35 records · Page 2

Development of Mission Profiles for Humidity Models in the Reliability Testing of PV Inverters: Preprint

To understand the impacts of humidity on PV inverters, mission profiles were developed to accurately describe the different processes and rates based on the environmental factors of temperature, relative humidity, and irradiance. The operating environment of the device introduces stress factors dependent on component temperature, relative humidity, and component voltage. The development of profiles started from looking at historical climate conditions at Cocoa, Florida, a hot and humid location. The profile developed from field location was compared with existing humidity test profiles in industrial and military standards to determine acceleration factors. Prior to the evaluation of the mission profiles, critical components in the PV inverter were identified based on vendor discussions along with failure modes of interest. The profiles considered in this study was demonstrated using a 4-kVA string inverter. The measurements from the devices were substituted in device manufacturer specified equation to determine the severity of each test. The severity of each test was compared against the severity of the 24-hour result to determine the acceleration factor of each test. The acceleration factors were determined to be over a range of 1.2-6 for the existing humidity tests from standards, when compared against the mission profile developed from field data. This optimal humidity/thermal profile will be passed to the IEC standards development for inverter qualification testing.

humidity models↗

Field Experience Detecting PV Underperformance in Real Time Using Existing Instrumentation

Maintenance at large-scale photovoltaic plants employs a mix of preventative and corrective maintenance practices. Large outages, such as an inverter tripping offline, are often easy to detect. More subtle sub-inverter faults and failures can accumulate and go unnoticed for months or years. A software-based fault detection method has been developed to analyze commonly measured data from large-scale PV plants for more timely detection of subtle underperformance. The method has been demonstrated on eight datasets from large-scale plants with high accuracy of detection. Results are validated using aerial infrared scanning. String outages are detected with a true positive rate of 73 percent and tracker issues are detected with a true positive rate of 88 percent. The developed method can be uniformly applied to photovoltaic plants across a range of scales and configurations to assess performance, quickly detect underperformance, and determine the source and location of failures. The results inform and improve operations and maintenance at PV plants, ultimately aiding in improved affordability, reliability, availability, and resiliency of solar electricity.

14 SOLAR ENERGY↗

A High-Voltage High-Reliability Scalable Architecture for Electric Vehicle Power Electronics (Final Report)

This project developed and demonstrated new composite converter technologies that lead to high power density (> 20 kW/L) at power levels of 10s of kW, 100s of kW, or possibly higher, with fundamental advances in converter efficiency and Q that lead to substantial increases in mean time to failure (MTTF). These advantages were realized through development of new composite converter topologies that perform buck, boost, or other conversion functions and that are scalable to higher voltage and power levels through sharing of voltage and current stresses among multiple dissimilar partial-power converter modules. The project led to experimental demonstration of a125 kW multifunction electric vehicle power conversion system having in-creased dc bus voltage (950 V nominal, 1200 V peak) that interfaces a 200 V to 400 V battery pack, and that includes integrated level 2 wired charging and wireless charging functions. The project incorporated SiC MOSFET modules having switching frequencies in excess of 100 kHz, planar magnetics, a hierarchical control architecture that enables scaling to higher voltages and powers with additional converter modules, and a high-power density in excess of 20 kW/L. The research demonstrated how a more complex converter approach can increase mean-time-to-failure, even though the number of elements is increased. This is achieved through significant reduction of temperature rise through fundamentally superior converter circuit topologies. The research also demonstrated new high power planar magnetics that increase power density. The technology is appropriate to a variety of applications including EV power trains, EV charging, PV inverters, battery storage, and similar areas. These systems potentially can be manufactured in the U.S.

33 ADVANCED PROPULSION SYSTEMS↗

Model of Operation-and-Maintenance Costs for Photovoltaic Systems

This article presents a method for calculating costs associated with operation and maintenance (O&M) of photovoltaic (PV) systems. It compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($\$$/year) for each year of an analysis period, the net present value ($\$$) of life cycle costs accumulated over the analysis period, and the reserve account amount ($\$$). Here we show that this method is an improvement over the previous averaged or levelized per-unit ($\$$/kW/year) valuations for estimating PV O&M costs, because it allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string or central inverter) and site and environmental conditions (e.g., snow, pollen, bird populations). This model also distinguishes costs that vary from year to year and increase at different rates over time because of heuristic failure distributions (e.g. Weibull or Lognormal distribution) based on actuarial data for many of the services. This cost model was created by the PV O&M Working Group of researchers and industry, sponsored by DOE Solar Energy Technologies Office, and has been published in an on-line version hosted by SunSpec Alliance at apsuite.sunspec.org. A spreadsheet version is included with this paper as supplementary material.

