Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photovoltaic array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Application of Structural Reliability Techniques to Plume Impingement Loading of the Space Station Freedom Photovoltaic Array

A new aerospace application of structural reliability techniques is presented, where the applied forces depend on many probabilistic variables. This application is the plume impingement loading of the Space Station Freedom Photovoltaic Arrays. When the space shuttle berths with Space Station Freedom it must brake and maneuver towards the berthing point using its primary jets. The jet exhaust, or plume, may cause high loads on the photovoltaic arrays. The many parameters governing this problem are highly uncertain and random. An approach, using techniques from structural reliability, as opposed to the accepted deterministic methods, is presented which assesses the probability of failure of the array mast due to plume impingement loading. A Monte Carlo simulation of the berthing approach is used to determine the probability distribution of the loading. A probability distribution is also determined for the strength of the array. Structural reliability techniques are then used to assess the array mast design. These techniques are found to be superior to the standard deterministic dynamic transient analysis, for this class of problem. The results show that the probability of failure of the current array mast design, during its 15 year life, is minute.

Yunis, Isam S.↗

Consideration of encapsulants for photovoltaic arrays in terrestrial applications

Long-term survivability of photovoltaic arrays and components in terrestrial environments will require development of adequate protective systems. Highly considered are polymeric encapsulants, a method which was successfully employed in space and aerospace applications to protect critical electrical circuitry. To be employable, however, the polymer encapsulants must themselves be chemically and mechanically resistant to failure in terrestrial service. Chemical resistance includes stability to the degrading actions of ultraviolet light, oxygen, moisture and elevated temperatures in sun rich areas. Programs are underway to identify and develop chemically stable encapsulant candidates. Chemical considerations aside, mechanical failures of the encapsulants must also be avoided in array designs. This paper discusses design considerations for avoiding mechanical failures of polymeric encapsulants, with emphasis on biaxial properties, thermal fatigue, and anisotropy and nonhomogeneity of material properties. The general principles to be presented evolved from actual failures of polymeric materials in engineering applications. Also included are brief remarks on the permeability of polymer materials to atmospheric gases.

Cuddihy, E. F.↗

The Photovoltaic Array Space Power plus Diagnostics (PASP Plus) Flight Experiment

An overview of the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) flight experiment is presented in outline and graphic form. The goal of the experiment is to test a variety of photovoltaic cell and array technologies under various space environmental conditions. Experiment objectives, flight hardware, experiment control and diagnostic instrumentation, and illuminated thermal vacuum testing are addressed.

Piszczor, Michael F.↗

Atomic oxygen durability evaluation of the flexible batten for the photovoltaic array mast on Space Station

A test program was conducted at the National Aeronautics and Space Administration's Lewis Research Center (LeRC) to evaluate the long term low Earth orbital (LEO) atomic oxygen (AO) durability of a flexible (fiberglass-epoxy composite) batten. The flexible batten is a component used to provide structural rigidity in the photovoltaic array mast on Space Station. The mast is used to support and articulate the photovoltaic array, therefore, the flexible batten must be preloaded for the 15 year lifetime of an array blanket. Development hardware and composite materials were evaluated in ground testing facilities for AO durability and dynamic retraction-deployment cyclic loading representative of expected full life in-space application. The CV1144 silicone (AO protective) coating was determined to provide adequate protection against AO degradation of the composite material and provided fiber containment, thus the structural integrity of the flexible batten was maintained. Both silicone coated and uncoated flexible battens maintained load carrying capabilities. Results of the testing did indicate that the CV1144 silicone protective coating was oxidized by AO reactions to form a brittle glassy (SiO2) skin that formed cracking patterns on all sides of the coated samples. The cracking was observed in samples that were mechanically stressed as well as samples in non-stressed conditions. The oxidized silicon was observed to randomly spall in small localized areas, on the flexible battens that underwent retraction-deployment cycling. Some darkening of the silicon, attributed to vacuum ultraviolet (VUV) radiation, was observed.

Stidham, Curtis R.↗

Photovoltaic array space power plus diagnostics experiment

The objective of the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) experiment is to measure the effects of the interaction of the low- to mid-altitude space environment on the performance of a diverse set of small solar-cell arrays (planar and concentrator, representative of present and future military technologies) under differing conditions of velocity-vector orientation and simulated (by biasing) high-voltage operation. Solar arrays to be tested include Si and GaAs planar arrays and several types of GaAs concentrator arrays. Diagnostics (a Langmuir probe and a pressure gauge) and a transient pulse monitor (to measure radiated and conducted EMI during arcing) will be used to determine the impact of the environment on array operation to help verify various interactions models. Results from a successful PASP Plus flight will furnish answers to important interactions questions and provide inputs for design and test standards for photovoltaic space-power subsystems.

