Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photometric Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Astronomical Test of CCD Photometric Precision

This article considers a posteriori error estimation of specified functionals for first-order systems of conservation laws discretized using the discontinuous Galerkin (DG) finite element method. Using duality techniques. we derive exact error representation formulas for both linear and nonlinear functionals given an associated bilinear or nonlinear variational form. Weighted residual approximations of the exact error representation formula are then proposed and numerically evaluated for Ringleb flow, an exact solution of the 2-D Euler equations.

Koch, David↗

CALiPER Exploratory Study: Recessed Troffer Lighting

This report describes an exploration of troffer lighting as used in office and classroom spaces, which was conducted by the CALiPER program. Twenty-four pairs of 2×2 and 2×4 troffers were procured anonymously, documented, tested for photometric and electrical performance, and installed in a mockup office space in Portland, Oregon. Three of the pairs were T8 fluorescent benchmark products, 12 were dedicated LED troffers, five were fluorescent troffers modified for LED lamps (sometimes referred to as "tubes"), and another four troffers were modified with LED retrofit kits. The modifications were performed by a commercial electrical contractor, following the instructions provided by the retrofit lamp or kit manufacturer. Once installed in the mockup facility, the converted luminaires were examined by a NRTL (Nationally Recognized Testing Laboratory) safety expert, who provided feedback on safety issues. In September 2012, a group of lighting designers, engineers, and facility managers were brought in to observe the LED luminaires in comparison to fluorescent benchmarks. This report documents performance in measures that go beyond illuminance values or luminaire efficacy. Dedicated LED troffers are ready to compete with fluorescent troffers in terms of efficacy (lumens per watt), and in many lighting quality issues such as glare, light distribution, visual appearance, and color quality. That is not to say that each one is stellar, but each one tested in this CALiPER study bested the fluorescent benchmarks in terms of efficacy, and almost all were rated highly in several categories -- only one luminaire of twelve performed consistently poorly.

CALiPER Program↗

A Blind Test of Hapke's Photometric Model

Hapke's bidirectional reflectance equation is a versatile analytical tool for predicting (i.e. forward modeling) the photometric behavior of a particulate surface from the observed optical and structural properties of its constituents. Remote sensing applications of Hapke s model, however, generally seek to predict the optical and structural properties of particulate soil constituents from the observed photometric behavior of a planetary surface (i.e. inverse-modeling). Our confidence in the latter approach can be established only if we ruthlessly test and optimize it. Here, we summarize preliminary results from a blind-test of the Hapke model using laboratory measurements obtained with the Bloomsburg University Goniometer (B.U.G.). The first author selected eleven well-characterized powder samples and measured the spectrophotometric behavior of each. A subset of twenty undisclosed examples of the photometric measurement sets were sent to the second author who fit the data using the Hapke model and attempted to interpret their optical and mechanical properties from photometry alone.

Helfenstein, P.↗

The HectoMAP Redshift Survey: First Data Release

HectoMAP is a dense, red-selected redshift survey to a limiting r = 21.3 mag covering 55 deg 2 in a contiguous 1fdg5 strip across the northern sky. This region is also covered by the Subaru/Hyper Suprime-Cam (HSC) Subaru Strategic Program photometric survey enabling a range of applications that combine a dense foreground redshift survey with both strong and weak lensing maps. The median redshift of HectoMAP exceeds 0.3 throughout the survey region, and the mean density of the redshift survey is ~2000 galaxies deg -2 . Here we report a total of 17,313 redshifts in a first data release covering 8.7 deg 2 . Additionally, we include the derived quantities D n 4000 and stellar mass for nearly all of the objects. Among these galaxies, 8117 constitute a 79% complete red-selected subsample with r ≤ 20.5 mag, and an additional 4318 constitute a 68% complete red-selected subsample with 20.5 < r(mag) < 21.3. As examples of the strengths of HectoMAP data, we discuss two applications: refined membership of redMaPPer photometrically selected clusters and a test of HSC photometric redshifts. We highlight a remarkable redMaPPer strong lensing system. The comparison of photometric redshifts with spectroscopic redshifts in a dense survey uncovers subtle systematic issues in the photometric redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Photometric Signature of Ultraharmonic Resonances in Barred Galaxies

Bars may induce morphological features, such as rings, through their resonances. Previous studies suggested that the presence of "dark gaps," or regions of a galaxy where the difference between the surface brightness along the bar major axis and that along the bar minor axis is maximal, can be attributed to the location of bar corotation. Here, using GALAKOS, a high-resolution N-body simulation of a barred galaxy, we test this photometric method's ability to identify the bar corotation resonance. Contrary to previous work, our results indicate that "dark gaps" are a clear sign of the location of the 4:1 ultraharmonic resonance instead of bar corotation. Measurements of the bar corotation can indirectly be inferred using kinematic information, e.g., by measuring the shape of the rotation curve. We demonstrate our concept on a sample of 578 face-on barred galaxies with both imaging and integral field observations and find that the sample likely consists primarily of fast bars.

