Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimization and Performance Characterization of the Second Generation Fermilab Constant Fraction Discriminator Readout ASIC

We present the optimization and performance characterization of the second-generation Fermilab Constant Fraction Discriminator ASIC (FCFD), designed for the readout of AC-coupled low-gain avalanche detector (LGAD) strip-sensors. The FCFD is explicitly engineered to be insensitive to signal-amplitude variations, thereby removing the need for time-walk correction that is required in other LGAD time-stamping readout ASICs. This updated version, referred to as FCFD1.1, incorporates several enhancements over the first iteration to address key challenges in AC-coupled LGAD front-end design. We outline the primary readout-ASIC design considerations for these applications, describe the methodology used to evaluate critical sensor and system parameters, and summarize the additionally implemented features. Performance measurements using injected charge signals and minimum-ionizing particles in test-beams demonstrate a time resolution of approximately 40 ps and a position resolution of roughly \SI{15}{\micro\meter} when tested with beam particles uniformly over the active area of the sensor.

Apresyan, Artur [Fermilab] (ORCID:0000000261860130↗

Reconstruction of the 4D beam matrix

The widely used transverse parameters characterizing particle beams are the Twiss parameters. These parameters can be measured experimentally but they do not fully characterize the beam since they do not account for possible correlations in particle distribution between two transverse coordinates. These correlations may occur due to uncompensated magnetic field at the cathode or misalignment of focusing quadrupoles in the transport beamline. We test a novel diagnostic for diagnosing full 4D beam matrix which may be used to identify such imperfections. The diagnostic is based on transporting the beam through the beamline which includes a quadrupole and a skew quadrupole magnets and measuring the resulting 2D beam distribution at the screen downstream. Such a measurement can be viewed as measuring a 2D projection of the 4D distribution. Different settings of the quads provide measurements of different slices of the phase space. The reconstruction of the original beam matrix from a number of measurements is done using machine learning algorithm, which provides a fast and reliable way of reconstruction for an arbitrary configuration of the scanning beamline. In August 2024, we set up the diagnostic beamline to perform a quadrupole scan of the beam. The setup includes a skew quadrupole, a regular quadrupole, and a screen. The images on the screen were post-processed to remove experimental artifacts and enhance contrast by eliminating background noise outside the core of the distribution=. The rms parameters of the distribution were then calculated and used as inputs for the reconstruction algorithm. This algorithm attempts to determine the initial beam matrix that produces expected images on the screen closely matching the observed images across all quadrupole settings. The algorithm found a solution in which the expected rms parameters closely align with the observations. Validation of the results is planned for FY25.

43 PARTICLE ACCELERATORS↗

Sunbeam: Near-sun statites as beam platforms for beam-driven rockets

Here, we outline a method of beamed power for propulsion that utilizes relativistic electron beams. The physics of charged particle beam propagation in the space plasma environment is discussed and the long-range (> 100 AU) advantage of relativistic electron beams is emphasized. A preliminary statite-based beam emitter for powering probes to 0.1c is proposed and the challenges in beamed-power uses are explored.

33 ADVANCED PROPULSION SYSTEMS↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for New Physics through a Long-Lived Di-Muon Resonance in the NuMI Beam with the ICARUS Detector

Many of the unexplained phenomena in particle physics and cosmology today, such as the microphysical nature of dark matter, the strong CP problem, and the origin of the neutrino masses, can be resolved by the existence of a light (~GeV), weakly-coupled hidden sector of new physics. Such hidden sectors often predict the existence of “long-lived” particles (LLPs) that travel a far distance from production before decaying into Standard Model particles. Neutrino oscillation experiments, which combine intense particle beams with precise imaging detectors, are well equipped to probe LLP models with new sensitivity. This thesis details a search for a long-lived particle decaying to two muons with the ICARUS liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino program at Fermilab. The calibration of the ICARUS time projection chamber (TPC) which enables the search is also presented. Notably, the calibration measures an angular dependence in electron-ion recombination in argon, a novel effect in the detector physics of LArTPCs. The search is performed using data taken with the Neutrinos at the Main Injector (NuMI) beam, with an exposure of 2.41e20 protons on target. No significant excess over background is observed, and we set world-leading limits on two new physics models that predict this process: the Higgs portal scalar and a heavy axion model. We also present the sensitivity in a model-independent way applicable to any new physics model predicting the process K → π + S(→μμ), for a long-lived particle S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

Toward an integrated multi-gigahertz ionizing particle diagnostic

Needs arising at both current and future accelerator facilities call for the development of radiation-hardened position-sensing diagnostics that can operate with multi-GHz repetition rates. Such instruments are likely to also have applications in the diagnosis of rapid plasma behavior. Here, building on the recent work of our Advanced Accelerator Diagnostics Collaboration, we are exploring the development of integrated multi-GHz ionizing particle detection systems based on chemical-vapor deposition diamond sensors, with the initial goal of producing a quadrant detector that can determine the intensity and centroid position of a particle beam at a repetition rate between 5 and 10 GHz. Results from our initial high-speed characterization work are presented, including those from a single-channel sensor with a GHz response. Approaches to achieving multi-GHz (5–10 GHz) rate capability, including the design of a dedicated Application Specific Integrated Circuit and the use of 3D RF-solver computer aided design software, are presented and discussed in more detail. 3D RF simulations suggest clean pulses of duration less than 250 ps (FWHM less than 125 ps) can be achieved with the approaches developed by this work.

