Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cold plasma diagnostics using satellite measurements of VLF signals from ground transmitters

A diagnostic technique to obtain the cold-plasma density profile in the magnetosphere is introduced. This method uses satellite measurements of group delay and pulse duration of VLF signals from ground transmitters in conjunction with a detailed ray-tracing analysis. An iterative method is involved which starts with an approximate density profile, computes the ray paths for that profile, and then compares the properties of the rays that reach the satellite location with the actual satellite measurements. The density profile is then modified to account for any discrepancies between the two results. The same process is repeated with the new profile until one has reasonable agreement between the data and ray-tracing results. This method is applied to the case of an Imp 6 pass, where strong signals from the Siple VLF transmitter were observed for over 25 min. Good agreement is found between the results of the proposed technique and the well-known ground whistler techniques of cold-plasma diagnostics. The results also serve to illustrate the wide diversity of propagation paths from ground transmitters to high-altitude satellites during VLF wave-injection experiments.

Inan, U. S.↗

Material injection alleviation and plasma diagnostic measurements during the RAM C-III flight.

The results of a material injection RF blackout alleviation experiment and of plasma diagnostic measurements using electrostatic probes and an S-band reflectometer in a 25,000 ft/sec reentry flight are presented. Significant alleviation of RF blackout is observed at altitudes of from 270,000 feet to 120,000 feet due to injection of water and Freon E-3 on VHF, S-band, C-band, and X-band frequencies. Electrostatic probe data, attenuation data, and S-band diagnostic data show consistent plasma results. The relative effectiveness of water and Freon E-3 is discussed.

Schroeder, L. C.↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostics package measurements of ionospheric ions and Shuttle-induced perturbations

The plasma diagnostics package (PDP) on the Space Shuttle STS-3 mission in March 1982 carried among its instrument complement a retarding potential analyzer. This instrument measured both the ambient ion plasma density and temperature, and perturbations to the plasma produced by Shuttle Orbiter effects. Whenever the plasma flow streamline at the instrument was more than a distance of the order of thermal ion gyroradii away from any Orbiter surface, the measurements were characteristic of the ambient ionosphere. In several situations, the PDP was positioned so as to scan the wake in the plasma flow produced by Orbiter surfaces. The density profile of the major species O(+) was consistent with a classic Mach cone. However, strong perturbations extended for several meters outside the Mach cone, which resulted in failure of flowing Maxwellian distributions to represent the data. Configurations where the plasma-flow-impacted Orbiter surfaced downstream of the PDP resulted in generation of a suprathermal ion component. The observations are discussed in terms of a recent model of the mechanism for generation of Shuttle glow.

Reasoner, David L.↗

Millimeter-Wave Imaging Technology Development for Real-Time 2D and 3D Fusion Plasma Diagnostics

Including a one year No-Cost Extension, The University of California, Davis has been funded since 2020 to advance innovative millimeter-wave diagnostics for fusion plasma research. This work includes: (1) Developing and applying cutting-edge System-on-Chip millimeter wave Integrated Circuit (IC) technology for Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometry (MIR) on the DIII-D tokamak and the NSTX-U spherical tokamak. (2) Development of radiation-hardened millimeter-wave chip for diagnostics in harsh environments, utilizing wide bandgap Gallium Nitride (GaN) semiconductors. (3) Integrating forward-modeling synthetic diagnostics to enable advanced, real-time plasma prediction and feedback control. Originally planned as a three-year program (2020–2023), the project was granted a one-year no-cost extension, extending its duration through the end of 2024.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostics package. Volume 1: OSS-1 section

This volume (1) of the Plasma Diagnostics Package (PDP) final science report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-3 as a part of the Office of Space Science first payload (OSS-1). This work was performed during the period of launch, March 22, l982, through June 30, l983. During this period the primary data reduction effort consisted of processing summary plots of the data received by the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). The scientific analyses during the performance period consisted of general studies which incorporated the results of several of the PDP's instruments, detailed studies which concentrated on data from only one or two of the instruments, and joint studies of beam-plasma interactions with the OSS-1 Fast Pulse Electron Generator (FPEG) of the Vehicle Charging and Potential Investigation (VCAP). Internal reports, published papers and oral presentations which involve PDP/OSS-1 data are listed in Sections 3 and 4. A PDP/OSS-1 scientific results meeting was held at the University of Iowa on April 19-20, 1983. This meeting was attended by most of the PDP and VCAP investigators and provided a forum for discussing and comparing the various results, particularly with regard to the shuttle orbiter environment. One of the most important functional objectives of the PDP on OSS-1 was to characterize the orbiter environment.

