Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance: Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Wind Turbinie Generator System Power Performance Test Report for the Mariah Windspire 1-kW Wind Turbine

This report summarizes the results of a power performance test that NREL conducted on the Mariah Windspire 1-kW wind turbine. During this test, two configurations were tested on the same turbine. In the first configuration, the turbine inverter was optimized for power production. In the second configuration, the turbine inverter was set for normal power production. In both configurations, the inverter experienced failures and the tests were not finished.

1-KW WIND TURBINE↗

Backup Power Performance of Solar-plus-Storage Systems during Routine Power Interruptions: A Case Study Application of Berkeley Lab’s PRESTO Model

This technical brief estimates the expected performance of a solar photovoltaic and energy storage system (PVESS) for providing backup power during short-duration power interruption events, accounting for the unpredictable nature of those events. The analysis relies on the Power Reliability Event Simulation TOol (PRESTO), a publicly available model developed by Berkeley Lab to simulate the occurrence of short-duration power interruption events at the county-level. A separate storage dispatch model is then used to simulate PVESS operation and backup performance for each of the large number of interruption events produced by PRESTO. In performing this simulation, the analysis accounts for how the customer operates its battery on a day-to-day basis—in this case, we assume the battery is cycled each day in response to time-of-use rates—and how that, in turn, impacts the battery’s state of charge at the beginning of each interruption event. The analysis presented here is intended to demonstrate an application of the PRESTO model as well as to illustrate some of the key determinants of PVESS backup power performance during short-duration power interruption events. The analysis focuses initially on a typical single-family home in Maricopa County, Arizona, and includes a limited set of scenarios related to system sizing, backup power configuration, and whether the customer charges its battery storage system from the grid during normal operating conditions. The analysis also presents comparative results for two other counties, in Massachusetts (Middlesex) and California (Los Angeles), illustrating how regional differences in climate, interruption patterns, and retail rate structures can affect PVESS performance as a backup power source. In the conclusions, we highlight a number of other important considerations for evaluating PVESS backup power capabilities.

14 SOLAR ENERGY↗

In-Situ Measurement of Crystalline Silicon Modules Undergoing Potential-Induced Degradation in Damp Heat Stress Testing for Estimation of Low-Light Power Performance

The extent of potential-induced degradation of crystalline silicon modules in an environmental chamber is estimated using in-situ dark I-V measurements and applying superposition analysis. The dark I-V curves are shown to correctly give the module power performance at 200, 600 and 1,000 W/m 2 irradiance conditions, as verified with a solar simulator. The onset of degradation measured in low light in relation to that under one sun irradiance can be clearly seen in the module design examined; the time to 5% relative degradation measured in low light (200 W/m 2 ) was 28% less than that of full sun (1,000 W/m 2 irradiance). The power of modules undergoing potential-induced degradation can therefore be characterized in the chamber, facilitating statistical analyses and lifetime forecasting.

14 SOLAR ENERGY↗

MIR Solar Array Return Experiment: Power Performance Measurements and Molecular Contamination Analysis Results

A solar array segment was recently removed from the Mir core module and returned for ground-based analysis. The segment, which is similar to the ones the Russians have provided for the FGB and Service Modules, was microscopically examined and disassembled by US and Russian science teams. Laboratory analyses have shown the segment to he heavily contaminated by an organic silicone coating, which was converted to an organic silicate film by reactions with atomic oxygen within the. orbital flight environment. The source of the contaminant was a silicone polymer used by the Russians as an adhesive and bonding agent during segment construction. During its life cycle, the array experienced a reduction in power performance from approx. 12%, when it was new and first deployed, to approx. 5%, when it was taken out of service. However, current-voltage measurements of three contaminated cells and three pristine, Russian standard cells have shown that very little degradation in solar array performance was due to the silicate contaminants on the solar cell surfaces. The primary sources of performance degradation is attributed to "thermal hot-spotting" or electrical arcing; orbital debris and micrometeoroid impacts; and possibly to the degradation of the solar cells and interconnects caused by radiation damage from high energy protons and electrons.

Visentine, James↗

The Power Curve Working Group's Assessment of Wind Turbine Power Performance Prediction Methods

A wind turbine power curve is often only strictly valid for a subset of all atmospheric conditions (i.e., the inner range), while wind turbines also operate in other scenarios (i.e., the outer range). Hence, modeling the power output in real-world conditions is a fundamental challenge. For example, the power deviation matrix (PDM) in Figure 1 displays an overprediction of power production using a reference power curve when wind speed (WS) and turbulence intensity (TI) are both low. Many experts use the PDM approach to observe any systematic bias in power curves and correct this in energy yield models. The mission of the Power Curve Working Group (PCWG) is to bring together wind industry stakeholders to help identify, validate, and develop ways to improve modeling of wind turbine performance in all atmospheric conditions.

