Search NASA⌕ Search

SEARCH · Search NASA

Results for “Piperazine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Development of LpxH Inhibitors Chelating the Active Site Dimanganese Metal Cluster of LpxH

Abstract Despite the widespread emergence of multidrug‐resistant nosocomial Gram‐negative bacterial infections and the major public health threat it brings, no new class of antibiotics for Gram‐negative pathogens has been approved over the past five decades. Therefore, there is an urgent medical need for developing effective novel antibiotics against multidrug‐resistant Gram‐negative pathogens by targeting previously unexploited pathways in these bacteria. To fulfill this crucial need, we have been investigating a series of sulfonyl piperazine compounds targeting LpxH, a dimanganese‐containing UDP‐2,3‐diacylglucosamine hydrolase in the lipid A biosynthetic pathway, as novel antibiotics against clinically important Gram‐negative pathogens. Inspired by a detailed structural analysis of our previous LpxH inhibitors in complex with K. pneumoniae LpxH ( Kp LpxH), here we report the development and structural validation of the first‐in‐class sulfonyl piperazine LpxH inhibitors, JH‐LPH‐45 ( 8 ) and JH‐LPH‐50 ( 13 ), that achieve chelation of the active site dimanganese cluster of Kp LpxH. The chelation of the dimanganese cluster significantly improves the potency of JH‐LPH‐45 ( 8 ) and JH‐LPH‐50 ( 13 ). We expect that further optimization of these proof‐of‐concept dimanganese‐chelating LpxH inhibitors will ultimately lead to the development of more potent LpxH inhibitors for targeting multidrug‐resistant Gram‐negative pathogens.

Pharmacology & Pharmacy↗

Bench-Scale Development of a Hybrid Membrane-Absorption CO 2 Capture Process

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept Polaris TM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, lowpressure- drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

99 GENERAL AND MISCELLANEOUS↗

Bench scale development of a hybrid membrane-absorption CO 2 capture process (Final Report)

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept PolarisTM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, low-pressure-drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

20 FOSSIL-FUELED POWER PLANTS↗

Conclusions from 3 years of continuous capture plant operation without exchange of the AMP/PZ-based solvent at Niederaussem – insights into solvent degradation management

A many times heard mantra of solvent degradation management in amine-based post combustion capture is “keep the solvent clean” to minimize solvent consumption. It is assumed that the amine losses would decrease by the removal of metals, degradation products, and reactive trace components which are captured from the flue gas, like NO 2 (as potentially driving components of the amine degradation besides dissolved O 2 ). However, this theoretical hypothesis – based on results from laboratory experiments typically generated with fresh amines – disregards the complexity of the solvent matrix, interaction of potential metal catalysts with degradation products and oxidizing agents, and specific chemical requirements which must be fulfilled before a degradation mechanism can proceed. Degradation of the solvent CESAR1 (aqueous solution of 3.0 molar 2-amino-2-methylpropan-1-ol (AMP) and 1.5 molar piperazine (PZ)) is investigated in a unique long-time test campaign (testing time up to now 40 months; 24/7 operation) without replacement of the solvent inventory at the capture pilot plant at the lignite-fired power plant in Niederaussem. Three solvent management strategies with different effect mechanisms are investigated and evaluated: (a) removal of only anionic compounds and trace elements (within 75 days solvent inventory treated two times) and anionic as well as cationic compounds and trace elements (114 days, inventory treated four times) from the solvent by ion exchange, (b) adsorptive removal of trace elements from the solvent by active carbon in 35% of the operating time, and (c) removal of >80% NO 2 by flue gas pretreatment with thiosulfate/sulfite solution (dosing for 2,000 h). The results of the testing program clearly show that “solvent cleanliness” is not a well-defined parameter and that results from laboratory tests, tests without fully representative industrial flue gasses, and short-term testing of monoethanolamine cannot be generalized for other solvents and industrial application. Furthermore, these results showcase that specific degradation management considering solvent, capture plant and flue gas quality is reasonable. Overshooting efforts for solvent management are contra-productive and produce unnecessary waste streams, efficiency losses and costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing membrane performance for CO 2 capture from flue gas with ultrahigh MW polyvinylamine

