Entropy Mode: Unlocking a New Parameter Space for Ozone Based Gas Optics
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.
Explore the source record for details and available documents.
SAO is working with LLNL to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above at NNSA facilities. Our work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter-I multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The mandrels for the custom optics are fabricated at MSFC. In previous contracts, SAO delivered several optics to LLNL with response at various energies. During this present contract period two tasks were carried out. Task1: the coating, replication and characterization of a custom optic with peak response at 22.8 keV, using the custom-designed SANZ mandrels. Task2: carrying out modifications to the coating chamber at SAO to accommodate new, longer, custom-designed mandrels (SANZlong) that will be fabricated at NASA MSFC in FY2020. The longer mandrels are necessary to mitigate end effects observed in the replication process for the small optics currently being fabricated.
We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.
Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.
Explore the source record for details and available documents.
A new technique to attenuate the unshifted deuterium Balmer-alpha (D-alpha) emission is developed and tested for the fast ion D-alpha (FIDA) diagnostic. The unshifted D-alpha emission, at λ = 656.1 nm, is around three orders of magnitude higher than the desired FIDA emission. Blocking the strong emission feature is essential to prevent blooming and light smearing on the CCD chip and scattered light contamination. The new method is a notch filter approach that utilizes the reflection from ultra-narrow bandpass filters to block the saturating signal before it enters the spectrometer. Collimated light from the fibers is reflected off the filter at a 15° angle of incidence. Measurements show that a center wavelength transmission of 0.006 and a blocking full width at half maximum of ~ 1 nm are achieved by using a 200 μm fiber and a 20 mm focal length collimator with two filters.
A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Smithsonian Astrophysical Observatory (SAO) is working with Lawrence Livermore National Laboratory (LLNL) to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above for National Nuclear Security Administration (NNSA) facilities. SAO work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The optics are fabricated using an electroform nickel replication technique which has been used to fabricate optics for X-ray astronomy satellites over the past two decades. This technique starts with a figured, polished mandrel from which the optics are replicated. To carry this technique over to fabricate optics for NNSA facilities, several additional barriers had to be overcome to deposit multilayer coatings on integral optics with radii as small as 25 mm. These breakthroughs allow fabrication of optics which meet the spatial and spectral specifications required by NNSA facilities. During this present contract period SAO delivered four custom optics to LLNL with spectral response at or near the Kα line of silver, 22.16 keV.
Tin contamination of the collector mirror surface remains one of the crucial issues of EUV (Extreme Ultraviolet) sources, directly impacting the availability of the tool. Hydrogen plasma-based tin removal processes employ hydrogen radicals and ions to interact with tin deposits to form gaseous tin hydride (SnH 4 ), which can be removed through pumping. An annular surface wave plasma (SWP) source developed at the University of Illinois—Urbana Champaign is integrated into the cone and perimeter of the collection mirror for in situ tin removal. The SWP is characterized by high ion and radical densities, low electron temperature, and local generation where etching is needed. This method has the potential to significantly reduce downtime and increase mirror lifetime. Radical probe measurements show hydrogen radical densities in the order of 10 19 m -3 , while Langmuir probe measurements show electron temperatures of up to 6 eV and plasma densities on the order of 10 17–18 m -3 . The generated ions are essential to the tin cleaning and have sufficiently low energy to cause no damage to the collector capping layer. Tin etch rates of up to 270 nm/min were observed in a variety of experimental conditions, including various powers, pressures, flowrates, and temperatures. In conclusion, the high etch rates demonstrated in this study exceed the expected contamination rate of the EUV source.
Explore the source record for details and available documents.
Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.
We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.