Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance Assessment of Fluidic Oscillators Tested on the NASA Hump Model

Flow separation control over a wall-mounted hump model was studied experimentally to assess the performance of fluidic oscillators (sweeping jet actuators). An array of fluidic oscillators was used to control flow separation. The results showed that the fluidic oscillators were able to achieve substantial control over the separated flow by increasing the upstream suction pressure and downstream pressure recovery. Using the data available in the literature, the performance of the fluidic oscillators was compared to other active flow control (AFC) methods such as steady blowing, steady suction, and zero-net-mass-flux (ZNMF) actuators. Several integral parameters, such as the inviscid flow comparison coefficient, pressure drag coefficient, and modified normal force coefficient, were used as quality metrics in the performance comparison of the AFC methods. These quality metrics indicated the superiority of the steady suction method, especially at lower excitation amplitudes that is followed by the fluidic oscillators, steady blowing, and the ZNMF actuators, respectively. An aerodynamic figure of merit (AFM) was also constructed using the integral parameters and AFC power usage. The AFM results revealed that, for this study, steady suction was the most efficient AFC method at lower excitation amplitudes. The steady suction loses its efficiency as the excitation amplitude increases, and the fluidic oscillators become the most efficient AFC method. Both the steady suction and the fluidic oscillators have an AFM > 1 for the range tested in this study, indicating that they provide a net benefit when the AFC power consumption is also considered. On the other hand, both the steady blowing and ZNMF actuators were found to be inefficient AFC methods (AFM < 1) for the current configuration. Although they improved the flow field by controlling flow separation, the power requirement was more than their benefit.

Fluidic oscillators↗

A Performance Assessment of Eight Low-Boom High-Speed Civil Transport Concepts

A performance assessment of eight low-boom high speed civil transport (HSCT) configurations and a reference HSCT configuration has been performed. Although each of the configurations was designed with different engine concepts, for consistency, a year 2005 technology, 0.4 bypass ratio mixed-flow turbofan (MFTF) engine was used for all of the performance assessments. Therefore, all original configuration nacelles were replaced by a year 2005 MFRF nacelle design which corresponds to the engine deck utilized. The engine thrust level was optimized to minimize vehicle takeoff gross weight. To preserve the configuration's sonic-boom shaping, wing area was not optimized or altered from its original design value. Performance sizings were completed when possible for takeoff balanced field lengths of 11,000 ft and 12,000 ft, not considering FAR Part 36 Stage III noise compliance. Additionally, an arbitrary sizing with thrust-to-weight ratio equal to 0.25 was performed, enabling performance levels to be compared independent of takeoff characteristics. The low-boom configurations analyzed included designs from the Boeing Commercial Airplane Group, Douglas Aircraft Company, Ames Research Center, and Langley Research Center. This paper discusses the technology level assumptions, mission profile, analysis methodologies, and the results of the assessment. The results include maximum lift-to-drag ratios, total fuel consumption, number of passengers, optimum engine sizing plots, takeoff performance, mission block time, and takeoff gross weight for all configurations. Results from the low-boom configurations are also compared with a non-low-boom reference configuration. Configuration dependent advantages or deficiencies are discussed as warranted.

Baize, Daniel G.↗

Incorporating the Impacts of Climate Change on Hydrology in a Performance Assessment Model - 20403