43 PARTICLE ACCELERATORS↗

Experimental Studies of Nonlinear Integrable Optics with Elliptic Potentials

The stable transport of charged particle beams is the core challenge in designing and operating accelerators. The current paradigm for transverse focusing is based on quadrupole and dipole elements, described as a linear integrable Hamiltonian by Courant and Snyder. The operational limits of high intensity accelerators are often determined by collective instabilities within the beam. Nonlinear elements may be added to suppress certain forms of these collective effects, but restrict the range of stable trajectories. These shortcomings motivate extending to a nonlinear integrable system which can offer the benefits of suppressing collective instabilities without limiting the stable trajectories. Danilov and Nagaitsev proposed a novel nonlinear integrable system with elliptical potentials, which could be implemented as magnetic elements in an accelerator. Such a system has been implemented for practical verification in the integrable optics test accelerator (IOTA), a small storage ring constructed for beam dynamics studies. Electron beam studies in IOTA treat the low-emittance beam as a macroparticle for detailed probing of the expected single particle dynamics. This dissertation details new measurements of the nonlinear integrable system relevant for practical implementation. Turn-by-turn measurements of the kicked beam responses are used for phase space reconstruction and analysis of the predicted nonlinear dynamics. The stability and aperture for various nonlinear configurations are measured with beam losses. Amplitude dependent detuning, a core figure of merit for suppressing instabilities, is measured and compared with high fidelity particle tracking simulations. The synchrotron radiation images of circulating beam allow direct measurements of the topology and lifetime in configurations where nonlinear focusing terms dominate.

Wieland, John [Michigan U.] (ORCID:000000028971852↗

Analysis of the Blowout Plasma Wakefields Produced by Drive Beams with Elliptical Symmetry

In the underdense, or blowout regime, of plasma wakefield acceleration, the particle beam is denser than the plasma. In this scenario, the plasma electrons are nearly completely rarefied from the beam channel, leaving only a nominally uniform ion-filled “bubble.” Extensive investigations of this interaction assuming axisymmetry have been undertaken. However, the blowout produced by a transversely asymmetric (flat) driver, which would be present in linear collider “afterburner” schemes, possesses quite different characteristics. Such beams create an asymmetric plasma bubble which leads to unequal focusing in the two transverse dimensions, accompanied by a nonuniform accelerating gradient. The asymmetric blowout cross section is found through simulation to be elliptical, and treating it as such permits a simple extension of the symmetric theory. In particular, focusing fields linear in both transverse directions inside the bubble are found. The form of the wake potential and the associated beam-matching conditions in this elliptical cavity are discussed. Here, we also examine blowout boundary estimation in the long driver limit and applications of the salient asymmetric features of the wakefield.

Manwani, P. [University of California, Los Angeles↗

Geant4 RApid Pair Production Application (GRAPPA) v1.0.0

GRAPPA is a Geant4 application that simulates the interaction of an incoming particle beam (typically electron or photons) with an High-Z material. Particles are generated at a certain energy and interact with a solid target. The product of this interaction is detected and saved on file. The application implements a basic target that is just a simple box, and it accepts complex target descriptions via GDML files. The user has the freedom to set detectors to capture the desired particles. This application enables studying processes such as antiparticle production, muon generation, and atomic decay.

Terzani, Davide [Lawrence Berkeley National Labora↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

PIP-II Beam Current Monitor Fault Case & Beam Position Monitor Linearity Studies in CST Studio

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems. As such, simulations predicting the behavior of these sensors are essential for guiding beamline control system design. This poster details the results returned by two beam sensor models created using CST Studio software: the signal linearity of an elliptical beam position monitor (BPM), and the fault cases of an AC current transformer (ACCT) beam current monitor (BCM).

Rouzky, Adam↗

Electron beam characterization via quantum coherent optical magnetometry

We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturbs the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size, and total current. We tested this method for an e-beam with currents ranging from 30 to 110 μA. Our approach is insensitive to electron kinetic energy, and we confirmed that experimentally between 10 and 20 keV. In conclusion, this technique offers a unique platform for noninvasive characterization of charged particle beams used in accelerators for particle and nuclear physics research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial PIP-II Beam Current Monitor Fault Case Analyses & Beam Position Monitor Linearity Studies in CST Studio Suite

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time beam data while minimizing negative effects on beam quality. To ensure that one can be reasonably confident these sensors will behave as desired upon be-ing implemented within the beamline, simulations pre-dicting the performance of these sensors under beamline conditions can be used as a valuable tool for checking sensor functionality without a physical test bench. This paper details the design, testing, and results of two sensor models developed using CST Studio Suite soft-ware designed to mimic two sensors to be implemented within the PIP-III beamline: an elliptical, large-aperture beam position monitor (BPM) for which vertical & hori-zontal position signal linearity was analyzed, and an AC current transformer (ACCT) beam current monitor (BCM) used to search for potential fault cases within the BCM and beam pipe flange gaps. Special focus is given to the discovery of linearity variations within the BPM and the use of frequency domain techniques in the BCM fault case analyses.

Rouzky, A. R.↗

Path Length Matching and Phase control for Coherently Combined Fiber Laser Arrays (1DPATH)

Coherently combined fiber lasers are literally the future of all lasers. Through coherent combining the high efficiency, ruggedness, and low cost of fiber lasers can be synthesized into any laser imaginable. Lasers of any wavelength, pulse characteristics, energy, average power, or beam output shape can be created through the coherent combination of a low cost base fiber laser. We now have the opportunity to move from traditional “Analog” lasers with their bulk optics, big optical benches, strict cleanliness requirements and high cost and fragility towards “Digital Lasers” where the output beams are shaped to provide characteristics like Orbital Angular Momentum to not only specify the traditional laser characteristics but also the output beam patterns as well. This will enable future applications such as Wakefield Accelerators, petawatt lasers, particle beam control, as well as Inertial Confinement Fusion Drivers and a host of other medical, scientific, and industrial uses.

42 ENGINEERING↗