Lightweight Trauma Module - LTM

Current patient movement items (PMI) supporting the military's Critical Care Air Transport Team (CCATT) mission as well as the Crew Health Care System for space (CHeCS) have significant limitations: size, weight, battery duration, and dated clinical technology. The LTM is a small, ~20 lb., system integrating diagnostic and therapeutic clinical capabilities along with onboard data management, communication services and automated care algorithms to meet new Aeromedical Evacuation requirements. The Lightweight Trauma Module is an Impact Instrumentation, Inc. project with strong Industry, DoD, NASA, and Academia partnerships aimed at developing the next generation of smart and rugged critical care tools for hazardous environments ranging from the battlefield to space exploration. The LTM is a combination ventilator/critical care monitor/therapeutic system with integrated automatic control systems. Additional capabilities are provided with small external modules.

Hatfield, Thomas↗

Determining the IV fluids required for a ten day medical emergency on Space Station Freedom - Comparison of packaged vs. on-orbit produced solutions

To aid planning for the storage of supplies onboard Space Station Freedom, an estimate was made of the amount of intravenous (IV) fluid required to support a patient who has suffered a medical emergency for a period of up to 10 days. Six different medical scenarios were evaluated, and the volume of IV fluids required for each scenario was estimated. Up to 220 liters of fluid would be required to support a patient for all of the scenarios. When optimizing the volumes to support any single scenario, a total of 123 liters is required. Use of a water polishing system to produce sterile water for injection from potable supplies and on-station formulation of IV fluids results in a smaller mass and volume requirement for the Fluid Therapy Subsystem than carrying prepackaged bags of fluid.

Creager, Gerald J.↗

Preliminary Design of an 'Autonomous Medical Response Agent' Interface Prototype for Long Duration Spaceflight

Major challenges for astronauts in future long-duration exploration missions (LDEMs) will be that crewmembers are not expected to be medical professionals, may be under high workload and stress, are facing physiological challenges caused by spaceflight, and will have limited, delayed voice communications with medical support from Earth. An autonomous medical response agent (AMRA) is envisioned to help astronauts address medical complaints, develop a differential diagnosis, and guide self-treatment until a healthy state is restored. AMRA develops a process of personalized diagnosis and treatment through a Bayesian predictive control system that recommends therapeutic control actions including diagnostic tests and treatments to crewmembers (Menon, 2020). The Human Computer Interaction (HCI) lab from NASA Ames Research Center’s Human Systems Integration Division (Code TH) has collaborated with Nahlia Inc in human-centered design augmentation research for AMRA. The project, titled Design of ‘Autonomous Medical Response Agent Interface Prototype for Long Duration Spaceflight, has been funded by the Translational Research Institute for Space Health (TRISH) and introduces an interactive user-interface prototype that guides astronauts through self-diagnosis, treatment, and rehabilitation while communicating with remote specialists in ground support (most notably a patient’s flight surgeon). Our project develops the interaction design for the crewmember using AMRA through user research, iterative design, and usability testing to evaluate the user interface and workflow designed. The interface design deliverable for this project, titled AMRA Aggregate Information Display (AMRA AID) is an integrated information display system for comprehensive autonomous medical guidance, diagnosis, and treatment of in-flight medical conditions experienced by crewmembers. AMRA AID demonstrates how we might ensure crew autonomy, increase the crew’s medical capabilities, and decrease cognitive burden within a front-end user interface. AMRA AID refrains from relying on input from ground or mission control for self-treatment of medical issues—though ground awareness and communication with ground is maintained as a means of ensuring trust between mission control and crew. AMRA AID demonstrates how the crew’s on-board medical system might integrate with information from vehicle monitoring and crew schedule, without assuming causal relationships. AMRA AID’s comprehensive view enables efficient information access for both crew and ground support, reducing cognitive burden in the event of an unplanned or emergency medical incident and enabling informed analytical decisions to be made based on both crew and vehicle health. Human-centered design augmentation advanced within the prototype included: enhanced workflow and treatment guidance for two medical scenarios for a non-specialist user base with various levels of medical training, interaction design which considered speech (conversational user interface) elements and on-screen interactions to be developed in future iterations of the project, communication design and functional requirements relevant to self-care versus caring for another astronaut, as well as user testing of the prototype with an international space medical community. This project arrives at critical findings regarding usability needs, communication requirements, and integrated information requirements for a future technology interface functioning to increase confidence between ground support and LDEM crewmembers.

