Inhomogeneous phase shifting: an algorithm for nonconstant phase displacements

In this work, we have developed a different algorithm than the classical one on phase-shifting interferometry. These algorithms typically use constant or homogeneous phase displacements and they can be quite accurate and insensitive to detuning, taking appropriate weight factors in the formula to recover the wrapped phase. However, these algorithms have not been considered with variable or inhomogeneous displacements. We have generalized these formulas and obtained some expressions for an implementation with variable displacements and ways to get partially insensitive algorithms with respect to these arbitrary error shifts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stochastic characterization of phase detection algorithms in phase-shifting interferometry

Phase-shifting interferometry (PSI) is the preferred non-contact method for profiling sub-nanometer surfaces. Based on monochromatic light interference, the method computes the surface profile from a set of interferograms collected at separate stepping positions. Errors in the estimated profile are introduced when these positions are not located correctly. In order to cope with this problem, various algorithms that minimize the effects of certain types of stepping errors (linear, sinusoidal, etc.) have been developed. Despite the relatively large number of algorithms suggested in the literature, there is no unified way of characterizing their performance when additional unaccounted random errors are present. Here, we suggest a procedure for quantifying the expected behavior of each algorithm in the presence of independent and identically distributed (i.i.d.) random stepping errors, which can occur in addition to the systematic errors for which the algorithm has been designed. As a result, the usefulness of this method derives from the fact that it can guide the selection of the best algorithm for specific measurement situations.

42 ENGINEERING↗

In-line phase shift tomosynthesis

Purpose: The purpose of this work is to (1) demonstrate laboratory measurements of phase shift images derived from in-line phase-contrast radiographs using the attenuation-partition based algorithm (APBA) of Yan et al.[Opt. Express 18(15), 16074–16089 (2010)], (2) verify that the APBA reconstructed images obey the linearity principle, and (3) reconstruct tomosynthesis phase shift images from a collection of angularly sampled planar phase shift images.Methods: An unmodified, commercially available cabinet x-ray system (Faxitron LX-60) was used in this experiment. This system contains a tungsten anode x-ray tube with a nominal focal spot size of 10 μm. The digital detector uses CsI/CMOS with a pixel size of 50 × 50 μm. The phantoms used consisted of one acrylic plate, two polystyrene plates, and a habanero pepper. Tomosynthesis images were reconstructed from 51 images acquired over a ±25° arc. All phase shift images were reconstructed using the APBA.Results: Image contrast derived from the planar phase shift image of an acrylic plate of uniform thickness exceeded the contrast of the traditional attenuation image by an approximate factor of two. Comparison of the planar phase shift images from a single, uniform thickness polystyrene plate with two polystyrene plates demonstrated an approximate linearity of the estimated phase shift with plate thickness (−1600 rad vs −2970 rad). Tomographic phase shift images of the habanero pepper exhibited acceptable spatial resolution and contrast comparable to the corresponding attenuation image.Conclusions: This work demonstrated the feasibility of laboratory-based phase shift tomosynthesis and suggests that phase shift imaging could potentially provide a new imaging biomarker. Further investigation will be needed to determine if phase shift contrast will be able to provide new tissue contrast information or improved clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deterministic convergence in iterative phase shifting

Previous implementations of the iterative phase shifting method, in which the phase of a test object is computed from measurements using a phase shifting interferometer with unknown positions of the reference, do not provide an accurate way of knowing when convergence has been attained. We present a new approach to this method that allows us to deterministically identify convergence. The method is tested with a home-built Fizeau interferometer that measures optical surfaces polished to {lambda}/100 using the Hydra tool. The intrinsic quality of the measurements is better than 0.5 nm. Other possible applications for this technique include fringe projection or any problem where phase shifting is involved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase Shift Control of a Three-Phase Inverter for Balanced Secondary Currents in Misaligned Three-Phase Inductive Power Transfer Systems

This paper presents a strategy for generating fundamental reference voltage commands for a double-sided LCC tuned three-phase wireless power transfer (WPT) system to achieve balanced output currents when the receiver and transmitter are not perfectly aligned. Formulas for translating the normalized fundamental current commands into phase-shift commands for two of the phase legs in a two-level three-phase inverter are derived. The methodology is validated through circuit simulations performed using coupler models derived from finite-element simulations. Simulation results for a 1.5 k W system design are included, which indicate near perfect correction of imbalance in the secondary currents for a typical misalignment case.

