Search NASA⌕ Search

SEARCH · Search NASA

Results for “Patient Support System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Compact and mobile high resolution PET brain imager

A brain imager includes a compact ring-like static PET imager mounted in a helmet-like structure. When attached to a patient's head, the helmet-like brain imager maintains the relative head-to-imager geometry fixed through the whole imaging procedure. The brain imaging helmet contains radiation sensors and minimal front-end electronics. A flexible mechanical suspension/harness system supports the weight of the helmet thereby allowing for patient to have limited movements of the head during imaging scans. The compact ring-like PET imager enables very high resolution imaging of neurological brain functions, cancer, and effects of trauma using a rather simple mobile scanner with limited space needs for use and storage.

47 OTHER INSTRUMENTATION↗

Architecture-Level Dependability Analysis of a Medical Decision Support System

Recent advances in techniques such as image analysis, text analysis and machine learning have shown great potential to assist physicians in detecting and diagnosing health issues in patients. In this paper, we describe the approach and findings of an architecture-level dependability analysis for a mammography decision support system that incorporates these techniques. The goal of the research described in this paper is to provide an initial understanding of the dependability issues, particularly the potential failure modes and severity, in order to identify areas of potential high risk. The results will guide design decisions and provide the basis of a dependability and performance evaluation program.

99 GENERAL AND MISCELLANEOUS↗

Physiologic and thermal responses of male and female patients with multiple sclerosis to head and neck cooling

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the thermal and physiologic responses of patients with multiple sclerosis to short-term maximal head and neck cooling. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 24 female and 26 male patients with multiple sclerosis in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 degrees C), were cooled for 30 min by the liquid cooling garment, which was operated at its maximum cooling capacity. Oral, right, and left ear temperatures and cooling system parameters were logged manually every 5 min. Forearm, calf, chest, and rectal temperatures, heart rate, and respiration rate were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. This protocol was performed during the winter and summer to investigate the seasonal differences in the way patients with multiple sclerosis respond to head and neck cooling. No significant differences were found between the male and female subject group's mean rectal or oral temperature responses during any phase of the experiment. The mean oral temperature decreased significantly (P < 0.05) for both groups approximately 0.3 degrees C after 30 min of cooling and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 15 min after removal of the cooling helmet. The mean rectal temperatures decreased significantly (P < 0.05) in both male and female subjects in the winter studies (approximately 0.2-0.3 degrees C) and for the male subjects during the summer test (approximately 0.2 degrees C). However, the rectal temperature of the female subjects did not change significantly during any phase of the summer test. These data indicate that head and neck cooling may, in general, be used to reduce the oral and body temperatures of both male and female patients with multiple sclerosis by the approximate amount needed for symptomatic relief as shown by other researchers. However, thermal response of patients with multiple sclerosis may be affected by gender and seasonal factors, which should be considered in the use of liquid cooling therapy.

NASA Discipline Environmental Health↗

SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-02: Automatic Planning as a Potential Strategy for Dose Escalation for Pancreas SBRT?

Purpose: Stereotactic body radiation therapy (SBRT) has been suggested to provide high rates of local control for locally advanced pancreatic cancer. However, the close proximity of highly radiosensitive normal tissues usually causes the labor-intensive planning process, and may impede further escalation of the prescription dose. The present study evaluates the potential of an automatic planning system as a dose escalation strategy. Methods: Ten pancreatic cancer patients treated with SBRT were studied retrospectively. SBRT was delivered over 5 consecutive fractions with 6 ∼ 8Gy/fraction. Two plans were generated by Pinnacle Auto-Planning with the original prescription and escalated prescription, respectively. Escalated prescription adds 1 Gy/fraction to the original prescription. Manually-created planning volumes were excluded in the optimization goals in order to assess the planning efficiency and quality simultaneously. Critical organs with closest proximity were used to determine the plan normalization to ensure the OAR sparing. Dosimetric parameters including D100, and conformity index (CI) were assessed. Results: Auto-plans directly generate acceptable plans for 70% of the cases without necessity of further improvement, and two more iterations at most are necessary for the rest of the cases. For the pancreas SBRT plans with the original prescription, autoplans resulted in favorable target coverage and PTV conformity (D100 = 96.3% ± 1.48%; CI = 0.88 ± 0.06). For the plans with the escalated prescriptions, no significant target under-dosage was observed, and PTV conformity remains reasonable (D100 = 93.3% ± 3.8%, and CI = 0.84 ± 0.05). Conclusion: Automatic planning, without substantial human-intervention process, results in reasonable PTV coverage and PTV conformity on the premise of adequate OAR sparing for the pancreas SBRT plans with escalated prescription. The results highlight the potential of autoplanning as a dose escalation strategy for pancreas SBRT treatment planning. Further investigations with a larger number of patients are necessary. The project is partially supported by Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

