Search NASA⌕ Search

SEARCH · Search NASA

Results for “Padding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Landing Pad System for Multicopy Gene Integration in Issatchenkia orientalis

The robust nature of the non-conventional yeast Issatchenkia orientalis allows it to grow under highly acidic conditions and therefore, has gained increasing interest in producing organic acids using a variety of carbon sources. Recently, the development of a genetic toolbox for I. orientalis, including an episomal plasmid, characterization of multiple promoters and terminators, and CRISPR-Cas9 tools, has eased the metabolic engineering efforts in I. orientalis. However, multiplex engineering is still hampered by the lack of efficient multicopy integration tools. To facilitate the construction of large, complex metabolic pathways by multiplex CRISPR-Cas9-mediated genome editing, we developed a bioinformatics pipeline to identify and prioritize genome-wide intergenic loci and characterized 47 gRNAs located in 21 intergenic regions. These loci are screened for guide RNA cutting efficiency, integration efficiency of a gene cassette, the resulting cellular fitness, and GFP expression level. We further developed a landing pad system using components from these well-characterized loci, which can aid in the integration of multiple genes using single guide RNA and multiple repair templates of the user’s choice. We have demonstrated the use of the landing pad for simultaneous integrations of 2, 3, 4, or 5 genes to the target loci with efficiencies greater than 80%. As a proof of concept, we showed how the production of 5-aminolevulinic acid can be improved by integrating five copies of genes at multiple sites in one step. We have further demonstrated the efficiency of this tool by constructing a metabolic pathway for succinic acid production by integrating five gene expression cassettes using a single guide RNA along with five different repair templates, leading to the production of 9 g/L of succinic acid in batch fermentations. This study demonstrates the effectiveness of a single gRNA-mediated CRISPR platform to build complex metabolic pathways in a non-conventional yeast. This landing pad system will be a valuable tool for the metabolic engineering of I. orientalis.

Fatma, Zia↗

Wave transmission through silicone foam pads in a compression Kolsky bar apparatus. Comparisons between simulations and measurements.

This memo concerns the transmission of mechanical signals through silicone foam pads in a compression Kolsky bar set-up. The results of numerical simulations for four levels of pad pre-compression and two striker velocities were compared directly to test measurements to assess the delity of the simulations. The nite element model simulated the Kolsky tests in their entirety and used the hyperelastic `hyperfoam' model for the silicone foam pads. Calibration of the hyperfoam model was deduced from quasi-static compression data. It was necessary, however, to augment the material model by adding sti ness proportional damping in order to generate results that resembled the experimental measurements. Based on the results presented here, it is important to account for the dynamic behavior of polymeric foams in numerical simulations that involve high loading rates.

47 OTHER INSTRUMENTATION↗

Effects of Structure and Filler on Mechanical Properties of Direct Ink Write Pads

Direct ink write (DIW) is an extrusion-based additive manufacturing (AM) technique that enables superior repeatability, property tuning, and material customization compared to conventional manufacturing techniques. In this research, DIW is used to print silicone foams that must accommodate the thermal expansion of other parts. This expansion requires the material to compress and subsequently recover. Thus, a key performance metric is reducing “compression set” or deformation retained after the material is compressed. For this study, a silicone resin was compounded with a getter material, 1,4 bis(phenylethynyl)benzene (DEB) mixed with carbon-supported palladium (Pd) and printed in a variety of lattice structures. The effects of the filler and print structure on compression set were evaluated. In these experiments, 0.5-inch diameter coupons were compressed to 75% their original height for 22 hours at 70 °C, and the change in height calculated at intervals between 30 minutes and 24 hours post-decompression. The unfilled pad with skin layers had the best compression set at 0.7% ± 0.1%, followed by the unfilled pad with no skins at 1.5% ± 0.1%. As the number of filled layers increased, compression set performance degraded. The pad with filled skin layers and all filled layers had a compression set of 7.0% ± 0.3%. Additionally, the reaction extent of DEB was found to increase compression set, possibly due to the diffusion of DEB to the surface at elevated temperatures. Imaging reveals extensive crystallization at the surface. These investigations show that a non-reinforcing filler will increase compression set but that print structure can mitigate this effect.

36 MATERIALS SCIENCE↗

Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-speed x-ray imaging with the Keck pixel array detector (Keck PAD) for time-resolved experiments at synchrotron sources

Modern storage rings are readily capable of providing intense x-ray pulses, tens of picoseconds in duration, millions of times per second. Exploiting the temporal structure of these x-ray sources opens avenues for studying rapid structural changes in materials. Many processes (e.g. crack propagation, deformation on impact, turbulence, etc.) differ in detail from one sample trial to the next and would benefit from the ability to record successive x-ray images with single x-ray sensitivity while framing at 5 to 10 MHz rates. To this end, we have pursued the development of fast x-ray imaging detectors capable of collecting bursts of images that enable the isolation of single synchrotron bunches and/or bunch trains. The detector technology used is the hybrid pixel array detector (PAD) with a charge integrating front-end, and high-speed, in-pixel signal storage elements. A 384×256 pixel version, the Keck-PAD, with 150 µm × 150 µm pixels and 8 dedicated in-pixel storage elements is operational, has been tested at CHESS, and has collected data for compression wave studies. An updated version with 27 dedicated storage capacitors and identical pixel size has been fabricated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Design and optimization of cancellation coil topologies for a ferrite-less wireless EV charging pad

