Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pattern reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Status of the MicroBooNE Inclusive Single Photon Selection Using Wire-Cell Reconstruction

MicroBooNE is a Liquid Argon Time Project Chamber (LArTPC) detector whose primary design goal is to understand the “low-energy-excess” anomaly seen by MiniBooNE. MicroBooNE’s currently published results see no excess consistent with the MiniBooNE observation, therefore creating a need for searches in more channels. This note summarizes MicroBooNE’s inclusive single photon selection using Wire-Cell reconstruction and pattern recognition, which will be used to search for a low-energy-excess (LEE) anomaly in the inclusive single photon channel. The selection is similar to the Wire-Cell inclusive electron neutrino selection, but with a different signal definition and some modifications and additions to the pattern recognition tools. A selection with 15.2% efficiency and 18.5% purity is achieved for simulated Standard Model single photon events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Update on MicroBooNE’s Inclusive Single Photon Low Energy Excess Search

The MicroBooNE detector is a Liquid Argon Time Project Chamber (LArTPC) detector whose primary design goal is to understand the "low-energy-excess" anomaly seen by MiniBooNE. MicroBooNE's currently published results see no excess consistent with the MiniBooNE observation, emphasizing a need for improved searches in more channels. This note summarizes MicroBooNE's inclusive single photon selection using Wire-Cell reconstruction and pattern recognition, which is used to search for a low-energy-excess (LEE) anomaly in the inclusive single photon channel. The selection is similar to the Wire-Cell inclusive electron neutrino selection, but with a different signal definition and some modifications and additions to the pattern recognition tools. A selection with 7.0% efficiency and 40.2% purity is achieved for our targeted single photon signal simulated events.

43 PARTICLE ACCELERATORS↗

Status of the MicroBooNE inclusive single photon selection using Wire-Cell reconstruction

MicroBooNE is a Liquid Argon Time Project Chamber (LArTPC) detector whose primary design goal is to understand the “low-energy-excess” anomaly seen by MiniBooNE. MicroBooNE’s currently published results see no excess consistent with the MiniBooNE observation, therefore creating a need for searches in more channels. This note summarizes MicroBooNE’s inclusive single photon selection using Wire-Cell reconstruction and pattern recognition, which will be used to search for a low-energy-excess (LEE) anomaly in the inclusive single photon channel. The selection is similar to the Wire-Cell inclusive electron neutrino selection, but with a different signal definition and some modifications and additions to the pattern recognition tools. A selection with 15.2% efficiency and 18.5% purity is achieved for simulated Standard Model single photon events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient High Order Central Schemes for Multi-Dimensional Hamilton-Jacobi Equations: Talk Slides

This viewgraph presentation presents information on the attempt to produce high-order, efficient, central methods that scale well to high dimension. The central philosophy is that the equations should evolve to the point where the data is smooth. This is accomplished by a cyclic pattern of reconstruction, evolution, and re-projection. One dimensional and two dimensional representational methods are detailed, as well.

Bryson, Steve↗

3-D Reconstruction of Macular Type II Cell Innervation Patterns in Space-Flight and Control Rats

A semiautomated method for reconstructing objects from serial thin sections has been developed in the Biocomputation Center. The method is being used to completely, for the first time, type II hair cells and their innervations. The purposes are to learn more about the fundamental circuitry of the macula on Earth and to determine whether changes in connectivities occur under space flight conditions. Data captured directly from a transmission electron microscope via a video camera are sent to a graphics workstation. There, the digitized micrographs are mosaicked into sections and contours are traced, registered and displayed by semiautomated methods. Current reconstructions are of type II cells from the medial part of rat maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that typical type II cells receive processes from tip to six nearby calyces or afferents. Nearly all processes are elongated and have bouton-like enlargements; some have numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approximately 1/3 of the processes innervale 2 or 3 type II cells or a neighboring cluster. From 2% to 6% of the cells resemble type I cells morphologically but have demi-calyces. Thus far, increments in synaptic number in type II cells of flight rats are prominent along processes that supply two hair cells. It is clear that reconstruction methods provide insights into details of macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields through feed back-feed forward connections, and for dynamic alterations in receptive field range and activity during preprocessing of linear acceleratory information by the maculas. The reconstruction method we have developed will find further applications in the study of the details of neuronal architecture of more complex systems, to seek out shared organizational properties or neuronal networks and to understand better localization of synaptic changes in altered environments.