Pries, Jason↗

Phase shifts and wave-packet displacements in neutron interferometry and a nondispersive, nondefocusing phase shifter

A phase shifter in neutron interferometry creates not only a phase shift but also a spatial displacement of the neutron wave packet, leading to a reduced interference contrast. This wave-packet displacement constitutes a major hindrance in measuring large phase shifts. Here we present a nondispersive configuration with two identical phase shifters placed on one path in successive gaps of a symmetric triple Laue (LLL) interferometer. As compared to a single phase shifter, the dual phase shifter generates double the phase shift, yet a net null displacement of the wave packet. The interferometer thus remains fully focused however large the phase shift or the incident wavelength spread, permitting a white incident neutron beam as in the case of a purely topological phase measurement. Misalignment angles of a monolithic nondispersive dual phase shifter are equal and opposite in the two gaps. Its phase therefore remains nondispersive over a much wider angular range and attains a minimum magnitude at the correct orientation, obviating the need to alternate the phase shifter between the two interferometer paths during its alignment. The setup is hence ideally suited for measuring neutron coherent scattering lengths to ultrahigh precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coma measurement by use of an alternating phase-shifting mask mark with a specific phase width

The correlation between the coma sensitivity of the alternating phase-shifting mask (Alt-PSM) mark and the mark's structure is studied based on the Hopkins theory of partially coherent imaging and positive resist optical lithography (PROLITH) simulation. It is found that an optimized Alt-PSM mark with its phase width being two-thirds its pitch has a higher sensitivity to coma than Alt-PSM marks with the same pitch and the different phase widths. The pitch of the Alt-PSM mark is also optimized by PROLITH simulation, and the structure of p=1.92{lambda}/NA and pw=2p/3 proves to be with the highest sensitivity. The optimized Alt-PSM mark is used as a measurement mark to retrieve coma aberration from the projection optics in lithographic tools. In comparison with an ordinary Alt-PSM mark with its phase width being a half its pitch, the measurement accuracies of Z7 and Z14 apparently increase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and numerical investigations of the phase-shift effect in capacitively coupled discharges

The phase-shift effect has been investigated by a Langmuir probe and a fluid model in Ar capacitively coupled plasmas at 50 mTorr. In the discharge, two sources with the same frequency, i.e., 27.12 MHz, are applied on the top and bottom electrodes simultaneously, and the phase shift between them varies from 0 to π. It is found that the electron density has an off-axis peak near the radial edge when the phase difference is equal to 0 due to the electrostatic edge effect, and the best radial uniformity is observed at a phase difference equal to π. Furthermore, when the voltage increases, the best radial uniformity is obtained at lower phase shift values. Moreover, the electron energy probability function has a bi-temperature structure at all the selected phase differences at r = 1–15 cm. The evolution of the plasma characteristics with the phase difference implies that the best radial uniformity can be obtained, by balancing the electrostatic edge effect and the phase shift effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lattice determination of 𝐼=0 and 2 𝜋⁢𝜋 scattering phase shifts with a physical pion mass

Phase shifts for 𝑠-wave 𝜋⁢𝜋 scattering in both the 𝐼 =0 and 𝐼 =2 channels are determined from a lattice QCD calculation performed on 741 gauge configurations obeying G-parity boundary conditions with a physical pion mass and lattice size of 32 3 ×64. These results support our recent 2021 study of direct 𝐶⁢𝑃 violation in 𝐾 → 𝜋⁢𝜋 decay, improving our earlier 2015 calculation. The phase shifts are determined for both stationary and moving 𝜋⁢𝜋 systems, at three (𝐼 = 0) and four (𝐼 = 2) different total momenta. We implement several 𝜋⁢𝜋 interpolating operators including a scalar bilinear “𝜎” operator and paired single-pion bilinear operators with the constituent pions carrying various relative momenta. Several techniques, including correlated fitting and a bootstrap determination of p-values have been used to refine the results and a comparison with the generalized eigenvalue problem method is given. A detailed systematic error analysis is performed which allows phase shift results to be presented at a fixed energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Regenerative Phase Shift and its Effect on Coherent Laser Arrays