Guidice, Donald A.↗

Electrical Performance of the International Space Station U.S. Photovoltaic Array During Bifacial Illumination

With the first United States (U.S.) photovoltaic array (PVA) activated on International Space Station (ISS) in December 2000, on-orbit data can now be compared to analytical predictions. Due to ISS operational constraints, it is not always possible to point the front side of the arrays at the Sun. Thus, in many cases, sunlight directly illuminates the backside of the PVA as well as albedo illumination on either the front or the back. During this time, appreciable power is produced since the solar cells are mounted on a thin, solar transparent substrate. It is important to present accurate predictions for both front and backside power generation for mission planning, certification of flight readiness for a given mission, and on-orbit mission support. To provide a more detailed assessment of the ISS power production capability, the authors developed a PVA electrical performance model applicable to generalized bifacial illumination conditions. On-orbit PVA performance data were also collected and analyzed. This paper describes the ISS PVA performance model, and the methods used to reduce orbital performance data. Analyses were performed using SPACE. a NASA-GRC developed computer code for the ISS program office. Results showed a excellent comparison of on-orbit performance data and analytical results.

Delleur, Ann M.↗

Material and design considerations of encapsulants for photovoltaic arrays in terrestrial applications

Procedures for analyzing cyclic mechanical stresses in encapsulated photovoltaic arrays designed for terrestrial application are discussed. The concept of 'thermal stiffness', the product of alpha and Young's modulus, is presented, and its usefulness for minimizing mechanical stresses is demonstrated. The concept of the 'proportional-limit' helps indicate the upper limit of design stress for plastics. System design is considered with attention to cell dimensions, cell to substrate adhesive, single encapsulant system, double layer encapsulant, and stresses in the interconnects. The permeability of polymeric materials to gases is examined.

Carroll, W.↗

Wind Loads on Flat Plate Photovoltaic Array Fields

The aerodynamic forces resulting from winds acting on flat plate photovoltaic arrays were investigated. Local pressure distributions and total aerodynamic forces on the arrays are shown. Design loads are presented to cover the conditions of array angles relative to the ground from 20 deg to 60 deg, variable array spacings, a ground clearance gap up to 1.2 m (4 ft) and array slant heights of 2.4 m (8 ft) and 4.8 m (16 ft). Several means of alleviating the wind loads on the arrays are detailed. The expected reduction of the steady state wind velocity with the use of fences as a load alleviation device are indicated to be in excess of a factor of three for some conditions. This yields steady state wind load reductions as much as a factor of ten compared to the load incurred if no fence is used to protect the arrays. This steady state wind load reduction is offset by the increase in turbulence due to the fence but still an overall load reduction of 2.5 can be realized. Other load alleviation devices suggested are the installation of air gaps in the arrays, blocking the flow under the arrays and rounding the edges of the array. A wind tunnel test plan to supplement the theoretical study and to evaluate the load alleviation devices is outlined.

Miller, R.↗

Pvarray: A software tool for photovoltaic array design

The application of PVARRAY, a software program for design of photovoltaic arrays are described. Results of sample parametric studies on array configurations are presented. It is concluded that PVARRAY could simulate a variety of configurations.

Burger, D. R.↗

Characterization of photovoltaic array performance - An overview

Techniques are described for standardized performance monitoring of photovoltaic arrays. Performance is measured in terms of the array electrical output for a given set of environmental or standard reporting conditions or the total output per given time interval. The environmental conditions can be a standard 25 C or the normal operating temperature in the presence of 80 mW/sq cm irradiance, 20 C air temperature and 1 m/sec wind velocity. Methods are presented for converting the measurements over time into I-V characteristics representations for entire arrays. The techniques are accurate to within 5 percent, provided in situ data are collected and the distribution of the measured parameters is known.

Ross, Ronald G., Jr.↗

Space Environment Testing of Photovoltaic Array Systems

To successfully operate a photovoltaic (PV) array system in space requires planning and testing to account for the effects of the space environment. It is critical to understand space environment interactions not only on the PV components, but also the array substrate materials, wiring harnesses, connectors, and protection circuitry.