Ross, Muriel Dorothy↗

Characterization of On-Orbit GPS Transmit Antenna Patterns for Space Users

The GPS Antenna Characterization Experiment (GPS ACE) has made extensive observations of GPS L1 signals received at geosynchronous (GEO) altitude, with the objective of developing comprehensive models of the signal levels and signal performance in the GPS transmit antenna side lobes. The experiment was originally motivated by the fact that data on the characteristics and performance of the GPS signals available in GEO and other high Earth orbits was limited. The lack of knowledge of the power and accuracy of the side lobe signals on-orbit added risk to missions seeking to employ the side lobes to meet navigation requirements or improve performance. The GPS ACE Project lled that knowledge gap through a collaboration between The Aerospace Corporation and NASA Goddard Space Fight Center to collect and analyze observations from GPS side lobe transmissions to a satellite at GEO using a highly-sensitive GPS receiver installed at the ground station. The GPS ACE architecture has been in place collecting observations of the GPS constellation with extreme sensitivity for several years. This sensitivity combined with around-the-clock, all-in-view processing enabled full azimuthal coverage of the GPS transmit gain patterns over time to angles beyond 90 degrees o -boresight. Results discussed in this paper include the reconstructed transmit gain patterns, with comparisons to available pre-fight gain measurements from the GPS vehicle contractors. For GPS blocks with extensive ground measurements, the GPS ACE results show remarkable agreement with ground based measurements. For blocks without extensive ground measurements, the GPS ACE results provide the only existing assessments of the full transmit gain patterns. The paper also includes results of pseudorange deviation analysis to assess systematic errors associated with GPS side lobe signals.

Donaldson, Jennifer E.↗

Characterization of On-Orbit GPS Transmit Antenna Patterns for Space Users

The GPS Antenna Characterization Experiment (GPS ACE) has made extensive observations of GPS L1 signals received at geosynchronous (GEO) altitude, with the objective of developing comprehensive models of the signal levels and signal performance in the GPS transmit antenna side lobes. The experiment was originally motivated by the fact that data on the characteristics and performance of the GPS signals available in GEO and other high Earth orbits was limited. The lack of knowledge of the power and accuracy of the side lobe signals on-orbit added risk to missions seeking to employ the side lobes to meet navigation requirements or improve performance. The GPS ACE Project lled that knowledge gap through a collaboration between The Aerospace Corporation and NASA Goddard Space Fight Center to collect and analyze observations from GPS side lobe transmissions to a satellite at GEO using a highly-sensitive GPS receiver installed at the ground station. The GPS ACE architecture has been in place collecting observations of the GPS constellation with extreme sensitivity for several years. This sensitivity combined with around-the-clock, all-in-view processing enabled full azimuthal coverage of the GPS transmit gain patterns over time to angles beyond 90 degrees o -boresight. Results discussed in this paper include the reconstructed transmit gain patterns, with comparisons to available pre-fight gain measurements from the GPS vehicle contractors. For GPS blocks with extensive ground measurements, the GPS ACE results show remarkable agreement with ground based measurements. For blocks without extensive ground measurements, the GPS ACE results provide the only existing assessments of the full transmit gain patterns. The paper also includes results of pseudorange deviation analysis to assess systematic errors associated with GPS side lobe signals.

Jennifer E Donaldson↗

Characterization of On-Orbit GPS Transmit Antenna Patterns for Space Users

The GPS Antenna Characterization Experiment (GPS ACE) has made extensive observations of GPS L1 signals received at geosynchronous (GEO) altitude, with the objective of developing comprehensive models of the signal levels and signal performance in the GPS transmit antenna side lobes. The experiment was originally motivated by the fact that data on the characteristics and performance of the GPS signals available in GEO and other high Earth orbits was limited. The lack of knowledge of the power and accuracy of the side lobe signals on-orbit added risk to missions seeking to employ the side lobes to meet navigation requirements or improve performance. The GPS ACE Project lled that knowledge gap through a collaboration between The Aerospace Corporation and NASA Goddard Space Fight Center to collect and analyze observations from GPS side lobe transmissions to a satellite at GEO using a highly-sensitive GPS receiver installed at the ground station. The GPS ACE architecture has been in place collecting observations of the GPS constellation with extreme sensitivity for several years. This sensitivity combined with around-the-clock, all-in-view processing enabled full azimuthal coverage of the GPS transmit gain patterns over time to angles beyond 90 degrees off-boresight. Results discussed in this paper include the reconstructed transmit gain patterns, with comparisons to available pre-fight gain measurements from the GPS vehicle contractors. For GPS blocks with extensive ground measurements, the GPS ACE results show remarkable agreement with ground based measurements. For blocks without extensive ground measurements, the GPS ACE results provide the only existing assessments of the full transmit gain patterns. The paper also includes results of pseudorange deviation analysis to assess systematic errors associated with GPS side lobe signals.