The evidence of climate change is increasingly well-documented and impacts should be incorporated in performance assessment studies. The current climate literature provides both observational evidence and climate model projections of climate trends and/or climate change in the late 20. and early 21. centuries for North America and the northeast United States. Probabilistic modeling is a core requirement for quantifying uncertainty and evaluating its impacts. Not evaluating future climate states in a performance assessment because of the existence of uncertainty is contradictory to good modeling practices - the most uncertain issues and parameters require the most attention in effective probabilistic modeling. Excluding climate change limits development of modeling information that could aid in effective decision making. In this work we develop methods to use the output from hydrologic models and analysis of historical aerial imagery to quantify and implement the impacts of climate change on hydrologic processes at a nuclear waste site in West Valley, New York. Specifically, we used the HELP (Hydraulic Performance of Landfill Performance) model to characterize key hydrologic processes under both current and future climate conditions to assess the impacts of changing climate on hydrology. A suite of previous climatic models were reviewed and synthesized to produce a cohesive representation of the current state of knowledge of the impact of climate change on important model inputs such as precipitation. Output from the HELP simulations was coupled to the GoldSim model that was used to develop the Probabilistic Performance Assessment (PPA) approach through the application of a novel 'nearest neighbor' technique. First, several thousand realizations were generated from the HELP model using a Latin Hypercube experimental design to ensure adequate coverage of the parameter space of explanatory variables used to drive HELP. For example, porosity is a physical parameter that is used as an input to both HELP and the GoldSim PA model. We then ran sensitivity analysis (SA) algorithms on the output of HELP for each of the responses of interest. For each predictor, each time we build an SA model we get a different value for the sensitivity index (SI). From the collection of all the SA models, the average was computed among all of the SIs to represent the predictor within the context of the nearest neighbor approach. That is, we conduct SA on each HELP outcome for each scenario. This gives us parameter sensitivity indices for the outcomes. We average the parameter sensitivity indices across the outcomes to get the average SI for a scenario. For each realization that is generated from the Goldsim PA model, Goldsim generates random values for physical/empirical parameters that HELP uses as well. For each vector of physical/empirical parameters that Goldsim generates, the vector from the 5,000 HELP runs that is most 'similar' to the Goldsim vector is computed using the nearest neighbor approach. In this context 'similar' means minimization of the SA-weighted sum of the absolute differences among the 5,000 values computed for this statistic, where each value corresponds to a different HELP realization. In order to account for the impacts of climate change, this process was repeated using the spatially downscaled future climate projections. For each of the key parameters of interest, it was assumed that a linear change depicted the relationship between the values for the present day and those for 2100. In this way, the climatically-driven changes in key parameters used to inform the GoldSim model are quantified and incorporated into the PA model output for the future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance assessment for climate intervention (PACI): preliminary application to a stratospheric aerosol injection scenario

As the prospect of exceeding global temperature targets set forth in the Paris Agreement becomes more likely, methods of climate intervention are increasingly being explored. With this increased interest there is a need for an assessment process to understand the range of impacts across different scenarios against a set of performance goals in order to support policy decisions. The methodology and tools developed for Performance Assessment (PA) for nuclear waste repositories shares many similarities with the needs and requirements for a framework for climate intervention. Using PA, we outline and test an evaluation framework for climate intervention, called Performance Assessment for Climate Intervention (PACI) with a focus on Stratospheric Aerosol Injection (SAI). We define a set of key technical components for the example PACI framework which include identifying performance goals, the extent of the system, and identifying which features, events, and processes are relevant and impactful to calculating model output for the system given the performance goals. Having identified a set of performance goals, the performance of the system, including uncertainty, can then be evaluated against these goals. Using the Geoengineering Large Ensemble (GLENS) scenario, we develop a set of performance goals for monthly temperature, precipitation, drought index, soil water, solar flux, and surface runoff. The assessment assumes that targets may be framed in the context of risk-risk via a risk ratio, or the ratio of the risk of exceeding the performance goal for the SAI scenario against the risk of exceeding the performance goal for the emissions scenario. From regional responses, across multiple climate variables, it is then possible to assess which pathway carries lower risk relative to the goals. The assessment is not comprehensive but rather a demonstration of the evaluation of an SAI scenario. Future work is needed to develop a more complete assessment that would provide additional simulations to cover parametric and aleatory uncertainty and enable a deeper understanding of impacts, informed scenario selection, and allow further refinements to the approach.

climate intervention↗

Development of PFLOTRAN Transport Capability for Use in the Waste Isolation Pilot Plant Performance Assessment - 20545