Pickett, Jolene S.↗

STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of Orbiter transmitter and subsystem electromagnetic interference

The plasma diagnostics package receiver system is described to identify the various antennas and to characterize the complement of receivers which cover the frequency range of 30 Hz to 800 Hz and S-band at 2200 + or - 300 MHz. Sample results are presented to show the variability of electromagnetic effects associated with the orbiter and the time variability of these effects. The electric field and magnetic field maximum and minimum field strength spectra observed during the mission at the pallet location are plotted. Values are also derived for the maximum UHF transmitter and S-band transmitter field strengths. Calibration data to convert from the survey plots to actual narrowband and broadband field strengths are listed.

Shawhan, S. D.↗

Plasma diagnostics and modeling of lithium-containing plasmas

Thin-film deposition from chemically reactive multi-component plasmas is complex, and the lack of electron collision cross-sections for even the most common metalorganic precursors and their fragments complicates their modeling based on fundamental plasma physics. This study focuses on understanding the plasma physics and chemistry in argon (Ar) plasmas containing lithium bis (trimethylsilyl) amide used to deposit Li x Si y thin films. These films are emerging as potential solid electrolytes for lithium-ion batteries, and the Li-to-Si ratio is a crucial parameter to enhance their ionic conductivity. We deposited Li x Si y films in an axial flow-through plasma reactor and studied the factors that determine the variation of the Li-to-Si ratio in films deposited at various points on a substrate spanning the entire reactor axis. While the Li-to-Si ratio is 1:2 in the precursor, the Li-to-Si ratio is as high as 3:1 in films deposited near the plasma entrance and decreases to 1:1 for films deposited downstream. Optical emission from the plasma is dominated by Li emission near the entrance, but Li emission disappears downstream, which we attribute to the complete consumption of the precursor. We hypothesized that the axially decreasing precursor concentration affects the electron energy distribution function in a way that causes different dissociation efficiencies for the production of Li and Si. We used Li line intensities to estimate the local precursor concentration and Ar line ratios to estimate the local reduced electric field to test this hypothesis. This analysis suggests that the mean electron energy increases along the reactor axis with decreasing precursor concentration. As a result, the decreasing Li-to-Si ratio with axially decreasing precursor concentration may be explained by Li release from the precursor having lower threshold energy than Si release.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron resonance deposition and plasma diagnostics of a-Si:H and a-C:H films

Amorphous silicon (a-Si:H) and amorphous carbon (a-C:H) films deposited by electron cyclotron resonance (ECR) microwave plasma-enhanced chemical vapor deposition are discussed. It is shown that the ECR microwave plasma deposition technique can produce a-Si:H films with material qualities similar to and with a deposition rate one order of magnitude higher than for films deposited by radio-frequency glow discharge. The ECR-deposited a-C:H films are characterized by fluorescence, IR, and Raman spectroscopy. In situ optical emission spectroscopy plasma diagnostics indicates that ECR plasmas have a strong emission at 434 nm, which indicates a higher chemical reactivity than radio-frequency glow discharge plasmas. The radio frequency bias to the substrate is found to play a critical role in determining the film structure and the carbon bonding configuration of ECR-deposited a-C:H films.

Shing, Y. H.↗

Design of a 140 GHz waveguide notch filter for millimeter-wave receiver module protection in fusion plasma diagnostics

A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Here, utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE 11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110–138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostics package assessment of the STS-3 orbiter environment and systems for science

Primary objectives of the Plasma Diagnostics Package (PDP) on STS-3 as part of the OSS-1 'Pathfinder' payload were to measure aspects of the Orbiter's induced environment and to utilize Orbiter crew and subsystems in the conduct of scientific investigations. Instrumentation temperatures were found to be within predicted limits, payload bay pressure varied from ambient up to 0.001 torr with thruster firings, EMI levels were found to be below worst case estimates, and V x B motional potentials were observed to vary + or - 5 V with respect to Orbiter ground. These parameters exhibited orbit-period modulation. Payload bay plasma varied in density and composition from ambient to a rarefied mixture with Orbiter-produced H2O(+). Energetic electrons and ions with energies up to 10's of eV were observed occasionally. Primary and vernier thrusters induce a momentary perturbation to the electron density, to the pressure and to the electric field with low energy ions and electrons occasionally produced. With the PDP on the RMS, both automode and manual modes were used to seek sources of EMI, to characterize the Orbiter's plasma wake and to measure beam-plasma phenomena.