17 WIND ENERGY↗

Highly-Accessible Catalysts for Durable High-Power Performance (Final Technical Report)

Reduction of costly Pt usage in proton exchange membrane fuel cell (PEMFC) electrodes is one of the major challenges towards development and commercialization of fuel cell electric vehicles (FCEV). However, reducing the Pt loading results in increasing local mass transport fluxes, and eventual performance loss, especially at high power. In this project, a team of 4 universities, 2 companies, and a national lab came together to develop fuel cell catalysts and electrodes with high performance and durability. The were several key concepts addressed in this project. The first concept is to develop a carbon support that possess internal porosity which are believed to enhance kinetic activity of the catalysts, and yet the pore morphology allows for good reactant transport. The second concept is to improve the Pt-electrolyte interface in hope to reduce the local transport resistance. This was done by using new ionomers and ionic liquids. The last concept involves improving the catalyst stability by introducing Pt alloy catalyst with ordered intermetallic phase. The collaborative platform provided by DOE funding enabled development of a highly active and durable catalyst with performance that exceeds previous catalysts and meets the DOE targets for light duty vehicle application.

08 HYDROGEN↗

Program optimizations: The interplay between power, performance, and energy

Practical considerations for future supercomputer designs will impose limits on both instantaneous power consumption and total energy consumption. Working within these constraints while providing the maximum possible performance, application developers will need to optimize their code for speed alongside power and energy concerns. This paper analyzes the effectiveness of several code optimizations including loop fusion, data structure transformations, and global allocations. A per component measurement and analysis of different architectures is performed, enabling the examination of code optimizations on different compute subsystems. Using an explicit hydrodynamics proxy application from the U.S. Department of Energy, LULESH, we show how code optimizations impact different computational phases of the simulation. This provides insight for simulation developers into the best optimizations to use during particular simulation compute phases when optimizing code for future supercomputing platforms. Here, we examine and contrast both x86 and Blue Gene architectures with respect to these optimizations.

97 MATHEMATICS AND COMPUTING↗

High performance power handling in the absence of an H-mode edge in negative triangularity DIII-D plasmas

Abstract Experiments performed during strongly-shaped high-power diverted negative triangularity (NT) experiments in DIII-D achieved detached divertor conditions and a transient-free edge, showcasing the potential for application of NT to a core-edge integrated reactor-like scenario and providing the first characterization of the parametric dependencies for detachment onset. Detached divertor conditions will be required in future devices to mitigate divertor heat fluxes. Access to dissipative divertor conditions was investigated via an increase in upstream density. Detachment onset at the outer strike point was achieved with H-mode level confinement H 98 − y 2 ∼ 1 and reactor-relevant normalized pressures β N ∼ 2 . Confinement degradation was observed with deeper detachment, associated with the loss of an electron temperature pedestal. Differences in geometry, radial transport, impact of cross field drifts are discussed to explain differences in access to detachment in NT discharges. Higher normalized densities, with respect to equivalent discharges in positive triangularity, were necessary to achieve detachment, partially explained by the shorter parallel connection length to the targets. The effect of cross-field particle drifts ( E × B , B × ∇ B ) on access to detachment was demonstrated by the lower upstream density needed to access detachment with ion B × ∇ B drift directed outside of the active divertor (Greenwald fraction f Gw ∼ 0.9–1.0 vs f Gw ∼ 1.3). The upstream density at detachment onset was observed to increase linearly with plasma current with ion B × ∇ B drift into the divertor, consistent with the observed narrowing of the scrape-off layer heat flux width λ q . Edge fluid simulations capture separatrix densities needed to achieve detachment in NT plasma and their dependence on drift direction. The ability to reproduce detachment dynamics in NT plasma increases the confidence in future design studies for NT divertors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Power Performance of a 100-kW Class Nested Hall Thruster