Waste Isolation Pilot Plant (WIPP) performance assessment (PA) calculations estimate the probability of radionuclide release from the repository to the land surface and across the land withdrawal boundary for a regulatory period of 10,000 years after facility closure. Simulations of flow and transport in the repository and the surrounding Salado Formation are foundational to the PA. Because proposed additional waste emplacement panels would result in an asymmetric repository layout, the US Department of Energy (DOE) is preparing to transition to use of a three-dimensional (3-D) model domain for simulation of flow and transport instead of the two-dimensional (2-D) flared grid domain currently used. DOE has charged Sandia National Laboratories with developing the capability necessary to simulate processes affecting flow and transport in the WIPP in PFLOTRAN, an open-source massively parallel multi-phase flow and reactive transport code. The new flow and transport capabilities developed in PFLOTRAN incorporate WIPP-specific process models and will replace the 2-D simulators (BRAGFLO and NUTS) that are currently utilized for Salado flow and transport calculations in WIPP PA. The focus of this paper is on the development of a new Nuclear Waste Transport (NWT) mode in PFLOTRAN that has all of the capabilities necessary for Salado transport simulations, including the ability to handle complete dry-out (100% gas saturation) of arbitrary cells in the model domain, radionuclide mass conservation at step changes in porosity associated with borehole intrusion, and the ability to calculate fluxes on a flared grid. The new PFLOTRAN transport capability and a suite of verification tests were designed around a list of functional requirements for WIPP PA calculations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of Computational Fluid Dynamics Simulations for Biological Performance Assessment in Hydropower units (Final Report)

The biological performance assessment (BioPA) toolset developed by Pacific Northwest National Laboratory (PNNL) estimates the relative biological performance of fish passage at a hydroelectric power turbine unit. The tool is based on the use of computational fluid dynamics (CFD) and fish biological response relationships. The recent release, BioPA-v3, is based on directly computed trajectory and collision of material Lagrangian particles using CFD simulation codes rather than the prior version that relies on Tecplot to compute streamtrace trajectories. Before modifying the toolset, a series of validation tests were performed at the various steps of modification in the toolset. Validation is a critical step of any numerical investigation that reflects the accuracy and reliability of the predicted results. It raises the confidence level of the user to use the modified version of the BioPA toolset. Several test cases were simulated and compared, where available, to observed data. The trajectory and collision of the small spherical and cylindrical particles in a water flume were compared to in-house experiments. The CFD predicted collision rate and flow field compared well with experimental observation for vane array and large cylinder as target bodies. Next, the CFD-predicted flow field and hydraulic performance of a laboratory-scale model of a Francis turbine was also successfully validated. Note that the trajectory of the particles is significantly affected by the flow field in such extreme conditions. In addition to the particle trajectories and flow field, the collision detection method employed in the CFD simulations was also successfully validated. The CFD predicted impact velocity, collision time, velocity, and trajectory of a sphere excellently matched with analytical value for a bouncing ball in the elastic collision. A similar approach was also tested and successfully validated for a collision of sphere with a 45° inclined plane. After successfully validating different cases, the BioPA toolset was modified to use direct output of the CFD prediction and the new version can be used in evaluating biological performance at hydroelectric turbines.

13 HYDRO ENERGY↗

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study to validate the Non-Interference Performance Assessment (NIPA) technique

The NIPA (Non-Interference Performance Assessment) technique involves direct observation of group verbal activities by trained observers who rate the emotional content (affect) of each verbal interaction as either positive, negative, or neutral. During the test, in which four men were confined for 90 consecutive days, feasibility of the NIPA technique was demonstrated and observer reliability was verified. However, the validity of the test was not proved because an independent criterion measure of morale for the confined crew was lacking. There were indications, however, that NIPA measures were tracking changes in crew morale. At approximately the two-thirds point (Days 60 to 70), morale apparently fell dramatically for a period of about ten days, and simultaneously NIPA measure of positive verbalization decreased in number. A need was indicated for a separate study to apply the NIPA technique under experimental conditions and using a clearly defined criterion measure against which the ability of NIPA observations to truly measure morale changes could be determined.

Seeman, J. S.↗

Risk-informed Graded Approach for Reliability and Performance Assessment of Machine Learning and Artificial Intelligence for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

97 - MATHEMATICS AND COMPUTING↗

Risk-informed Graded Approach for Reliability and Performance Assessment for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

99 - GENERAL AND MISCELLANEOUS↗

Standard Analysis Report INV-SAR-81, Revision 0 Chemical and Cement Components 2023 Inventory Estimates for the Interim State Performance Assessment of the Waste Isolation Pilot Plant