Two-Stage Adaptive Restoration Decision Support System for a Self-Healing Power Grid

Power outages cost American industries and businesses billions of dollars and jeopardize the lives of hospital patients. The losses can be greatly reduced with a fast, reliable, and flexible self-healing tool. This paper is aimed to tackle the challenging task of developing an adaptive restoration decision support system (RDSS). The proposed RDSS determines restoration actions both in planning and real-time phases and adapts to constantly changing system conditions. The comprehensive formulation encompasses practical constraints including ac power flow, dynamic reserve, and load modeling. Here, the combinatorial problem is decomposed into a two-stage formulation solved by an integer L-shaped algorithm. The two stages are then executed online in the RDSS framework employing a sliding window method. The IEEE 39-bus system has been studied under normal and contingency conditions to demonstrate the effectiveness and efficiency of the proposed online RDSS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-590: An Activation Study of Materials and Devices Present in a Proton Treatment Room

Purpose: The use of protons for radiation therapy is growing rapidly. One consequence of protons interacting with different media is activation. These nuclear reactions induced by the protons, scattered neutrons, and gamma rays, activate different materials encountered, particularly by the therapists. The purpose of this study was to examine the derived nuclides from the activation, and also the decay rate. Methods: The study was conducted in our proton therapy facility. Protons are derived from a synchrocyclotron and pass through field shipping systems, apertures, and range compensators to define the beam within the patient.Included materials of concerns measured; the patient support couch, sheet rock in the wall, solid plastics used for quality assurance and dosimetry, and the passive scattering system itself, which includes brass apertures, and Lucite or blue wax compensators. All devices were studied post irradiation using gamma spectroscopy to determine the nuclides, and a sodium iodine scintillation detector to measure decay, particularly when the dose rate fell to background levels. Results: We have also determined from the measurements we will maintain brass apertures for three months before sending them for scrap. Some of the radionuclides arrived from these measurements included Na-22 for the blue wax compensator, C1-34m for the sheetrock, and Sc-44 and Co-60 for the brass apertures. We found compensators made out of Lucite or wax decayed to background in 2 hours. The patient support couch decayed to background in approximately 40 minutes, and sheet rock decayed in 80 minutes. In terms of the aperture layers, the most proximal aperture slab had much higher activity than the distal slab. Also the proximal sides of the slabs were much more activate than the distal. Conclusion: We have given proper instruction to therapists performing quality assurance in terms of the handled plastics, and to handle apertures rapidly as possible.

07 ISOTOPE AND RADIATION SOURCES↗

A Review of Nonscaling CW FFAs for Proton and Ion Therapy Applications

Significant progress on compact, variable-energy versions of non-scaling fixed field accelerators with alternating strong-focusing gradients (nsFFA) has been made and adapted to proton and ion therapy. Not only has isochronous (CW) capability been demonstrated in a realizable design, an isochronous racetrack format has evolved which supports lengthy, synchrotron-like straight sections. Long straight insertions promote low-loss injection and extraction systems and further facilitate extracting lower-energy orbits using a bipolar bump-magnet system. To efficiently extract variable energy using this method, the accelerator complex requires separated accelerator stages, each stage with limited but therapeutically optimized energy ranges targeting specific cancer types and penetration depths. Different energy stages further support multiple treatment rooms increasing patient throughput and reducing treatment cost. The staged system proposed here also realizes cost savings in gantries by tailoring delivery to different therapeutic energies and beam requirements, promoting the requirement for only one high-energy gantry in the facility. The proposed facility consists of 3 stages, a 30 MeV injector, a 30 - 90 MeV/nucleon FFA for shallow cancers, and 90 - 250/330 MeV/nucleon stage for deep tumors, pelvis for example. The higher energy of the final stage, 330 MeV/nucleon is preferred to support Proton Computed Tomography. Isochronous FFA stages can be designed to accelerate either protons or ions with charge to mass of 1/2.

