Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Composite with In Situ Plenums

A document describes a high-performance thermal distribution panel (TDP) concept using high-conductivity (greater than 800 W/mK) macro composite skin with in situ heat pipes. The processing technologies proposed to build such a panel result in a one-piece, inseparable assembly with high conductance in both the X and Y planes. The TDP configuration can also be used to produce panels with high structural stiffness. The one-piece construction of the TDP eliminates the thermal interface between the cooling plenums and the heat spreader base, and obviates the need for bulky mounting flanges and thick heat spreaders used on baseline designs. The conductivity of the TDP can be configured to exceed 800 W/mK with a mass density below 2.5 grams per cubic centimeter. This material can provide efficient conductive heat transfer between the in situ heat plenums, permitting the use of thinner panel thicknesses. The plenums may be used as heat pipes, loop heat pipes, or liquid cooling channels. The panel technology used in the TDP is a macro-composite comprised of aluminum-encapsulated annealed pyrolytic graphite (APG). APG is highly aligned crystalline graphite with an in-plane thermal conductivity of 1,700 W/mK. APG has low shear strength and does not constrain the encapsulating material. The proposed concept has no thermal interfaces between the heat pipes and the spreader plate, further improving the overall conductance of the system. The in situ plenums can also be used for liquid cooling applications. The process can be used to fabricate structural panels by adding a second thin sheet.

Montesano, Mark↗

Turbine airfoil with leading edge cooling passage(s) coupled via plenum to film cooling holes, and related method

A turbine airfoil includes a body including a wall defining pressure and suction sides, and a leading edge extending between the pressure and suction sides. A cooling circuit inside the wall of the body includes at least one of: a) a suction side to pressure side cooling sub-circuit including a first cooling passage(s) extending from the suction side to the pressure side around the leading edge to a first plenum, and a plurality of first film cooling holes communicating with the first plenum and extending through the wall on the pressure side; and b) a pressure side to suction side cooling sub-circuit including second cooling passage(s) extending from the pressure side to the suction side around the leading edge to a second plenum, and a plurality of second film cooling holes communicating with the second plenum and extending through the wall on the suction side.

Lacy, Benjamin Paul↗

Computational study of full-scale VHTR lower plenum for turbulent mixing assessment

Next-generation nuclear reactors are poised to efficiently provide reliable power at enhanced safety levels for many years to come. Among the fundamental designs for these reactors is the very-hightemperature reactor (VHTR), which employs helium as the primary coolant and has the potential of reaching elevated temperatures such that chemical processing (e.g., electrolysis for hydrogen production) is viable alongside traditional electricity generation. This and other next-generation reactors also represent a strategic bridge for ultimately transitioning from fossil fuel-dominated energy portfolios to one where renewable options abound. For the VHTR, the ultimate goal of constructing a new plant will be preceded by additional fundamental research aimed at generating trusted models for behavior prediction under normal and accident scenarios. This paper presents a detailed computational fluid dynamics simulation of the lower plenum, where hot coolant from the core mixes together in a turbulent fashion before traveling to power conversion equipment. Because the flow is expected to enter the lower plenum across a wide range of temperatures and velocities, concerns exist when the mixing is incomplete. The potential hot spots on cylindrical support pedestals and the uniformity of the main outlet are the primary metrics of interest in this study, along with flow velocities and temperatures at different locations within the lower plenum. Three locations are probed in detail and suggest a large range exists for approach velocities and temperatures. A large degree of stratification is also seen on the surfaces of the support pedestals, suggesting a facility should accommodate testing for such behavior. The characterizations presented provide the valuable data needed in order to design appropriate experimental testbeds, where scaled modeling can be carried out in a manner meaningful in predicting the full-scale behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computational Fluid Dynamic Analysis for the Proposed VHTR Lower Plenum Standard Problem

