Search NASA⌕ Search

SEARCH · Search NASA

Results for “Planning software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Migrating data from TcSE to DOORS : an evaluation of the T-Plan Integrator software application.

This report describes our evaluation of the T-Plan Integrator software application as it was used to transfer a real data set from the Teamcenter for Systems Engineering (TcSE) software application to the DOORS software application. The T-Plan Integrator was evaluated to determine if it would meet the needs of Sandia National Laboratories to migrate our existing data sets from TcSE to DOORS. This report presents the struggles of migrating data and focuses on how the Integrator can be used to map a data set and its data architecture from TcSE to DOORS. Finally, this report describes how the bulk of the migration can take place using the Integrator; however, about 20-30% of the data would need to be transferred from TcSE to DOORS manually. This report does not evaluate the transfer of data from DOORS to TcSE.

99 GENERAL AND MISCELLANEOUS↗

NIF Projects Controls and Information Systems Software Quality Assurance Plan

Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

42 ENGINEERING↗

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗

SU-F-J-98: Improvement and Evaluation Of Deformation Image Registration On Parotid Glands During Radiation Therapy for Nasopharyngeal Cancer

Purpose: To quantitatively evaluate the strategic innovation and accuracy variation of deformation registration algorithm for parotid glands using the similarity Dice coefficient during the course of radiation therapy (RT) for nasopharyngeal cancer (NPC). Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions. Two kinds of contours for parotid glands on daily MVCTs were obtained by populating these contours from planning CTs to the daily CTs via rigid-body registration with or without the rotation shifts using the in-house tools and the Adaptive plan software (Adaptive Plan, TomoTherapy), and were edited manually if necessary. The diffeomorphic Demons algorithm developed in the in-house tool was used to propagate the parotid structures from the daily CTs to planning CTs. The differences of the mapped parotid contours in two methods were evaluated using Dice similarity index (DSI). Two-tailed t-test analysis was carried out to compare the DSI changes during the course of RT. Results: For 10 patient plans, the accuracy of deformation image registration (DIR) with the rotation shift was obviously better than those without the rotation shift. The Dice scores of the ipsi- and contra-lateral parotids for with and without the rotation shifts were found to be correlated with each other [0.904±0.031 vs 0.919±0.030 (p<0.001); 0.900±0.031 vs 0.910±0.032 (p<0.001)]. The Dice scores for the parotids have shown the reduction with the changes of parotid volumes during RT. The DSI values between the first and last fraction were 0.932±0.020 vs 0.899±0.030 in 10 patient plans. Conclusion: DIR was successfully improved using the strategic innovation for ART. And the decrease of DIR accuracy has also been found during the delivery of fractionated radiotherapy. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225).

60 APPLIED LIFE SCIENCES↗

SU-F-J-145: MRI-Guided Interventional Boost Radiotherapy for Rectal Cancer: Investigating the Feasibility of Adapting the Anatomy

Purpose: The recent development of an MRI-linac allows adaptation of treatments to the anatomy of the moment. This anatomy, in turn, could be altered into a more favorable situation for radiotherapy purposes. The purpose of this study is to investigate the potential dosimetric benefits of manipulating rectal anatomy in MRI-guided interventional external-beam radiotherapy for rectal cancer. Methods: For this retrospective analysis, four patients (1M/3F) diagnosed with rectal cancer were included. These underwent MR-imaging using sonography transmission gel as endorectal contrast at time of diagnosis and standard, non-contrast, MR-imaging prior to radiotherapy planning. In the contrast scan, the rectum is inflated by the inserted contrast gel, thereby potentially increasing the distance between tumor and the organs-at-risk (OAR). Both anatomies were delineated and 7- beam IMRT-plans were calculated for both situations (RT-standard and RT-inflated), using in-house developed treatment planning software. Each plan was aimed to deliver 15Gy to the planning target volume (PTV; tumor+3mm margin) with a D99>95% and Dmax<120% of the planned dose. The D2cc dose to the OAR were then compared for both situations. Results: At equal (or better) target coverage, we found a mean reduction in D2cc of 4.1Gy/237% [range 2.6Gy–6.3Gy/70%–621%] for the bladder and of 2.0Gy/145% [range −0.7Gy–7.9Gy/−73%–442%] for the small-bowel, for the RT-inflated compared to the RT-standard plans. For the three female patients, a reduction in D2cc of 5.2Gy/191% [range 3.2Gy–9.2Gy/44%–475%] for the gynecological organs was found. We found all D2cc doses to be better for the RT-inflated plans, except for one patient for whom the bladder D2cc dose was slightly increased. Conclusion: Reduction of OAR dose by manipulation of anatomy is feasible. Inflation of the rectum results in more distance between OAR and PTV. This leads to a substantial reduction in dose to OAR at equal or better target coverage.