43 PARTICLE ACCELERATORS↗

Feasibility of Patient Reporting of Symptomatic Adverse Events via the Patient-Reported Outcomes Version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE) in a Chemoradiotherapy Cooperative Group Multicenter Clinical Trial

Purpose: To assess the feasibility of measuring symptomatic adverse events (AEs) in a multicenter clinical trial using the National Cancer Institute's Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE). Methods and Materials: Patients enrolled in NRG Oncology's RTOG 1012 (Prophylactic Manuka Honey for Reduction of Chemoradiation Induced Esophagitis-Related Pain during Treatment of Lung Cancer) were asked to self-report 53 PRO-CTCAE items representing 30 symptomatic AEs at 6 time points (baseline; weekly ×4 during treatment; 12 weeks after treatment). Reporting was conducted via wireless tablet computers in clinic waiting areas. Compliance was defined as the proportion of visits when an expected PRO-CTCAE assessment was completed. Results: Among 226 study sites participating in RTOG 1012, 100% completed 35-minute PRO-CTCAE training for clinical research associates (CRAs); 80 sites enrolled patients, of which 34 (43%) required tablet computers to be provided. All 152 patients in RTOG 1012 agreed to self-report using the PRO-CTCAE (median age 66 years; 47% female; 84% white). Median time for CRAs to learn the system was 60 minutes (range, 30-240 minutes), and median time for CRAs to teach a patient to self-report was 10 minutes (range, 2-60 minutes). Compliance was high, particularly during active treatment, when patients self-reported at 86% of expected time points, although compliance was lower after treatment (72%). Common reasons for noncompliance were institutional errors, such as forgetting to provide computers to participants; patients missing clinic visits; Internet connectivity; and patients feeling “too sick.” Conclusions: Most patients enrolled in a multicenter chemoradiotherapy trial were willing and able to self-report symptomatic AEs at visits using tablet computers. Minimal effort was required by local site staff to support this system. The observed causes of missing data may be obviated by allowing patients to self-report electronically between visits, and by using central compliance monitoring. These approaches are being incorporated into ongoing studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trauma Pod: A Semi-Automated Robotic Surgery System

The Trauma Pod (TP) vision is to develop a rapidly deployable robotic system to perform critical acute stabilization and/or surgical procedures autonomously or in a teleoperative mode on wounded soldiers in the battlefield who might otherwise die before treatment in a combat hospital can be provided. In the first phase of a project pursuing this vision, a robotic TP system was developed and its capability demonstrated by performing select surgical procedures on a patient phantom. The system demonstrates the feasibility of performing acute stabilization procedures with the patient being the only human in the surgical cell. The teleoperated surgical robot is supported by autonomous arms that carry out scrub-nurse and circulating-nurse functions. Tool change and supply delivery are performed automatically and at least as fast as those performed manually by nurses. The TP system also includes tomographic X-ray facility for patient diagnosis and 2-D fluoroscopic data to support interventions. The vast amount of clinical protocols generated in the TP system are recorded automatically. These capabilities form the basis for a more comprehensive acute diagnostic and management platform that will provide life-saving care in environments where surgical personnel are not present.

42 ENGINEERING↗

Determining the impacts of venoarterial extracorporeal membrane oxygenation on cerebral oxygenation using a one-dimensional blood flow simulator

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a mechanical system that provides rapid and short-term support for patients with cardiac failure. In many patients, pulmonary function is also impaired, resulting in poorly-oxygenated cardiac outflow competing against well-oxygenated VA-ECMO outflow, a condition known as North-South syndrome. North-South syndrome is a primary concern because of its potential to cause cerebral hypoxia, which has a critical influence on neurological complications often seen in this patient population. In order to reduce ischemic neurological complications, it is important to understand how clinical decisions regarding VA-ECMO parameters influence blood oxygenation. In our work, we studied the impacts of flow rate and cannulation site on oxygenation using a one-dimensional (1D) model to simulate blood flow. Our model was initially tested by comparing blood flow results to those observed from experimental work in VA-ECMO patients. The 1D model was combined with a two-phase flow model to simulate oxygenation. Additionally, the influence of various other clinician-tunable parameters on oxygenation in the common carotid arteries (CCAs) were tested, including, blood viscosity, cannula position within the insertion artery, heart rate, and systemic vascular resistance (SVR), as well as geometrical changes such as arterial radius and length. Our results indicated that blood oxygenation to the brain strongly depended on the cannula insertion site and the VA-ECMO flow rate with a weaker but potentially significant dependence on arterial radius. During femoral cannulation, VA-ECMO flow rates greater than ~4.9 L/min were needed to perfuse the CCAs. However, axillary and central cannulation began to perfuse the CCAs at significantly lower flow (~1 L/min). These results may help explain the incidence of cerebral hypoxia in this patient population and the common need to change cannulation strategies during treatment to address this clinical problem. While this work describes patient-averaged results, determining these relationships between VA-ECMO parameters and cerebral hypoxia is an important step towards future work to develop patient-specific models that clinicians can use to improve outcomes.