A coherent array of regenerative amplifiers in an external cavity with a rank 1 scattering matrix is described and analyzed. Using a resonant cavity analysis, it is shown how the addition of regenerative feedback to each element in the array creates a phase shift relative to the well-known 'cold-cavity phase shift'. This phase shift is quantified and found to significantly affect the phasing properties of coherent arrays, even in the absence of the nonlinear Kerr effect and the gain-dependent phase shift. In particular, this regenerative phase shift is shown to concentrate the distribution of phases at the output of the laser array into a narrower phase range compared to the random distribution expected using a nonregenerative amplifier in the presence of effectively random cold-cavity phase shifts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect on plasma and etch-rate uniformity of controlled phase shift between rf voltages applied to powered electrodes in a triode capacitively coupled plasma reactor

The influence of the phase shift between rf voltages applied to the powered electrodes on plasma parameters and etch characteristics was studied in a very high-frequency (VHF) capacitively coupled plasma (CCP) triode reactor. rf voltages at 100 MHz were simultaneously applied to the top and bottom electrodes having a controlled phase shift between them, which could be varied between 0 deg. and 360 deg. Several plasma and process characteristics were measured as a function of the phase shift: (i) radial profiles of plasma-emission intensity, (ii) line-of-sight averaged plasma-emission intensity, and (iii) radial profiles of blanket SiO{sub 2} etching rate over a 300 mm wafer. Radial profiles of plasma emission were obtained using the scanning optical probe. It has been shown that all the measured characteristics strongly depend on the phase shift: (i) plasma-emission intensity is minimal at phase shift equal to 0 deg. and maximal at 180 deg. for all radial positions, while the emission radial profile changes from bell-shaped distribution with considerable nonuniformity at 0 deg. to a much more flattened distribution at 180 deg.; (ii) line-of-sight averaged plasma-emission intensity shows a similar dependence on the phase shift with minimum and maximum at 0 deg. and 180 deg., respectively; and (iii) the etch-rate radial profile at 180 deg. shows a much better uniformity as compared to that at 0 deg. Some of these results can be qualitatively explained by the redistribution of plasma currents that flow between the electrodes and also from the electrodes to the grounded wall with the phase shift. We suggest that the phase-shift effect can be used to improve the plasma and etch-rate spatial uniformity in VHF-CCP triode reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase shift multiplication effect of all-optical analog to electromagnetically induced transparency in two micro-cavities side coupled to a waveguide system

We propose phase shift multiplication effect of all-optical analog to electromagnetically induced transparency in two photonic crystal micro-cavities side coupled to a waveguide system through external optical pump beams. With dynamically tuning the propagation phase of the line waveguide, the phase shift of the transmission spectrum in two micro-cavities side coupled to a waveguide system is doubled along with the phase shift of the line waveguide. π-phase shift and 2π-phase shift of the transmission spectrum are obtained when the propagation phase of the line waveguide is tuned to 0.5π-phase shift and π-phase shift, respectively. All observed schemes are analyzed rigorously through finite-difference time-domain simulations and the coupled-mode formalism. These results show a new direction to the miniaturization and the low power consumption of microstructure integration photonic devices in optical communication and quantum information processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of error-compensating algorithms for sinusoidal phase shifting interferometry

