Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CFD Analysis of Upper Plenum Flow for a Sodium-Cooled Small Modular Reactor

Upper plenum flow behavior is important for many operational and safety issues in sodium fast reactors. The Prototype Gen-IV Sodium Fast Reactor (PGSFR), a pool-type, 150 MWe output power design, was used as a reference case for a detailed characterization of upper plenum flow for normal operating conditions. Computational Fluid Dynamics (CFD) simulation was utilized with detailed geometric modeling of major structures. Core outlet conditions based on prior system-level calculations were mapped to approximate the outlet temperatures and flow rates for each core assembly. Core outlet flow was found to largely bypass the Upper Internal Structures (UIS). Flow curves over the shield and circulates within the pool before exiting the plenum. Cross-flows and temperatures were evaluated near the core outlet, leading to a proposed height for the core outlet thermocouples to ensure accurate assembly-specific temperature readings. A passive scalar was used to evaluate fluid residence time from core outlet to IHX inlet, which can be used to assess the applicability of various methods for monitoring fuel failure. Additionally, the gas entrainment likelihood was assessed based on the CFD simulation results. Based on the evaluation of velocity gradients and turbulent kinetic energies and the available gas entrainment criteria in the literature, it was concluded that significant gas entrainment is unlikely for the current PGSFR design.

computational fluid dynamics↗

Experimental and CFD Studies of Coolant Flow Mixing within Scaled Models of the Upper and Lower Plenums of NGNP Gas-Cooled Reactors

A 1/16th scaled VHTR experimental model was constructed and the preliminary test was performed in this study. To produce benchmark data for CFD validation in the future, the facility was first run at partial operation with five pipes being heated. PIV was performed to extract the vector velocity field for three adjacent naturally convective jets at statistically steady state. A small recirculation zone was found between the pipes, and the jets entered the merging zone at 3 cm from the pipe outlet but diverged as the flow approached the top of the test geometry. Turbulence analysis shows the turbulence intensity peaked at 41-45% as the jets mixed. A sensitivity analysis confirmed that 1000 frames were sufficient to measure statistically steady state. The results were then validated by extracting the flow rate from the PIV jet velocity profile, and comparing it with an analytic flow rate and ultrasonic flowmeter; all flow rates lie within the uncertainty of the other two methods for Tests 1 and 2. This test facility can be used for further analysis of naturally convective mixing, and eventually produce benchmark data for CFD validation for the VHTR during a PCC or DCC accident scenario. Next, a PTV study of 3000 images (1500 image pairs) were used to quantify the velocity field in the upper plenum. A sensitivity analysis confirmed that 1500 frames were sufficient to precisely estimate the flow. Subsequently, three (3, 9, and 15 cm) Y-lines from the pipe output were extracted to consider the output differences between 50 to 1500 frames. The average velocity field and standard deviation error that accrued in the three different tests were calculated to assess repeatability. The error was varied, from 1 to 14%, depending on Y-elevation. The error decreased as the flow moved farther from the output pipe. In addition, turbulent intensity was calculated and found to be high near the output. Reynolds stresses and turbulent intensity were used to validate the data by comparing it with benchmark data. The experimental data gave the same pattern as the benchmark data. A turbulent single buoyant jet study was performed for the case of LOFC in the upper plenum of scaled VHTR. Time-averaged profiles show that 3,000 frames of images were sufficient for the study up to second-order statistics. Self-similarity is an important feature of jets since the behavior of jets is independent of Reynolds number and a sole function of geometry. Self-similarity profiles were well observed in the axial velocity and velocity magnitude profile regardless of z/D where the radial velocity did not show any similarity pattern. The normal components of Reynolds stresses have self-similarity within the expected range. The study shows that large vortices were observed close to the dome wall, indicating that the geometry of the VHTR has a significant impact on its safety and performance. Near the dome surface, large vortices were shown to inhibit the flows, resulting in reduced axial jet velocity. The vortices that develop subsequently reduce the Reynolds stresses that develop and the impact on the integrity of the VHTR upper plenum surface. Multiple jets study, including two, three and five jets, were investigated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New Fast Fluid Dynamics Model for Data-Center Floor Plenums