60 APPLIED LIFE SCIENCES↗

NEAMS Software V&V Plan for the MARMOT Software

In order to ensure the accuracy and quality of the microstructure based materials models being developed in conjunction with MARMOT simulations, MARMOT must undergo exhaustive verification and validation. Only after this process can we confidently rely on the MARMOT code to predict the microstructure evolution within the fuel. Therefore, in this report we lay out a V&V plan for the MARMOT code, highlighting where existing data could be used and where new data is required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

VERAIO Software Management Plan

VERAIO is a set of utility codes used to provide a common set of input and outputs to the Virtual Environment for Reactor Applications (VERA). VERA is a collection of several different computer codes that all have a common input and output. This prevents the need to manage input and output from each individual code, allowing for ease of use and reducing errors associated with code operability. The VERAIO utilities include VERAIn, VERAView, and VERARun. Each of these utilities is described below. VERAIn is an input processor that reads an ASCII input file generated by users, parses the file, performs some error checking, and writes an XML file to be read by other VERA codes. The main purpose of VERAIn is to provide a common input to all of the VERA codes so users only need to learn one input. VERAIn is written in Perl and uses YAML configuration files to provide flexibility. VERAView is a graphical user interface (GUI) that reads a VERA HDF output file and allows users to visualize results. VERAView is written in Python. VERARun is a script that drives the VERA execution in a high performance computing (HPC) environment. Work performed at the code level supports the Quality Assurance Program Plan (QAPP) (VERA-QA-001), and VERA Software Quality Assurance Plan (VERA-QA-002).

97 MATHEMATICS AND COMPUTING↗

MPACT Software Management Plan (V.4.3)

The MPACT code solves a discretized form of the Boltzmann transport equation on a wide variety of geometries and is distributed with a multigroup neutron cross section library. MPACT provides an advanced geometrically resolved neutral-particle transport capability to solve the flux distribution throughout the entire problem geometry, and it can model the isotopic depletion, decay, and activation of materials. The flux solution in MPACT is provided using a 2D/1D synthesis method within the framework of the 3D coarse mesh finite difference (CMFD) method for which axial and radial correction factors are obtained from 2D method of characteristics (MOC) and 1D nodal expansion method (NEM), PN, or SN. Other key characteristics of the MPACT code include the subgroup method and the embedded self-shielding method (ESSM) for resonance treatment, depletion capability based on the ORIGEN exponential matrix method, and a simplified thermal-hydraulics method for temperature/fluid feedback. The sole purpose of the simplified feedback model is to provide a mechanism for testing during code development and to provide a limited capability for educational applications. Work performed at the code level supports the VERA-QA-001, quality assurance program plan (QAPP) and VERA-QA-002, VERA Software Quality Assurance Plan.

97 MATHEMATICS AND COMPUTING↗

Software Quality Assurance Plan: Argonne Reactor Code Software

The Argonne Reactor Code (ARC) software package consists of 13 primary and many secondary pieces of software that are connected through interface files. The ARC software suite supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

VERAIO Software Management Plan

VERAIO is a set of utility codes used to provide a common set of inputs and outputs to the Virtual Environment for Reactor Applications (VERA). VERA is a collection of several different computer codes that all have a common input and output. This prevents the need to manage input and output from each individual code, allowing for ease of use and reducing errors associated with code operability. The VERAIO utilities include VERAIn, VERAView, and VERARun. Each of these utilities is described below. VERAIn is an input processor that reads an ASCII input file generated by users, parses the file, performs some error checking, and writes an XML file to be read by other VERA codes. The main purpose of VERAIn is to provide a common input to all of the VERA codes, so users only need to learn one input. VERAIn is written in Perl and uses YAML configuration files to provide flexibility. VERAView is a graphical user interface (GUI) that reads a VERA hierarchical data format (HDF) output file and allows users to visualize results. VERAView is written in Python. VERARun is a script that drives the VERA execution in a high performance computing (HPC) environment. Work performed at the code level supports the quality assurance program plan (QAPP) (VERA-QA-001) and the VERA Software Quality Assurance Plan (VERA-QA-002).

97 MATHEMATICS AND COMPUTING↗

A product data network to enable faster, easier, and better planning of building envelopes

The building envelopes contributes significantly to the energy-efficiency of the building. Building performance simulation has made it possible to compare façade technologies regarding energy demand, daylighting, thermal and visual comfort in detail. Planners, such as architects and engineers, need experience to find product data with the right quality and level of detail, and to process the data to fit the calculation and the application. In the available time, planners can compare only a limited number of products, which means that better solutions could go unnoticed. This paper presents a new concept for making product data easily accessible for building façade planning. The concept consists of a network of databases for the efficient exchange and use of optical and calorimetric data of glazing units, shading devices, and combinations of both. The paper presents the research questions, an analysis of the current challenges, six design goals for the product data network and its implementation together with a discussion. Many product data sources can be connected to many planning software applications via the specified application programming interface. When planning software connects to the product data network, the planning of building envelopes can be much faster because planners do not need to spend so much time to search and process product data manually. The planning of building envelopes can also become much easier, especially for planners with limited experience. They do not need to understand all the details about which data fits which calculation if the software company implements this. The planning of building envelopes can become much more reliable when software companies validate their use of the product data network, because the current manual process is prone to errors. The planning of building envelopes can also improve because more products can be compared in the available time, allowing better solutions to be found.

