SEARCH · Search NASA
Results for “Particle Mobility”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Scanning mobility particle sizer measurements from 4 to 100 nm collected at the EPCAPE Mount Soledad site from 04/15/2023 to 06/15/2023
NanoSMPS measurements from the Soledad site. The instrument measured particle size distributions from 4nm to 100nm in 5-minute intervals. Time is recorded in seconds since 1/1/1904.
EPCAPE-PT-LANL Measurements: Nano-Scanning Mobility Particle Sizer
Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: NanoScan SMPS Nanoparticle Sizer 3910 (TSI). Data Notes: The NanoScan replaced our SMPS, on November 22nd 2023 and ran until the end of the campaign. Header: - List [11 nm to 365 nm] middle of the size bin in nanometers: Data reports the concentration particles in this size bin per cubic centimeter, dN/dLog(dp). - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.
Anomalous mobility of highly charged particles in pores
Single micropores in resistive-pulse technique were used to understand a complex dependence of particle mobility on its surface charge density. We show that the mobility of highly charged carboxylated particles decreases with the increase of the solution pH due to an interplay of three effects: (i) ion condensation, (ii) formation of an asymmetric electrical double layer around the particle, and (iii) electroosmotic flow induced by the charges on the pore walls and the particle surfaces. The results are important for applying resistive-pulse technique to determine surface charge density and zeta potential of the particles. As a result, the experiments also indicate the presence of condensed ions, which contribute to the measured current if a sufficiently high electric field is applied across the pore.
Particle emissions from mobile sources: Discussion of ultrafine particle emissions and definition
There is no universally agreed upon definition for ultrafine particles (UFP). Commonly used definitions for UFP are either particle number below 100 nm or total particle number, but without an agreed upon lower cut point. For example, a lower cut point of 3 nm compared to 10 nm could result in a substantially higher count. Another definition for UFP is total particle mass but without a commonly agreed upon aerodynamic diameter upper cut point, e.g., below 100 nm, 200 nm, 300 nm, etc. Yet another definition is lung deposited surface area weighted by lung deposition fraction, found mainly in the particle mobility diameter range from 20 to 400 nm. It is clear from these definitions that there are inconsistencies in the way UFP is used and defined in the literature. Sometimes these metrics are well correlated, sometimes not. In this paper we suggest three exposure metrics: UFP-N, UFP-M, and UFP-S, that we believe will add clarity. These metrics represent total number, mass, and surface area below 500 nm, respectively. For surface area and mass, the 500 nm cut point can be either aerodynamic or mobility diameter depending upon measurement methodology. For all metrics, this cut point captures nearly all of the primary particle emissions from mobile sources. Furthermore, UFP-N would include a lower cut point of 3–6 nm and would not require an upper size cut point because there is very little particle number above 500 nm or even above 100 nm. Thus, our definition of UFP-N is consistent with the current definition of ultrafine number except for, importantly, the specification of a lower cut point. These exposure metrics can help facilitate consistency in the characterization of both short- and long-term UFP ambient exposures and associated health effects in epidemiological studies.
Fate and transport of unruptured tri-structural isotropic (TRISO) fuel particles in the event of environmental release for advanced and micro reactor applications
Advanced nuclear reactor designs and advanced fuel types offer safety features that may reduce environmental consequences in an accident scenario when compared to conventional reactors and fuels. One advanced reactor fuel is tri-structural isotropic (TRISO) fuel particles which are approximately 0.9 mm in diameter. TRISO particle mobility, assuming the particle is unruptured and the encapsulated radionuclides are contained, was explored through a theoretical examination of mobility through atmospheric, soil and groundwater, surface water, and non-human biota transport pathways. TRISO particles are too large and dense to travel in the atmosphere except under extreme conditions. TRISO particles are too large to penetrate most soil profiles and so cannot be transported with groundwater. TRISO particles will settle out of the water column in surface waters but the transport will depend on the energy of the body of water and likelihood of extreme dispersion events. TRISO particles could be transported by non-human biota. The size of TRISO particles could allow them to be intentionally moved by non-human biota if they are ingested as a gastrolith or if they are mistaken for something in the organism’s diet. Generally, TRISO particles will have reduced environmental mobility compared to releases of radionuclides in the event of an accident in a conventional nuclear reactor. The extent of transport has implications in emergency planning zone designations and other considerations for licensing and deploying TRISO-fueled reactors. Finally, further research and experimental work exploring TRISO particle mobility is required to understand the full environmental mobility of TRISO particles.
Tandem Differential Mobility Analyzer/Aerodynamic Particle Sizer (APS) Handbook
The tandem differential mobility analyzer (TDMA) is a single instrument that cycles through a series of complementary measurements of the physical properties of size-resolved submicron particles. In 2008, the TDMA was augmented through the addition of an aerodynamic particle sizer (APS), which extends the upper limit of the measured size distribution into the supermicron range. These two instruments are operated in parallel, but because they are controlled by a common computer and because the size distributions measured by the two are integrated in the produced datastreams, they are described together here. Throughout the day, the TDMA sequentially measures submicron aerosol size distributions and size-resolved hygroscopic growth distributions. More specifically, the instrument is operated as a scanning DMA to measure size distributions and as a TDMA to measure size-resolved hygroscopicity. A typical measurement sequence requires roughly 45 minutes. Each morning additional measurements are made of the relative humidity (RH) dependent hygroscopicity and temperature-dependent volatility of size-resolved particles. When the outside temperature and RH are within acceptable ranges, the hydration state of size-resolved particles is also characterized. The measured aerosol distributions complement the array of aerosol instruments in the Aerosol Observing System (AOS) and provide additional details of the light-scattering and cloud-nucleating characteristics of the aerosol.