An improved approach to interferometry using sinusoidal phase shifting balances several harmonic components in the interference signal against each other. The resulting computationally efficient phase-estimation algorithms have low sensitivity to errors such as spurious intensity noise, vibration, and errors in the phase shift pattern. Specific example algorithms employing 8 and 12 camera frames illustrate design principles that are extendable to algorithms of any length for applications that would benefit from a simplified, sinusoidal phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppressing phase errors from vibration in phase-shifting interferometry

A general method for reducing the influence of vibrations in phase-shifting interferometry corrects the surface phase map through a spectral analysis of a ''phase-error pattern,'' a plot of the interference intensity versus the measured phase, for each phase-shifted image. The method is computationally fast, applicable to any phase-shifting algorithm and interferometer geometry, has few restrictions on surface shape, and unlike spatial Fourier methods, high density spatial carrier fringes are not required, although at least a fringe of phase departure is recommended. Over a 100x reduction in vibrationally induced surface distortion is achieved for small amplitude vibrations on real data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. Here, we directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Xu, Yaoyao [Huazhong Univ. of Science and Technolo↗

The I=2 ππ S-wave Scattering Phase Shift from Lattice QCD

The π + π + s-wave scattering phase-shift is determined below the inelastic threshold using Lattice QCD. Calculations were performed at a pion mass of m π ≈ 390 MeV with an anisotropic n f = 2+1 clover fermion discretization in four lattice volumes, with spatial extent L ≈ 2.0, 2.5, 3.0 and 3.9 fm, and with a lattice spacing of b s ≈ 0.123 fm in the spatial direction and b t b s /3.5 in the time direction. The phase-shift is determined from the energy-eigenvalues of π + π + systems with both zero and non-zero total momentum in the lattice volume using Luscher's method. Our calculations are precise enough to allow for a determination of the threshold scattering parameters, the scattering length a, the effective range r, and the shape-parameter P, in this channel and to examine the prediction of two-flavor chiral perturbation theory: m π 2 a r = 3+O(m π 2 /Λ χ 2 ). Chiral perturbation theory is used, with the Lattice QCD results as input, to predict the scattering phase-shift (and threshold parameters) at the physical pion mass. Our results are consistent with determinations from the Roy equations and with the existing experimental phase shift data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the surface profile of a curved optical surface with rotation phase-shifting lateral shear cyclic path optical configuration

We present a new (to our knowledge) technique for introducing phase shifts between the laterally sheared emergent beam components of a cyclic path optical configuration (CPOC). The phase shifts are introduced by applying a small change in the angle of incidence of the incident beam due to the small angular rotation of the CPOC setup. Phase-shifting interferometry has been applied along with this phase-shifting technique for a CPOC with lateral shear to find the surface slope/profile of curved optical surfaces. Results for a spherical optical surface have been discussed. An optical setup for measurement of the surface profile of toroidal beam line mirrors of synchrotron radiation sources is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the phase shift between electric potential and plasma density fluctuations in the edge turbulence

In some cases, the phase shift between fluctuations of the electric potential and plasma density helps to identify the instability that governs the turbulent state. In this paper, the basic experimental and theoretical results that denote the possibility (or impossibility) of such identification are briefly discussed. The experimental data based on measurements of the phase shift between the floating potential and ion saturation current fluctuations in the L-2M stellarator-a system with externally imposed magnetic surfaces-are presented (Shchepetov, Kholnov, Fedyanin, et al., Plasma Phys. Controlled Fusion 50, 045001 (2008)). It is shown that the observed phase shift {Omega} varies in a wide range from {pi} to 0, gradually decreasing with deepening inside the plasma. A number of arguments are presented suggesting that {Omega} Almost-Equal-To {pi} can indicate that the process is nonlocal, i.e., oscillations at a given spatial point are driven and mainly determined by the processes localized outside of the observation point. We note that, within the framework of the magnetohydrodynamic theory, plasma was definitely unstable with respect to resistive interchange modes in all cases under study. It is demonstrated experimentally that the widespread notion that the phase shift {Omega} Almost-Equal-To {pi}/2 is characteristic of only resistive interchange modes is hardly universal. The experimental results are analyzed on the basis of analytical estimates.