Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Wavelength-shifting properties of luminescence nanoparticles for high energy particle detection and specific physics process observation

Here, ultraviolet (UV) photon detection is becoming increasingly important in the quest to understand the fundamental building blocks of our universe. Basic properties of neutrinos and Dark Matter are currently being explored through interactions with noble elements. In response to interactions with fundamental particles, these elements emit scintillation photons in the UV range. However, most available detectors have poor response in the UV so it is typically necessary to shift UV to a wavelength, matching the sensitivity of the viable detectors. We report on development of UV-enhanced photosensors using wavelength-shifting properties of nanoparticles. Several nanoparticle coatings were tested for absorption of UV light with subsequent emission in the visible wavelength for high energy particle detection. ZnS:Mn, Eu, ZnS: Mn, CuCy (Copper Cysteamine) and CdTe nanoparticles all exhibited enhanced detection for wavelengths in the range 200-320 nm in several different tests, while ZnS:Ag and CdS nanoparticle showed little or no enhancement in that range. In addition, various LaF3:Ce nanoparticle concentrations in approximately constant thickness of 2,5-diphenyloxazole (PPO)/polystyrene bases were also tested to optimize the nanoparticle concentration for the best outcome. Our studies indicated that ZnS:Mn, Eu, ZnS: Mn, Cu-Cy, CdTe and LaF 3 :Ce nanoparticles show potential for light detection from fundamental particle interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method of creating structure for particle detection in time projection chambers and photodetectors

Time projection chambers are useful for high energy particle physics, nuclear physics, and astronomy. To enhance the particle detection efficiency and performance of the projection chambers functional bilayer thin film coatings based on the atomic layer deposition method are utilized. Coating material selection is based on Auger neutralization process ion induced electron emission from metallic surfaces (e.g., Mo or W) combined with a high secondary electron emission coefficient. Application of high secondary electron emission materials (e.g., MgO and CaF2) enhances the multiplication of these emitted electrons from ion induction processes. Therefore, using suitable bilayer coatings the overall TPC signal detection efficiency can be increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IonCCD™ for direct position-sensitive charged-particle detection: from electrons and keV ions to hyperthermal biomolecular ions

A novel charged-particle sensitive, pixel based detector array is described and its usage is demonstrated for a variety of applications, from detection of elemental particles (electrons) to hyper-thermal large biomolecular positive and negative ions including keV light atomic and molecular ions. The array detector is a modified light-sensitive charged coupled device (CCD). The IonCCDTM was engineered for direct charged particle detection by replacing the semi-conductor part of the CCD pixel by a conductor1. In contrast with the CCD, where the semi-conductive pixel is responsible for electron-hole pair formation upon photon bombardment, the IonCCD uses a capacitor coupled to the conductive electrode for direct charge integration. The detector can be operated from atmospheric pressure to high vacuum since no high voltages are needed. The IonCCD, presented in this work is an array of 2126 active pixels with 21 um pixel width and 3 um pixel gap. The detection area is 1.5x51mm2 where 1.5 mm and 51 mm are pixel and detector array length, respectively. The result is a one-dimensional position-sensitive detector with 24 um spatial resolution and 88 % pixel area ratio (PAR). In this work we demonstrate the capabilities and the performance of the detector. For the first time we show the direct detection of 250 eV electrons providing linearity response and detection efficiency of the IonCCD as function of electron beam current. Using positive ions from and electron impact source (E-I), we demonstrate that the detection efficiency of the IonCCD is virtually independent of particle energy [250 eV, 1250 eV], particle impact angle [45o, 90o] and particle flux. By combining the IonCCD with a double focusing sector field of Mattauch-Herzog geometry (M-H), we demonstrate fast acquisition of mass spectra in direct air sniffing mode. A first step towards fast in vivo breath analysis is presented. Detection of hyper-thermal biomolecular ions produced using an electrospray ionization source (ESI) is presented. The IonCCD was used as beam profiler to characterize the beam shape and intensity of 15 eV protonated and deprotonated biomolecular ions at the exit of an RF only collisional quadrupole. We present simultaneous detection of 140 eV doubly protonated biomolecular ions when the IonCCD is combined with the M-H analyzer. The latter, demonstrates the possibility of simultaneous separation and micro-array deposition of biological material using a miniature sector field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle detection through the quantum counter concept in YAG:Er{sup 3+}

We report on a scheme for particle detection based on the infrared quantum counter concept. Its operation consists of a two-step excitation process of a four level system, which can be realized in rare earth-doped crystals when a cw pump laser is tuned to the transition from the second to the fourth level. The incident particle raises the atoms of the active material into a low lying, metastable energy state, triggering the absorption of the pump laser to a higher level. Following a rapid non-radiative decay to a fluorescent level, an optical signal is observed with a conventional detector. In order to demonstrate the feasibility of such a scheme, we have investigated the emission from the fluorescent level {sup 4}S{sub 3∕2} (540 nm band) in an Er{sup 3+}-doped YAG crystal pumped by a tunable titanium sapphire laser when it is irradiated with 60 keV electrons delivered by an electron gun. We have obtained a clear signature that this excitation increases the {sup 4}I{sub 13∕2} metastable level population that can efficiently be exploited to generate a detectable optical signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micron-Sized Dust Particles Detected in the Outer Solar System by the Voyager 1 and 2 Plasma Wave Instruments

During the Voyager 1 and 2 flybys of the outer planets it has been demonstrated that the plasma wave instrument can detect small dust particles striking the spacecraft. In this paper, we examine the Voyager plasma wave data for dust impacts in the interplanetary medium at heliocentric radial distances ranging from 6 to 60 astronomical units (AU). The results show that a small but persistent level of dust impacts exists out to at least 30 to 50 AU. The average number density of these particles is about 2 x 10(exp -8)/cu m, and the average mass of the impacting particles is believed to be a few times 10(exp -11) g, which corresponds to particle diameters in the micron range. Possible sources of these particles are planets, moons, asteroids, comets, and the interstellar medium. Of these, comets appear to be the most likely source. The number densities are only weakly dependent on ecliptic latitude, which indicates that the particles probably do not originate from planets, moons, or asteroids. Comparisons with interstellar dust fluxes measured in the inner regions of the solar system by the Ulysses spacecraft indicate that the particles are not of interstellar origin.