mergedsmpsaps
Merged aerosol particle size distributions for the Aerodynamic Particle Sizer (APS) and Scanning Mobility Particle Sizer (SMPS) instruments
mergedsmpsapsml
Merged aerosol particle size distributions for the Aerodynamic Particle Sizer (APS) and Scanning Mobility Particle Sizer (SMPS) instruments with Machine Learning Quality Checks Applied
Soot Particle Studies - Instrument Inter-Comparison – Project Overview
An inter-comparison study of instruments designed to measure the microphysical and optical properties of soot particles was completed. The following mass-based instruments were tested: Couette Centrifugal Particle Mass Analyzer (CPMA), Time-of-Flight Aerosol Mass Spectrometer - Scanning Mobility Particle Sizer (AMS-SMPS), Single Particle Soot Photometer (SP2), Soot Particle-Aerosol Mass Spectrometer (SP-AMS) and Photoelectric Aerosol Sensor (PAS2000CE). Optical instruments measured absorption (photoacoustic, interferometric, and filter-based), scattering (in situ), and extinction (light attenuation within an optical cavity). The study covered an experimental matrix consisting of 318 runs that systematically tested the performance of instruments across a range of parameters including: fuel equivalence ratio (1.8 {le} {phi} {le} 5), particle shape (mass-mobility exponent (D{sub f m}), 2.0 {le} D{sub f m} {le} 3.0), particle mobility size (30 {le} d{sub m} {le} 300 nm), black carbon mass (0.07 {le} m{sub BC} {le} 4.2 fg) and particle chemical composition. In selected runs, particles were coated with sulfuric acid or dioctyl sebacate (DOS) (0.5 {le} {Delta}r{sub ve} {le} 201 nm) where {Delta}r{sub ve} is the change in the volume equivalent radius due to the coating material. The effect of non-absorbing coatings on instrument response was determined. Changes in the morphology of fractal soot particles were monitored during coating and denuding processes and the effect of particle shape on instrument response was determined. The combination of optical and mass based measurements was used to determine the mass specific absorption coefficient for denuded soot particles. The single scattering albedo of the particles was also measured. An overview of the experiments and sample results are presented.
Strong mobility in weakly disordered systems
We study transport of interacting particles in weakly disordered media. Our one-dimensional system includes (i) disorder, the hopping rate governing the movement of a particle between two neighboring lattice sites is inhomogeneous, and (ii) hard core interaction, the maximum occupancy at each site is one particle. We find that over a substantial regime, the root-mean-square displacement of a particle s grows superdiffusively with time t, {sigma}{approx}({epsilon}t){sup 2/3}, where {epsilon} is the disorder strength. Without disorder the particle displacement is subdiffusive, {sigma} {approx}t{sup 1/4}, and therefore disorder strongly enhances particle mobility. We explain this effect using scaling arguments, and verify the theoretical predictions through numerical simulations. Also, the simulations show that regardless of disorder strength, disorder leads to stronger mobility over an intermediate time regime.
ARM: Tandem Differential Mobility Analyzer Aerosol Particle Sizer
Tandem Differential Mobility Analyzer Aerosol Particle Sizer
Experimental investigation of the effect of inlet particle properties on the capture efficiency in an exhaust particulate filter
Not Available
Densities of internally mixed organic-inorganic particles from mobility diameter measurements of aerodynamically classified aerosols
Not Available
An Analysis of Field-Aged Diesel Particulate Filter Performance: Particle Emissions Before, During and After Regeneration
A field-aged, passive diesel particulate filter (DPF) employed in a school bus retrofit program was evaluated for emissions of particle mass and number concentration before, during and after regeneration. For the particle mass measurements, filter samples were collected for gravimetric analysis with a partial flow sampling system, which sampled proportionally to the exhaust flow. Total number concentration and number-size distributions were measured by a condensation particle counter and scanning mobility particle sizer, respectively. The results of the evaluation show that the number concentration emissions decreased as the DPF became loaded with soot. However after soot removal by regeneration, the number concentration emissions were approximately 20 times greater, which suggests the importance of the soot layer in helping to trap particles. Contrary to the number concentration results, particle mass emissions decreased from 6 1 mg/hp-hr before regeneration to 3 2 mg/hp-hr after regeneration. This indicates that nanoparticles with diameter less than 50 nm may have been emitted after regeneration since these particles contribute little to the total mass. Overall, average particle emission reductions of 95% by mass and 10,000-fold by number concentration after four years of use provided evidence of the durability of a field-aged DPF. In contrast to previous reports for new DPFs in which elevated number concentrations occurred during the first 200 seconds of a transient cycle, the number concentration emissions were elevated during the second half of the heavy-duty federal test procedure when high speed was sustained. This information is relevant for the analysis of mechanisms by which particles are emitted from field-aged DPFs.
TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - Tracegases
Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)
TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - APS
Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)