Shawhan, S. D.↗

Measurements by the plasma diagnostics package on STS-3

A comprehensive set of measurements about the orbiter environment are provided by the plasma diagnostics package (PDP). Ion and electron particle densities, energies, and spatial distribution functions; ion mass for identification of particular molecular ion species; and magnetic fields, electric fields and electromagnetic waves over a broad frequency range are studied. Shuttle environmental measurements will be made both on the pallet and, by use of the remote manipulator system (RMS), the PDP will be maneuvered in and external to the bay area to continue environmental measurements and to carry on a joint plasma experiment with the Utah State University fast-pulsed electron generator. Results of orbiter environment EMI measurements and S-band field strengths as well as preliminary results from wake search operations indicating wake boundary identifiers are reported.

Shawhan, S. D.↗

A review of the findings of the plasma diagnostic package and associated laboratory experiments: Implications of large body/plasma interactions for future space technology

The discoveries and experiments of the Plasma Diagnostic Package (PDP) on the OSS 1 and Spacelab 2 missions are reviewed, these results are compared with those of other space and laboratory experiments, and the implications for the understanding of large body interactions in a low Earth orbit (LEO) plasma environment are discussed. First a brief review of the PDP investigation, its instrumentation and experiments is presented. Next a summary of PDP results along with a comparison of those results with similar space or laboratory experiments is given. Last of all the implications of these results in terms of understanding fundamental physical processes that take place with large bodies in LEO is discussed and experiments to deal with these vital questions are suggested.

Murphy, Gerald B.↗

A physical parameter method for the design of broad-band X-ray imaging systems to do coronal plasma diagnostics

The technique commonly used for the analysis of data from broad-band X-ray imaging systems for plasma diagnostics is the filter ratio method. This requires the use of two or more broad-band filters to derive temperatures and line-of-sight emission integrals or emission measure distributions as a function of temperature. Here an alternative analytical approach is proposed in which the temperature response of the imaging system is matched to the physical parameter being investigated. The temperature response of a system designed to measure the total radiated power along the line of sight of any coronal structure is calculated. Other examples are discussed.

Kahler, S.↗

Plasma diagnostics package. Volume 2: Spacelab 2 section, part A

This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, l985, through June 30, l988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). The scientific analyses during the performance period consisted of follow-up studies of shuttle orbiter environment and orbiter/ionosphere interactions and various plasma particle and wave studies which dealt with data taken when the PDP was on the Remote Manipulator System (RMS) arm and when the PDP was in free flight. Of particular interest during the RMS operations and free flight were the orbiter wake studies and joint studies of beam/plasma interactions with the SL-2 Fast Pulse Electron Generator (FPEG) of the Vehicle Charging and Potential Investigation (VCAP). Internal reports, published papers and presentations which involve PDP/SL-2 data are listed in Sections 3 and 4. A PDP/SL-2 scientific results meeting was held at the University of Iowa on June 10, l986. This meeting was attended by most of the PDP and VCAP investigators and provided a forum for discussing and comparing the various results, particularly with regard to the PDP free flight.

Pickett, Jolene S.↗

Flight Plasma Diagnostics for High-Power, Solar-Electric Deep-Space Spacecraft

NASA's Asteroid Redirect Robotic Mission (ARRM) project plans included a set of plasma and space environment instruments, the Plasma Diagnostic Package (PDP), to fulfill ARRM requirements for technology extensibility to future missions. The PDP objectives were divided into the classes of 1) Plasma thruster dynamics, 2) Solar array-specific environmental effects, 3) Plasma environmental spacecraft effects, and 4) Energetic particle spacecraft environment. A reference design approach and interface requirements for ARRM's PDP was generated by the PDP team at JPL and GRC. The reference design consisted of redundant single-string avionics located on the ARRM spacecraft bus as well as solar array, driving and processing signals from multiple copies of several types of plasma, effects, and environments sensors distributed over the spacecraft and array. The reference design sensor types were derived in part from sensors previously developed for USAF Research Laboratory (AFRL) plasma effects campaigns such as those aboard TacSat-2 in 2007 and AEHF-2 in 2012.

Johnson, Lee↗