79 ASTRONOMY AND ASTROPHYSICS↗

Initial Results from the Bloomsburg University Goniometer Laboratory

The Bloomsburg University Goniometer Laboratory (B.U.G. Lab) consists of three systems for studying the photometric properties of samples. The primary system is an automated goniometer capable of measuring the entire bi-directional reflectance distribution function (BRDF) of samples. Secondary systems include a reflectance spectrometer and digital video camera with macro zoom lens for characterizing and documenting other physical properties of measured samples. Works completed or in progress include the characterization of the BRDF of calibration surfaces for the 2003 Mars Exploration Rovers (MER03), Martian analog soils including JSC-Mars-1, and tests of photometric models.

Shepard, M. K.↗

Characterizing Photometric Flicker

The focus of this study is simply to report on the commercial availability and performance of emerging flicker meters. Commercial-meter measurements and calculations were compared against those generated by a photoelectric characterization system developed by the Pacific Northwest National Laboratory (PNNL). The results and analysis show that the three commercially available flicker meters evaluated for this study measured light-intensity waveforms and calculated essential flicker-performance characteristics and metrics similarly, both to each other and to the reference meter chosen as an accuracy benchmark. Some differences in performance were found, however, when measurements were taken of light-intensity waveforms with significant high-frequency content – greater than the dominant 120 Hz found in many products at full output. Such conditions may be found in light sources that employ pulse-width modulation to achieve their target light output (e.g., intensity or color). If the meter was not appropriately configured (e.g., sampling frequency was too low), or if proper configuration was not possible given meter constraints (e.g., maximum number of available data points), then the waveform characteristics were not accurately captured, often resulting in the calculation of flicker metrics that deviated significantly from the reference.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WIYN Open Cluster Study. LXXV. Testing the Metallicity Dependence of Stellar Lithium Depletion Using Hyades-aged Clusters. I. Hyades and Praesepe

WIYN/Hydra spectroscopy (at R ∼ 15,000) of the moderately metal-rich Praesepe and Hyades open clusters was used to study their main-sequence (MS) iron ([Fe/H]) and lithium (A(Li)) abundances. Self-consistent [Fe/H] and Li analyses of these clusters of consistent age, which we re-evaluate, confirms that they have consistent [Fe/H] and provides a foundation to investigate the poorly understood G-dwarf and F-dwarf Li-depletions. Neither phenomenon agrees with standard stellar evolution theory, but possible explanations abound. We supplement our A(Li) with previously published results placed on a uniform abundance scale. This creates the largest self-consistently analyzed sample of A(Li) in both the Hyades (90) and Praesepe (110). For each star, high-precision UBVRI photometry was used to determine a 10-color-based T{sub eff} and then to test for photometric peculiarities indicated by a large σ{sub Teff} (>75 K). The stars that have large σ{sub Teff} were predominantly found to be binaries or stars with peculiar (apparent) A(Li). When considering only proper-motion members that have low σ{sub Teff} and are also photometrically consistent with the cluster MS fiducial, each cluster has a more tightly defined Li morphology than previously observed and the two clusters’ A(Li) are indistinguishable. This suggests that clusters of consistent age and metallicity may have consistent Li-depletion trends across a broad range of T{sub eff}; no additional major parameters are required, at least for these two clusters. We propose that the combined Hyades and Praesepe data offer more rigorous constraints than does either cluster alone, and we discuss newly revealed features of the combined Li–T{sub eff} trend.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing the Presence of Multiple Photometric Components in Nearby Early-type Galaxies Using SDSS

We investigate two-dimensional image decomposition of nearby, morphologically selected early-type galaxies (ETGs). We are motivated by recent observational evidence of significant size growth of quiescent galaxies and theoretical development advocating a two-phase formation scenario for ETGs. We find that a significant fraction of nearby ETGs show changes in isophotal shape that require multi-component models. The characteristic sizes of the inner and outer component are ∼3 and ∼15 kpc. The inner component lies on the mass–size relation of ETGs at z ∼ 0.25–0.75, while the outer component tends to be more elliptical and hints at a stochastic buildup process. We find real physical differences between single- and double-component ETGs, with double-component galaxies being younger and more metal-rich. The fraction of double-component ETGs increases with increasing σ and decreases in denser environments. We hypothesize that double-component systems were able to accrete gas and small galaxies until later times, boosting their central densities, building up their outer parts, and lowering their typical central ages. In contrast, the oldest galaxies, perhaps due to residing in richer environments, have no remaining hints of their last accretion episode.

79 ASTRONOMY AND ASTROPHYSICS↗

Viking magnetic properties investigation - Preliminary results

Three permanent-magnet arrays are aboard the Viking lander. By sol 35, one array, fixed on a photometric reference test chart on top of the lander, has clearly attracted magnetic particles from airborne dust; two other magnet arrays, one strong and one weak, incorporated in the backhoe of the surface sampler, have both extracted considerable magnetic mineral from the surface as a result of nine insertions associated with sample acquisition. The loose Martian surface material around the landing site is judged to contain 3 to 7 per cent highly magnetic mineral which, pending spectrophotometric study, is thought to be mainly magnetite.

