Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Data Analysis and Reporting System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bridging the Gap on Data and Analysis for Distribution System Planning: Information That Utilities Can Provide Regulators, State Energy Offices and Other Stakeholders

Electric utilities conduct planning annually to ensure their distribution system meets technical standards, policies, and regulations; addresses forecasted grid conditions; satisfies customer needs; and advances utility priorities. The plan identifies grid deficiencies, analyzes potential solutions, and prioritizes capital investments and other expenditures. About 20 U.S. states and jurisdictions require regulated utilities to file some type of distribution system plan with the public utility commission for review. Requirements for sharing distribution system data and analyses vary widely, from few specific requirements to a detailed list of information that must be provided. While utilities conduct extensive analysis to develop distribution system plans, in most jurisdictions regulators and stakeholders do not know what data are available and how the utility uses the data in planning and investing. This report aims to bridge the gap by increasing understanding of the types of data and analyses utilities employ to develop distribution system plans and how the information affects their decision-making. The report describes information that states and stakeholders can ask for related to 11 data categories: -Forecasting loads and distributed energy resources (DERs) -Scenario analysis -Worst-performing circuits -Asset management strategy -Hosting capacity analysis -Value of DERs -Grid needs assessment -Cost-effectiveness framework for investments -Distribution system investment strategy and implementation -Geotargeted programs -Non-wires alternatives procurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Optimization Workflow Status Update

Economically optimal and safe operation of integrated energy systems (IES) requires optimization at many different time scales. A real-time optimization (RTO) workflow will attempt to maximize revenue and minimize operational costs on a time scale of minutes to hours. Such a workflow requires the use of a digital twin (DT), which is a virtual representation of a physical system. The DT is updated using real-time data from the physical system, and serves as a model in an optimization framework. The optimization results are then sent back to the physical system to complete the loop. This report details the progress made in developing building blocks for a DT/RTO framework. The Risk Analysis Virtual Environment (RAVEN) platform within the Framework for Optimization of Resources and Economics (FORCE) tool suite can perform many of the tasks required for building a DT and performing RTO. The first item of this report details RAVEN enhancements that enable RAVEN workflows to be run in various environments. Data communication between the physical system and its DT is essential for successful RTO. This includes preprocessing real-time data, loading data into a data warehouse, and querying the stored data. The second section of this report describes the progress made in implementing an adapter in Python in order for Deep Lynx to handle the data communication. Typical dispatch optimization frameworks are built on linear programming (LP). The prototype RTO workflow developed in this report uses an LP problem as a part of a receding-horizon- or economic model predictive control (EMPC) based optimization. The third section of this report details the framework of an RTO workflow in which the system consists of a simple electrical storage device. A DT can be built from a reduced-order model (ROM). Integrating a ROM into a typical LP optimization framework has been challenging because most optimization packages require the user to write algebraic expressions for the system model. The final section of this report shows how an externally built RAVEN ROM can be integrated in an RTO framework by using the Python package Pyomo. This demonstrates the RTO workflow capability from a software-only perspective and is an important step in demonstrating the capability to implement an RTO workflow for a physical system.

97 MATHEMATICS AND COMPUTING↗

CalWave - Reports and Plans for xWave Device Demonstration at PacWave South Site

CalWave has developed a submerged pressure differential type Wave Energy Converter (WEC) architecture called xWave. The single body device oscillates submerged, is positively buoyant, and taut moored to the sea floor and integrates novel features such as absorber submergence depth control. Since participation in the US Wave Energy Prize, CalWave has evolved the design and successfully concluded a scaled 10-month open ocean pilot. CalWave recently concluded the final design phase of a scaled up WEC version for PacWave and started component order/build of the WEC towards the grid-connected demonstration at PacWave. Documentation and data here includes: a system certification plan, a risk registry in the form of an FMECA (Failure Mode, Effects, and Criticality Analysis) table, an updated LCOE content model, a report on performance metrics, and a risk management plan.