One of the reference designs for the Next Generation Nuclear Plant (NGNP) is a prismatic reactor configuration. A major concern in the operation of this design is the nature of the flow of hot gas as it exits the core into the lower plenum and then out the vessel exit duct. The two primary areas of concern are the impingement of hot jets onto the walls of the lower plenum and the degree of thermal mixing of the helium coolant as it flows out of the reactor vessel. Computational fluid dynamic (CFD) simulations have been proposed by general consensus to estimate the desired local fluid dynamic and temperature information. Successful CFD simulations require careful planning and extensive calculations to help ensure that they accurately represent the flow physics. An important aspect of the application of CFD is to validate the results against detailed validation data, for scaled problems that involve similar physics. A section of the lower plenum of the reference prismatic NGNP was employed to create a scaled model to use to obtain experimental data for use as validation data to compare with a CFD analysis. Extensive flow data were obtained from the scaled model while installed in the INL’s Matched Index of Refraction (MIR) test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CFD Analysis of Upper Plenum Flow for a Sodium-Cooled Small Modular Reactor

Upper plenum flow behavior is important for many operational and safety issues in sodium fast reactors. The Prototype Gen-IV Sodium Fast Reactor (PGSFR), a pool-type, 150 MWe output power design, was used as a reference case for a detailed characterization of upper plenum flow for normal operating conditions. Computational Fluid Dynamics (CFD) simulation was utilized with detailed geometric modeling of major structures. Core outlet conditions based on prior system-level calculations were mapped to approximate the outlet temperatures and flow rates for each core assembly. Core outlet flow was found to largely bypass the Upper Internal Structures (UIS). Flow curves over the shield and circulates within the pool before exiting the plenum. Cross-flows and temperatures were evaluated near the core outlet, leading to a proposed height for the core outlet thermocouples to ensure accurate assembly-specific temperature readings. A passive scalar was used to evaluate fluid residence time from core outlet to IHX inlet, which can be used to assess the applicability of various methods for monitoring fuel failure. Additionally, the gas entrainment likelihood was assessed based on the CFD simulation results. Based on the evaluation of velocity gradients and turbulent kinetic energies and the available gas entrainment criteria in the literature, it was concluded that significant gas entrainment is unlikely for the current PGSFR design.

computational fluid dynamics↗

Experimental and CFD Studies of Coolant Flow Mixing within Scaled Models of the Upper and Lower Plenums of NGNP Gas-Cooled Reactors

A 1/16th scaled VHTR experimental model was constructed and the preliminary test was performed in this study. To produce benchmark data for CFD validation in the future, the facility was first run at partial operation with five pipes being heated. PIV was performed to extract the vector velocity field for three adjacent naturally convective jets at statistically steady state. A small recirculation zone was found between the pipes, and the jets entered the merging zone at 3 cm from the pipe outlet but diverged as the flow approached the top of the test geometry. Turbulence analysis shows the turbulence intensity peaked at 41-45% as the jets mixed. A sensitivity analysis confirmed that 1000 frames were sufficient to measure statistically steady state. The results were then validated by extracting the flow rate from the PIV jet velocity profile, and comparing it with an analytic flow rate and ultrasonic flowmeter; all flow rates lie within the uncertainty of the other two methods for Tests 1 and 2. This test facility can be used for further analysis of naturally convective mixing, and eventually produce benchmark data for CFD validation for the VHTR during a PCC or DCC accident scenario. Next, a PTV study of 3000 images (1500 image pairs) were used to quantify the velocity field in the upper plenum. A sensitivity analysis confirmed that 1500 frames were sufficient to precisely estimate the flow. Subsequently, three (3, 9, and 15 cm) Y-lines from the pipe output were extracted to consider the output differences between 50 to 1500 frames. The average velocity field and standard deviation error that accrued in the three different tests were calculated to assess repeatability. The error was varied, from 1 to 14%, depending on Y-elevation. The error decreased as the flow moved farther from the output pipe. In addition, turbulent intensity was calculated and found to be high near the output. Reynolds stresses and turbulent intensity were used to validate the data by comparing it with benchmark data. The experimental data gave the same pattern as the benchmark data. A turbulent single buoyant jet study was performed for the case of LOFC in the upper plenum of scaled VHTR. Time-averaged profiles show that 3,000 frames of images were sufficient for the study up to second-order statistics. Self-similarity is an important feature of jets since the behavior of jets is independent of Reynolds number and a sole function of geometry. Self-similarity profiles were well observed in the axial velocity and velocity magnitude profile regardless of z/D where the radial velocity did not show any similarity pattern. The normal components of Reynolds stresses have self-similarity within the expected range. The study shows that large vortices were observed close to the dome wall, indicating that the geometry of the VHTR has a significant impact on its safety and performance. Near the dome surface, large vortices were shown to inhibit the flows, resulting in reduced axial jet velocity. The vortices that develop subsequently reduce the Reynolds stresses that develop and the impact on the integrity of the VHTR upper plenum surface. Multiple jets study, including two, three and five jets, were investigated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect on supersonic jet noise of nozzle plenum pressure fluctuations.