Gurnett, D. A.↗

Micron-Sized Dust Particles Detected in the Outer Solar System by the Voyager 1 and 2 Plasma Wave Instruments

During the Voyager 1 and 2 flybys of the outer planets it has been demonstrated that the plasma wave instrument can detect small dust particles striking the spacecraft. In this paper, we examine the Voyager plasma wave data for dust impacts in the interplanetary medium at heliocentric radial distances ranging from 6 to 60 astronomical units (AU). The results show that a small but persistent level of dust impacts exists out to at least 30 to 50 AU. The average number density of these particles is about 2 x 10(exp -8)/cu m, and the average mass of the impacting particles is believed to be a few times 10(exp -11) g, which corresponds to particle diameters in the micron range. Possible sources of these particles are planets, moons, asteroids, comets, and the interstellar medium. Of these, comets appear to be the most likely source. ne number densities are only weakly dependent on ecliptic latitude, which indicates that the particles probably do not originate from planets, moons, or asteroids. Comparisons with interstellar dust fluxes measured in the inner regions of the solar system by the Ulysses spacecraft indicate that the particles are not of interstellar origin.

Gurnett, D. A.↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

A Low-power CMOS Front End for Particle Detection Applications

A complete low-power front end integrates a charge sensitive amplifier with a novel adaptive biasing scheme which allows the DC bias currents to be scaled below conventional limits, with a peak detector circuit obtaining a peak value for each detection event which is then converted to digital via an 8 bit charge-redistribution successive approximation analog to digital converter. The ADC is shut off between detection events to reduce power consumption even more. The low power circuit consumes between 39muW and 400muW of power depending on the particle detection rate.

Schemm, Nathan↗

High energy particle detection with large area superconducting microwire array

We present the first detailed study of an 8-channel2×2 mm$^{2}$ WSi superconducting microwire single photondetector (SMSPD) array exposed to 120 GeV proton beam and 8 GeVelectron and pion beam at the Fermilab Test Beam Facility. TheSMSPD detection efficiency was measured for the first time forprotons, electrons, and pions, enabled by the use of a silicontracking telescope that provided precise spatial resolution of30 μm for 120 GeV protons and 130 μm for 8 GeVelectrons and pions. The result demonstrated consistent detectionefficiency across pixels and at different bias currents. Timeresolution of 1.15 ns was measured for the first time for SMSPDwith proton, electron, and pions, enabled by the use of an MCP-PMTwhich provided a ps-level reference time stamp. The resultspresented is the first step towards developing SMSPD array systemsoptimized for high energy particle detection and identification forfuture accelerator-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle detection and non-detection in a quantum time of arrival measurement

The standard time-of-arrival distribution cannot reproduce both the temporal and the spatial profile of the modulus squared of the time-evolved wave function for an arbitrary initial state. In particular, the time-of-arrival distribution gives a non-vanishing probability even if the wave function is zero at a given point for all values of time. This poses a problem in the standard formulation of quantum mechanics where one quantizes a classical observable and uses its spectral resolution to calculate the corresponding distribution. In this work, we show that the modulus squared of the time-evolved wave function is in fact contained in one of the degenerate eigenfunctions of the quantized time-of-arrival operator. This generalizes our understanding of quantum arrival phenomenon where particle detection is not a necessary requirement, thereby providing a direct link between time-of-arrival quantization and the outcomes of the two-slit experiment. -- Highlights: •The time-evolved position density is contained in the standard TOA distribution. •Particle may quantum mechanically arrive at a given point without being detected. •The eigenstates of the standard TOA operator are linked to the two-slit experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Magnetic particle detection in unshielded environment using orthogonal fluxgate gradiometer

A new detection system for magnetic particles, which can operate in an unshielded environment, is developed using a fundamental mode orthogonal fluxgate gradiometer. The proposed detection system offers the advantages of cost, size, and weight reduction as compared to contamination detection systems using superconducting quantum interference device sensor. The detection system can be used to detect metallic contamination in foods or lithium ion battery production lines. The system has been investigated numerically to optimize various design parameters of the system. Experimental setup has been developed to evaluate some of the numerically predicted results. Steel balls were successfully detected down to the diameter of 50 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Loose Particle Detection

PIND, developed by Dunegan/Endevco is an acronym for Particle Impact Noise Detection, a means of finding tiny, loose conductive particles introduced during fabrication of integrated circuits, which sometimes cause system failures. One type of automated system used for PIND testing has undergone a study by Goddard Space Flight Center to determine its effectiveness. Analysis of the test data indicated that an average PIND detection capability of about 45 percent can be expected.

Source record↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

Qualification of the T2 wind tunnel in cryogenic operation. B: Flow fluctuations, particle detection and qualification

This report presents part of the tests for verification of the T2 transonic induction wind tunnel in cryogenic operation. The first part of the results presented concerns fluctuations in pressure and temperature at ambient temperature and in cryogenic regulation. The second part presents the condensation phenomena which could be observed in the cryogenic flow by means of an optical particle detection system in the test section.

Dor, J. B.↗