TRISH↗

User and Task Analysis of the Flight Surgeon Console at the Mission Control Center of the NASA Johnson Space Center

Astronauts in a space station are to some extent like patients in an intensive care unit (ICU). Medical support of a mission crew will require acquisition, transmission, distribution, integration, and archiving of significant amounts of data. These data are acquired by disparate systems and will require timely, reliable, and secure distribution to different communities for the execution of various tasks of space missions. The goal of the Comprehensive Medical Information System (CMIS) Project at Johnson Space Center Flight Medical Clinic is to integrate data from all Medical Operations sources, including the reference information sources and the electronic medical records of astronauts. A first step toward the full CMIS implementation is to integrate and organize the reference information sources and the electronic medical record with the Flight Surgeons console. In order to investigate this integration, we need to understand the usability problems of the Flight Surgeon's console in particular and medical information systems in general. One way to achieve this understanding is through the use of user and task analyses whose general purpose is to ensure that only the necessary and sufficient task features that match users capacities will be included in system implementations. The goal of this summer project was to conduct user and task analyses employing cognitive engineering techniques to analyze the task of the Flight Surgeons and Biomedical Engineers (BMEs) while they worked on Console. The techniques employed were user interviews, observations and a questionnaire to collect data for which a hierarchical task analysis and an information resource assessment were performed. They are described in more detail below. Finally, based on our analyses, we make recommendations for improvements to the support structure.

Johnson, Kathy A.↗

Hybrid vision activities at NASA Johnson Space Center

NASA's Johnson Space Center in Houston, Texas, is active in several aspects of hybrid image processing. (The term hybrid image processing refers to a system that combines digital and photonic processing). The major thrusts are autonomous space operations such as planetary landing, servicing, and rendezvous and docking. By processing images in non-Cartesian geometries to achieve shift invariance to canonical distortions, researchers use certain aspects of the human visual system for machine vision. That technology flow is bidirectional; researchers are investigating the possible utility of video-rate coordinate transformations for human low-vision patients. Man-in-the-loop teleoperations are also supported by the use of video-rate image-coordinate transformations, as researchers plan to use bandwidth compression tailored to the varying spatial acuity of the human operator. Technological elements being developed in the program include upgraded spatial light modulators, real-time coordinate transformations in video imagery, synthetic filters that robustly allow estimation of object pose parameters, convolutionally blurred filters that have continuously selectable invariance to such image changes as magnification and rotation, and optimization of optical correlation done with spatial light modulators that have limited range and couple both phase and amplitude in their response.

Juday, Richard D.↗

Space-Proven Medical Monitor: The Total Patient-Care Package

The primary objective of the Gemini Program was to develop techniques that would allow for advanced, long-duration space travel, a prerequisite of the ensuing Apollo Program that would put man safely on the Moon before the end of the decade. In order to carry out this objective, NASA worked with a variety of innovative companies to develop propulsion systems, onboard computers, and docking capabilities that were critical to the health of Gemini spacecraft, as well as life-support systems and physiological-monitoring devices that were critical to the health of Gemini astronauts. One of these companies was Spacelabs Medical, Inc., the pioneer of what is commonly known today as medical telemetry. Spacelabs Medical helped NASA better understand man s reaction to space through a series of bioinstrumentation devices that, for the first time ever, were capable of monitoring orbiting astronauts physical conditions in real time, from Earth. The company went on to further expand its knowledge of monitoring and maintaining health in space, and then brought it down to Earth, to dramatically change the course of patient monitoring in the field of health care.