Demonstration that pressure fluctuations in the plenum chamber to a supersonic nozzle can strongly increase the noise radiated from the jet plume. The correlation shows that jet noise acoustic efficiency increases from 0.3% to 0.8% (or 4 dB) when the chamber roughness intensity increases from essentially no plenum chamber roughness to 2%. A roughness level of 2% has been observed in some turbojet engines. It is concluded that the reduction or elimination of plenum chamber pressure fluctuations may be an important method of reducing the total noise from jet engines.

Kushida, R.↗

Experimental evaluation of blockage ratio and plenum evacuation system flow effects on pressure distribution for bodies of revolution in 0.1 scale model test section of NASA Lewis Research Center's proposed altitude wind tunnel

An experimental investigation was conducted in the slotted test section of the 0.1-scale model of the proposed Altitude Wind Tunnel to evaluate wall interference effects at tunnel Mach numbers from 0.70 to 0.95 on bodies of revolution with blockage rates of 0.43, 3, 6, and 12 percent. The amount of flow that had to be removed from the plenum chamber (which surrounded the slotted test section) by the plenum evacuation system (PES) to eliminate wall interference effects was determined. The effectiveness of tunnel reentry flaps in removing flow from the plenum chamber was examined. The 0.43-percent blockage model was the only one free of wall interference effects with no PES flow. Surface pressures on the forward part of the other models were greater than interference-free results and were not influenced by PES flow. Interference-free results were achieved on the aft part of the 3- and 6-percent blockage models with the proper amount of PES flow. The required PES flow was substantially reduced by opening the reentry flaps.

Burley, Richard R.↗

Flow characteristics in boundary layer bleed slots with plenum

Numerical simulations were conducted to investigate the performance characteristics of bleed through normal slots and its effect on the turbulent boundary layer development under zero and strong adverse pressure gradient caused by incident oblique shock. The solution to the compressible Navier-Stokes and k-epsilon equations was obtained in a domain that includes the regions inside the bleed slot and plenum in addition to the external flow. The computational results demonstrate the interactions between the plenum and bleed flow and the effect of incident shock on the boundary layer development downstream. The computed results agree with the experimentally measured pitot and static pressure distribution inside the slot. The bleed mass flow without incident shock was underpredicted over the range of plenum pressures. The computations predicted the measured increase in bleed mass flow with incident shock.

Hamed, A.↗

A New Fast Fluid Dynamics Model for Data-Center Floor Plenums

A raised-floor plenum is often used to distribute cooling airflow in data centers. Traditional Computational Fluid Dynamics (CFD) can accurately model airflow distribution in plenums, but it is expensive (computationally and financially) and is, therefore, often not accessible to the data center designer or operator. This paper presents an alternative CFD methodology based on Fast Fluid Dynamics (FFD), which is faster, more parallelizable, and simpler to program. The improvement in computational speed afforded by FFD is particularly important for multiple-iteration optimization, transient simulations, or applications for which near-real-time performance is required. Here, the potential speed improvements of FFD have been widely documented; however, it has been generally accepted that this benefit is accompanied by a modest loss of accuracy relative to traditional CFD. We show here that this is not necessarily true. Plenum airflow predictions by our FFD implementation, which utilizes a first-order upwind rather than Semi-Lagrangian advection scheme of previous research, are extremely close to those predicted by traditional CFD - provided the same turbulence model and computational grid are used consistently.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD Simulations of Lower Plenum Mixing

