Search NASA⌕ Search

SEARCH · Search NASA

Results for “Periodic Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sudden collapse of a pressure profile generated by off-axis heating in a linear magnetized plasma

Here, the features of an unexpected, large event that arises spontaneously during a basic heat transport experiment are presented. It consists of the sudden collapse of the radial plasma pressure profile, akin to disruption events observed in toroidal magnetic confinement devices. The experiment is performed on the Large Plasma Device at the University of California, Los Angeles (UCLA). It uses a LaB6 thermionic emitter of annular shape to induce off-axis heating of a cold, afterglow plasma, in a linear magnetic geometry. The temporal evolution consists of three regimes. During an early, quiescent period, classical heat transport along and across the magnetic field arises from Coulomb collisions. After significant pressure gradients develop, drift-Alfvén waves become unstable. Upon reaching large amplitude, they trigger avalanche events that flatten the outer part of the heated region, which, in turn, quenches the instability. Due to the sustained heating, the pressure profile rebuilds and the process repeats, leading to a relatively long, second regime that displays multiple avalanches, but suddenly, the annular pressure profile is observed to collapse. After this collapse, the system enters a third regime with large fluctuations. Before the collapse, a rapid, runaway heating environment arises whose time evolution exhibits a self-similar dependence on the applied voltage. The time evolution, morphology, and scaling of the collapse event are presented, and an examination is made of the underlying mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hierarchical triply periodic minimal surface structures as heat exchangers and reactors

The present disclosure relates to a transport mechanism apparatus for transporting at least one of a gas or a fluid. The transport mechanism may have an inlet, an outlet and a triply periodic minimal surface (TPMS) structure. The TPMS structure is formed in a layer-by-layer three dimensional (3D) printing operation to include cells propagating in three dimensions, where the cells include wall portions having openings, and where the cells form a plurality of flow paths throughout the transport mechanism from the inlet to the outlet, and where the cells form the inlet and the outlet.

Roy, Pratanu↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

ThO 2 and Th 1– x U x O 2 Nanoscale Materials and Thin Films for Nuclear Science Applications

This study investigates the dynamics and mechanisms of solution combustion synthesis (SCS) for the preparation of nanoscale ThO 2 and Th 1–x U x O 2 materials, utilizing metal nitrates (Th(NO 3 ) 4 and UO 2 (NO 3 ) 2 ) and acetylacetone (C 5 H 8 O 2 ) as reactants dissolved in a 2-methoxyethanol (C 3 H 8 O 2 ) solvent. By combining thermodynamic calculations, dynamic time–temperature profile measurements with differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA), this research reveals how variations in acetylacetone concentration and uranium content influence the structural parameters of the synthesized oxides. The time–temperature measurements show that the heating rate and maximum combustion temperatures are sensitive to acetylacetone concentration. DSC-TGA results indicate shifts in exothermic peak temperatures as the uranium content changes. The complexation between thorium and acetylacetone emerges as a critical factor, impacting combustion parameters and the structural characteristics of the final products. The uniform distribution of Th and U in the Th 1–x U x O 2 solid solution and the formation of nanoscale particles with strained crystallites are considered essential for the low-temperature densification of these materials for nuclear fuel pellet applications. Additionally, high-quality ThO 2 and Th 1–x U x O 2 thin (100–150 nm) films are successfully synthesized via electrospray deposition of combustible solutions followed by a brief period of heat treatment. Furthermore, these films exhibit excellent structural and morphological uniformity, making them ideal candidates for nuclear measurements, irradiation damage studies, and investigations into the physical properties of both pure and mixed oxides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy's Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

closed-loop geothermal systems↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy’s Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