This standard analysis report provides the estimates for the chemical (oxyanions and complexing agents) and cement components with a data collection cut-off date of December 31, 2023. These estimates will be included in a Performance Assessment Inventory Report developed for the U.S. Department of Energy (DOE) interim state repository configuration performance assessment (PA) for the 2026 Compliance Recertification Application (CRA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling glass degradation and release of radionuclides from vitrified waste for performance assessment simulations

The release of radionuclides initially encapsulated in a slowly degrading solid waste form and contained in an eventually corroding canister defines the source term for numerical simulations for the assessment of a geologic repository for high-level radioactive waste. While the details of waste degradation, canister corrosion, and dissolution and mobilization of the radionuclides in pore water include complex chemical reaction and transport processes that are coupled to the thermal, hydrological, microbiological, and mechanical conditions in the repository, the source-term model suitable for use in a numerical performance assessment model should be a defensible abstraction of these mechanisms. We developed a radiological source-term model and implemented it into a non-isothermal flow and transport simulator. While the proposed source-term model is applicable to various waste forms, canister systems, and disposal concepts, we specifically considered radionuclide releases from vitrified high-level waste placed in a cylindrical canister disposed in a deep vertical borehole repository. In this model, waste degradation is a function of temperature, and it can be adjusted to evaluate the influence of and propagate uncertainties in pH, passivation reactions, and chemical conditions as well as geometrical factors. The time-dependent, congruent release of safety-relevant radionuclides present in the decaying inventory is then calculated. Finally, the radionuclides are mobilized by diffusive and advective transport according to the thermo-hydraulic conditions prevailing in the near field of the repository, from where they migrate through the geosphere to the accessible environment. We examine the influence of the source-term model’s parameters on performance assessment calculations through sensitivity and uncertainty propagation analyses, identifying influential factors and confirming the upper bound of their impact. These considerations align with the overarching goal of repository design, which is to demonstrate that engineered and natural barriers can collectively delay radionuclide migration for timescales far exceeding human planning, thereby providing multiple, redundant barriers against environmental contamination.

iTOUGH2↗

Sensor Performance Assessment for Terra and Aqua MODIS Using Unscheduled Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) has been in operation for over 18 and 16 years on the Terra and Aqua spacecrafts, respectively. In order to maintain long-term calibration stability over the life of each mission, MODIS uses a set of on-board calibrators as well as observations of the Moon and selected Earth-view targets. The lunar observations nominally occur in a narrow phase angle range, 55 degrees - 56 degrees, and use scheduled spacecraft maneuvers in order to bring the Moon into alignment with the MODIS space-view port. These observations are used to help characterize the MODIS scan-mirror response versus scan-angle. In addition to these scheduled lunar observations, MODIS also views the Moon through the space-view port without a spacecraft maneuver when the geometry is appropriately aligned. This occurs over a wider phase angle range, between 51 degrees - 82 degrees, than those of the scheduled moon observations. While the phase angle restriction of our scheduled observations provides consistency between the calibration events, the unscheduled Moon data can provide a valuable assessment of many calibration related investigations that use the Moon. In this paper, we compare the results of unscheduled versus scheduled lunar observations for several sensor calibration and performance assessments. These include the lunar calibration trending used to characterize the scan-mirror response versus scan angle and the electronic crosstalk correction of bands 27-30, which are currently used in the MODIS Level-1B data products, as well as sensor performance assessments such as band-to-band and detector-to-detector spatial registration.

Aqua↗

Performance Assessment Maintenance Plan for the Active Low-Level Burial Ground Trenches 31, 34, and 94 at the Hanford Site