Operations of a three-channel 100-kW class nested Hall thruster at total power levels from 5 to 102 kW and discharge currents from 16 to 247 A were successful. The thruster was operated in all seven available channel combinations at discharge voltages of 300, 400, and 500 V and at current densities that were 0.60 and 0.95 of the nominal value. Additional test points were also collected at 1.20 the nominal current density. The thruster was throttled through a total of forty-six unique operating conditions. At each condition, thruster performance was measured using a high-power thrust stand designed to measure up to 8 N of thrust. From these thrust measurements, specific impulse and efficiency were calculated. All seven channel combinations showed similar performance at a given discharge voltage and current density. The largest thrust recorded was 5.42 N at 99 kW, 400 V discharge voltage. Total efficiency values 0.54 to 0.67, and total specific impulse ranged from 1800 seconds to 2650 seconds. Discharge current oscillations were also measured. Generally these oscillations increased on the inner and middle channels during multi-channel mode but stayed roughly a constant fraction of the channel discharge current for the outer channel in both single- and multi-channel operation. We also found that the thrust of the three channels firing together was not significantly higher than the sum of each channel _ring individually, a result that differs from what was found previously for nested Hall thrusters.

Hall, Scott J.↗

High-Power Performance of a 100-kW Class Nested Hall Thruster

The performance of a three-channel, 100-kW class nested Hall thruster was evaluated on xenon propellant for total powers up to 102 kW at NASA Glenn Research Center. The thruster demonstrated stable operation in all seven available channel combinations at discharge voltages from 300 V to 500 V and three different current densities. The resulting test matrix contained forty-six unique conditions ranging from 5 to 102 kW total power and 16 to 247 A discharge current. At each operating condition, thruster performance was measured, and from these measurements specific impulse and efficiency were calculated. All seven channel combinations showed similar performance at a given discharge voltage and current density. The largest thrust recorded was 5.4 N ± 0.1 N at 99 kW, 400 V discharge voltage. Total efficiency and specific impulse ranged from 0.54 to 0.67 ± 0.03 and 1800 seconds to 2650 seconds ± 60 seconds, respectively. It was found that the thrust of the three channels firing together was not larger than the sum of each channel firing individually. Discharge current oscillations were also characterized with peak-to-peak and root-mean-square values and with power spectral density analysis. The implications of these results are discussed in the context of operation beyond 100 kW, as well as the general viability of NHT technology for future mission applications.

Hall, Scott J.↗

Low-Rank Coal Grinding Performance Versus Power Plant Performance

The intent of this project was to demonstrate that Alaskan low-rank coal, which is high in volatile content, need not be ground as fine as bituminous coal (typically low in volatile content) for optimum combustion in power plants. The grind or particle size distribution (PSD), which is quantified by percentage of pulverized coal passing 74 microns (200 mesh), affects the pulverizer throughput in power plants. The finer the grind, the lower the throughput. For a power plant to maintain combustion levels, throughput needs to be high. The problem of particle size is compounded for Alaskan coal since it has a low Hardgrove grindability index (HGI); that is, it is difficult to grind. If the thesis of this project is demonstrated, then Alaskan coal need not be ground to the industry standard, thereby alleviating somewhat the low HGI issue (and, hopefully, furthering the salability of Alaskan coal). This project studied the relationship between PSD and power plant efficiency, emissions, and mill power consumption for low-rank high-volatile-content Alaskan coal. The emissions studied were CO, CO{sub 2}, NO{sub x}, SO{sub 2}, and Hg (only two tests). The tested PSD range was 42 to 81 percent passing 76 microns. Within the tested range, there was very little correlation between PSD and power plant efficiency, CO, NO{sub x}, and SO{sub 2}. Hg emissions were very low and, therefore, did not allow comparison between grind sizes. Mill power consumption was lower for coarser grinds.

01 COAL, LIGNITE, AND PEAT↗

The Power-Performance Tradeoffs of the Intel Xeon Phi on HPC Applications

Accelerators are used in about 13% of the current Top500 List. Supercomputers leveraging accelerators grew by a factor of 2.2x in 2012 and are expected to completely dominate the Top500 by 2015. Though most of these deployments use NVIDIA GPGPU accelerators, Intel’s Xeon Phi architecture will likely grow in popularity in the coming years. Unfortunately, there are few studies analyzing the performance and energy efficiency of systems leveraging the Intel Xeon Phi. We extend our systemic measurement methodology to isolate system power by component including accelerators. We use this methodology to present a detailed study of the performance-energy tradeoffs of the Xeon Phi architecture.

Li, Bo↗

Codesign Challenges for Exascale Systems: Performance, Power and Reliability

The complexity of large-scale parallel systems necessitates the simultaneous optimization of multiple hardware and software components in order to achieve goals in performance, energy efficiency, and fault tolerance. Using tools such as performance modeling that enable exploration of design alternatives prior to implementation, we demonstrate the benefits of a co-design methodology for optimizing extreme-scale systems on the path to Exascale systems and workloads.

Kerbyson, Darren J.↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