Closed-loop geothermal systems, hot-dry-rock, hot-↗

Failure analysis of field-failed bypass diodes

Defective bypass diodes are often found as the largest factor leading to power loss in solar modules. Here, we report on failure mechanisms by investigating shunted bypass diodes from a rooftop installation, using a combination of multiple characterizations including current–voltage analysis, thermal-runaway testing, X-ray computed tomography, lock-in thermography, focused ion-beam cross-section imaging, chemical decapsulation, optical microscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Differing from static discharge typically associated with lightning strikes on modules, we found diode failure by the mechanism of thermal damage under continuous, long-term overstress in forward bias. Our conclusion is based on evidence of energy dissipated—the small to medium extent of melt-through on the Schottky diode face. The diode failure shows distortions or roughening of the Schottky diode metal-semiconductor interface with the die attach, and some failures are accompanied by die-attach solder melting. We propose that nonuniform irradiance on the modules caused diode shunting due to extended periods of heat dissipation in the modules, because modules in this string were placed in two different orientations. In contrast, a second parallel module string of the same module type on the same rooftop with a unique plane of array did not show any diode failures. The thermal damage failure of melt-through was caused by the long-term current generated by overstressing of diodes that may have had crystalline and impurity defects.

14 SOLAR ENERGY↗

Investigating the potential of a higher reactivity fuel to achieve faster heat-up of aftertreatment systems

Shortening the aftertreatment system heat-up period will be crucial to meet upcoming emissions regulations, which mandate significant reductions in tail-pipe emissions for on-road heavy-duty vehicles. This work studies the impact of increasing fuel reactivity on the combustion of post injections during the expansion stroke. The work demonstrates an operating strategy using a blend of di-butyl ether (a potential low-carbon biofuel component) and #2 diesel that achieves higher exhaust enthalpy, while maintaining similar engine-out emissions (NOx and combustion efficiency) in comparison to the baseline #2 diesel fuel (cetane number 41). On average, a 12% increase in exhaust enthalpy was observed for the blend (cetane number 60) relative to the baseline fuel. The ability to operate the higher reactivity fuel at a more retarded post-injection timing, where combustion with #2 diesel was found to be more unstable, and less complete was key to achieving higher exhaust enthalpy. However, a small fuel penalty (3%–5%) was also associated with the higher reactivity fuel with this operating strategy. The formation of fuel lean regions, due to the long ignition delays at late injection conditions, was predicted to be the leading contributor to the increased emissions of products of partial combustion. Here, chemical kinetic simulations using surrogates for the fuels used in the experiments, demonstrated the ability of a higher cetane fuel to outperform the baseline fuel under fuel lean conditions with equivalence ratios less than 0.7.

09 BIOMASS FUELS↗

Causal Interactions between Southern Ocean Polynyas and High-Latitude Atmosphere–Ocean Variability

Abstract Weddell Sea open-ocean polynyas have been observed to occasionally release heat from the deep ocean to the atmosphere, indicating that their sporadic appearances may be an important feature of high-latitude atmosphere–ocean variability. Yet, observations of the phenomenon are sparse and many standard-resolution models represent these features poorly, if at all. We use a fully coupled, synoptic-scale preindustrial control simulation of the Energy Exascale Earth System Model (E3SMv0-HR) to effectively simulate open-ocean polynyas and investigate their role in the climate system. Our approach employs statistical tests of Granger causality to diagnose local and remote drivers of, and responses to, polynya heat loss on interannual to decadal time scales. First, we find that polynya heat loss Granger causes a persistent increase in surface air temperature over the Weddell Sea, strengthening the local cyclonic wind circulation. Along with responding to polynyas, atmospheric conditions also facilitate their development. When the Southern Ocean experiences a rapid poleward shift in the circumpolar westerlies following a prolonged negative phase of the southern annular mode (SAM), Weddell Sea salinity increases, promoting density destratification and convection in the water column. Finally, we find that the reduction of surface heat fluxes during periods of full ice cover is not fully compensated by ocean heat transport into the high latitudes. This imbalance leads to a buildup of ocean heat content that supplies polynya heat loss. These results disentangle the complex, coupled climate processes that both enable the polynya’s existence and respond to it, providing insights to improve the representation of these highly episodic sea ice features in climate models.