Membranes for post-combustion CO 2 capture are required to have a high CO 2 permeance due to the limited driving force. For facilitated transport membranes synthesized with polyvinylamine (PVAm), a defect-free selective layer of <200 nm is usually required to render sufficient permeance with high CO 2 /N 2 selectivity. In order to meet such a demand through the knife-coating process, the coating solution needs to have a high viscosity at a relatively low concentration to minimize its penetration into the substrate. The demand was met by synthesizing PVAm with an ultrahigh molecular weight (MW) via inverse emulsion polymerization (IEP) in this study. Compared to solution polymerization, IEP isolates the reaction in inverse micelles suspended in a continuous organic phase, which allows excellent dissipation of the heat generated by the reaction and reduces gel formation drastically. The polymerization parameters, including monomer concentration, initiator concentration, and reaction temperature, were investigated to obtain the optimal MW of PVAm for membrane performance. As compared to solution polymerization, IEP enhanced the MW of PVAm from 1.2 to 12.7 MDa, which minimized the penetration of the coating solution into the substrate and hence the extra mass transfer resistance. The effect of MW and degree of hydrolysis of PVAm on the membrane transport properties were studied. Furthermore, by employing PVAm with a MW of 12.7 MDa to strengthen the polymer matrix, the loading of piperazine glycinate in the membrane was increased up to 85 wt.%. In conclusion, the resultant membrane achieved a CO 2 permeance of 839 GPU and a CO 2 /N 2 selectivity of 161 at the typical flue gas temperature of 57°C.

20 FOSSIL-FUELED POWER PLANTS↗

Amine Oxidation Catalyzed by NO 2

Amine oxidation is a major risk in the deployment of amine scrubbing for CO2 capture from post-combustion flue gas. Oxidation probably occurs by dissolved oxygen at elevated temperature, Fe(III)/Fe(II) shuttling between the absorber and the stripper, and by NO2 in the absorber. Amine selection, dissolved oxygen removal, and solvent reclaiming mitigate oxidation due to dissolved oxygen and iron shuttle mechanism, but not by NO2. This work examines piperazine (PZ) oxidation by NO2 in a bench-scale high gas flow reactor (HGF). PZ is an effective second-generation solvent with high CO2 capacity, fast capture rate, good thermal stability, and good resistance to oxidation. Flue gas typically contains 0.5–5 ppm NO2 and 10–100 ppm NO. NO2 at 1 ppm in the flue gas appears to cause significant amine oxidation in pilot plant testing. PZ solution can easily absorb NO2, and it is hypothesized that NO2 can catalytically oxidize PZ through free-radical propagation. The issue may not be solved by a NO2 pre-scrubber since the coexistence of NO and O2 in the flue gas will keep producing non-negligible amounts of NO2 in the ductwork and the absorber after the NO2 incoming with the flue gas has been scrubbed. In addition, NO2 may not only oxidize PZ but also the intermediate degradation products, and it is unknown if the existence of dissolved iron influences the oxidation by NO2. Previous workers have also shown that NO2 is the stoichiometric source of nitrosamine. A comprehensive analysis of NO2 oxidation is needed to address solvent management and its health/environmental impact. The new high gas flow (HGF) reactor focuses only on the absorber environment and is simpler to interpret because it does not include oxidation at high temperatures and by dissolved metal catalysts from corrosion. This paper presents the results of HGF experiments and shows evidence to support a hypothesis of amine oxidation catalyzed by NO2, presents the synergic effect of NO2 and iron on amine oxidation, points out the different effects of NO2 in clean and degraded solvents, and demonstrates that NO2 not only can oxidize amines but also their degradation products.

NO2, iron, piperazine (PZ), solvent oxidation, sol↗

Stimuli‐Responsive Emission from Hybrid Metal Halides

Abstract Stimuli‐responsive photoluminescent (PL) materials have attracted considerable attention in recent years owing to their potential applications in anti‐counterfeiting, information encryption, and sensing. Further investigations of the transformation mechanism and potential applications of stimulus‐responsive PL materials are considerably important. In the current study, an organic–inorganic metal halide, C 9 H 15 N 3 SbCl 5 ([C 9 H 13 N 3 ] 2+ is a 1‐(2‐pyridyl) piperazine cation) is obtained, which exhibits a 0D structure withP‐1 space group. At room temperature, when excited by UV light, the C 9 H 15 N 3 SbCl 5 single crystals exhibit unimodal blue light emission at 405 nm, and grinding or hydrostatic pressure induces double‐peak emissions at 405 and 650 nm. Interestingly, double‐emission samples can be restored to single‐emission samples by short annealing or storage in air for 2 weeks, and this process is reversible. Luminescence response to mechanical stimuli can also be achieved in the presence of hydrochloric acid and water. Spectral analysis and the analysis of the microstructural changes revealed that the structural modifications of the inorganic group play a pivotal role in the response to the stimulus. Finally, a composite film device based on C 9 H 15 N 3 SbCl 5 is prepared to demonstrate the potential of these smart materials in anti‐counterfeiting and sensing applications.