A raised-floor plenum is often used to distribute cooling airflow in data centers. Traditional Computational Fluid Dynamics (CFD) can accurately model airflow distribution in plenums, but it is expensive (computationally and financially) and is, therefore, often not accessible to the data center designer or operator. This paper presents an alternative CFD methodology based on Fast Fluid Dynamics (FFD), which is faster, more parallelizable, and simpler to program. The improvement in computational speed afforded by FFD is particularly important for multiple-iteration optimization, transient simulations, or applications for which near-real-time performance is required. Here, the potential speed improvements of FFD have been widely documented; however, it has been generally accepted that this benefit is accompanied by a modest loss of accuracy relative to traditional CFD. We show here that this is not necessarily true. Plenum airflow predictions by our FFD implementation, which utilizes a first-order upwind rather than Semi-Lagrangian advection scheme of previous research, are extremely close to those predicted by traditional CFD - provided the same turbulence model and computational grid are used consistently.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD Simulations of Lower Plenum Mixing

Review of model development and validation performed in the Advanced Reactor Technologies (ART) program for thermal mixing at the outlet of High Temperature Gas Reactors (HTGRs). Understanding the mixing that occurs in the lower plenum in an HTGR is necessary to facilitate design improvements and to perform reactor safety analysis. Numerical models are one possible approach to gain a better understanding of mixing in the lower plenum. Given the complexity of the geometry and the intense mixing present, it is important to perform validation of numerical models. Three models have been developed during FY2025: a porous media with Pronghorn, a Reynolds Averaged Navier Stokes (RANS) with STAR-CCM+, and a Large Eddy Simulation (LES) with NekRS. The reference facility is a scaled-down version of the lower plenum of the High Temperature Gas-Cooled Reactor - Pebble-bed Module (HTR-PM) demonstration reactor. Preliminary results of the porous media and the RANS shows general good agreement against experimental benchmark data. Future work will leverage high-fidelity results obtained through LES to guide model selection and improvements to the lower-fidelity models, with particular attention to the Pronghorn porous media.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of scaled BWR lower plenum boron mixing tests to qualify the boron transport model used in TRACG

In 2001 GEH applied best estimate methods combined with a statistical methodology to determine upper bound limits for key licensing parameters for anticipated operation occurrence (AOO) transient and anticipated transients without scram (ATWS) overpressure analyses for operating Boiling Water Reactors (BWRs). The methodology was subsequently extended for ESBWR AOO, ATWS, loss of coolant, and stability analyses. GEH is extending the methodology to long-term ATWS analyses for the operating BWRs. A long-term ATWS scenario uses injection of borated water to achieve reactor shutdown. Predicting the mixing and transport of boron is important for calculating the impact on the key licensing parameters. For the many operating BWRs where the denser boron solution is injected into the lower plenum, stratification may occur, delaying boron transport to the core region. CFD modeling can be used to model the stratification and mixing of the boron solution, but such calculations are extremely computer intensive and not cost effective; therefore, a more-empirical approach supported by a theoretical scaling of the dominant phenomena and backed by test data and benchmark calculations is used. The paper presents the TRACG lower plenum boron transport model qualification effort. The scaling basis used to implement the TRACG boron transport model for BWR applications is discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Fluid Dynamic Analysis of the VHTR Lower Plenum Standard Problem

The United States Department of Energy is promoting the resurgence of nuclear power in the U. S. for both electrical power generation and production of process heat required for industrial processes such as the manufacture of hydrogen for use as a fuel in automobiles. The DOE project is called the next generation nuclear plant (NGNP) and is based on a Generation IV reactor concept called the very high temperature reactor (VHTR), which will use helium as the coolant at temperatures ranging from 450 ºC to perhaps 1000 ºC. While computational fluid dynamics (CFD) has not been used for past safety analysis for nuclear reactors in the U. S., it is being considered for safety analysis for existing and future reactors. It is fully recognized that CFD simulation codes will have to be validated for flow physics reasonably close to actual fluid dynamic conditions expected in normal and accident operational situations. To this end, experimental data have been obtained in a scaled model of a narrow slice of the lower plenum of a prismatic VHTR. The present report presents results of CFD examinations of these data to explore potential issues with the geometry, the initial conditions, the flow dynamics and the data needed to fully specify the inlet and boundary conditions; results for several turbulence models are examined. Issues are addressed and recommendations about the data are made.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technology Solutions Case Study: Sealed Air-Return Plenum Retrofit

In this project, Pacific Northwest National Laboratory researchers greatly improved indoor air quality and HVAC performance by replacing an old, leaky air handler with a new air handler with an air-sealed return plenum with filter; they also sealed the ducts, and added a fresh air intake.

air handler↗

CFD Analysis of RLUOB Zone 1 HEPA Filter Plenum and Testing Manifolds

The purpose of this computational fluid dynamics (CFD) analysis is to ensure that Camfil Farr’s upstream and downstream injection and sampling manifolds can meet or exceed the requirements outlined in the ASME AG-1 1997 a(2000) Code on Nuclear Air and Gas Treatment for the testing of HEPA and adsorbent filters. This paper will present a numerical simulation of airflow in the Radiological Laboratory Utility Office Building (RLUOB) zone 1 HEPA filter plenum and testing manifolds using the commercial CFD software ANSYS FLUENT 2020R1. The CFD analysis focuses on the investigation of the air flow distribution and air-aerosol mixing uniformity. The evaluation was done for all steps of the modeling process: grid generation, physics setup, simulation, and post-processing. The mass flow rate in each section of the zone 1 injection and sampling manifolds is also reported.