Ferrite cores are widely used in conventional wireless EV charging pads to reduce stray EMF emissions, but they can be brittle, heavy, and expensive. This work furthers the development of ferrite-less wireless charging pads by comparing an active and two distinct passive cancellation coil topologies as candidates to replace the ferrite. Using the software packages FEMM and MATLAB, each topology is optimized to find the best winding positions and radii to minimize leakage at a specified position under the side of the vehicle. The optimized designs are compared for shielding effectiveness, induced current, and efficiency. All three topologies are able to sufficiently reduce the leakage field below the ICNIRP limit of 27 μTrms with just one turn. Interestingly, we find that an array of simple passive cancellation loops performs similar to the more widely studied passive cancellation coil.

Scher, Aaron D.↗

Transverse field-induced nucleation pad switching modes during domain wall injection

We have used magnetic transmission X-ray microscopy (M-TXM) to image in-field magnetization configurations of patterned Ni{sub 80}Fe{sub 20} domain wall 'injection pads' and attached planar nanowires. Comparison with micromagnetic simulations suggests that the evolution of magnetic domains in rectangular injection pads depends on the relative orientation of closure domains in the remanent state. The magnetization reversal pathway is also altered by the inclusion of transverse magnetic fields. These different modes explain previous results of domain wall injection into nanowires. Even more striking was the observation of domain walls injecting halfway across the width of wider (>400 nm wide) wires but over wire lengths of several micrometers. These extended Neel walls can interact with adjacent nanowires and cause a switching in the side of the wire undergoing reversal as the domain wall continues to expand.

36 MATERIALS SCIENCE↗

Cape EGS: Frisco Pad Wells Flow Test Microseismic Data

This dataset contains microseismic data acquired during the Frisco pad flow test project led by Fervo Energy, conducted between July 17th - Aug 12th 2024, near the Utah FORGE geothermal site. The microseismic data was collected from various Utah FORGE wells: via Distributed Acoustic Sensing (DAS) fiber in 16B, and two 3-component geophones located in wells 56-32 and 78B. The dataset is structured in SEGY format, where the first six traces represent data from the geophones, and the remaining traces capture DAS data from well 16B. Each SEGY file in this dataset contains triggered microseismic events, with event initiation based on Short-Time Average over Long-Time Average (STA/LTA) detection criteria during the stimulation process. Files are grouped by time intervals and named following the structure "[WellPad][WellName][Month]_[Year]Divine_Trigger[EventNumber].sgy," indicating well pad, well name, date, and event number. Sampling parameters include a spatial sampling of approximately 2 meters for DAS channels and a temporal sampling rate of 2000 Hz, with each data record spanning 1.2 seconds. The files' coordinates are referenced to the location of the FORGE 16A-32 wellhead, positioned at UTM coordinates: Easting 334641.1891 m and Northing 4263443.693 m. The geographic coordinates for this origin are 38.50402147 latitude and -112.8963897 longitude, with an elevation of 1650.0249 meters above sea level.

15 GEOTHERMAL ENERGY↗

Dunham Pad A 4H Well

Medical CT scans, raw and processed core logging data (including XRF) and core images of the Dunham Pad A 4H well, obtained by Triana Energy, as supplemental information to the NETL Technical Report Series Crandall, D.; Brown, S.; Moore, J.; Martin, K.; Mackey, P.; Carr, T. CT Scanning and Geophysical Measurements of the Marcellus Formation from the Dunham Pad A 4H Well NETL-TRS-X-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 48.