Source record↗

Medics: Medical Decision Support System for Long-Duration Space Exploration

The Autonomous Medical Operations (AMO) group at NASA Ames is developing a “medical decision support system” to enable astronauts on long-duration exploration missions to operate autonomously. The system will support clinical actions by providing medical interpretation advice and procedural recommendations during emergent care and clinical work performed by crew. The current state of development of the system, called MedICS (Medical Interpretation Classification and Segmentation) includes two separate aspects: a set of machine learning diagnostic models trained to analyze organ images and patient health records, and an interface to ultrasound diagnostic hardware and to medical repositories. Three sets of images of different organs and medical records were utilized for training machine learning models for various analyses, as follows: 1. Pneumothorax condition (collapsed lung). The trained model provides a positive or negative diagnosis of the condition. 2. Carotid artery occlusion. The trained model produces a diagnosis of 5 different occlusion levels (including “normal”). 3. Ocular retinal images. The model extracts optic disc pixels (image segmentation). This is a precursor step for advanced autonomous fundus clinical evaluation algorithms to be implemented in FY20. 4. Medical health records. The model produces a differential diagnosis for any particular individual, based on symptoms and other health and demographic information. A probability is calculated for each of 25 most common conditions. The same model provides the likelihood of survival. All results are provided with a confidence level. Item 1 images were provided by the US Army and were part of a data set for the clinical treatment of injured battlefield soldiers. This condition is relevant to possible space mishaps, due to pressure management issues. Item 2 images were provided by Houston Methodist Hospital, and item 3 health records were acquired from the MIT laboratory of computational physiology. The machine learning technology utilized is deep multilayer networks (Deep Learning), and new models will continue to be produced, as relevant data is made available and specific health needs of astronaut crews are identified. The interfacing aspects of the system include a GUI for running the different models, and retrieving and storing data, as well as support for integration with an augmented reality (AR) system deployed at JSC by Tietronix Software Inc. (HoloLens). The AR system provides guidance for the placement of an ultrasound transducer that captures images to be sent to the MedICS system for diagnosis. The image captured and the associated diagnosis appear in the technician’s AR visual display.

Colombano, Silvano↗

Collaboration in Complex Medical Systems

Improving our understanding of collaborative work in complex environments has the potential for developing effective supporting technologies, personnel training paradigms, and design principles for multi-crew workplaces. USing a sophisticated audio-video-data acquisition system and a corresponding analysis system, the researchers at University of Maryland have been able to study in detail team performance during real trauma patient resuscitation. The first study reported here was on coordination mechanisms and on characteristics of coordination breakdowns. One of the key findings was that implicit communications were an important coordination mechanism (e.g. through the use of shared workspace and event space). The second study was on the sources of uncertainty during resuscitation. Although incoming trauma patients' status is inherently uncertain, the findings suggest that much of the uncertainty felt by care providers was related to communication and coordination. These two studies demonstrate the value of and need for creating a real-life laboratory for studying team performance with the use of comprehensive and integrated data acquisition and analysis tools.

Xiao, Yan↗

Microarthroscopy System With Image Processing Technology Developed for Minimally Invasive Surgery

In a joint effort, NASA, Micro Medical Devices, and the Cleveland Clinic have developed a microarthroscopy system with digital image processing. This system consists of a disposable endoscope the size of a needle that is aimed at expanding the use of minimally invasive surgery on the knee, ankle, and other small joints. This device not only allows surgeons to make smaller incisions (by improving the clarity and brightness of images), but it gives them a better view of the injured area to make more accurate diagnoses. Because of its small size, the endoscope helps reduce physical trauma and speeds patient recovery. The faster recovery rate also makes the system cost effective for patients. The digital image processing software used with the device was originally developed by the NASA Glenn Research Center to conduct computer simulations of satellite positioning in space. It was later modified to reflect lessons learned in enhancing photographic images in support of the Center's microgravity program. Glenn's Photovoltaic Branch and Graphics and Visualization Lab (G-VIS) computer programmers and software developers enhanced and speed up graphic imaging for this application. Mary Vickerman at Glenn developed algorithms that enabled Micro Medical Devices to eliminate interference and improve the images.

Steele, Gynelle C.↗

Hemodynamic and thermal responses to head and neck cooling in men and women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