16 TIDAL AND WAVE POWER↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

Enhancing Modeling and Simulation for Effective Protection Strategies

This report was created by Sandia National Laboratories (SNL) to document the principles and methodology of performance data collection and integration with modeling and simulation tools to better facilitate the performance evaluation of physical protection systems (PPS). Results and conclusions from the use of modeling and simulation tools are only as good as the data employed by the tools when conducting analysis. Acquiring the performance testing data necessary to ensure effective evaluation can be a complex and sometimes daunting process. It is the desire of the organization to provide guidance that eases the burdens associated with pursuit of these objectives. This document draws heavily upon longstanding principles of systems engineering that have been developed and employed by SNL in the discipline of security since the 1970s. The scope of this document is constrained to the testing of system components and integration of data that is applicable within the context of PPS performance analysis using two tools that have been developed by SNL, PathTrace© and Scribe3D©. For guidance related to testing and evaluation more broadly, the manuals and reports referenced by this document can be consulted.

42 ENGINEERING↗

Access Patterns and Performance Behaviors of Multi-layer Supercomputer I/O Subsystems under Production Load

Scientific computing workloads at HPC facilities have been shifting from traditional numerical simulations to AI/ML applications for training and inference while processing and producing ever-increasing amounts of scientific data. To address the growing need for increased storage capacity, lower access latency, and higher bandwidth, emerging technologies such as non-volatile memory are integrated into supercomputer I/O subsystems. With these emerging trends, we need a better understanding of the multilayer supercomputer I/O systems and ways to use these subsystems efficiently. In this work, we study the I/O access patterns and performance characteristics of two representative supercomputer I/O subsystems. Through an extensive analysis of year-long I/O logs on each system, we report new observations in I/O reads and writes, unbalanced use of storage system layers, and new trends in user behaviors at the HPC I/O middleware stack.

Bez, JL↗

Oklo Sponsored Testing using PELICAN: System, Subchannel, and High-Fidelity Software Validation (Final CRADA Report)

Argonne National Laboratory (the Contractor), located in Lemont IL, and Oklo, Inc., (the Participant), headquartered in Santa Clara, CA, propose to enter into a Cooperative Research and Development Agreement (CRADA) to perform a gap analysis of thermal hydraulic data, perform prototypical fuel assembly pressure drop and cavitation model validation, generate the experimental data as well as the corresponding uncertainties for this matrix and, finally, develop the validation models with the Argonne system level code SAS4A/SASSYS-1, the Argonne subchannel analysis code DASSH, the Argonne high fidelity code Nek5000, and/or the Idaho National Laboratory code Pronghorn Subchannel. The work outlined below will significantly improve the experimental and validation database currently available for liquid metal fast reactors, thus making it a viable part of a comprehensive reactor design and licensing suite to be used by the participant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Integrated ML/AI Framework for Digitizing, Structuring and Searching DOE U-TRU-Fuels Data with Gap Analysis of Non-DOE Records

The U.S. Department of Energy (DOE) Advanced Fuels Campaign (AFC) is advancing transmutation fuel technologies to reduce long-lived radioactive waste by converting minor actinides into shorter-lived or stable elements through irradiation in sodium-cooled fast reactors. Key experiments such as AFC-1, AFC-2, FUels for the transmutation of Trans-URanium elements In phéniX (FUTURIX)-Fortes Teneurs en Actinides (FTA), and Experimental Breeder Reactor-II (EBR-II) X501 have provided fuel fabrication, irradiation, and performance data on various transuranic-bearing fuel forms. This report documents the creation of an artificial-intelligence assisted database, which has consolidated all DOE-owned data related to Transuranic (TRU)-bearing fuel experiments and stored across it across both the Idaho National Laboratory (INL) Nuclear Data Management and Analysis System and the INL high performance computing (HPC) infrastructure. A dedicated webpage, hosted on the INL HPC system, has been developed to support role-based access and data interaction. The database architecture allows researchers to navigate large, heterogeneous archives with far greater speed and accuracy than manual search and lays the foundation for future expansion into multimodal nuclear materials analysis environments. The database represents a major step towards a nationally integrated fuels database utilizing artificial intelligence tools.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Decay Curve Correction Analysis Report