Maurer, Christoph↗

Griffin Software Development Plan

Griffin is a MOOSE-based reactor physics application for advanced reactor multiphysics modeling and simulation. The application is developed in a consistent multiphysics environment with strong software quality assurance. Griffin inherited most of the capabilities of MAMMOTH/Rattlesnake and is adopting the capabilities from PROTEUS that are needed in the code. The toolset includes a variety of deterministic radiation transport solvers for fixed source, k-eigenvalue, ad-joint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. The code contains the cross-section preparation capabilities applicable to fast and thermal reactors, including TRISO-fueled reactors. Core management capabilities include core performance, fuel depletion and shuffling, equilibrium core calculation, pebble-bed reactor run-in and equilibrium core, molten-salt reactor delayed neutron precursor drift, and control rod and drum movement with cusping correction. This software development plan presents the current and future capabilities and features in Griffin for the design and analysis of non-light-water reactor systems in steady-state and transient conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Automating Software Productivity Planning: Lightweight Tools for Upgrading Team Practices

A lightweight iterative workflow, called Productivity and Sustainability Improvement Planning (PSIP) has been developed to assist software teams with employing good software engineering practices. Three PSIP tools automate practice summarization, self-assessment, and progress tracking to enhance team engagement around software process improvement: Reposcanner, RateYourProject (RYP) and Progress Tracking Cards (PTCs) respectively. Reposcanner is a data analysis tool. RYP is an interactive self-assessment tool that provides an easy-to-use entry point to the PSIP process. Once process improvements are identified, PTCs are created by teams to measure outcomes and progression toward their goals. We present an exemplifying case study with a software team where these tools have been put to use, along with a description of the tools, and future plans for further improvements.

Raybourn, Elaine↗

Scripting in Radiation Therapy: An Automatic 3D Beam-Naming System

Scripts can be executed within the radiation treatment planning software framework to reduce human error, increase treatment planning efficiency, reduce confusion, and promote consistency within an institution or even among institutions. Scripting is versatile, and one application is an automatic 3D beam-naming system that describes the position of the beam relative to the patient in 3D space. The naming system meets the need for nomenclature that is conducive for clear and accurate communication of beam entry relative to patient anatomy. In radiation oncology in particular, where miscommunication can cause significant harm to patients, a system that minimizes error is essential. Frequent sharing of radiation treatment information occurs not only among members within a department but also between different treatment centers. Descriptions of treatment beams are perhaps the most commonly shared information about a patient's course of treatment in radiation oncology. Automating the naming system by the use of a script reduces the potential for human error, improves efficiency, enforces consistency, and would allow an institution to convert to a new naming system with greater ease. This script has been implemented in the Department of Radiation Oncology at the University of Washington Medical Center since December 2009. It is currently part of the dosimetry protocol and is accessible by medical dosimetrists, radiation oncologists, and medical physicists. This paper highlights the advantages of using an automatic 3D beam-naming script to flawlessly and quickly identify treatment beams with unique names. Scripting in radiation treatment planning software has many uses and great potential for improving clinical care.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery.

60 APPLIED LIFE SCIENCES↗

SU-F-T-55: Reproducibility of Interstitial HDR Brachytherapy Plans

Purpose: Treating gynecological cancers with interstitial high-dose-rate (HDR) brachytherapy requires precise reconstruction of catheter positions to obtain accurate dosimetric plans. In this study, we investigated the degree of reproducibility of dosimetric plans for Syed HDR brachytherapy. Methods: We randomly selected five patients having cervix-vaginal cancer who were recently treated in our clinic with interstitial HDR brachytherapy with a prescription dose of 25–30 Gy in five fractions. Interstitial needles/catheters were placed under fluoroscopic guidance and intra-operative 3T MRI scan was performed to confirm the desired catheter placement for adequate target volume coverage. A CT scan was performed and fused with the MRI for delineating high-risk CTV (HR-CTV), intermediate-risk CTV (IR-CTV) and OARs. HDR treatment plans were generated using Oncentra planning software. A single plan was used for all five fractions of treatment for each patient. For this study, we took the original clinical plan and removed all the reconstructed catheters from the plan keeping the original contours unchanged. Then, we manually reconstructed all the catheters and entered the same dwell time from the first original clinical plan. The dosimetric parameters studied were: D90 for HR-CTV and IR-CV, and D2cc for bladder, rectum, sigmoid and bowel. Results: The mean of absolute differences in dosimetric coverage (D90) were (range): 1.3% (1.0–2.0%) and 2.0% (0.9–3.6%) for HR-CTV and IR-CTV, respectively. In case of OARs, the mean of absolute variations in D2cc were (range): 4.7% (0.7–8.9%) for bladder, 1.60% (0.3–3.2%) for rectum, 1.6% (0–3.9%) for sigmoid, and 1.8% (0–5.1%) for bowel. Conclusion: Overall, the reproducibility of interstitial HDR plans was within clinically acceptable limit. Observed maximum variation in D2cc for bladder. If number of catchers and dwell points were relatively low or any one catheter was heavily loaded, then reproducibility of the plan was more sensitive to the accuracy of catheter reconstruction.

60 APPLIED LIFE SCIENCES↗