NASA Center ARC↗

Spinoff 2013

Topics covered include: Innovative Software Tools Measure Behavioral Alertness; Miniaturized, Portable Sensors Monitor Metabolic Health; Patient Simulators Train Emergency Caregivers; Solar Refrigerators Store Life-Saving Vaccines; Monitors Enable Medication Management in Patients' Homes; Handheld Diagnostic Device Delivers Quick Medical Readings; Experiments Result in Safer, Spin-Resistant Aircraft; Interfaces Visualize Data for Airline Safety, Efficiency; Data Mining Tools Make Flights Safer, More Efficient; NASA Standards Inform Comfortable Car Seats; Heat Shield Paves the Way for Commercial Space; Air Systems Provide Life Support to Miners; Coatings Preserve Metal, Stone, Tile, and Concrete; Robots Spur Software That Lends a Hand; Cloud-Based Data Sharing Connects Emergency Managers; Catalytic Converters Maintain Air Quality in Mines; NASA-Enhanced Water Bottles Filter Water on the Go; Brainwave Monitoring Software Improves Distracted Minds; Thermal Materials Protect Priceless, Personal Keepsakes; Home Air Purifiers Eradicate Harmful Pathogens; Thermal Materials Drive Professional Apparel Line; Radiant Barriers Save Energy in Buildings; Open Source Initiative Powers Real-Time Data Streams; Shuttle Engine Designs Revolutionize Solar Power; Procedure-Authoring Tool Improves Safety on Oil Rigs; Satellite Data Aid Monitoring of Nation's Forests; Mars Technologies Spawn Durable Wind Turbines; Programs Visualize Earth and Space for Interactive Education; Processor Units Reduce Satellite Construction Costs; Software Accelerates Computing Time for Complex Math; Simulation Tools Prevent Signal Interference on Spacecraft; Software Simplifies the Sharing of Numerical Models; Virtual Machine Language Controls Remote Devices; Micro-Accelerometers Monitor Equipment Health; Reactors Save Energy, Costs for Hydrogen Production; Cameras Monitor Spacecraft Integrity to Prevent Failures; Testing Devices Garner Data on Insulation Performance; Smart Sensors Gather Information for Machine Diagnostics; Oxygen Sensors Monitor Bioreactors and Ensure Health and Safety; Vision Algorithms Catch Defects in Screen Displays; and Deformable Mirrors Capture Exoplanet Data, Reflect Lasers.

Source record↗

The Integrated Medical Model - Optimizing In-flight Space Medical Systems to Reduce Crew Health Risk and Mission Impacts

The Integrated Medical Model (IMM) is a decision support tool used by medical system planners and designers as they prepare for exploration planning activities of the Constellation program (CxP). IMM provides an evidence-based approach to help optimize the allocation of in-flight medical resources for a specified level of risk within spacecraft operational constraints. Eighty medical conditions and associated resources are represented in IMM. Nine conditions are due to Space Adaptation Syndrome. The IMM helps answer fundamental medical mission planning questions such as What medical conditions can be expected? What type and quantity of medical resources are most likely to be used?", and "What is the probability of crew death or evacuation due to medical events?" For a specified mission and crew profile, the IMM effectively characterizes the sequence of events that could potentially occur should a medical condition happen. The mathematical relationships among mission and crew attributes, medical conditions and incidence data, in-flight medical resources, potential clinical and crew health end states are established to generate end state probabilities. A Monte Carlo computational method is used to determine the probable outcomes and requires up to 25,000 mission trials to reach convergence. For each mission trial, the pharmaceuticals and supplies required to diagnose and treat prevalent medical conditions are tracked and decremented. The uncertainty of patient response to treatment is bounded via a best-case, worst-case, untreated case algorithm. A Crew Health Index (CHI) metric, developed to account for functional impairment due to a medical condition, provides a quantified measure of risk and enables risk comparisons across mission scenarios. The use of historical in-flight medical data, terrestrial surrogate data as appropriate, and space medicine subject matter expertise has enabled the development of a probabilistic, stochastic decision support tool capable of optimizing in-flight medical systems based on crew and mission parameters. This presentation will illustrate how to apply quantitative risk assessment methods to optimize the mass and volume of space-based medical systems for a space flight mission given the level of crew health and mission risk.

Kerstman, Eric↗

Effects of vestibular loss on head stabilization in response to head and body perturbations

Control of head position during postural responses is important to facilitate both the interpretation of vestibular signals and the stabilization of gaze. In these experiments, we compared head stabilization for two different postural tasks: 1) in response to perturbations at the head, and 2) in response to perturbations induced at the support surface, which perturb both body and head position. To determine whether normal vestibular function is necessary for head stabilization in these two tasks, responses to forward and backward mechanical perturbations of the head and body were compared for 13 normal subjects and 4 patients with profound bilateral vestibular loss (two with vestibular loss in adulthood and two in infancy). Normal subjects showed little neck muscle activity for body perturbations, but large, early activations in both neck extensors and flexors for head perturbations. In contrast, vestibular patients showed excessive neck muscle activation for body perturbations and reduced or absent neck muscle activity for head perturbations. Patients with vestibular loss in adulthood also showed increased head acceleration in response to both head and body perturbations, but patients with vestibular loss in infancy showed more normal head accelerations. For body perturbations, the differences in head acceleration between patients and normals were greater for later head acceleration peaks, indicating poor head control during the execution of the postural response. Trunk angle changes were also higher in the patients for forward body perturbations, indicating that poorer control of trunk position could have contributed to their poorer head stabilization. These results indicate that the vestibular system plays an important role in head and trunk stabilization for both head and body perturbations. However, the more normal head accelerations of the patients with infant vestibular loss also indicate that other mechanisms, possibly involving neck reflexes, can at least partially substitute for the vestibular system to provide head and trunk stabilization.