Hargraves, R. B.↗

The Viking magnetic properties experiment - Primary mission results

Three permanent magnet arrays were mounted on each Viking lander: a strong array fixed on a photometric reference test chart on top of the landers; and two arrays, one strong and one weak, incorporated into the backhoe of the surface sampler. Some or all of the magnetic particles detected could be highly magnetic unoxidized mineral grains (metallic Fe, magnetite, pyrrhotite) forming the core beneath a reddish coating of limonite or hematite; or grains composed of gamma-Fe2O3, with and without other iron oxides; or igneous rock (or mineral particles) which consist of an admixture of unweathered silicate material or minerals with a significant fraction of highly magnetic phase, again with a reddish coating; they could be also igneous rock or mineral particles, intrinsically nonmagnetic, but having a reddish coating containing gamma-Fe2O3; or clay mineral particles which contain and/or are coated with Fe2O3, of which a substantial fraction is in the gamma-Fe2O3 form.

Hargraves, R. B.↗

Test and model correlation of the atmospheric emission photometric imager fiberglass pedestal

The correlation is presented of the static loads testing and finite element modeling for the fiberglass pedestal used on the Atmospheric Emission Photometric Imaging (AEPI) experiment. This payload is to be launched in the space shuttle as part of the ATLAS-1 experiment. Strain gauge data from rosettes around the highly loaded base are compared to the same load case run for the Spacelab 1 testing done in 1981. Correlation of the model and test data was accomplished through comparison of the composite stress invariant using the expected flight loads for the ATLAS-1 mission. Where appropriate, the Tsai-Wu failure criteria was used in the development of the key margins of safety. Margins of safety are all positive for the pedestal and are reported.

Lee, H. M., III↗

Comparison of Hapke's photometric theory with Voyager observations of Europa, Enceladus, Rhea and Mimas

Voyager imaging observations of the satellites of Jupiter and Saturn provide an excellent test for various photometric theories that were proposed to describe the scattering properties of planetary and satellite surfaces. Not only does the Voyager data set include observations of surfaces ranging widely in albedo, but it provides measurements (in both disc-integrated and disc-resolved forms) over a wide range of phase angles. A detailed comparison of the above models with Voyager data for Europa, Enceladus, Rhea, and Mimas was described. These satellites were selected because they cover a range of reflectances from 0.65 to 1.0 and because for them the Voyager photometric data sets are most complete.

Buratti, B.↗

Light-emitting device test systems

Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.

36 MATERIALS SCIENCE↗

End-to-End System Test of the Relative Precision and Stability of the Photometric Method for Detecting Earth-Size Extrasolar Planets

We developed the CCD camera system for the laboratory test demonstration and designed the optical system for this test. The camera system was delivered to Ames in April, 1999 with continuing support mostly in the software area as the test progressed. The camera system has been operating successfully since delivery. The optical system performed well during the test. The laboratory demonstration activity is now nearly complete and is considered to be successful by the Technical Advisory Group, which met on 8 February, 2000 at the SETI Institute. A final report for the Technical Advisory Group and NASA Headquarters will be produced in the next few months. This report will be a comprehensive report on all facets of the test including those covered under this grant. A copy will be forwarded, if desired, when it is complete.

Dunham, Edward W.↗

Wavefront-error evaluation by mathematical analysis of experimental Foucault-test data

The diffraction theory of the Foucault test provides an integral formula expressing the complex amplitude and irradiance distribution in the Foucault pattern of a test mirror (lens) as a function of wavefront error. Recent literature presents methods of inverting this formula to express wavefront error in terms of irradiance in the Foucault pattern. The present paper describes a study in which the inversion formulation was applied to photometric Foucault-test measurements on a nearly diffraction-limited mirror to determine wavefront errors for direct comparison with ones determined from scatter-plate interferometer measurements. The results affirm the practicability of the Foucault test for quantitative wavefront analysis of very small errors, and they reveal the fallacy of the prevalent belief that the test is limited to qualitative use only. Implications of the results with regard to optical testing and the potential use of the Foucault test for wavefront analysis in orbital space telescopes are discussed.

Wilson, R. G.↗

Performance testing of the high altitude observatory PDS microdensitometer

High Altitude Observatory HAO microdensitometer undergoes monthly testing to assure its consistent performance. These tests check positional and photometric stability at the 10 micron aperture level. The HAO test procedure is designed to run without operator intervention following initial configuration of the microdensitometer for each subprocedure. Specialized test software is resident in the PDP 8. The operator selects the proper subprocedure by entering commands. Once computer control is established, it is not relinquished until the test is complete.

Poland, A.↗