1D blood flow↗

SU-E-T-754: Three-Dimensional Patient Modeling Using Photogrammetry for Collision Avoidance

Purpose: To evaluate photogrammetry for creating a three-dimensional patient model. Methods: A mannequin was configured on the couch of a CT scanner to simulate a patient setup using an indexed positioning device. A CT fiducial was placed on the indexed CT table-overlay at the reference index position. Two dimensional photogrammetry targets were placed on the table in known positions. A digital SLR camera was used to obtain 27 images from different positions around the CT table. The images were imported into a commercial photogrammetry package and a 3D model constructed. Each photogrammetry target was identified on 2 to 5 images. The CT DICOM metadata and the position of the CT fiducial were used to calculate the coordinates of the photogrammetry targets in the CT image frame of reference. The coordinates were transferred to the photogrammetry software to orient the 3D model. The mannequin setup was transferred to the treatment couch of a linear accelerator and positioned at isocenter using in-room lasers. The treatment couch coordinates were noted and compared with prediction. The collision free regions were measured over the full range of gantry and table motion and were compared with predictions obtained using a general purpose polygon interference algorithm. Results: The reconstructed 3D model consisted of 180000 triangles. The difference between the predicted and measured couch positions were 5 mm, 1 mm, and 1 mm for longitudinal, lateral, and vertical, respectively. The collision prediction tested 64620 gantry table combinations in 11.1 seconds. The accuracy was 96.5%, with false positive and negative results occurring at the boundaries of the collision space. Conclusion: Photogrammetry can be used as a tool for collision avoidance during treatment planning. The results indicate that a buffer zone is necessary to avoid false negatives at the boundary of the collision-free zone. Testing with human patients is underway. Research partially supported by a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Detection of Local Cancer Recurrence After Stereotactic Ablative Radiation Therapy for Lung Cancer: Physician Performance Versus Radiomic Assessment

Purpose: Stereotactic ablative radiation therapy (SABR) is a guideline-specified treatment option for early-stage lung cancer. However, significant posttreatment fibrosis can occur and obfuscate the detection of local recurrence. The goal of this study was to assess physician ability to detect timely local recurrence and to compare physician performance with a radiomics tool. Methods and Materials: Posttreatment computed tomography (CT) scans (n=182) from 45 patients treated with SABR (15 with local recurrence matched to 30 with no local recurrence) were used to measure physician and radiomic performance in assessing response. Scans were individually scored by 3 thoracic radiation oncologists and 3 thoracic radiologists, all of whom were blinded to clinical outcomes. Radiomic features were extracted from the same images. Performances of the physician assessors and the radiomics signature were compared. Results: When taking into account all CT scans during the whole follow-up period, median sensitivity for physician assessment of local recurrence was 83% (range, 67%-100%), and specificity was 75% (range, 67%-87%), with only moderate interobserver agreement (κ = 0.54) and a median time to detection of recurrence of 15.5 months. When determining the early prediction of recurrence within <6 months after SABR, physicians assessed the majority of images as benign injury/no recurrence, with a mean error of 35%, false positive rate (FPR) of 1%, and false negative rate (FNR) of 99%. At the same time point, a radiomic signature consisting of 5 image-appearance features demonstrated excellent discrimination, with an area under the receiver operating characteristic curve of 0.85, classification error of 24%, FPR of 24%, and FNR of 23%. Conclusions: These results suggest that radiomics can detect early changes associated with local recurrence that are not typically considered by physicians. This decision support system could potentially allow for early salvage therapy of patients with local recurrence after SABR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Validated Prediction Model for Overall Survival From Stage III Non-Small Cell Lung Cancer: Toward Survival Prediction for Individual Patients