Kaufman, Zachary S.↗

Thermal storage system with coupled tanks

Methods and apparatus are disclosed for high-efficiency thermal storage with a fluid-filled “battery” tank positioned within a fluid-filled “reservoir” tank. Fluid loops couple the tanks to a heat pump and a building. The heat pump can charge the battery tank or deliver thermal energy (cold or heat) to a building, using the reservoir tank or ambient air as a thermal energy source. The battery tank can discharge energy to the building jointly with the heat pump or, at periods of peak electricity usage, with the heat pump switched off. Operating modes allow significant savings in electricity usage and mitigate the “duck curve.” Low duty cycle usage of the reservoir enables efficient underground thermal storage with less digging than conventional geothermal technologies. Additional efficiency is achieved with phase change materials installed inside a tank or in a tank wall, providing temperature regulation. Control methods are disclosed.

15 GEOTHERMAL ENERGY↗

Pathways of clean energy heating electrification programs for reducing carbon emissions in Northwest China

We report clean energy heating electrification programs provide a promising way to reduce carbon emissions from fossil fuel combustion and consumption. This work studies the cost competitiveness of clean energy heating technologies under three dynamic mechanisms: investment costs, subsidy policies, and operating costs with real data. It provides key insights into the cost competitiveness of the different heating technologies deployed in different areas, as well as their sensitivity to the three dynamic mechanisms. The results show that currently, the distinct heating programs are more cost-efficient in the urban area with existing heating networks. The average payback period of all district clean energy heating programs in the urban area is 14.9 years, while that of the individual clean heating programs is 24.7 years. The individual heating programs are becoming increasingly cost-competitive with the incentive mechanisms, especially the electricity pricing mechanisms. Moreover, individual heating technologies present remarkable advantages on flexibility and sustainability in the long run. According to the technology diffusion model proposed in this paper, the individual clean heating programs will occupy more than 50% of the market share in 2050 under the comprehensive effect of CAPEX, government subsidies, and OPEX. The real-world results and analysis render references to shape the pathway of clean energy heating electrification in Northwest China and other regions with a similar situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

Saturation and decay of an induced scattering instability driven by static field asymmetries in a non-neutral plasma

Experimental data on the saturation and decay of a previously described induced scattering instability are presented. The instability is driven by static background field asymmetries and initially produces a single growing mode (ω 1 , k 1 ). As the instability develops, several harmonically related (ω n =nω 1 , k n =nk 1 ) eigenmodes of the plasma column grow up, resulting in a spatially localized moving potential perturbation with δϕ/T ≈ 20%. After a period of rapid growth, the mode amplitudes saturate and vary slowly for roughly 10 5 ω 1 −1 . This quasi-equilibrium ends with an unusual change in the eigenmode phases, wherein δϕ changes from positive to negative. Plasma heating during this period increases the damping of all modes and rapidly quenches the instability. This instability is of particular interest because the coupling with the field asymmetry produces an enhanced level of radial transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

The Onset of Nucleate Boiling Prediction in a Mini Channel with the Eulerian Multiphase Flow

The prediction of boiling incipience is a critical issue for a reactor. Vapor lock causes operating instability and undesirable temperature rise, especially for small channels. This study uses the Eulerian multiphase flow boiling model to predict the onset of nucleate boiling in a millimeter scale rectangular channel. Two wall boiling models, namely the RPI (Rensselaer Polytechnic Institute) and the non-equilibrium sub cooled model are applied. Computational fluid dynamics is employed for this study to investigate the impact of operating conditions like liquid flow rate, operating pressure, heat flux, velocity profile, turbulence model, and inlet liquid temperature. Here, the effect of fundamental boiling parameters on the surface wall temperature and vapor volume fraction is also studied. The parameters under consideration are the bubble departure diameter, bubble departure frequency, nucleate site density, quenching time period, and interface heat transfer coefficients. A series of CFD calculations is conducted by varying the considered variables systematically in a wide range of flow conditions covering laminar, transition, and turbulent flows. The sub-component heat fluxes like the liquid convective, the vapor convective, the evaporative, and the quenching terms are monitored to infer the boiling dynamics in the transition region from the single-phase flow to the nucleate boiling zone. It is found that the CFD approach to detecting the boiling incipience point agrees reasonably with available experimental data. However, its limitations, like inaccuracy for lower flow rates and early transition to boiling flow, are also noticed due to the nature of the considered RPI model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