Core Logs↗

Historical Material Analysis of DC745U Pressure Pads

As part of the Enhance Surveillance mission, it is the goal to provide suitable lifetime assessment of stockpile materials. This report is an accumulation of historical publication on the DC745U material and their findings. It is the intention that the B61 LEP program uses this collection of data to further develop their understanding and potential areas of study. DC745U is a commercially available silicone elastomer consisting of dimethyl, methyl-phenyl, and methyl-vinyl siloxane repeat units. Originally, this material was manufactured by Dow Corning as Silastic® DC745U at their manufacturing facility in Kendallville, IN. Recently, Dow Corning shifted this material to the Xiameter® brand product line. Currently, DC745U is available through Xiameter® or Dow Corning's distributor R. D. Abbott Company. DC745U is cured using 0.5 wt% vinyl-specific peroxide curing agent known as Luperox 101 or Varox DBPH-50. This silicone elastomer is used in numerous parts, including two major components (outer pressure pads and aft cap support) in the W80 and as pressure pads on the B61. DC745U is a proprietary formulation, thus Dow Corning provides limited information on its composition and properties. Based on past experience with Dow Corning, DC745U is at risk of formulation changes without notification to the costumer. A formulation change for DC745U may have a significant impact because the network structure is a key variable in determining material properties. The purpose of this report is to provide an overview of historical DC745U studies and identify gaps that need to be addressed in future work. Some of the previous studies include the following: 1. Spectroscopic characterization of raw gum stock. 2. Spectroscopic, thermal, and mechanical studies on cured DC745U. 3. Nuclear Magnetic Resonance (NMR) and solvent swelling studies on DC745U with different crosslink densities. 4. NMR, solvent swelling, thermal, and mechanical studies on thermally aged DC745U. 5. NMR, solvent swelling, thermal, and mechanical studies on radiolytically aged DC745U. Each area is reviewed and further work is suggested to improve our understanding of DC745U for systems engineering, surveillance, aging assessments, and lifetime assessment.

36 MATERIALS SCIENCE↗

Low Temperature Studies on DC745U Pressure Pads

DC745U is a silica-filled solid silicone elastomer used to manufacture pressure pads for a variety of applications. The material is proprietary to Dow Corning and thus very little information on its composition and properties is available. A considerable amount of characterization work has been conducted (Denisse Ortiz-Acosta W-1-TR-0098U/ LA-UR-12-23612) on DC745U. Based on these studies an estimate of the composition of the polymer was obtained. DC745U is composed of ≤ 100 wt% dimethyl siloxane repeat units, ≤1.5 wt% of methylphenyl siloxane, and ≤ 1 wt% methylvinyl siloxane groups. The methylvinyl siloxane groups are used as crosslink sites. The polymer is cured using a vinyl-specific peroxide, Varox DBPH-50, at 160ºC to form a polymer network. The structure and composition of this polymer network provide DC745U its unique properties. The methylphenyl siloxane repeat unit was added to improve DC745U’s thermal properties when compared to polydimethylsiloxane (PDMS). PDMS has a glass transition temperature of -120ºC and a melting temperature of -40ºC. It is believed that the phenyl group in DC745U improves thermal properties by inhibiting crystallization. This report describes the results obtained from low temperature thermal, mechanical and molecular characterization. These studies were conducted to improve our understanding of low temperature crystallization kinetics and thermal kinetics under compression strain and to determine if the pad undergoes stress deformations under these extreme conditions. Results described herein address several knowledge gaps previously stated in the report W-1-TR-0098U. Experiments described here include Differential Scanning Calorimetry (DSC), Dynamic Mechanical Analysis (DMA), Nuclear Magnetic Resonance (NMR), and mechanical (stress/strain) tests.

36 MATERIALS SCIENCE↗

Sintered Silver Joint Strength Dependence on Substrate Topography and Attachment Pad Geometry

The sum of chemical and mechanical bonding limits the adhesive strength of die-attach and substrate-attach layers. This is also true for sintered silver joints whose development and employment are underway in the electronic packaging community. Chemical bonding is dictated by numerous parameters associated with the compatibility of the metallurgical bond of the two mating surfaces and the processing history that brings them together. However, the efficacy of mechanical bonding is likely affected by the topographies (e.g., roughness) of the two adjoined surfaces and also perhaps the shape of the attachment layer itself (e.g., circles, squares, and sizes thereof). In this study the mechanical bonding component is examined through the modification of the copper cladding surface on direct bonded copper (DBC) substrates, the shape of the silver pad attachment bonded to it, and the use of a joined 'DBC sandwich' that facilitates their study. It was found that simple employment of both surface topography control and printed pad geometry can affect and improve shear strength of silver sintered joints, and that there is logic to perhaps hybridize their effects. This is an important observation as more future attention is devoted to joining constituents with larger areas (> 100 mm2) in electronic packages.

36 MATERIALS SCIENCE↗

Design and Construction of a 1m×1m Thermal Neutron Imager Operating in Ionization Mode with Pad Readout

We have developed a 3He based thermal neutron imager with an active area of 1m×1m, for the small-angle neutron scattering beamline QUOKKA at the Australian Nuclear Science and Technology Organisation (ANSTO). The detector operates in ionization mode without any electron multiplication in the gas. The electrons created by the neutron-3He interaction are collected by discrete anode pads, each connected to an input channel of an ASIC directly mounted on the back of the anode pad plane. These custom ASICs and their readout boards can process up to 25k /s per channel. Combining the nearly 40,000 parallel channels on this detector, a total count rate of 108 cps can be achieved. Design and construction details of this detector, as well as some early test results are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Salt Lubricant Pads for U Extrusion

This report primarily describes the processing of carbonate-salt solid-lubricant pads or compacts for use in the hot metal extrusion process. It also provides an overview of the solid lubricant development process, encompassing the processing and evaluation of glass and carbonate salt materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