Purpose: Although patients with stage III non-small cell lung cancer (NSCLC) are homogeneous according to the TNM staging system, they form a heterogeneous group, which is reflected in the survival outcome. The increasing amount of information for an individual patient and the growing number of treatment options facilitate personalized treatment, but they also complicate treatment decision making. Decision support systems (DSS), which provide individualized prognostic information, can overcome this but are currently lacking. A DSS for stage III NSCLC requires the development and integration of multiple models. The current study takes the first step in this process by developing and validating a model that can provide physicians with a survival probability for an individual NSCLC patient. Methods and Materials: Data from 548 patients with stage III NSCLC were available to enable the development of a prediction model, using stratified Cox regression. Variables were selected by using a bootstrap procedure. Performance of the model was expressed as the c statistic, assessed internally and on 2 external data sets (n=174 and n=130). Results: The final multivariate model, stratified for treatment, consisted of age, gender, World Health Organization performance status, overall treatment time, equivalent radiation dose, number of positive lymph node stations, and gross tumor volume. The bootstrapped c statistic was 0.62. The model could identify risk groups in external data sets. Nomograms were constructed to predict an individual patient's survival probability ( (www.predictcancer.org)). The data set can be downloaded at (https://www.cancerdata.org/10.1016/j.ijrobp.2015.02.048). Conclusions: The prediction model for overall survival of patients with stage III NSCLC highlights the importance of combining patient, clinical, and treatment variables. Nomograms were developed and validated. This tool could be used as a first building block for a decision support system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The anemia of primary autonomic failure and its reversal with recombinant erythropoietin

OBJECTIVE: To determine if chronic sympathetic deprivation is associated with anemia and a low erythropoietin response. DESIGN: Survey of the prevalence and characteristics of anemia in patients with severe primary autonomic failure. SETTING: A referral service for autonomic failure in a tertiary teaching hospital. PATIENTS: 84 patients with primary autonomic failure who had symptomatic orthostatic hypotension. INTERVENTION: Open-label trial with human recombinant erythropoietin. RESULTS: Anemia was present in 32 of 84 patients (38%; 95% Cl, 27% to 50%). Plasma norepinephrine levels, measured in patients standing upright, were lower in the patient group with lower hemoglobin levels. Mean values in 22 patients with a hemoglobin level of less than 120 g/L were as follows: hemoglobin, 108 g/L (range, 87 to 118 g/L); hematocrit, 0.33; corrected reticulocyte counts, 0.008; mean corpuscular volume, 89 fL (89 microns 3); serum iron, 16.5 mumol/L (92 micrograms/dL); total iron binding capacity, 43.3 mumol/L (242 micrograms/dL); ferritin, 184 micrograms/L; serum vitamin B12, 410 pmol/L (556 pg/mL); and serum folate, 22.7 nmol/L (10 ng/mL). No relation was found between serum erythropoietin and blood hemoglobin levels. In seven of nine patients with autonomic failure who had hemoglobin levels less than 120 g/L, serum erythropoietin levels decreased below the 95% confidence interval corresponding to patients with iron deficiency anemia. Therapy with recombinant erythropoietin improved mean hemoglobin levels (from 108 to 133 g/L) in all patients treated (n = 5) at relatively low doses (25 to 50 units/kg body weight, subcutaneously, three times a week). CONCLUSIONS: Our data support the hypothesis that the sympathetic nervous system stimulates erythropoiesis in humans because anemia is a frequent occurrence in patients with severe autonomic failure and is associated with a blunted erythropoietin response.

Clinical Trial↗

SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-F-T-503: Trajectory Modulated Arc Therapy of Intracranial Lesions: Development of a Standardized Path-Based Technique for Fully Dynamic Couch-Gantry Modulated Treatments

Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling the formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Explainable Artificial Intelligence in Endocrinological Medical Research

Artificial Intelligence (AI) has been a part of the medical community for decades in the form of Clinical Decision Support Systems (CDSS) to aide physicians in diagnosis and categorization of patients (1). Recent years have seen a shift from expert-derived models to the integration of machine learning (ML) algorithms to drive the output of these AI systems due to the ability of ML models to more accurately make predictions by exploiting higher dimensional and often complex data. In many cases ML models gain their advantage in accuracy by capture complex and often non-linear relationships between features being used to make the prediction. However, the hype and excitement around these methods are tempered by the clinical utility of often black-box solutions driven by skepticism of results that are difficult for practitioners to not only interpret but explain to their patients (1-3). This skepticism is not unfounded as multiple examples of black-box solutions identifying incidental correlates as the key predictors have highlighted the potential bias in a training set, or reward system, that a ML model may exploit; for example a model discerning wolves from huskies based on snow in the background rather than features of the dogs (1, 4, 5).

Endocrinological, artificial intelligence, diabete↗