The decay curve analysis that is done on the short-lived radionuclide gas samples is used to differentiate between gaseous radionuclides that have the same characteristic gamma decay energy, 511 kiloelectron-volts (keV). A sample of stack gas is isolated and the total counts in the 511 keV peak are counted repeatedly in 10-second intervals to evaluate the decay rate of the sample over time. Analysis of this decay data required a series of steps. First, a raw data report is generated by the gamma acquisition system, based on an analysis template within the acquisition software. The data report file was then loaded into Microsoft Word, and a macro was used to perform minor formatting (remove colons and insert tabs between data columns) to allow analysis within Excel. The file is then saved as a text file at this point. The text file is then uploaded into Excel and a series of macros are used to add labels, calculate radioactive decay constants, and analyze the gamma decay data using linear regression techniques. The analysis template has been used since 1998 for stack 53000303 (TA-53, building 0003, exhaust stack 03) and 2000 for stack 53000702. The overall process, including the gamma report format and the macros used in Word and Excel for processing the report, had remained unchanged until 2015. In October of 2015, staff made a change to the report template in the gamma acquisition software which resulted in an error in the calculations later performed by the Excel macro. This error was not caught until a more in-depth review of the analysis took place regarding 2020 data. This report covers a much more complete review of the issue that occurred regarding the decay curve analysis, a review of the calculations completed to correct the issue, a review of the updated decay curve analysis process, and recommendations for moving forward.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

De-Risking Large-Scale PV Systems Through Data Analytics

Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.

analysis↗

Integrated Risk-Informed Condition Based Maintenance Capability and Automated Platform: Technical Report 3

This project is a collaborative research effort between PKMJ Technical Services LLC, Idaho National Laboratory, and Public Service Enterprise Group (PSEG) Nuclear, LLC. The collaboration, led by PKMJ Technical Services LLC, is part of the industry Funding Opportunity Announcement (FOA) award under Advanced Nuclear Technology Development FOA #DE-FOA-0001817. The pilot demonstration focuses on the Circulating Water System (CWS), an important non-safety-related system that impacts the power generation capability of the plant site. Achieving riskinformed condition-based Predictive Maintenance (PdM) on the CWS will result in significant economic benefits, and the developed methodologies can also be applied to other plant systems. This approach supports an industry goal of ensuring that nuclear power generation remains a viable, economically competitive option in the energy market. Operation and Maintenance (O&M) costs include labor-intensive Preventive Maintenance (PM) programs that involve manually performed inspection, calibration, testing, and maintenance of plant assets at periodic frequencies as well as time-based replacement of assets, irrespective of condition. This project offers an alternative by focusing on riskinformed condition-based maintenance to reduce O&M costs while still maintaining plant health and safety. This report summarizes the progress made toward achieving a risk-informed condition-based maintenance approach. The research and development (R&D) activities presented in this report are associated with development of a nuclear digital platform application, integration of fault signature models, and automated work management processes. The fault signatures and Machine Learning (ML) models are key components in predictive analytics and are heavily leveraged to improve the insights received by existing plant process data sources. Availability of the analysis results within a centralized digital platform enhances efficiency by enabling automation of activities otherwise performed manually. Personnel are presented with enhanced information that can be used to evaluate plant status and risks. Utilizing the enhancements to data analytics supports automated responses, (i.e. issuance of work orders) to address developing equipment faults and thus preventing forced, unplanned shutdowns of components or systems. The R&D activities described within this report lay the foundation for developing and demonstrating a digital automated platform to centralize the implementation of condition monitoring and response to equipment faults. The digital automated platform is cloud-based and designed to enable improved efficiency of plant processes. The digital platform includes content related to maintenance optimization, fault signature analysis, and plant records, which can all be used to support efficiencies when located within a centralized digital platform. These efficiencies could be further enhanced when deployed through industry-wide deployment of the technology to improve insights and processes based upon economies of scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NRC Reactor Operating Experience Analysis and Trend Summary: 2022 Update

This report presents a summary of the Nuclear Regulatory Commission (NRC) reactor operating experience analyses with data through 2022 as well as the reliability and frequency trends identified in the 2022 update reports for component performance study, loss of offsite power analysis, initiating events analysis, and system study provided on the NRC Reactor Operating Experience Results and Databases website (https://nrcoe.inl.gov/).