Review of model development and validation performed in the Advanced Reactor Technologies (ART) program for thermal mixing at the outlet of High Temperature Gas Reactors (HTGRs). Understanding the mixing that occurs in the lower plenum in an HTGR is necessary to facilitate design improvements and to perform reactor safety analysis. Numerical models are one possible approach to gain a better understanding of mixing in the lower plenum. Given the complexity of the geometry and the intense mixing present, it is important to perform validation of numerical models. Three models have been developed during FY2025: a porous media with Pronghorn, a Reynolds Averaged Navier Stokes (RANS) with STAR-CCM+, and a Large Eddy Simulation (LES) with NekRS. The reference facility is a scaled-down version of the lower plenum of the High Temperature Gas-Cooled Reactor - Pebble-bed Module (HTR-PM) demonstration reactor. Preliminary results of the porous media and the RANS shows general good agreement against experimental benchmark data. Future work will leverage high-fidelity results obtained through LES to guide model selection and improvements to the lower-fidelity models, with particular attention to the Pronghorn porous media.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Model investigation of inlet plenum flow straightening techniques for altitude test facility

An investigation was conducted to evaluate and improve the quality of the airflow to be supplied to the engine in altitude test chambers 3 and 4 of the Propulsion Systems Laboratory at the Lewis Research Center. One-twentieth-scale models of the inlet plenum chamber of the two test chambers were used in the investigation to minimize time and cost. It was possible to reduce the velocity spread in the inlet plenum from approximately 100 m/sec (330 ft/sec) to approximately 10 m/sec (30 ft/sec) through the combined use of flow diverters, multiple spaced screens, flow straighteners, and turning vanes.

Riddlebaugh, S. M.↗

A theory for predicting boundary impedance and resonance frequencies of slotted-wall wind tunnels, including plenum effects

Wave-induced resonance associated with the geometry of wind-tunnel test sections can occur. A theory that uses acoustic impedance concepts to predict resonance modes in a two dimensional, slotted wall wind tunnel with a plenum chamber is described. The equation derived is consistent with known results for limiting conditions. The computed resonance modes compare well with appropriate experimental data. When the theory is applied to perforated wall test sections, it predicts the experimentally observed closely spaced modes that occur when the wavelength is not long compared with he plenum depth.

Barger, R. L.↗

Use of scaled BWR lower plenum boron mixing tests to qualify the boron transport model used in TRACG

In 2001 GEH applied best estimate methods combined with a statistical methodology to determine upper bound limits for key licensing parameters for anticipated operation occurrence (AOO) transient and anticipated transients without scram (ATWS) overpressure analyses for operating Boiling Water Reactors (BWRs). The methodology was subsequently extended for ESBWR AOO, ATWS, loss of coolant, and stability analyses. GEH is extending the methodology to long-term ATWS analyses for the operating BWRs. A long-term ATWS scenario uses injection of borated water to achieve reactor shutdown. Predicting the mixing and transport of boron is important for calculating the impact on the key licensing parameters. For the many operating BWRs where the denser boron solution is injected into the lower plenum, stratification may occur, delaying boron transport to the core region. CFD modeling can be used to model the stratification and mixing of the boron solution, but such calculations are extremely computer intensive and not cost effective; therefore, a more-empirical approach supported by a theoretical scaling of the dominant phenomena and backed by test data and benchmark calculations is used. The paper presents the TRACG lower plenum boron transport model qualification effort. The scaling basis used to implement the TRACG boron transport model for BWR applications is discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Fluid Dynamic Analysis of the VHTR Lower Plenum Standard Problem

The United States Department of Energy is promoting the resurgence of nuclear power in the U. S. for both electrical power generation and production of process heat required for industrial processes such as the manufacture of hydrogen for use as a fuel in automobiles. The DOE project is called the next generation nuclear plant (NGNP) and is based on a Generation IV reactor concept called the very high temperature reactor (VHTR), which will use helium as the coolant at temperatures ranging from 450 ºC to perhaps 1000 ºC. While computational fluid dynamics (CFD) has not been used for past safety analysis for nuclear reactors in the U. S., it is being considered for safety analysis for existing and future reactors. It is fully recognized that CFD simulation codes will have to be validated for flow physics reasonably close to actual fluid dynamic conditions expected in normal and accident operational situations. To this end, experimental data have been obtained in a scaled model of a narrow slice of the lower plenum of a prismatic VHTR. The present report presents results of CFD examinations of these data to explore potential issues with the geometry, the initial conditions, the flow dynamics and the data needed to fully specify the inlet and boundary conditions; results for several turbulence models are examined. Issues are addressed and recommendations about the data are made.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