NASA Discipline Neuroscience↗

Linking Asthma Exacerbation and Air Pollution Data: A Step Toward Public Health and Environmental Data Integration

Studies have shown that reducing exposure to triggers such as air pollutants can reduce symptoms and the need for medication in asthma patients. However, systems that track asthma are generally not integrated with those that track environmental hazards related to asthma. Tlvs lack of integration hinders public health awareness and responsiveness to these environmental triggers. The current study is a collaboration between health and environmental professionals to utilize NASA-derived environmental data to develop a decision support system (DSS) for asthma prediction, surveillance, and intervention. The investigators link asthma morbidity data from the University of Mississippi Medical Center (UMMC) and Mississippi Department of Health (MDH) with air quality data from the Mississippi Department of Environmental Quality (MDEQ) and remote sensing data from NASA. Daily ambient environmental hazard data for PM2.5 and ozone are obtained from the MDEQ air quality monitoring locations and are combined with remotely sensed data from NASA to develop a state-wide spatial and time series profile of environmental air quality. These data are then used to study the correlation of these measures of air quality variation with the asthma exacerbation incidence throughout the state over time. The goal is to utilize these readily available measures to allow real-time risk assessment for asthma exacerbations. GeoMedStat, a DSS previously developed for biosurveillance, will integrate these measures to monitor, analyze and report the real-time risk assessment for asthma exacerbation throughout the state.

Faruque, Fazlay↗

Market Survey 2020: Commercial Clinical Decision Support Systems and Wellness Tools

For long-duration, deep space exploration missions, current methods for managing and supporting crew health and medical conditions will be unsuitable. Communication and data transmission lags will necessitate the use of a sophisticated clinical decision support system (CDSS) that will tailor diagnosis and treatment guidance that is context-sensitive for anticipated astronaut health, wellness, and medical conditions. A variety of clinical decision support (CDS) and wellness tools (WT) are currently available in the commercial market and a broad-brush survey of this market can provide an initial impression of the current state of the art which, in turn, can inform the roadmap of NASA deep space CDSS development and associated requirements. Such a survey was undertaken during the first six months of 2020 using directed convenience sampling to obtain information provided by vendors on their websites; both commercially available CDS and WT (such as those used to track and monitor nutrition, exercise, and sleep) were included. Areas assessed were item type (e.g., software/application, device); primary purpose of the item (e.g., diagnostic support, nutrition tracking); additional purposes (if any); reported features, capabilities, and functionality; setting of use (e.g., inpatient, outpatient); intended user (e.g., clinician, patient); location and sources of data/information used or produced by the item; integration with patient electronic health record (EHR); compliance with interoperability ontologies and standards (e.g., Health Level 7 [HL7], Systematized Nomenclature of Medicine – Clinical Terminology [SNOMED-CT]); and whether the item is knowledge-based (derived from research findings) or non-knowledge-based (derived through artificial intelligence, machine learning, advanced probability and statistics), among others. Ninety-seven (97) vendor websites describing 196 CDS and 73 WT (269 total) were reviewed and coded. The primary purpose of the majority of CDS reviewed is diagnosis or diagnosis/treatment/drug decision support—targeted for clinician use— and the primary purpose of the majority of WT reviewed is the monitoring of different health metrics, most often through the use of a biosensor device (e.g., blood pressure)—targeted for patient use. Very few CDS or WT appear to comply with major international interoperability standards or can be integrated with a patient’s EHR data. None consider contextual factors, such as conditions of the physical environment (e.g., CO2 levels). The majority of CDS and WT reviewed are non-knowledge, cloud- or web-based applications or software. Forty-three (43) major findings were identified and the implications those findings have for NASA will be discussed. Example major findings include: CDS-WT capabilities range from diagnosis to treatment applications, CDS-WT may be wearable or non-wearable and are technologically advanced and only a few CDS-WT tools referenced compliance to ensure interoperability, among other findings. Recommendations will also be offered that will help to address ExMC Gap, Medical-701: Enhance medical capabilities within an exploration medical system.

