic flux density that maximizes its flux. These results imply that it is possible to increase the purity of the desired charge-state ions by selecting a suitable solenoidal magnetic flux density.

43 PARTICLE ACCELERATORS↗

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La↗

The impact of nickel concentration and stacking fault energy on deformation mechanisms in high-purity austenitic Fe-Cr-Ni alloys

Understanding how composition affects deformation mechanisms in austenitic stainless steels is essential for developing accurate predictive models of stress-induced failures and stress corrosion cracking. Nickel (Ni), an element classified as a critical element, plays a crucial role in these processes. It is important to examine how Ni concentration influences stacking fault energy (SFE) and, consequently, the deformation mechanisms of austenitic stainless steels. However, in commercial stainless steels, the effects of other alloying elements and impurities can obscure Ni's role, complicating efforts to isolate its impact. Here, in this study, we use two high-purity Fe-Cr-Ni alloys to investigate how Ni concentration and SFE interact to alter deformation mechanisms and induce martensitic transformation. By combining in situ synchrotron X-ray diffraction (XRD) tensile testing and post-mortem electron microscopy with density functional theory simulations, we gain precise insights into these phenomena. We find that the Fe18Cr10Ni (wt%) alloy, with its low SFE, exhibits higher stacking fault probability, deformation-induced martensitic transformation, and a lesser increase in dislocation density with plastic strain. In contrast, the Fe18Cr14Ni (wt%) alloy, with its higher SFE, shows enhanced deformation twinning and greater dislocation density with increasing strain. These findings from high-purity ternary alloys provide valuable insights that can guide the search for alternative elements to replace Ni while achieving similar effects on phase stability and deformation behavior.

36 MATERIALS SCIENCE↗

Experimental investigation of the dependence of void nucleation and growth on initial microstructure in high-purity titanium under tension

An experimental investigation of failure mechanisms in relation to the initial microstructure in high-purity titanium samples is presented. The initial microstructure of the specimens was measured in 3D using diffraction-contrast tomography (DCT). Ex-situ X-ray computed tomography (XCT) was used to visualize voids in specimens at various levels of deformation attained by interrupted tensile testing. Electron backscatter diffraction (EBSD) mapping was used to characterize the deformed microstructures per specimen. The investigation showed that the location of failures was unrelated to the formation of the first voids, but rather the nucleation and growth of cracks were from heavily deformed surface regions. The areas surrounding the failure-causing cracks had the highest propensity for void development of any area in the specimen. This facilitated crack propagation through the specimen via “linking up”. The failure of the specimens by microvoid coalescence was bolstered by “dimpled” fracture surfaces. Paint composed of gallium embedded in rubber was used to track the displacement of points along the loading direction of the specimens, to relate the location of failure to the material's initial microstructure. However, the correlation proved difficult, due to complex microstructural evolution involving voids, grain fragmentations, and profuse twinning. Nevertheless, it was shown that necking occurred near the largest grain in the gauge section of the specimens. This is likely caused by the decrease in strength of larger grains, causing strain to concentrate in their vicinity. Here, a comprehensive picture of the failure processes in high-purity titanium under axial loading is presented and discussed in the paper.

36 MATERIALS SCIENCE↗

Protein-based approach for high-purity Sc, Y, and grouped lanthanide separation

Rare earth elements (REEs: Sc, Y, La- Lu) are irreplaceable components in many clean energy and consumer technologies. However, the extraction and subsequent separation of individual REEs from ore-based feedstocks remains a significant economic and environmental challenge. Here in this work, we investigated the intra-REE separation potential of lanmodulin (LanM), a natural protein from Methylorubrum extorquens that has emerged as a sustainable potential alternative to conventional solvent extraction-based separation. By determining the intra-REE selectivity of immobilized LanM and systematically testing pH-based and small chelator-based (i.e., citrate and malonate) desorption processes, we established the framework and methodology for achieving select individual and grouped REE separations from a mixed REE feedstock. We show that Sc forms the tightest complex with LanM among REEs but can be readily and selectively desorbed using malonate to generate high-purity Sc (>99 % purity, >99 % yield) in a single adsorption/desorption cycle. We further show that the intrinsic REE selectivity of LanM is sufficient to achieve heavy REE (HREE) separation from light and middle REEs (L-MREEs), yielding an yttrium-enriched product. This separation effect is further magnified by pairing LanM’s unique M-LREE preference with a HREE-preferring chelator in the desorption process, which enriches HREE and MREE fractions relative to low value, abundant La/Ce. Finally, by combining pH- and citrate-based desorption processes in a two-cycle separation scheme, we demonstrate the generation of fractions highly enriched in Y, Gd-Lu, Pr-Eu, and La-Ce. Collectively, these data support the application of a LanM-based approach for achieving impactful REE separations from mixed REE feedstocks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Purity Quantum Emission from an Au 24 (S-CH 2 Ph- t Bu) 20 Nanocluster at Room Temperature

Atomically precise gold nanoclusters have garnered significant attention for their diverse applications, ranging from biological labeling to optoelectronics. Their potential in optical quantum computing, which calls for ideal single-photon sources, has recently become a key area of interest. In the current work, we use photon antibunching experiments to explore the single-photon emission efficiency of atomically precise Au 24 nanoclusters protected by 4-tert-butylbenzyl mercaptan ligands (Au 24 (TBBM) 20 ). This cluster exhibits quantum emission with good photostability and without any observable blinking or spectral drift at room temperature under an inert gas atmosphere, with antibunching dips (g 2 (0)) as low as 0.07 in the solid state or, equivalently, a single-photon purity of 93% under time-gated conditions. Transient absorption and time-gated antibunching studies reveal that the short emission lifetime of this cluster and its high photoluminescence quantum yield in the solid state play critical roles in enhancing the emitted single-photon purity. This research advances the understanding of single-emitter behavior in atomically precise gold nanoclusters, contributing to the development of stable quantum emitters that are essential for quantum computing and cryptography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-purity Polypropylene from Disposable Face Masks via Solvent-Targeted Recovery and Precipitation

The high use of disposable face masks since the start of COVID-19 has globally generated 4.68–6.24 million tons per year of waste from personal protective equipment. Disposable face masks are generally disposed of in landfills. Polypropylene (PP) is the main component in face masks, which is one of the least recycled plastics but has a high market value. In this work, we extract high-quality PP from face masks using solvent-targeted recovery and precipitation (STRAP) with 90 wt% recovery. N,N-Dimethylacetamide removed the color from the recovered PP to produce a clear high-purity PP, as verified by CIELAB color space. The decolored PP shows similar thermochemical properties and color to virgin PP resin. Here, a techno-economic analysis of the process indicates that high-purity PP recovery can be economically viable at a scale of 5000 tons per year or higher.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗

Qubit-state purity oscillations from anisotropic transverse noise

We explore the dynamics of qubit-state purity in the presence of transverse noise that is anisotropically distributed in the Bloch-sphere X Y plane. We perform Ramsey experiments with noise injected along a fixed laboratory-frame axis and observe oscillations in the purity at twice the qubit frequency arising from the intrinsic qubit Larmor precession. We probe the oscillation dependence on the noise anisotropy, orientation, and power spectral density, using a low-frequency fluxonium qubit. Our results elucidate the impact of transverse noise anisotropy on qubit decoherence and may be useful for disentangling charge and flux noise in superconducting quantum circuits. Published by the American Physical Society 2025

Rower, David A. (ORCID:0000000328455616)↗