This report documents the maintenance plan for the Hanford Site 200 West Area Active Low-Level Burial Ground Trenches 31 and 34 and 200 East Area Active Trench 94 performance assessment (PA). The PA maintenance plan is one of several supporting documents that are compendiums to the active trenches (Trenches 31, 34, and 94) PA as required in DOE O 435.1, Radioactive Waste Management . The PA is documented in DOE/RL-2021-26, Performance Assessment of Active Trenches in 200 East and West Low-Level Burial Grounds at the Hanford Site . This plan follows the requirements and outline specified in the applicable U.S. Department of Energy (DOE) standard used for developing documents supporting DOE-STD-5002-2017, Disposal Authorization Statement and Tank Closure Documentation . This maintenance plan summarizes the following major activities DOE plans to conduct to maintain the Trenches 31, 34, and 94 PA: Monitoring; Research and development; Planned reviews and analyses; Revisions of Trenches 31, 34, and 94 PA. The planned research and development activities relate to evaluating the key assumptions, including evaluating conceptual model assumptions and parameter value assumptions used in the PA. The planned research and development activities include those that are designed to track the release mechanisms for Category 1, Category 3, and uranium billet waste sources, as well as continued characterization and related modeling of the natural environment in the Central Plateau of the Hanford Site. In addition, the planned research and development activities include focused testing and evaluation of engineered and natural materials to reduce the uncertainty in the conceptual models and parameter values used in the PA. All key and secondary issues identified during the review of the PA by the Low-Level Waste Disposal Facility Federal Review Group have been resolved prior to finalization of the PA. There are no outstanding issues.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 80: Interagency Community of Practice in Risk and Performance Assessment

This panel focused on the status of the Inter-agency Performance and Risk Assessment Community of Practice (P and RA COP). Representatives from the P and RA COP and subject matter experts discussed lessons learned and provided feedback on building the P and RA COP to support risk-informed environmental decision making. Panelists with presentations: Understanding Mechanisms to Manage Uncertainty and Risk in Waste Containment Systems (Craig Benson, University of Virginia - CRESP (USA) Scaling for Performance Assessments (Paul Black, Katie Catlett, Doug Anderson, Paul Duffy, Tom Stockton, Sam Van Sickle, John Carson); Interagency Community of Practice in Rick and Performance Assessment (Horst Monken Fernandes); Institutional Controls as a Risk Management Tool (David Esh); Superfund: Explanation of Screening and PRG's for Risk and Dose Assessment (Stuart Walker)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Geostationary Lightning Mapper (GLM) Navigation Performance with the INR Performance Assessment Toolset (IPATS)

The GOES-R flight project has developed the Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) to perform independent INR evaluations of the optical instruments on the GOES-R series spacecraft. In this presentation, we document the development of navigation (NAV) evaluation capabilities within IPATS for the Geostationary Lightning Mapper (GLM). We also discuss the post-processing quality filtering developed for GLM NAV, and present example results for several GLM background image datasets. Initial results suggest that GOES-16 GLM is compliant with navigation requirements.

Isaacson, Peter J.↗

Impact of gas injection location and divertor surface material on ITER fusion power operation phase divertor performance assessed with SOLPS-ITER *

Abstract The ITER divertor design and performance assessment, primarily based on the SOLPS-4.3 burning plasma database (Pitts R. et al 2019 Nucl. Mater. Energy 20 100696), assumes the use of beryllium (Be) as the divertor surface material and the injection of gas from the main chamber top. However, the current ITER baseline favors gas injection from the more toroidally symmetric sub-divertor region. This paper evaluates the implications of these assumptions for divertor performance in the ITER fusion power operation phase. The impact of the divertor surface material and the gas injection location on the main ions mirrors the hydrogen only low power phase scenario shown in Park J.-S. et al (2020 Nucl. Fusion 61 016021). However, during burning plasma operation, extrinsic impurity seeding will be required. In the case of neon (Ne), studied here, impurity retention is influenced by both the divertor surface material and the fueling location. Neon leakage increases due to more energetic reflection from tungsten than beryllium, but equivalent divertor performance can be achieved by adjusting the neon seeding rate. While the impurity seeding location does not affect the distributions of impurity or radiation, the fueling location does. Top fueling provides local ionization sources mainly in the mid-SOL under detached conditions, enhancing divergences of the flux there (source-driven flow), bringing stagnation points close to the fueling location, and equilibrating flows towards both targets. In contrast, the global flow pattern (in the absence of fluid drifts) in the case of sub-divertor fueling is biased towards the inner target. Impurity flows, driven by force balance, largely mirror those of the main ion flow, including the stagnation point. The case with top fueling enhances Ne retention and corresponding radiation in the outer divertor, effectively reducing the total and peak target heat fluxes by 20%–40%, compared to the case with divertor fueling. Meanwhile, the case with outer target fueling also achieves similar reductions by enhancing plasma-neutral interactions. These results suggest the possibility that the selection of the fueling location and throughput can be used as an actuator to control impurity divertor retention and divertor radiation asymmetry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