space↗

Novel light field imaging device with enhanced light collection for cold atom clouds

We present a light field imaging system that captures multiple views of an object with a single shot. The system is designed to maximize the total light collection by accepting a larger solid angle of light than a conventional lens with equivalent depth of field. This is achieved by populating a plane of virtual objects using mirrors and fully utilizing the available field of view and depth of field. Simulation results demonstrate that this design is capable of single-shot tomography of objects of size $\mathcal{O}$(1 mm 3 ), reconstructing the 3-dimensional (3D) distribution and features not accessible from any single view angle in isolation. In particular, for atom clouds used in atom interferometry experiments, the system can reconstruct 3D fringe patterns with size $\mathcal{O}$(100 μm). We also demonstrate this system with a 3D-printed prototype. The prototype is used to take images of $\mathcal{O}$(1 mm 3 ) sized objects, and 3D reconstruction algorithms running on a single-shot image successfully reconstruct $\mathcal{O}$(100 μm) internal features. The prototype also shows that the system can be built with 3D printing technology and hence can be deployed quickly and cost-effectively in experiments with needs for enhanced light collection or 3D reconstruction. Imaging of cold atom clouds in atom interferometry is a key application of this new type of imaging device where enhanced light collection, high depth of field, and 3D tomographic reconstruction can provide new handles to characterize the atom clouds.

47 OTHER INSTRUMENTATION↗

A Climate and History Case Study of 18th- and 19th-Century Multidecadal Droughts in East Africa Using a new Tree-Ring Drought Atlas

Historians and paleoclimatologists have both identified the decades spanning the late-18th and early-19th centuries in many East African regions as a period of prolonged and severe drought. A challenge that emerges from both the historical evidence and the paleolimnological data that have been primarily used to characterize this drought period, however, concerns the dating of events and the characterization of their spatial character; both oral traditions and lake-core proxies cannot typically offer hydroclimate estimates with seasonal or annual resolution, nor can they provide gridded reconstructions on the order of 1° latitude and longitude. The new East African Drought Atlas (EADA) incorporates far-field dendroclimatic records and several local East African tree-ring chronologies to provide estimates of the self-calibrating Palmer Drought Severity Index (scPDSI) on a 0.5° latitude-longitude grid. We present the Point-by-Point Regression technique that was used to create the EADA, the rationale for the employed input data network, and the calibration and validation skill of the derived hydroclimatic field reconstruction. We use the EADA to characterize the timing of two decadal-scale droughts, centered over the Uganda and Kenya regions, which occurred in the late 18th century and early in the 19th century and were separated by a shorter, but pronounced wet period. We characterize the spatial patterns of the associated events and the dynamical causes that that the patterns imply. The reconstructed droughts are also compared to historical and paleolimnological data to evaluate the robustness of the reconstruction and the degree of agreement across the different sources of information.

Droughts↗

A Climate and History Case Study of 18th- and 19th-Century Multidecadal Droughts in East Africa Using a new Tree-Ring Drought Atlas

Historians and paleoclimatologists have both identified the decades spanning the late-18th and early-19th centuries in many East African regions as a period of prolonged and severe drought. A challenge that emerges from both the historical evidence and the paleolimnological data that have been primarily used to characterize this drought period, however, concerns the dating of events and the characterization of their spatial character; both oral traditions and lake-core proxies cannot typically offer hydroclimate estimates with seasonal or annual resolution, nor can they provide gridded reconstructions on the order of 1° latitude and longitude. The new East African Drought Atlas (EADA) incorporates far-field dendroclimatic records and several local East African tree-ring chronologies to provide estimates of the self-calibrating Palmer Drought Severity Index (scPDSI) on a 0.5° latitude-longitude grid. We present the Point-by-Point Regression technique that was used to create the EADA, the rationale for the employed input data network, and the calibration and validation skill of the derived hydroclimatic field reconstruction. We use the EADA to characterize the timing of two decadal-scale droughts, centered over the Uganda and Kenya regions, which occurred in the late 18th century and early in the 19th century and were separated by a shorter, but pronounced wet period. We characterize the spatial patterns of the associated events and the dynamical causes that that the patterns imply. The reconstructed droughts are also compared to historical and paleolimnological data to evaluate the robustness of the reconstruction and the degree of agreement across the different sources of information.