42 ENGINEERING↗

Coupled computational fluid dynamics and heat transfer analysis of the VHTR lower plenum.

The very high temperature reactor (VHTR) concept is being developed by the US Department of Energy (DOE) and other groups around the world for the future generation of electricity at high thermal efficiency (> 48%) and co-generation of hydrogen and process heat. This Generation-IV reactor would operate at elevated exit temperatures of 1,000-1,273 K, and the fueled core would be cooled by forced convection helium gas. For the prismatic-core VHTR, which is the focus of this analysis, the velocity of the hot helium flow exiting the core into the lower plenum (LP) could be 35-70 m/s. The impingement of the resulting gas jets onto the adiabatic plate at the bottom of the LP could develop hot spots and thermal stratification and inadequate mixing of the gas exiting the vessel to the turbo-machinery for energy conversion. The complex flow field in the LP is further complicated by the presence of large cylindrical graphite posts that support the massive core and inner and outer graphite reflectors. Because there are approximately 276 channels in the VHTR core from which helium exits into the LP and a total of 155 support posts, the flow field in the LP includes cross flow, multiple jet flow interaction, flow stagnation zones, vortex interaction, vortex shedding, entrainment, large variation in Reynolds number (Re), recirculation, and mixing enhancement and suppression regions. For such a complex flow field, experimental results at operating conditions are not currently available. Instead, the objective of this paper is to numerically simulate the flow field in the LP of a prismatic core VHTR using the Sandia National Laboratories Fuego, which is a 3D, massively parallel generalized computational fluid dynamics (CFD) code with numerous turbulence and buoyancy models and simulation capabilities for complex gas flow fields, with and without thermal effects. The code predictions for simpler flow fields of single and swirling gas jets, with and without a cross flow, are validated using reported experimental data and theory. The key processes in the LP are identified using phenomena identification and ranking table (PIRT). It may be argued that a CFD code that accurately simulates simplified, single-effect flow fields with increasing complexity is likely to adequately model the complex flow field in the VHTR LP, subject to a future experimental validation. The PIRT process and spatial and temporal discretizations implemented in the present analysis using Fuego established confidence in the validation and verification (V and V) calculations and in the conclusions reached based on the simulation results. The performed calculations included the helicoid vortex swirl model, the dynamic Smagorinsky large eddy simulation (LES) turbulence model, participating media radiation (PMR), and 1D conjugate heat transfer (CHT). The full-scale, half-symmetry LP mesh used in the LP simulation included unstructured hexahedral elements and accounted for the graphite posts, the helium jets, the exterior walls, and the bottom plate with an adiabatic outer surface. Results indicated significant enhancements in heat transfer, flow mixing, and entrainment in the VHTR LP when using swirling inserts at the exit of the helium flow channels into the LP. The impact of using various swirl angles on the flow mixing and heat transfer in the LP is qualified, including the formation of the central recirculation zone (CRZ), and the effect of LP height. Results also showed that in addition to the enhanced mixing, the swirling inserts result in negligible additional pressure losses and are likely to eliminate the formation of hot spots.

08 HYDROGEN↗

OSU High Temperature Test Facility Test Acceptance Report, PG-28 Low Power (<350kW) Lower Plenum Mixing Test

Test Acceptance Report for Test PG-28 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OSU High Temperature Test Facility Test Acceptance Report, PG-30 Low Power (<350kW) Lower Plenum Mixing, Constant Temperature Test

Test Acceptance Report for Test PG-30 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An intelligent scanning algorithm for lost fuel rod recovery in the MYRRHA lower plenum

This paper presents a system for visualizing the interior structure of a vessel filled with a liquid metal. Due to the opaque and conductive nature of the medium, regular visualization systems based on cameras, electromagnetic or laser based techniques can't be used. The operation, strengths and weaknesses of an existing set-up are investigated by creating a scenario to find and extract a rectangular object inside the vessel in the shortest possible time. The main focus of this paper is not on designing a new system but to investigate the bottlenecks that are faced and need to be kept in mind in future designs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