Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photodiode arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

Measurement of near- and far-field impurity flows during pellet-induced rapid shutdown in DIII-D

Both near-field (<1 m away toroidally from the pellet) and far-field (>1 m away toroidally from the pellet) poloidal and toroidal impurity (carbon ion) flows are measured using visible imaging and fast bolometry during a polypropylene pellet-induced rapid plasma shutdown in the DIII-D tokamak. In the near field, the pellet appears to increase poloidal flow in the ion diamagnetic direction, possibly due to the strong radial temperature gradient caused by the pellet ablation. In the far field, the poloidal impurity flow typically appears slower and in the opposite direction. Toroidal impurity flow appears to be strongly influenced by the plasma initial toroidal rotation, especially in the far field. These results demonstrate that rapid shutdown impurity flows are not necessarily global in structure but can be quite different close to and far from the injected pellet.

Electromagnetic radiation detectors↗

Modular low cost trackerless spectral sensor

A non-tracking solar sensor device and systems. The non-tracking solar sensor system includes a transparent hemispherical dome enclosure for receiving light. A diffuser is disposed with the enclosure for diffusing the light. A photodiode sensor array senses at least one discrete wavelength of the diffused light. A data acquisition module is configured to receive a sensor signal from the sensor array, the signal indicative of light quality at least one discrete wave band for processing via a processor module.

Armijo, Kenneth M.↗

Photovoltaic array for a power-by-light system

A hybrid-integrated series/parallel-connected photovoltaic diode array employs 10s-to-100s of single-wavelength III-V compound semiconductor photodiodes in an array bonded onto a transparent optical plate through which the array is illuminated by monochromatic light. The power-by-light system receiver enables high-voltage, up to 1000s of volts, optical transmission of power to remote electrical systems in harsh environments.

Vawter, Gregory A.↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-throughput feedback-enabled optogenetic stimulation and spectroscopy in microwell plates

Abstract The ability to perform sophisticated, high-throughput optogenetic experiments has been greatly enhanced by recent open-source illumination devices that allow independent programming of light patterns in single wells of microwell plates. However, there is currently a lack of instrumentation to monitor such experiments in real time, necessitating repeated transfers of the samples to stand-alone analytical instruments, thus limiting the types of experiments that could be performed. Here we address this gap with the development of the optoPlateReader (oPR), an open-source, solid-state, compact device that allows automated optogenetic stimulation and spectroscopy in each well of a 96-well plate. The oPR integrates an optoPlate illumination module with a module called the optoReader, an array of 96 photodiodes and LEDs that allows 96 parallel light measurements. The oPR was optimized for stimulation with blue light and for measurements of optical density and fluorescence. After calibration of all device components, we used the oPR to measure growth and to induce and measure fluorescent protein expression in E. coli . We further demonstrated how the optical read/write capabilities of the oPR permit computer-in-the-loop feedback control, where the current state of the sample can be used to adjust the optical stimulation parameters of the sample according to pre-defined feedback algorithms. The oPR will thus help realize an untapped potential for optogenetic experiments by enabling automated reading, writing, and feedback in microwell plates through open-source hardware that is accessible, customizable, and inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗

Gas puff imaging on the TCV tokamak

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

p-i-n High-Speed Photodiodes for X-RAY and Infrared Imagers Fabricated by In-Situ -Doped APCVD Germanium Homoepitaxy

Design, simulation, fabrication, and measurement have been performed using a new method for obtaining high-speed p-i-n germanium photodiodes for use in backside imaging arrays. These devices are proof-of-principal in situ-doped vertical mesa structures fabricated using single-wafer, atmospheric-pressure chemical vapor deposition (APCVD) homoepitaxy on Czochralski-grown Ge substrates. Excellent impurity profiles resulting from in situ doping, as measured by spreading-resistance profilometry, were 5 × 10 16 , 2 × 10 15 , and 2 × 10 18 (cm -3 ) for the p-type anode, i-region absorber, and n+ cathode, respectively. Scanning electron microscopy analysis revealed very-low defect densities in the epitaxial layers. The diodes, with diameters ranging 100-500 μm, exhibited excellent ideality (n = 1.15) and less than 1-μA dark current, corresponding to up to 80 kV-cm -1 electric field in the smallest devices. Avalanche breakdown bias was consistently at a magnitude of 50 V or lower. External quantum efficiencies in the near-infrared spectrum peaked at 70%. Pulsed illumination experiments, both in the infrared and X-ray regions, showed pulse rise times in the 100-140 ps range, indicating excellent applicability of this method to high-speed X-ray or infrared applications.