Droughts↗

Case study of sample spacing in planar near-field measurement of high gain antennas

Far field antenna patterns can be reconstructed from planar near field measurements acquired at a sample spacing of lambda/2 or less. For electrically large antennas, sampling at the Nyquist rate may result in errors due to system electronic drift over long acquisition times. The computer capacity may limit the largest size of the near field data set. The requirement to sample at the Nyquist rate is relaxed for high gain antennas which concentrate most of the radiated energy into a small angular region of the far field. The criteria for sample spacing at greater than lambda/e through the use of a priori information of the antenna radiation characteristics are presented. Far field patterns of a 30 GHz dual offset reflector system with a 2.7 m parabolic main reflector are computed from near field data obtained at sample spacings ranging from 0.1 lambda to 10 lambda. The effects of sampling interval and spectrum cutoff on the far field patterns are discussed.

Acosta, R. J.↗

A biomimetic eye with a hemispherical perovskite nanowire array retina

Human eyes possess exceptional image-sensing characteristics such as an extremely wide field of view, high resolution and sensitivity with low aberration1. Biomimetic eyes with such characteristics are highly desirable, especially in robotics and visual prostheses. However, the spherical shape and the retina of the biological eye pose an enormous fabrication challenge for biomimetic devices2,3. In this paper, we present an electrochemical eye with a hemispherical retina made of a high-density array of nanowires mimicking the photoreceptors on a human retina. The device design has a high degree of structural similarity to a human eye with the potential to achieve high imaging resolution when individual nanowires are electrically addressed. Additionally, we demonstrate the image-sensing function of our biomimetic device by reconstructing the optical patterns projected onto the device. This work may lead to biomimetic photosensing devices that could find use in a wide spectrum of technological applications.

42 ENGINEERING↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

Single-frame far-field diffractive imaging with randomized illumination

Contains a transmission ptychography dataset collected from a chrome on glass Siemens star under optical illumination. The probe is generated by a randomized zone plate under illumination from a spatially filtered green laser. A single diffraction pattern was removed from the dataset and reported in a separate cxi file. In addition, a single exposure collected after manually defocusing the probe is reported. The ptychography dataset is used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

Ptychography, Randomized Probe Imaging↗

Single-frame far-field diffractive imaging with randomized illumination

Contains two transmission ptychography datasets, one collected from a Siemens star, and the second from an Fe/Gd multilayer. Both samples are under illumination from the same randomized zone plate. Each dataset has a single diffraction pattern removed, and these patterns are reported in a separate cxi file. Either ptychography dataset can be used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

BESSY II↗

Internal 2-D Surface Temperature Measurements for Large Complex Geometries

For 2D-temperature monitoring applications, a variant of EIT (Electrical Impedance Tomography) is evaluated computationally in this work. Literature examples of poor sensor performance in the center of the 2D domains away from the side electrodes motivated this study which seeks to overcome some of the previously noted shortcomings. In particular, the use of ‘sensing skins’ with novel tailored baseline conductivities were examined using the EIDORS package for EIT. It was found that the best approach for detecting a hot spot depends on several factors such as the current injection (stimulation) patterns, the measurement patterns, and the reconstruction algorithms. For a well-performing combination of these factors, tailored baseline conductivities were assessed and compared to the baseline uniform conductivity. It was discovered that for some EIT applications, a tailored distribution needs to be smooth and that sudden changes in the conductivity gradients should be avoided. Still, the benefits in terms of improved EIT performance were small for conditions for which the EIT measurements had been ‘optimized’ for the uniform baseline case. Within the limited scope of this study, only two specific cases showed benefits from tailored distributions. For one case, a smooth tailored distribution with increased baseline conductivity in the center provided a better separation of two centrally located hot spots. For another case, a smooth tailored distribution with reduced conductivity in the center provided better estimates of the magnitudes of two hot spots near the center of the sensing skin.

47 OTHER INSTRUMENTATION↗

Particle field holography data reduction by Fourier transform analysis

The size distribution of a particle field hologram is obtained with a Fourier transformation of the Fraunhofer diffraction pattern of the reconstructed hologram. Off-axis absorption holograms of particle fields with known characteristics were obtained and analyzed with a commercially available instrument. The mean particle size of the reconstructed hologram was measured with an error of + or - 5 percent, while the distribution broadening was estimated within + or - 15 percent. Small sections of a pulsed laser hologram of a synthetic fuel spray were analyzed with this method thus yielding a spatially resolved size distribution. The method yields fast and accurate automated analysis of particle field holograms.

Hess, Cecil F.↗