99 GENERAL AND MISCELLANEOUS↗

A Model Based Approach to Extract Health Information from Textual Data

In current nuclear power plants (NPPs) a large amount of condition-based data is being generated and stored to assess and monitor component health and performance. The format of this data can be either numeric (e.g., pump vibration data) or textual (e.g., condition report which assess component health). While assessing component health from numeric data can be performed with a large variety of methods, the extraction of information from textual data still remains a challenge. Natural language processing (NLP) methods are starting to be deployed in current NPPs mainly to filter out incident reports (IRs) that are not safety related by employing supervised machine learning methods. However, these methods do not really provide the quantitative information that might be contained in IRs. This paper presents an approach to extract information from textual data (e.g., from IRs, maintenance reports) that is based on NLP data analytics methods coupled with model-based system engineer (MBSE) models. NLP methods are employed to perform syntactic and semantic analyses. Syntactic analysis analyzes the grammatical structure of a sentence; such analysis includes: part of speech (POS) tagging (i.e., identification of grammatic elements of each string - e.g., nouns, verbs), named entity recognition (i.e., identification of text entities - e.g., names, dates, events), and relation extraction (e.g., coreference resolution). On the other hand, semantic analysis is designed to analyze the logic structure of a sentence. Through a specific set of rules, our methods can identify whether a sentence contains health information of a component (e.g., degraded performance, anomaly behavior) or the causal relationship between two events (i.e., a cause-effect pair). An innovative element of our approach is that semantic analysis relies on MBSE models to identify links between textual elements. MBSE are diagrams designed to represent system and component dependencies (from both a form and functional point of view). In our approach, MBSE models emulate system engineer knowledge about component/system architecture. This paper presents in detail how the integration of NLP methods and MBSE models is performed. Few analysis examples focusing on centrifugal pumps are presented.

97 - MATHEMATICS AND COMPUTING↗

UNF-ST&DARDS Enhancements for RCCA Data in As-loaded Dual Purpose Cask Models

This report summarizes the work performed to enable detailed modeling of rod cluster control assembly (RCCAs) in dual purpose canisters (DPCs) in as-loaded configurations using the Used Nuclear Fuel – Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). The goal of this project was to evaluate the reactivity impact that RCCAs have on k eff of DPCs with pressurized water reactor (PWR) fuel to potentially use the additional margin in future post-closure criticality safety analysis. This preliminary evaluation determined the number of DPCs that currently require compensatory actions prior to emplacement in a repository because of their high reactivity under post-closure criticality scenarios, which could be made acceptable by including the as-loaded RCCAs as specified in the Unified Database (UDB). This report briefly describes the modeling methods currently used within UNF-ST&DARDS and the modifications made to automate inclusion of the as-loaded RCCAs in the DPCs for post-closure criticality calculations for the loss of neutron absorber (NA) scenarios, or NA models. For the Zion site, the loss of basket scenarios, or degraded basket (DB) models, are also included. Discussion is also provided regarding the UDB data compared to available site-specific loading map data for the sites, which are specifically evaluated herein. This report compares the modifications to a similar evaluation for the Zion by site conducted by Walker as an initial validation. After the partial validation, all existing PWR sites with applicable NA models within the UDB were evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ROOT RNTuple and EOS: The Next Generation of Event Data I/O

For several years, the ROOT team is developing the new RNTuple I/O subsystem in preparation of the next generation of collider experiments. Both HL-LHC and DUNE are expected to start data taking by the end of this decade. They pose unprecedented challenges to event data I/O in terms of data rates, event sizes, and event complexity. At the same time, the I/O landscape is becoming more diverse. HPC cluster file systems and object stores, NVMe disk cache layers in analysis facilities, and S3 storage on cloud resources are mixing with traditional XRootD-managed spinning disk pools.The ROOT team will finalize a first production version of the RNTuple binary format by the end of 2024. After this point, ROOT will provide backward compatibility for RNTuple data. This contribution provides an overview of the RNTuple feature set, the related R&D activities and the long-term vision for RNTuple. We report on performance, interface design, tooling, robustness, integration with experiment frameworks, and validation results, as well as recent R&D on parallel reading and writing and exploitation of modern hardware and storage systems. We will give an outlook on possible future features after a first production release.Collaboratively, the IT and EP departments at CERN have launched a formal project within the Research and Computing sector to evaluate the novel data format for physics analysis data utilized in LHC experiments and other fields. This part of the project focuses on validating the scalability of the EOS storage backend during the transition from the over 25 years old TTree production format to the newly developed RNTuple format, using both replicated and erasure-coded storage profiles.

Blomer, Jakob [CERN]↗

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]↗