36 MATERIALS SCIENCE↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

2D microspatial distribution uniformity of photon detection efficiency and crosstalk probability of multi-pixel photon counters

Two-dimensional (2D) microspatial distribution uniformity of photon detection efficiency (PDE) and optical crosstalk probability P{sub ct} of multi-pixel photon counters (MPPCs) is studied. The experimental results show that the 2D spatial distribution of P{sub ct} is obviously uneven, i.e. P{sub ct} is larger at the corners and edges of a single pixel in MPPCs, which suggest a higher electrical field in the depletion region of the pixel at the corners and edges. The nonuniformity of the 2D spatial distribution of PDE also become evident when the size of the pixels of MPPCs is small, which signifies higher nonuniformity of the electric field distribution in MPPCs with small pixel size. A method is proposed for characterization of the 2D electrical field spatial distribution uniformity in a single pixel of MPPCs, which can be used for guiding the optimisation of the fabrication process of MPPCs and their properties. This promising method can naturally be extended to any Geiger avalanche photodiodes (G-APDs) and their arrays. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward ultrafast, ultra-stable imaging arrays: Superlattice doping to enhance the performance of backside-illuminated 3D-hybridized silicon photodetectors

In this paper, the authors report the latest results on their development of superlattice-doped, thinned, backside-illuminated (BSI), 3D-integrated photodiode detectors—a step toward their ultimate goal of demonstrating ultrafast, ultrastable CMOS imaging arrays. As with most silicon-based photodetectors, backside-illumination and backside surface passivation are keys to achieve the highest performance capability. The two-dimensional (2D) doping technique developed at the Jet Propulsion Laboratory (JPL) has proved to result in a highly efficient, highly stable detector response when combined with a variety of detectors. Here, JPL's 2D-doping has been combined with Sandia's BSI photodetectors hybridized with custom fanout wafer via copper Direct Bond Interconnect (DBI®), a technology that is rapidly becoming industry standard for BSI CMOS imaging arrays. The prototype detectors were packaged and evaluated with respect to their response to low energy electrons. The authors find that the responsivity of 2D-doped BSI detectors is higher than devices prepared using other surface passivation techniques (i.e., ion implantation). The success of the work described herein verifies that the 2D-doping processes previously developed for Sandia's frontside-illuminated photodetectors are generally applicable to BSI detectors and demonstrates for the first time that JPL's 2D-doping process is compatible with the Cu-DBI® technology.

Jewell, April D.↗

Geranium Photodiodes for Hard Xray Detection

This report summarizes the investigations engaged at UC Davis under subcontract B632083, as related to the LLNL-LDRD Project “High-Speed X-Ray Imager Arrays.” The first section entails work done within the Electrical and Computer Engineering (ECE) Department. The purpose of the work done so far is to understand photodiode design and which parameters are conducive to the design goals, which are: I: Maximize the detector quantum efficiency. The device must have a quantum efficiency of roughly 5% at 80 keV. II: Minimize temporal response. Collection time is limited to 1ns. All charge must be collected in that time. III: Minimize dark current. In this document, various photodiode parameters and designs are explored, and their impact on these goals are tabulated. In addition to these, various instruments that have been constructed for either testing these parameters or helping teammates with their experiments. The second section entails work done with the Materials Science Engineering (MSE) Department. In accordance with the proposed development of the germanium ROIC backside imagers, a critical step in the micromachining of these devices was the removal of the substrate on which the PIN junctions were epitaxially grown. A common technique for the micromachining of silicon wafers is the use of chemical etching alongside an “etch-stop” layer. In this technique, a chemical etchant will remove material until it reaches the etch-stop layer, at which the etch rate will drop significantly. This high selectivity (ratio of etch rates) allows any unevenness in the initial etching to be effectively smoothed away in the event that part of the wafer surface reaches the etch-stop layer sooner than another. An initial literature review found a paper by Divan et al. in which the authors used ion implantation to dope germanium wafers and achieve selectivity on the order of 100, sufficient for a reliable etch-stop.

42 ENGINEERING↗

Femtojoule optical nonlinearity for deep learning with incoherent illumination

Optical neural networks (ONNs) are a promising computational alternative for deep learning due to their inherent massive parallelism for linear operations. However, the development of energy-efficient and highly parallel optical nonlinearities, a critical component in ONNs, remains an outstanding challenge. Here, we introduce a nonlinear optical microdevice array (NOMA) compatible with incoherent illumination by integrating the liquid crystal cell with silicon photodiodes at the single-pixel level. We fabricate NOMA with more than half a million pixels, each functioning as an optical analog of the rectified linear unit at ultralow switching energy down to 100 femtojoules per pixel. With NOMA, we demonstrate an optical multilayer neural network. Our work holds promise for large-scale and low-power deep ONNs, computer vision, and real-time optical image processing.

36 MATERIALS SCIENCE↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QTIA, a 2.5 or 10 Gbps 4-channel array optical receiver ASIC in a 65 nm CMOS technology

Here, the Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