Chemistry↗

Selection of solvents for integrated CO 2 absorption and electrochemical reduction systems

Abstract Solvent‐based electrochemical CO 2 reduction (CO 2 R) enables the production of chemicals or fuels using CO 2 from a preceding absorption process. Employing previously tested CO 2 capture solvents does not ensure their suitability for either CO 2 R or integrated CO 2 absorption‐reduction. We propose solvent selection criteria that include the CO 2 solubility, kinetic constant, ionic conductivity, concentration of the bicarbonate, carbamate, and solvent cation in the CO 2 ‐loaded solution, and sustainability indicators. They are implemented for solvent selection (a) from novel, aqueous mixtures of N ‐methylcyclohexylamine (MCA) with piperazine (PZ), 2‐amino‐2‐methyl‐1‐propanol (AMP), potassium hydroxide (KOH), and potassium chloride (KCl) and (b) from aqueous monoethanolamine (MEA), AMP, KOH, MCA, and PZ solutions. Versions of a modified Kent‐Eisenberg model for strong bases, carbamate, and non‐carbamate‐forming amine solutions are developed and parameterized through experimental equilibrium measurements. CO 2 R experimental results are presented for solutions of KOH and MCA + KOH, as these indicate desired trade‐offs for CO 2 absorption and reduction.

Amines↗

Electrocatalytic Effects of Au Nanoclusters in its Electrochemiluminescence Enhanced by Coreactant Tertiary Amines

Abstract Atomically precise metal nanoclusters are increasingly exploited in electrocatalysis such as water electrolysis and CO 2 reduction. The catalytic effects are generally evaluated by conventional electrochemical methods or end‐product analysis. Herein, near infrared electrochemiluminescence (ECL) of the nanoclusters is introduced as a new signaling mechanism to complement classical voltammetric analysis for elucidating essential electrocatalytic parameters. Coreactant ECL from an aqueous soluble Au 22 nanocluster (NCs) enhanced by a common pH buffer materials 4‐(2‐hydroxyethyl)‐1‐piperazineethanesulfonic acid (HEPES) and by a piperazine drug hydroxyzine (HDZ) is studied under oxidative reduction pathways. Foot of the wave analysis on voltametric features and the kinetics profiles in potential‐step experiments are studied in different nanocluster and coreactant concentrations. Benchmark parameters such as rate constants are determined under EC (Electron‐transfer‐Chemical‐reaction) mechanism as feasibility validations. Because the luminescence properties of AuNCs are sensitive to the surface ligands or adsorbents, ECL is proposed as a new signal readout for operando studies providing insights for governing reaction mechanism and kinetics during catalytic reactions. Retrospectively, mechanistic understanding of the complex multi‐step reactions during ECL generation can provide guidance for the evaluation and optimization of ECL property for better quantitative applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Research on oxygen solubility in aqueous amine solvents with common additives used for CO 2 chemical absorption

Oxidative degradation in amine based post-combustion carbon capture (PCCC) leads to solvent losses and decreased solvent performance. Oxygen (O 2 ) in the flue gas is dissolved into the aqueous solvent and can reactively degrade the amine component. Advanced aqueous amine solvents are designed to contain additional surfactant and anti-foam additives as well as two types of corrosion inhibitors. These additives contribute to improve the solvent performance while reducing foaming and corrosion of expensive equipment. This work examines the impact of these additives on oxygen solubility (or dissolved oxygen - DO) in various aqueous amines used in PCCC including ethanolamine (MEA), 1-amino-2-propanol (A2P), 2-amino-1-propanol (2A1P), 2-(methylamino)-ethanol (NMEA), 2-(ethylamine)-ethanol (2EAE), diethanolamine (DEA), methyl-diethanolamine (MDEA), dimethylethanolamine (DMEA), piperazine (PZ), 1,2-ethyldiamine (EDA), and 1,6 hexadiamine (HDA). Further, the impact of carbon loading on oxygen solubility with and without these additives was also examined. The surfactant and anti-foam additives had minimal impact on DO for all the solvents investigated. The two anticorrosion additives had opposite effects in the measured DO, 2- mercaptobenzothiazole (MBT) decreased the DO concentration, and sodium metavanadate showed an increase. These results indicate that several of these common additives can be expected to minimally affect DO related oxidative degradation in these advance amine solvents.

60 APPLIED LIFE SCIENCES↗