14 SOLAR ENERGY↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Power Loss and Safety Risks - Recoverable vs. Non-Recoverable?

This presentation presents an update to the PV fleet analysis on PV system degradation. A median system degradation of -0.7 %/year was found for almost 5000 inverter traces. No significant difference between silicon and CdTe technologies were found. Systems with trackers showed a slightly higher degradation. Silicon technologies such as PERC and heterojunction showed degradation similar to conventional technologies but also showed different degradation mechanisms. To achieve long lifetimes early failure must be minimized through qualification testing. Rapid detection during normal life is important as is the control of bill of materials in modules.

degradation↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

PVAnalytics [SWR-20-33]

PVAnalytics inputs long term (multiple years) photovoltaic (PV) outdoor sensor data and completes autonomous quality assurance (QA) analysis on the data. Time series data from individual sensors such as electric meters, inverter outputs, irradiance, and temperature sensors are compared to physically expected outputs of these sensors under clear sky conditions based on the latitude, longitude, and orientation of the PV system. PVAnalytics outputs as QA pass or fail for each sensor, reasons determined for failure, time series flags identifying QA thresholds have been exceeded, flags for sunny days, the time zone found for the given sensor, sensor drift, time periods for passing data, and results of orientation checks.

Muller, Matthew↗

Automating Detection and Diagnosis of Faults, Failures, and Underperformance in PV Plants

The project developed hybrid physics-based and machine-learning methods for near-real-time detection of balance-of-system faults (e.g., string, combiner, and tracker outages) in utility-scale Photovoltaic plants, achieving over 50% true positive rates with under 10% false positives and significantly reducing engineering setup time. In the extended phase, the scope expanded to plant-level underperformance analysis and industry benchmarking through the SUPER.epri.com platform. SUPER standardizes data processing and performance metrics across more than 9 GWac and 120+ plants, enabling robust comparisons and insights into loss rates, inverter downtime, and capacity degradation.

14 SOLAR ENERGY↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

PV Field Reliability Status--Analysis of 100,000 Solar Systems

In this paper, we analyzed annual production data from 100 000 photovoltaic systems as well as comments relating to their performance and maintenance. Our analysis revealed that 80% to 90% of all systems performed within 10% of the predicted production or better. Also, 56% of the systems were still performing above P50 or the median at 5 years. However, a small but significant tail of about 7000 systems perform below P90 expectations. In general, residential systems have a lower rate of failure than utility or commercial systems. Despite higher rates of component failures, utility systems lose less power than residential or commercial systems. This outcome is likely due to closer monitoring and better operations and maintenance practices. Inverters are still the components that reportedly fail most often (4%-6%), but other failures such as unspecified repair and meters cause more production loss. Reported module failures are relatively rare (0.2%) and are within the range of historical values. Installation quality affects performance and safety as indicated by data showing connector, wiring, breaker, and fuse failures due to undersizing, electrical design, and improper connection. Lastly, early detection of degradation and proactive response resulted in less impact on production than reactive, unplanned repairs.

14 SOLAR ENERGY↗

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV O&M Cost Model [SWR-21-14]

This tool presents a method for calculating costs associated with the operation and maintenance (O&M) of photovoltaic (PV) systems. The tool compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($/year) for each year of an analysis period, the net present value ($) of life cycle costs accumulated over the analysis period, and the reserve account amount ($) that might be required to fund unexpected repairs. The reserve account includes parts inventory and is important for providing a source of funds to make repairs quickly and avoid lost production. This method allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string, or central inverter), and site and environmental conditions (e.g., pollen, bird populations) which is an improvement over simple per unit valuations of O&M costs ($/kW/year). This model also distinguishes costs that vary from year to year and increase at different rates over time as modeled by heuristic failure distributions (e.g., Weibull or Lognormal distribution) based on actuarial data for many of the services.

Walker, Andy↗