market survey↗

Current concepts in the pathophysiology, evaluation, and diagnosis of compartment syndrome

This article reviews present knowledge of the pathophysiology and diagnosis of acute compartment syndromes. Recent results using compression of legs in normal volunteers provide objective data concerning local pressure thresholds for neuromuscular dysfunction in the anterior compartment. Results with this model indicate that a progression of neuromuscular deficits occurs when IMP increases to within 35 to 40 mm Hg of diastolic blood pressure. These findings provide useful information on the diagnosis and compression thresholds for acute compartment syndromes. Time factors are also important, however, and usually are incompletely known in most cases of acute compartment syndrome. Although the slit catheter is a very good technique for monitoring IMP during rest, these catheters and their associated extracorporeal transducer systems are not ideal. Recently developed miniature transducer-tipped catheters and, perhaps, future development of noninvasive techniques may provide accurate recordings of IMP in patients with acute compartment syndromes.

NASA Discipline Cardiopulmonary↗

Left ventricular diastolic filling with an implantable ventricular assist device: beat to beat variability with overall improvement

OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.

Non-NASA Center↗

Exploration Atmosphere Demonstration of A Multi-Functional Integrated Medical Device (Tempus Pro)

INTRODUCTION The Exploration Medical Capability (ExMC) element within the Human Research Program and the Exploration Medical Integrated Product Team (XMIPT) within the Mars Campaign Office seek to advance medical system design and risk-informed decision-making for exploration missions. This includes assessment of candidate devices and their compatibility within a variety of increasingly Earth-independent medical scenarios. The Tempus Pro (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf (COTS), multi-functional integrated medical device capable of vital signs monitoring, with built-in procedure support (iAssist), patient record and telemedicine communication features, and medical imaging (e.g., camera, laryngoscope, ultrasound) that meets multiple exploration medical capability needs. One of several hypobaric atmospheres being considered for exploration vehicles is 8.2 psi with 34% oxygen. To assess the useability of the Tempus Pro in such environments by individuals without formal medical training, the unit was tested in May and June of 2023 at the Johnson Space Center 20-Foot Exploration Atmosphere Chamber in conjunction with the Exploration Atmospheres-2 (EA-2) study. TECHNOLOGY DEMONSTRATION Eight subjects in the EA-2 study were assigned roles as the caregiver or patient – or both in the case of a self-exam – and caregivers were asked to place sensors for 3-Lead ECG, non-invasive blood pressure (NIBP), pulse oximetry (SpO2), and temperature using Tempus Pro’s iAssist. Depending on the procedure, additional tasks included an oropharyngeal exam of the throat with the laryngoscope and capturing ultrasound images of a cardiac subxiphoid view or of the user’s choice from a pre-specified list. Scenarios ranged from remote-guided to fully autonomous operations and surveyed the effectiveness of support, amount of support desired, and importance of support by type (e.g., written crew procedures, iAssist and device guidance, remote console guidance, etc.). Feedback from the subjects and the support personnel was also gathered to inform future designs for training and support and to determine what operations are plausible given different levels of each. An unweighted NASA task load index (TLX) was used to profile the demands of using the device, however the sample size does not support statistics. The research was exploratory in nature and qualitative information was the main goal. Calibration checks on the Tempus Pro were conducted before and after chamber testing to ensure the device was in useable condition. RESULTS All subjects performed their tasks successfully and found the Tempus Pro easy to use with the support provided. The calibration checks outside the chamber showed that the Tempus Pro remained unchanged and measurements inside the chamber were within normal values. Caregivers taking the NASA TLX reported mean scores ≤ 41/100 showing the tasks to be undemanding and less demanding with repeated use (~20/100). Novice users were able to easily connect sensors and take vital signs with the guidance from Tempus Pro’s iAssist feature. For more complex tasks, such as the oropharyngeal exam and ultrasound image acquisition, guidance beyond iAssist was needed, primarily from a supporting physician. Feedback on the importance of support types varied by person and scenario but greater than 50% of the support used by each was non-native to the device. Overall opinions were positive, but the ultrasound users expressed a lack of confidence in their results and 3 out of 4 desired more time, training, or support. Subjects found the sensors to be comfortable and comparable to prior experiences with such devices, except for the blood pressure cuff, which squeezed too tightly for uncomfortably long periods. Many observations provoked discussion, especially regarding ultrasound, that will aide decisions about future demonstrations.

R. S. Miller↗