Phillips, Brandon↗

Measurement Techniques and Instruments Suitable for Life-prediction Testing of Photovoltaic Arrays

The validation of a 20-year service life for low-cost photovoltaic arrays is a critical requirement in the Low-Cost Solar Array (LSA) Project. The validation is accomplished through accelerated life-prediction tests. A two-phase study was conducted to address the needs before such tests are carried out. The results and recommended techniques from the Phase 1 investigation are summarized in the appendix. Phase 2 of the study is covered in this report and consisted of experimental evaluations of three techniques selected from these recommended as a results of the Phase 1 findings. The three techniques evaluated were specular and nonspecular optical reflectometry, chemiluminescence measurements, and electric current noise measurements.

Noel, G. T.↗

An investigation of the effect of wind cooling on photovoltaic arrays

Convective cooling of photovoltaic modules for different wind conditions, including steady state controlled testing in a solar simulator and natural test environments in a field was investigated. Analytical thermal models of different module designs were used to correlate experimental data. The applicability of existing heat transfer correlations is confirmed. Reasonable agreement is obtained by applying a power law wind profile.

Wen, L.↗

Encapsulant materials for $2/watt terrestrial photovoltaic arrays

Materials properties, cost data, and strawman designs are presented relative to materials for $2/watt terrestrial photovoltaic arrays to meet LSA Project cost goals for 1982. It is shown that encapsulation materials can be categorized in six basic elements: top covers, super-strates, pottants, adhesives, substrates, and bottom covers. The roles of the six basic encapsulant material elements in the encapsulant system are discussed and candidate materials presented.

Maxwell, H.↗

Nonimaging concentrators for photovoltaic arrays in space

Two stage concentrators are studied in order to design an optimum concentrator for photovoltaic arrays in space. The study is directed at designs with two-dimensional geometries because they are better suited to moderate concentrations of about 10 X to 50 X, and because the instantaneous flux distribution is more uniform. It is found that with an f/0.5 primary, where f is the focal length of the primary, the flux distribution is very smooth regardless of the angle of incidence of the radiation. As the focal ratio is increased, peaks in the distribution begin to appear. The nonuniformities can be reduced by introducing small, closely spaced distortions into the reflecting surfaces, and practical arrays can achieve a concentration of 10 when the acceptance half angle is 4.25 deg or 50 when the acceptance half angle is + or - 1 deg.

Winston, R.↗

Feasibility Study of Solar Dome Encapsulation of Photovoltaic Arrays

The technical and economic advantages of using air-supported plastic enclosures to protect flat plate photovoltaic arrays are described. Conceptual designs for a fixed, latitude-tilt array and a fully tracking array were defined. Detailed wind loads and strength analyses were performed for the fixed array. Detailed thermal and power output analyses provided array performance for typical seasonal and extreme temperature conditions. Costs of each design as used in a 200 MWe central power station were defined from manufacturing and material cost estimates. The capital cost and cost of energy for the enclosed fixed-tilt array were lower than for the enclosed tracking array. The enclosed fixed-tilt array capital investment was 38% less, and the levelized bus bar energy cost was 26% less than costs for a conventional, glass-encapsulated array design. The predicted energy cost for the enclosed fixed array was 79 mills/kW-h for direct current delivered to the power conditioning units.

Source record↗

Reduction of intensity variations on a photovoltaic array with compound parabolic concentrators

The reduction of nonuniformities in the intensity distribution of light focused on a photovoltaic array by a compound parabolic concentrator is investigated. The introduction of small distortions into the surfaces of the reflector in order to diffuse the incident collimated light to fill the angular acceptance of the concentrator is calculated by means of ray tracing to decrease the irradiance nonuniformity at the cost of a lowered effective concentration of the concentrator. Measurements of the intensity distribution on a scale test model in terrestrial sunlight with corrugated aluminized mylar reflectors are shown to be in good agreement with the ray tracing results. A two-stage concentrator consisting of a focusing primary and a nonimaging secondary is also shown to result in a fairly uniform intensity distribution except in the case of a 4-deg incidence angle, which may be corrected by the introduction of distortions into one or both concentration stages.

Greenman, P.↗

Wind loads on flat plate photovoltaic array fields (nonsteady winds)

Techniques to predict the dynamic response and the structural dynamic loads of flat plate photovoltaic arrays due to wind turbulence were analyzed. Guidelines for use in predicting the turbulent portion of the wind loading on future similar arrays are presented. The dynamic response and the loads dynamic magnification factor of the two array configurations are similar. The magnification factors at a mid chord and outer chord location on the array illustrated and at four points on the chord are shown. The wind tunnel test experimental rms pressure coefficient on which magnification factors are based is shown. It is found that the largest response and dynamic magnification factor occur at a mid chord location on an array and near the trailing edge. A technique employing these magnification factors and the wind tunnel test rms fluctuating pressure coefficients to calculate design pressure loads due to wind turbulence is presented.

Miller, R. D.↗